Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emission spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ablation dynamics and plasma chemistry of aluminum induced by temporally modulated ytterbium fiber laser

Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Power ECR Ion Thruster Discharge Characterization

Electron cyclotron resonance (ECR) based ion thrusters with carbon based ion optics can potentially satisfy lifetime requirements for long duration missions (approximately 10 years) because grid erosion and cathode insert depletion issues are virtually eliminated. Though the ECR plasma discharge has been found to typically operate at slightly higher discharge losses than conventional DC ion thrusters (for high total thruster power applications), the discharge power fraction is small (less than 1 percent at 25 kW). In this regard, the benefits of increased life, low discharge plasma potentials, and reduced complexity are welcome tradeoffs for the associated discharge efficiency decrease. Presented here are results from discharge characterization of a large area ECR plasma source for gridded ion thruster applications. These measurements included load matching efficacy, bulk plasma properties via Langmuir probe, and plasma uniformity as measured using current probes distributed at the exit plane. A high degree of plasma uniformity was observed (flatness greater than 0.9). Additionally, charge state composition was qualitatively evaluated using emission spectroscopy. Plasma induced emission was dominated by xenon ion lines. No doubly charged xenon ions were detected.

Foster, John E.↗

TOI 762Ab and TIC 46432937b: Two Giant Planets Transiting M-dwarf Stars

We present the discovery of TOI 762 A b and TIC 46432937 b, two giant planets transiting M-dwarf stars. Transits of both systems were first detected from observations by the NASA TESS mission, and the transiting objects are confirmed as planets through high-precision radial velocity observations carried out with Very Large Telescope/ESPRESSO. TOI 762 A b is a warm sub-Saturn with a mass of 0.251±0.042MJ, a radius of 0.744±0.017RJ, and an orbital period of 3.4717 days. It transits a mid-M-dwarf star with a mass of 0.442±0.025M☉and a radius of0.4250±0.0091R☉. The star TOI 762 A has a resolved binary star companion, TOI 762 B, that is separated fromTOI 762 A by 32(∼319 au)and has an estimated mass of 0.227±0.010M☉. The planet TIC 46432937 b is a warm super-Jupiter with a mass of 3.20±0.11MJ and radius of 1.188±0.030RJ. The planet’s orbital period isP=1.4404 days, and it undergoes grazing transits of its early M-dwarf host star, which has a mass of0.563±0.029M☉and a radius of 0.5299±0.0091R☉. TIC 46432937 b is one of the highest-mass planets found to date transiting an M-dwarf star. TIC 46432937 b is also a promising target for atmospheric observations, having the highest transmission spectroscopy metric or emission spectroscopy metric value of any known warm super-Jupiter(mass greater than 3.0MJ, equilibrium temperature below 1000 K).

Exoplanet systems↗

Resonant inelastic X-ray scattering using a miniature dispersive Rowland refocusing spectrometer

X-ray absorption spectroscopy (XAS) beamlines worldwide are steadily increasing their emphasis on full photon-in/photon-out spectroscopies, such as resonant inelastic X-ray scattering (RIXS), resonant X-ray emission spectroscopy (RXES) and high energy resolution fluorescence detection XAS (HERFD-XAS). In such cases, each beamline must match the choice of emission spectrometer to the scientific mission of its users. Previous work has recently reported a miniature tender X-ray spectrometer using a dispersive Rowland refocusing (DRR) geometry that functions with high energy resolution even with a large X-ray spot size on the sample. This instrument has been used in the laboratory in multiple studies of non-resonant X-ray emission spectroscopy using a conventional X-ray tube, though only for preliminary measurements at a low-intensity microfocus synchrotron beamline. This paper reports an extensive study of the performance of a miniature DRR spectrometer at an unfocused wiggler beamline, where the incident monochromatic flux allows for resonant studies which are impossible in the laboratory. Here, the results support the broader use of the present design and also suggest that the DRR method with an unfocused beam could have important applications for materials with low radiation damage thresholds and that would not survive analysis on focused beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting Low- and High-redshift Weak Emission-line Quasars via Hubble Space Telescope Spectroscopy of Lyα Emission

We present ultraviolet spectroscopy covering the Lyα + N v complex of six candidate low-redshift (0.9 < z < 1.5) weak emission-line quasars (WLQs) based on observations with the Hubble Space Telescope. The original systematic searches for these puzzling Type 1 quasars with intrinsically weak broad emission lines revealed an N ≈ 100 WLQ population from optical spectroscopy of high-redshift (z > 3) quasars, defined by a Lyα + N v rest-frame equivalent width (EW) threshold <15.4 Å. Identification of lower-redshift (z < 3) WLQ candidates, however, has relied primarily on optical spectroscopy of weak broad emission lines at longer rest-frame wavelengths. With these new observations expanding existing optical coverage into the ultraviolet, we explore unifying the low- and high-z WLQ populations via EW[Lyα+N v]. Two objects in the sample unify with high-z WLQs, three others appear consistent with the intermediate portion of the population connecting WLQs and normal quasars, and the final object is consistent with typical quasars. The expanded wavelength coverage improves the number of available line diagnostics for our individual targets, allowing a better understanding of the shapes of their ionizing continua. The ratio of EW[Lyα+N v] to EW[Mg ii] in our sample is generally small but varied, favoring a soft ionizing continuum scenario for WLQs, and we find a lack of correlation between EW[Lyα+N v] and the X-ray properties of our targets, consistent with a "slim-disk" shielding gas model. We also find indications that weak absorption may be a more significant contaminant in low-z WLQ populations than previously thought.

79 ASTRONOMY AND ASTROPHYSICS↗

Rocket Engine Plume Diagnostics at Stennis Space Center

The Stennis Space Center has been at the forefront of development and application of exhaust plume spectroscopy to rocket engine health monitoring since 1989. Various spectroscopic techniques, such as emission, absorption, FTIR, LIF, and CARS, have been considered for application at the engine test stands. By far the most successful technology h a been exhaust plume emission spectroscopy. In particular, its application to the Space Shuttle Main Engine (SSME) ground test health monitoring has been invaluable in various engine testing and development activities at SSC since 1989. On several occasions, plume diagnostic methods have successfully detected a problem with one or more components of an engine long before any other sensor indicated a problem. More often, they provide corroboration for a failure mode, if any occurred during an engine test. This paper gives a brief overview of our instrumentation and computational systems for rocket engine plume diagnostics at SSC. Some examples of successful application of exhaust plume spectroscopy (emission as well as absorption) to the SSME testing are presented. Our on-going plume diagnostics technology development projects and future requirements are discussed.

Tejwani, Gopal D.↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Atom-Specific Probing of Electron Dynamics in an Atomic Adsorbate by Time-Resolved X-Ray Spectroscopy

The electronic excitation occurring on adsorbates at ultrafast timescales from optical lasers that initiate surface chemical reactions is still an open question. Here, in this work, we report the ultrafast temporal evolution of x-ray absorption spectroscopy (XAS) and x-ray emission spectroscopy (XES) of a simple well-known adsorbate prototype system, namely carbon (C) atoms adsorbed on a nickel [Ni(100)] surface, following intense laser optical pumping at 400 nm. We observe ultrafast (~100 fs) changes in both XAS and XES showing clear signatures of the formation of a hot electron-hole pair distribution on the adsorbate. This is followed by slower changes on a few picoseconds timescale, shown to be consistent with thermalization of the complete C/Ni system. Density functional theory spectrum simulations support this interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Changes in polarization dictate necessary approximations for modeling electronic deexcitation intensity: Application to x-ray emission

Accurate simulation of electronic excitations and deexcitations are critical for complementing complex spectroscopic experiments and can provide validation to theoretical approaches. Here, using a generalized framework, we contrast the accuracy and validity of orbital-constrained and linear-response approaches that build upon Kohn-Sham density functional theory (DFT) to simulate emission spectra of electronic origin and propose an efficient approximation, named many-body x-ray emission spectroscopy or MBXES, for simulating such processes. We show analytically as well as with computed examples that for electronic (de)excitation leading to an appreciable change in polarization (i.e., density rearrangement), the adiabatic approximation in a response-based formalism will be inadequate for the calculation of oscillator strength. Thus, such a change (e.g., in the net electrostatic dipole moment of a finite system) can be used as a metric for evaluating the applicability of the adiabatic response-based approach and can be particularly valuable in x-ray emission spectroscopy. On the other hand, MBXES, the flexible method introduced in this paper, can compute oscillator strengths accurately at a much lower computational expense on the basis of two DFT-based self-consistent field calculations. Using illustrative examples of emission spectra, the efficacy of the MBXES method is demonstrated by comparison with its parent theory, orbital-optimized DFT, and with experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗

The Liquid Jet Endstation for Hard X-ray Scattering and Spectroscopy at the Linac Coherent Light Source

The ability to study chemical dynamics on ultrafast timescales has greatly advanced with the introduction of X-ray free electron lasers (XFELs) providing short pulses of intense X-rays tailored to probe atomic structure and electronic configuration. Fully exploiting the full potential of XFELs requires specialized experimental endstations along with the development of techniques and methods to successfully carry out experiments. The liquid jet endstation (LJE) at the Linac Coherent Light Source (LCLS) has been developed to study photochemistry and biochemistry in solution systems using a combination of X-ray solution scattering (XSS), X-ray absorption spectroscopy (XAS), and X-ray emission spectroscopy (XES). The pump–probe setup utilizes an optical laser to excite the sample, which is subsequently probed by a hard X-ray pulse to resolve structural and electronic dynamics at their intrinsic femtosecond timescales. The LJE ensures reliable sample delivery to the X-ray interaction point via various liquid jets, enabling rapid replenishment of thin samples with millimolar concentrations and low sample volumes at the 120 Hz repetition rate of the LCLS beam. This paper provides a detailed description of the LJE design and of the techniques it enables, with an emphasis on the diagnostics required for real-time monitoring of the liquid jet and on the spatiotemporal overlap methods used to optimize the signal. Additionally, various scientific examples are discussed, highlighting the versatility of the LJE.

EXAFS↗

Far-infrared emission line spectroscopy of planetary nebulae from the KAO

The main focus of the overall project was to study the properties of planetary nebulae using far-infrared emission lines. The observations were conducted with the 'cooled grating spectrometer' or CGS, a moderate-resolution echelle spectrometer designed and built at the Ames Research Center. During the first few years of the program, the emphasis was on emission lines of doubly-ionized oxygen and nitrogen ((O III) 52 and 88 microns, (N III) 57 microns), which arise in the ionized regions of the nebulae. Starting around 1989, our emphasis shifted to observing fine-structure lines of neutral oxygen and singly-ionized carbon ((O I) 63 and 145 microns, (C II) 157 microns), which arise from predominantly neutral material outside the ionized regions. This program was typically assigned one or two observing flights per year. Because these studies required obtaining a substantial sample of objects in order to reach meaningful conclusions, publication of comprehensive papers summarizing all of the results is still pending. However, numerous interim reports based on the airborne results as well as on closely-related supporting observations have been published during the grant period. The bibliographic information for these reports is given in the publications section. An overall summary of the planetary nebula results was presented at the Airborne Astronomy Symposium (20th Anniversary of the KAO) on 8 July 1994; reprints will be provided when available. In parallel with the planetary nebula study, we also observed the (O III) and (N III) lines in several H II regions, and attempted (unsuccessfully) to detect these lines in several old nova remnants and the supernova remnant Cassiopeia A.

Dinerstein, Harriet L.↗

New reflections on hard X-ray photon-in/photon-out spectroscopy

Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.

47 OTHER INSTRUMENTATION↗

Pulse Detonation Rocket MHD Power Experiment

A pulse detonation research engine (MSFC (Marshall Space Flight Center) Model PDRE (Pulse Detonation Rocket Engine) G-2) has been developed for the purpose of examining integrated propulsion and magnetohydrodynamic power generation applications. The engine is based on a rectangular cross-section tube coupled to a converging-diverging nozzle, which is in turn attached to a segmented Faraday channel. As part of the shakedown testing activity, the pressure wave was interrogated along the length of the engine while running on hydrogen/oxygen propellants. Rapid transition to detonation wave propagation was insured through the use of a short Schelkin spiral near the head of the engine. The measured detonation wave velocities were in excess of 2500 m/s in agreement with the theoretical C-J velocity. The engine was first tested in a straight tube configuration without a nozzle, and the time resolved thrust was measured simultaneously with the head-end pressure. Similar measurements were made with the converging-diverging nozzle attached. The time correlation of the thrust and head-end pressure data was found to be excellent. The major purpose of the converging-diverging nozzle was to configure the engine for driving an MHD generator for the direct production of electrical power. Additional tests were therefore necessary in which seed (cesium-hydroxide dissolved in methanol) was directly injected into the engine as a spray. The exhaust plume was then interrogated with a microwave interferometer in an attempt to characterize the plasma conditions, and emission spectroscopy measurements were also acquired. Data reduction efforts indicate that the plasma exhaust is very highly ionized, although there is some uncertainty at this time as to the relative abundance of negative OH ions. The emission spectroscopy data provided some indication of the species in the exhaust as well as a measurement of temperature. A 24-electrode-pair segmented Faraday channel and 0.6 Tesla permanent magnet assembly were then installed on Marshall Space Flight Center's (MSFC's) rectangular channel pulse detonation research engine. Magnetohydrodynamic (MHD) electrical power extraction experiments were carried out for a range of load impedances in which cesium hydroxide seed (dissolved in methanol) was sprayed into the gaseous oxygen/hydrogen propellants. Positive power extraction was obtained, but preliminary analysis of the data indicated that the plasma electrical conductivity is lower than anticipated and the near-electrode voltage drop is not negligible. It is believed that the electrical conductivity is reduced due to a large population of negative OH ions. This occurs because OH has a strong affinity for capturing free electrons. The effect of near-electrode voltage drop is associated with the high surface-to-volume ratio of the channel (1-inch by 1-inch cross-section) where surface effects play a dominant role. As usual for MHD devices, higher performance will require larger scale devices. Overall, the gathered data is extremely valuable from the standpoint of understanding plasma behavior and for developing empirical scaling laws.

Litchford, Ron J.↗

Tender X-Ray Photo-in/Photon-out Spectroscopy

We address technical aspects and applications of tender X-ray emission spectroscopy. Examples in catalysis, coordination chemistry and geochemistry are presented where HERFD-XANES and RIXS were used to study the electronic structure. Advantages and challenges of tender X-ray photon-in/photon-out spectroscopy are discussed and an outlook is given.

47 OTHER INSTRUMENTATION↗

Electron cyclotron resonance deposition and plasma diagnostics of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films deposited by electron cyclotron resonance (ECR) microwave plasma-enhanced chemical vapor deposition are discussed. It is shown that the ECR microwave plasma deposition technique can produce a-Si:H films with material qualities similar to and with a deposition rate one order of magnitude higher than for films deposited by radio-frequency glow discharge. The ECR-deposited a-C:H films are characterized by fluorescence, IR, and Raman spectroscopy. In situ optical emission spectroscopy plasma diagnostics indicates that ECR plasmas have a strong emission at 434 nm, which indicates a higher chemical reactivity than radio-frequency glow discharge plasmas. The radio frequency bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR-deposited a-C:H films.

Shing, Y. H.↗