Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “elevated temperature and pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

An experimental and kinetic modeling study of cyclopentane and dimethyl ether blends

Cyclopentane is a suitable naphthene, or cycloalkane, in a palette for multi-component gasoline surrogate fuels due to its presence in market fuels and its relevance to alkyl substituted cyclopentanes also present. However, the previous oxidation studies of cyclopentane have primarily focused on neat mixtures. Blending cyclopentane with dimethyl ether in this work therefore serves to inform our understanding of, and improve predictive models for, multi-component mixtures. Here, the auto-ignition of cyclopentane/dimethyl ether blends was studied in a high-pressure shock tube and in a rapid compression machine. A wide range of temperatures (650 – 1350 K) and elevated pressures of 20 and 40 bar were studied at equivalence ratios of 0.5, 1.0 and 2.0 in air for two blending ratios (30/70 and 70/30 mole% cyclopentane/di-methyl ether mixtures). A detailed kinetic model for cyclopentane was revised to capture the measured ignition delay times and apparent heat release rates in this study. Literature ignition delay time, jet-stirred reactor, and laminar burning velocity measurements of neat cyclopentane were used as additional validation. Improvements to the kinetic model were based on recent literature studies related to sub-models including cyclopentene and cyclopentadiene which allowed the removal of previous local rate-constant optimizations. Low temperature reactivity of cyclopentane was found to be controlled by the branching ratio between concerted elimination of HO͘ 2 and the strained formation of Q&#775OOH radicals in agreement with previous studies. In this study, the low branching ratio of Q&#775OOH formation increases the influence of a competing consumption pathway for cyclopentyl-peroxy (CPTO͘ 2 J) radicals. The sensitivity of the simulated ignition delay times to the formation of cyclopentyl hydroperoxide (CPTO 2 H), from CPTO͘ 2 J and HO͘ 2 , is discussed. The current model is used to analyze the influence of dimethyl ether on the reactivity of cyclopentane in the context of previous literature studies of dimethyl ether binary blends with ethanol and toluene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Temperature Alloys Session 1

Section III Division 5 overview Code materials VHTR materials 617 and 800H Qualification of additional materials Corrosion effects Operating plant experience Additive/advanced manufacturing Control rod sleeves Pressure Vessel Steels Allowed materials Elevated temperature limits and properties Supply chain Welding Radiation damage

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Annealing of ion tracks in apatite under pressure characterized in situ by small angle x-ray scattering

Fission track thermochronology is routinely used to investigate the thermal history of sedimentary basins, as well as tectonic uplift and denudation rates. While the effect of temperature on fission track annealing has been studied extensively to calibrate the application of the technique, the effect of pressure during annealing is generally considered to be negligible. However, a previous study suggested elevated pressure results in a significantly different annealing behaviour that was previously unknown. Here, we present a method to study track annealing in situ under high pressure by using synchrotron- based small angle x-ray scattering (SAXS). To simulate fission tracks in a controlled environment, ion tracks were created in apatite from Durango, Mexico using 2 GeV Au or Bi ions provided by an ion accelerator facility. Samples were annealed at 250°C at approximately 1 GPa pressure using diamond anvil cells (DAcs) with heating capabilities. Additional in situ annealing experiments at ambient pressure and temperatures between 320 and 390°C were performed for comparison. At elevated pressure a significantly accelerated annealing rate of the tracks was observed compared with annealing at ambient pressure. However, when extrapolated to geologically relevant temperatures and pressures, the effects become very small. The measurement methodology presented provides a new avenue to study materials behaviour in extreme environments.

58 GEOSCIENCES↗

Volatility and Wear Characteristics of a Variety of Liquid Lubricants for Space Applications

The vapor pressures and wear characteristics are critical properties for liquid lubricants to assure long-term reliability and performance in space applications. Vapor pressures, obtained using a Knudsen cell technique, and wear properties, obtained using a vacuum four-ball apparatus, were measured for a series of unformulated liquid lubricants. These included two multiply alkylated cyclopentanes (MACs) (X-1000 and X2000), two linear perfluoropolyalkylethers (PFPAEs) (Z-25 and 815Z), and four silahydrocarbons (a tri, a tetra, and two pentas). Vapor pressures were measured at three elevated temperatures (423, 448, and 498 K) and extrapolated to room temperature 298 K. The lowest 298 K vapor pressure of 5.7 x 10(exp -14) Pa was obtained with the PFPAE fluid (815Z) and the highest value with the low molecular weight MAC (X-1000) at 3.6 x 10(exp -7) Pa. In addition, vacuum wear rates were determined for some of the lubricants. The lowest wear rates (approximately 3 x 10(exp -11) cubic mm/mm) were observed for three of the silahydrocarbons while the highest wear rates (approximately 2 x 10(exp -9) cubic mm/mm) were observed with the two PFPAE fluids (Z-25 and 815Z). The MAC (X-2000) yielded a wear rate of about 10(exp -10) cubic mm/mm. The results indicated that the silahydrocarbon class of liquid lubricants offers the better potential for space applications.

Nguyen, QuynhGiao N.↗

Volatility and Wear Characteristics of a Variety of Liquid Lubricants for Space Applications

The vapor pressures and near characteristics are critical properties for liquid lubricants to assure long-term reliability and performance in space applications. Vapor pressures, obtained using a Knudsen cell technique, and near properties, obtained using a vacuum four-ball apparatus, were measured for a series of unformulated liquid lubricants. These include: two multiple alkylated cyclopentanes (MACs) (X-1000 and X-2000), two linear perfluoropolyalkylethers (PFPAEs) (Z-25 and 815Z), and four silahydrocarbons (a tri-, a tetra-, and two pentas). Vapor pressures were measured at three elevated temperatures (423, 448, and 498 K) and extrapolated to room temperature 298 K. The lowest 298 K vapor pressure of 5.7 x 10(exp -14) Pa, was obtained with the PFPAE fluid (815Z) and the highest value with the low molecular weight MAC (X-1000) at 3.6 x 10(exp -7) Pa. In addition, vacuum near rates were determined for some of the lubricants. The lowest wear rates (approximately 3 x 10(exp -11) cubic mm/mm) were observed for three of the silahydrocarbons while the highest wear rate (approximately 2 x 10(exp-9) cubic mm/mm) were observed with the two PFPAE fluids (Z-25 and 815Z). The MAC (X-2000) yielded a wear rate of about 10(exp -10) cubic mm/mm. The results indicated that the silahydrocarbon class of liquid lubricants offers the better potential for space applications.

Nguyen, Quynhgiao N.↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the stability of reoriented hydrides and their reprecipitation using in-situ heating experiments

The behavior of radial hydrides in Zr-2.5Nb pressure tube samples at elevated temperature has been studied. The aim of this work is to investigate the stability of stress-reoriented hydrides under heating without an external applied load. Using in-situ heating at beamline, 1-ID at Argonne National Laboratory, USA, it was shown that two populations of hydrides existed in the sample, naturally oriented and reoriented hydrides. At a relatively low temperature of 180 °C it was observed that the reoriented hydrides completely dissolved, leaving only the naturally oriented hydrides in the sample, when heated without an applied load. On subsequent cooling of the sample, only naturally oriented hydrides were observed. These observations were confirmed using in-situ scanning electron microscopy heating experiments and post-mortem transmission electron microscopy studies. The results presented here offer a potential route for ductility recovery of pressure tube materials where radial hydrides have been shown to significantly reduce fracture toughness of components.

36 MATERIALS SCIENCE↗

Nitrile/Buna N Material Failure Assessment for an O-Ring used on the Gaseous Hydrogen Flow Control Valve (FCV) of the Space Shuttle Main Engine

After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.

Wingard, Doug↗

Alkyl-Substituted Polycaprolactone Poly(urethane-urea)s as Mechanically Competitive and Chemically Recyclable Materials

We report the mechanical performance and chemical recycling advantages of implementing alkyl-substituted poly(ε-caprolactones) (PCLs) as soft segments in thermoplastic poly(urethane-urea) (TPUU) materials. Poly(4-methylcaprolactone) (P4MCL) and poly(4-propylcaprolactone) (P4PrCL) were prepared, reacted with isophorone diisocyanate, and chain-extended with water to form TPUUs. The resulting materials’ tensile properties were similar or superior to a commercially available polyester thermoplastic poly(urethane) and had superior elastic recovery properties compared to a PCL analogue due to the noncrystalline nature of P4MCL and P4PrCL. Additionally, monomers were recovered from the TPUU materials in high yields via ring-closing depolymerization using a reactive distillation approach at an elevated temperature and a reduced pressure (240–260 °C, 25–140 mTorr) with zinc chloride (ZnCl 2 ) as the catalyst. The thermodynamics of polymerization were estimated using Van’t Hoff analyses for 4MCL and 4PrCL; these results indicated that the propyl group in 4PrCL results in a lower practical ceiling temperature (T c ) for P4PrCL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tribocatalytically-activated formation of protective friction and wear reducing carbon coatings from alkane environment

Minimizing the wear of the surfaces exposed to mechanical shear stresses is a critical challenge for maximizing the lifespan of rotary mechanical parts. In this study, we have discovered the anti-wear capability of a series of metal nitride-copper nanocomposite coatings tested in a liquid hydrocarbon environment. The results indicate substantial reduction of the wear in comparison to the uncoated steel substrate. Analysis of the wear tracks indicates the formation of carbon-based protective films directly at the sliding interface during the tribological tests. Raman spectroscopy mapping of the wear track suggests the amorphous carbon (a-C) nature of the formed tribofilm. Further analysis of the tribocatalytic activity of the best coating candidate, MoN-Cu, as a function of load (0.25–1 N) and temperature (25 °C and 50 °C) was performed in three alkane solutions, decane, dodecane, and hexadecane. Results indicated that elevated temperature and high contact pressure lead to different tribological characteristics of the coating tested in different environments. The elemental energy dispersive x-ray spectroscopy analysis and Raman analysis revealed formation of the amorphous carbon film that facilitates easy shearing at the contact interface thus enabling more stable friction behavior and lower wear of the tribocatalytic coating. These findings provide new insights into the tribocatalysis mechanism that enables the formation of zero-wear coatings.

36 MATERIALS SCIENCE↗

Determining the electrical conductivity of metals using the 2 MA Thor pulsed power driver

We present the development of a pulsed power experimental technique to infer the electrical conductivity of metals from ambient to high energy density conditions. The method is implemented on Thor, a moderate scale (1–2 MA) pulsed power driver. The electrical conductivity of copper at elevated temperature (>4000 K) and pressure (>10 GPa) is determined, and a new tabular material model is developed, guided by density functional theory, which preserves agreement with existing experimental data. Minor modifications (<10%) are found to be necessary to the previous Lee–More–Desjarlais model isotherms in the vicinity of the melt transition in order to account for observed discrepancies with the new experimental data. An analytical model for magnetic direct drive flyer acceleration and Joule heating induced vaporization based on the Tsiolkovsky “rocket equation” is presented to assess sensitivity of the method to minor changes in electrical conductivity.

47 OTHER INSTRUMENTATION↗

Nonequilibrium plasma in water vapor

A kinetic model of a non-equilibrium water vapor plasma created by a nanosecond pulsed discharge at elevated temperatures and at low pressure is presented. The model includes equations for electron, vibrational and gas temperatures combined with equations for neutral, charged, electronically and vibrationally excited species. Simulation results are compared with the available experimental data and show good agreement in dynamics of the plasma decay and electron drift velocities. It is shown that the plasma decay in pure water vapor is controlled by the dissociative recombination. Under the conditions simulated, the concentration of electronically excited species is low, but we observe a formation of vibrationally excited species. Finally, a significant decrease in the electrical conductivity of water plasma with time, which depends on the level of initial ionization, is shown.

42 ENGINEERING↗

X-Ray Radiography and Phase-Contrast Imaging of the Engine Combustion Network Spray B Sprays and Injection

X-ray measurements of diesel sprays from two of the Engine Combustion Network (ECN) Spray B injectors are described. Measurements in these three-hole nozzles complement both visible light measurements of these sprays and previous x-ray measurements of the axial single-hole ECN Spray A injectors. Both axial and lateral motions of the injector needle valve were measured with x-ray phase contrast imaging. Additionally, the liquid mass distribution in room temperature sprays at elevated ambient pressure was determined with x-ray radiography. Measurements of both needle valve motion and spray distribution were performed at both the standard Spray A/B conditions and with selected variations of injection pressure, ambient density, and injection timing. The needle valve motion for the Spray B injectors is quite similar to that of the Spray A injectors, though little lateral motion is seen in either Spray B injector. Compared to the sprays from the Spray A injectors, the sprays from Spray B penetrate more slowly in the near-nozzle region, demonstrate a broader, more uniform distribution in the transverse direction, and are significantly more variable with respect to time. These differences demonstrate the importance of studies with multi-hole nozzles to provide insight into applied diesel combustion.

42 ENGINEERING↗

Distribution of surface extremes in the United States

Extreme design environment data are presented for consideration in aerospace vehicle transportation, fabrication, or testing. Values were obtained by using data from weather stations and published meteorological articles. Maps depict snow fall, hail distribution, atmospheric pressure, atmospheric temperature, and surface elevations.

Daniels, G. E.↗

Superlubricity coating containing carbon nanotubes

A method for producing a structure containing an array of MWCNTs on a metal substrate, comprising: (i) subjecting a metal substrate to a surface oxidation process at a first elevated temperature in an oxygen-containing atmosphere and under a first reduced pressure; (ii) subjecting the metal substrate to a surface reduction process at a second elevated temperature in a reducing atmosphere and under a second reduced pressure of at least 0.01 atm and less than 1 atm to result in reduction of the surface of said metal substrate, wherein the reducing atmosphere contains hydrogen gas; (iii) subjecting the metal substrate to a third reduced pressure of no more than 0.1 atm; and (iv) contacting the metal substrate, while at the third reduced pressure and under an inert or reducing atmosphere, with an organic substance at a third elevated temperature for suitable time to produce the MWCNTs on the metal substrate.

Ihala Gamaralalage, Chanaka Kapila↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗