Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron streaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Artificial aurora conjugate to a rocket-borne electron accelerator

An accelerator intended to send electron beams upward along an L = 1.24 magnetic field line was flown from a rocket launched from Kauai, Hawaii, on October 15, 1972. Though the intent was to produce several hundred observable auroral streaks in the Southern Hemisphere, imaging instruments operated there aboard jet aircraft detected only a single aurora. Produced by a 0.155-A beam of energy 22.8 keV, the aurora was of expected brightness and had a diameter (210 + or - 50 m) somewhat larger than expected and an altitude (top 116 + or - 2 km; bottom 92 + or - 2 km) higher than expected.

Davis, T. N.↗

SU-E-T-325: Dosimetric Impact Due to FlexiShield in Electronic Brachytherapy (eBx) of Breast IORT: A Phantom Study

Purpose: To evaluate dosimetric change of eBx plan due to Flexishield. Methods: To simulate a clinically difficult case (skin spacing < 1 cm and touching chest wall), prostheses breast tissue phantom overlaid Xoft spherical balloon applicator. To minimize significant metal streak artifact, megavoltage CT (MVCT) scan was acquired using helical TomoTherapy HiART. Two sets of MVCT images were taken with/without FlexiShield for 15 cases: 4 for small (3–4 cm), 4 for medium (4–5 cm) and 7 for large (5–6 cm) balloon. Total 30 MVCT scans were obtained with 50 % contrast to improve image contrast of balloon relative to breast tissue phantom. Balloon deformation was measured in anterior-posterior (AP) and lateral (LAT) dimensions in the middle of balloon. Skin spacing was also evaluated. Treatment plan was made based on each MVCT scan and two balloon surface doses (AP and LAT directions) and skin dose were compared between plans with/without FlexiShield. Results: The balloon was deformed due to pressure from both FlexiShield (skin side) and FlexiShield mini (chest wall side). Mean ± standard deviation (maximum) value was 1.5 ± 1.0 mm (3.3 mm) for AP compression and 0.4 ± 0.3 mm (1.1 mm) for LAT expansion. Balloon surface dose was increased by 1.8 ± 1.2 Gy (4.9 Gy) at AP point and decreased by 0.4 ± 0.4 Gy (1.3 Gy) at LAT point. Skin spacing was constantly reduced by 1.1 ± 0.8 mm (3 mm). Skin surface dose was increased by 1.5 ± 0.8 Gy (3.3 Gy) and its relative increase was 17.9 ± 9.3% (39.6%). Conclusion: FlexiShield deforms the balloon and reduces skin spacing, thereby resulting in higher dose in AP direction, lower dose in LAT direction, and elevated skin dose compared to the plan without FlexiShield. In the clinic, this balloon deformation and corresponding dose variation should be considered.

60 APPLIED LIFE SCIENCES↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward streaked collective Thomson scattering measurements on an extreme ultraviolet plasma light source

Here we show through forward modeling calculations that streaked collective Thomson scattering measurements are feasible on laser-produced tin plasmas generated under conditions relevant for extreme ultraviolet lithography. Using a 532 nm probe laser beam, the feasibility of simultaneous measurements of electron plasma wave (EPW) and ion acoustic wave (IAW) spectra is investigated. Absolute photon counts for laser scattering off both waves are calculated. Probe laser electron heating and bremsstrahlung background radiation effects are accounted for. While a large spatiotemporal region can be successfully probed based on the IAW feature, only one measurement location can be accessed through the EPW as a result of the low signal to noise ratio. A portable/traveling tabletop system is proposed.

47 OTHER INSTRUMENTATION↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

A flexible apparatus for attosecond photoelectron spectroscopy of solids and surfaces

We describe an apparatus for attosecond photoelectron spectroscopy of solids and surfaces, which combines the generation of isolated attosecond extreme-ultraviolet (XUV) laser pulses by high harmonic generation in gases with time-resolved photoelectron detection and surface science techniques in an ultrahigh vacuum environment. This versatile setup provides isolated attosecond pulses with photon energies of up to 140 eV and few-cycle near infrared pulses for studying ultrafast electron dynamics in a large variety of surfaces and interfaces. The samples can be prepared and characterized on an atomic scale in a dedicated flexible surface science end station. The extensive possibilities offered by this apparatus are demonstrated by applying attosecond XUV pulses with a central photon energy of {approx}125 eV in an attosecond streaking experiment of a xenon multilayer grown on a Re(0001) substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast gated imaging of laser produced plasmas using the optical Kerr effect

Optical imaging is a versatile diagnostic for investigations of plasmas generated under intense laser irradiation. Electro-optic gating techniques operating on the >100 ps timescale are commonly used to reduce the amount of light detected from self-emission of hot plasma or improve the temporal resolution of the detector. The use of an optical Kerr gate enables a superior dynamic range and temporal resolution compared to electronically gated devices. The application of this method for enhanced imaging of laser produced plasmas with gate time approx100 fs is demonstrated, and the possibility to produce a sub-10 fs, high dynamic range 'all optical' streak camera is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts, although there is a loss of in-plane resolution near the metallic insert.

60 APPLIED LIFE SCIENCES↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV

The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., 'Considerations of rod-pinch diode operation in negative polarity for radiography,' in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., 'Theoretical modeling and experimental characterization of a rod-pinch diode,' Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., 'Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources,' IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., 'ASTERIX, a high intensity X-ray generator,' in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., 'Negative polarity rod pinch diode experiments on the ASTERIX generator,' in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to achieve the most comprehensive characterization of the diode, both optical and x-ray diagnostics were used, including high speed multi-image ICCD (intensified CCD) cameras, streak camera, dosimeters, spot size measurements, and pinhole cameras. A set of new results have been obtained through this study. The plasma emission from the anode and cathode surfaces and its expansion appear to be critical for the diode functioning. Also, for the first time, potential sources of diode instability were identified. Finally, an optimal and stable diode configuration was found with the following parameters: 52 rad at 1 m (in Al) and 2.2 mm spot size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research directed toward improved echelles for the ultraviolet

Low frequency gratings obtainable with present technology, can meet the grating-efficiency design goals for potential space telescope spectrographs. Gratings made with changes in the three specific parameters: the ruling tool profile, the coating material, and the lubricants used during the ruling process were compared. A series of coatings and test gratings were fabricated and were examined for surface smoothness with a Nomarski differential interference microscope and an electron microsocope. Photomicrographs were obtained to show the difference in smoothness of the various coatings and rulings. Efficiency measurements were made for those test rulings that showed good groove characteristics: smoothness, proper ruling depth, and absence of defects (e.g., streaks, feathered edges and rough sides). Higher grating efficiency should be correlated with the degree of smoothness of both the coating and the grating groove.

Source record↗

Deep Learning with Reflection High-Energy Electron Diffraction Images to Predict Cation Ratio in Sr 2 x Ti 2(1– x ) O 3 Thin Films

Machine learning (ML) with in-situ diagnostics offers a transformative approach to accelerate, understand, and control thin film synthesis by uncovering relationships between synthesis conditions and material properties. In this study, we demonstrate the application of deep learning to predict the stoichiometry of Sr 2x Ti 2(1–x) O 3 thin films using reflection high-energy electron diffraction images acquired during pulsed laser deposition. A gated convolutional neural network trained for regression of the Sr atomic fraction achieved accurate predictions with a small dataset of 31 samples. Explainable AI techniques revealed a previously unknown correlation between diffraction streak features and cation stoichiometry in Sr 2x Ti 2(1–x) O 3 thin films. Here, our results demonstrate how ML can be used to transform a ubiquitous in-situ diagnostic tool, that is usually limited to qualitative assessments, into a quantitative surrogate measurement of continuously valued thin film properties. Such methods are critically needed to enable real-time control, autonomous workflows, and accelerate traditional synthesis approaches.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evidence of anatase intergrowths formed during slow cooling of reduced ilmenite

Controlling the parameters during synthetic rutile production is essential to minimize production costs and ensure final product quality. Powder X-ray diffraction (PXRD) is typically used within the industry to guide process control. This work investigated the source of unusual features observed in the PXRD pattern of a slow-cooled reduced ilmenite (RI), which were not observed for a rapid-cooled RI. For the slow-cooled RI, the 002 peak of M 3 O 5 (anosovite) had disappeared and the intensity of the $ \overline{2}03\ $, 203, 204 and 402 peaks had decreased significantly compared to the pattern for the rapid-cooled RI. Using transmission electron microscopy, selected area electron diffraction (SAED) and pair distribution function (PDF) analysis, the authors attribute these features to M 3 O 5 –anatase intergrowth formation, which causes a loss in long-range order along the M 3 O 5 c axis. Strong diffuse streaking in the SAED patterns was also evident and supported the presence of disordered intergrowths from the oxidation of M 3 O 5 . PDF analysis showed a significant improvement in the fit to the data for the slow-cooled RI, primarily in the <17 Å region, when anatase was added to the PDF model. The results presented here highlight the importance of the reduction and cooling stages during the formation of these industrially relevant RI minerals, which may be used to direct the production process and final TiO 2 product quality.

D'Angelo, Anita M. (ORCID:0000000230685288)↗

Longitudinal Profile Diagnostic Scheme with Subfemtosecond Resolution for High-Brightness Electron Beams

High-resolution measurement of the longitudinal profile of a relativistic electron beam is of utmost importance for linac based free-electron lasers and other advanced accelerator facilities that employ ultrashort bunches. In this paper, we investigate a novel scheme to measure ultrashort bunches (subpicosecond) with exceptional temporal resolution (hundreds of attoseconds) and dynamic range. The scheme employs two orthogonally oriented deflecting sections. The first imparts a short-wavelength (fast temporal resolution) horizontal angular modulation on the beam, while the second imparts a long-wavelength (slow) angular kick in the vertical dimension. Both modulations are observable on a standard downstream screen in the form of a streaked sinusoidal beam structure. We demonstrate, using scaled variables in a quasi-1D approximation, an expression for the temporal resolution of the scheme and apply it to a proof-of-concept experiment at the UCLA Neptune high-brightness injector facility. The scheme is also investigated for application at the SLAC NLCTA facility, where we show that the subfemtosecond resolution is sufficient to resolve the temporal structure of the beam used in the echo-enabled free-electron laser. We employ beam simulations to verify the effect for typical Neptune and NLCTA parameter sets and demonstrate the feasibility of the concept.

43 PARTICLE ACCELERATORS↗

Measurements of Picosecond Energy Equilibration in Isochorically Heated Materials

In this Final Report we present the results of our DOE/FES-sponsored research on rapidly heated materials. The research focused on the details of picosecond energy equilibration and material response to isochoric heating by relativistic (or “hot”) electrons. The major goal was to improve the understanding of these processes by making time-resolved extreme ultraviolet (XUV) measurements of ultrafast energy deposition and blast-wave formation for testing impulsive-heating models in extreme thermodynamic conditions. Major achievements of the project include the design, fabrication, deployment, and use of two XUV spectrometers on the Multi-Terawatt (MTW) Laser System at the University of Rochester’s Laboratory for Laser Energetics. One of the spectrometers is coupled to an x-ray charge-coupled device (CCD) for time-integrated measurements; the other is coupled to an ultrafast x-ray streak camera for time-resolved measurements. Working together, these instruments provide absolutely calibrated data on the emitted XUV spectrum from an isochoric heated target. The new diagnostic system was used to measure and infer the time-resolved rear-surface temperature and density for different target materials and different target-interaction conditions. Experiments with laser-heated metal foils measured the ultrafast dynamics and energy deposition from hot electrons into plasma heating and blast-wave formation. The blast wave was observed emerging from the rear surface of the laser-irradiated target. The time between the prompt emission (electron-driven x-ray emission) and the blast-wave arrival was used to estimate the energy deposition into the wave. The data are consistent with a Sedov–Taylor blast wave, with energy transfer from the laser to the blast of up to 20 mJ. The data represent the first quantitative assessment of the blast-wave energy in a metal following heating by a short burst of high-intensity laser-generated hot electrons. The funding from this grant provided significant opportunities for training and professional development. The grant supported or partially supported a graduate student, a postdoctoral research associate, and a senior staff scientist. This support included bringing together a dedicated group of individuals with a niche set of experimental and theoretical skills for studying advanced material properties experiments and ultrafast radiation conditions. The team dynamic fostered training and knowledge transfer across the whole spectrum of research activities through shared experiences in advanced laboratory techniques, data analysis, modeling, and the development of new ideas, techniques, presentations, and publications. The results of this work, which significantly improve the understanding of rapid energy deposition in solid matter, have been widely disseminated to communities of interest through invited talks, contributed talks, and peer-reviewed journals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗