Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

n-Butanol production by Rhodopseudomonas palustris TIE-1

Anthropogenic carbon dioxide (CO 2 ) release in the atmosphere from fossil fuel combustion has inspired scientists to study CO 2 to biofuel conversion. Oxygenic phototrophs such as cyanobacteria have been used to produce biofuels using CO 2 . However, oxygen generation during oxygenic photosynthesis adversely affects biofuel production efficiency. To produce n-butanol (biofuel) from CO 2 , here we introduce an n-butanol biosynthesis pathway into an anoxygenic (non-oxygen evolving) photoautotroph, Rhodopseudomonas palustris TIE-1 (TIE-1). Using different carbon, nitrogen, and electron sources, we achieve n-butanol production in wild-type TIE-1 and mutants lacking electron-consuming (nitrogen-fixing) or acetyl-CoA-consuming (polyhydroxybutyrate and glycogen synthesis) pathways. The mutant lacking the nitrogen-fixing pathway produce the highest n-butanol. Coupled with novel hybrid bioelectrochemical platforms, this mutant produces n-butanol using CO 2 , solar panel-generated electricity, and light with high electrical energy conversion efficiency. Overall, this approach showcases TIE-1 as an attractive microbial chassis for carbon-neutral n-butanol bioproduction using sustainable, renewable, and abundant resources.

60 APPLIED LIFE SCIENCES↗

Photodissociation of aqueous I3− observed with liquid-phase ultrafast mega-electron-volt electron diffraction

Developing femtosecond resolution methods for directly observing structural dynamics is critical to understanding complex photochemical reaction mechanisms in solution. We have used two recent developments, ultrafast mega-electron-volt electron sources and vacuum compatible sub-micron thick liquid sheet jets, to enable liquid-phase ultrafast electron diffraction (LUED). We have demonstrated the viability of LUED by investigating the photodissociation of tri-iodide initiated with a 400 nm laser pulse. This has enabled the average speed of the bond expansion to be measured during the first 750 fs of dissociation and the geminate recombination to be directly captured on the picosecond time scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.

Wang, Haipeng↗

Decimetric gyrosynchrotron emission during a solar flare

A decimetric, microwave, and hard X-ray burst was observed during a solar flare in which the radio spectrum below peak flux fits an f+2 power law over more than a decade in frequency. The spectrum is interpreted to mean that the radio emission originated in a homogeneous, thermal, gyrosynchrotron source. This is the first time that gyrosynchrotron radiation has been identified at such low decimetric frequencies (900-998) MHz). The radio emission was cotemporal with the largest single hard X-ray spike burst ever reported. The spectrum of the hard X-ray burst can be well represented by a thermal bremsstrahlung function over the energy range from 30 to 463 keV at the time of maximum flux. The temporal coincidence and thermal form of both the X-ray and radio spectra suggest a common source electron distribution. The unusual low-frequency extent of the single-temperature thermal radio spectrum and its association with the hard X-ray burst imply that the source had an area approx. 10(18) sq cm a temperature approx 5x10(8) K, an electron density approx. 7.10(9) cu cm and a magnetic field of approx. 120 G. H(alpha) and 400-800 MHz evidence suggest that a loop structure of length 10,000 km existed in the flare active region which could have been the common, thermal source of the observed impulsive emissions.

Batchelor, D. A.↗

Spontaneous-Desorption Ionizer for a TOF-MS

A time-of-flight mass spectrometer (TOF-MS) like the one mentioned in the immediately preceding article has been retrofitted with an ionizer based on a surface spontaneous-desorption process. This ionizer includes an electron multiplier in the form of a microchannel plate (MCP). Relative to an ionizer based on a hot-filament electron source, this ionizer offers advantages of less power consumption and greater mechanical ruggedness. The current density and stability characteristics of the electron emission of this ionizer are similar to those of a filament-based ionizer. In tests of various versions of this ionizer in the TOF-MS, electron currents up to 100 nA were registered. Currents of microamperes or more - great enough to satisfy requirements in most TOFMS applications - could be obtained by use of MCPs different from those used in the tests, albeit at the cost of greater bulk. One drawback of this ionizer is that the gain of the MCP decreases as a function of the charge extracted thus far; the total charge that can be extracted over the operational lifetime is about 1 coulomb. An MCP in the ion-detector portion of the TOF-MS is subject to the same limitation.

Schultz, J. Albert↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo modeling of spin-polarized photoemission from p -doped bulk GaAs

Here, the anticorrelation between quantum efficiency (QE) and electron spin polarization (ESP) from a ρ-doped GaAs activated to negative electron affinity is studied in detail using an ensemble Monte Carlo approach. The photoabsorption, momentum and spin relaxation during transport, and tunneling of electrons through the surface potential barrier are modeled to identify fundamental mechanisms, which limit the efficiency of GaAs spin-polarized electron sources. In particular, we study the response of QE and ESP to various parameters, such as the photoexcitation energy, doping density, and electron affinity level. Our modeling results for various transport and emission characteristics are in good agreement with available experimental data. Our findings show that the behavior of both QE and ESP at room temperature can be fully explained by the bulk relaxation mechanisms and the time that electrons spend in the material before being emitted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planetary and satellite x ray spectroscopy: A new window on solid-body composition by remote sensing

The rings and most of the satellites of the outer planets orbit within the radiation belts of their parent bodies. This is an environment with intense fluxes of energetic electrons. As a result, these objects are strong emitters of X-rays. The characteristic X-ray lines from these bodies depend on atomic composition, but they are not sensitive to how the material is arranged in compounds or mixtures. X-ray fluorescence spectral analysis has demonstrated its unique value in the laboratory as a qualitative and quantitative analysis tool. This technique has yet to be fully exploited in a planetary instrument for remote sensing. The characteristic X-ray emissions provide atomic relative abundances. These results are complementary to the molecular composition information obtained from IR, visible, and UV emission spectra. The atomic relative abundances are crucial to understanding the formation and evolution of these bodies. They are also crucial to the proper interpretation of the molecular composition results from the other sensors. The intensities of the characteristic X-ray emissions are sufficiently strong to be measured with an instrument of modest size. Recent developments in X-ray detector technologies and electronic miniaturization have made possible space-flight X-ray imaging and nonimaging spectrometers of high sensitivity and excellent energy resolution that are rugged enough to survive long-duration space missions. Depending on the application, such instruments are capable of resolving elemental abundances of elements from carbon through iron. At the same time, by measuring the bremsstrahlung intensity and energy spectrum, the characteristics of the source electron flux can be determined. We will discuss these concepts, including estimated source strengths, and will describe a small instrument capable of providing this unique channel of information for future planetary missions. We propose to build this instrument using innovative electronics packaging methods to minimize size and weight.

Chenette, D. L.↗

Energy transport by energetic electrons released during solar flares. I - Thermal versus nonthermal processes

The propagation of energetic electrons through a flaring flux tube is studied in an attempt to determine how the energy of the electrons is deposited in the flux tube. One-dimensional electrostatic particle simulations are used in the present investigation. As the energetic electrons propagate into the system, a return current of ambient plasma electrons and some of the energetic electrons is drawn into the energetic electron source. It is found that, as the ambient temperature relative to the ion temperature increases above about 3, the heated return-current electrons can excite ion-sound waves.

Winglee, R. M.↗

Experimental SF6/-//SF6 and Cl/-//CFC13 electron-attachment cross sections in the energy range 0-200 meV

Experimental cross sections for the electron-attachment processes for SF6(-)/SF6 and Cl(-)/CFl3 are reported in the energy range 0-200 meV by normalizing each attachment line shape to measurement of a thermal rate coefficient. When the same ion states are detected, good agreement is found between present values, for which a monoenergetic electron source is used, and swarm-unfolded results. The present data constitute a new limit for cross sections reported at high resolution at the lowest electron energy.

Chutjian, A.↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Manipulating the Second Coordination Shell of Single-Atom Fe for Enhanced Fenton Reaction

While current methods use oxidizable metals as electron donors to effectively reduce Fe 3+ , they suffer from the irreversible oxidation of these metals, ultimately compromising the catalyst’s longevity. To address this challenge, we engineered the second coordination shell of a single-atom Fe center by doping boron (B) onto a graphene-based support (Fe 1 /B-graphene) and utilized H 2 O 2 as the electron source for efficient Fe 2+ regeneration. Experimental results, supported by theoretical calculations, revealed that the Fe–O–B motif functions like a micro galvanic cell, with intermediary O atoms facilitating electron transfer between electrodes. Specifically, electrons consumed during H 2 O 2 activation at Fe 1 sites (positive electrode) are replenished by electrons extracted from H 2 O 2 at B atoms (negative electrode), where the activation energy for H 2 O 2 oxidation is significantly lower than that at Fe 1 sites. This study offers inspirational insights into the design of Fenton catalysts through precise regulation of the second coordination shell, demonstrating the potential of tailoring the outer coordination environment of single-atom catalysts to enhance catalytic performance across various reactions.

36 MATERIALS SCIENCE↗

Theoretical Coupling of Free-Flowing Ions and Magnetically Insulated Electrons

Magnetic insulation of electrons prevents losses and can be applied to generating radiation or electron sources for high current and high power applications. Ion emission from the anode may degrade magnetic insulation. We develop equilibrium theory, self-consistently coupling magnetically insulated electron flow with free-flowing injected ions. Generally, ion injection is self-limiting from space charge; however, once insulation strength drops below about 1.2x the magnetic insulation threshold, ion space-charge limits vanish. Further, the gap effectively short-circuits and the electron flow layer asymptotically approaches the anode. In this regime a quasineutral, nonthermal plasma manifests, effectively reducing gap distance and suggesting quasiequilibrium gap closure evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗

The multiple applications of electrons in space

An electron source such as a simple cathode is a cheap and light device which can serve several technological and scientific purposes in space: (1) electrostatic charging of a spacecraft can be limited by releasing electrons accumulated on the conductive elements of their surface; (2) the erosion of conductive coatings and the ability of conductive paints to withstand the space environment can be evaluated by monitoring the flow of charged particles impinging on their surface; (3) measuring the current collected by the spacecraft surface as a function of its potential with respect to an emitter is a very sensitive diagnostic technique which can yield a number of plasma parameters, such as density and temperature; (4) it is possible to convert the thermal motion of space plasmas into electrical energy by collecting energetic electrons and returning them to the medium as cold particles; (5) a wave in a plasma is characterized by a conduction current density which gives rise to fluctuations of the current flowing to the surface.

Grard, R. J. L.↗