Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Quantum efficiency, photoemission energy spectra, and mean transverse energy of ultrananocrystalline diamond photocathode

The quantum efficiency and mean transverse energy of electrons emitted from a cathode determine the quality of beams generated from photoinjectors. The nitrogen-incorporated ultrananocrystalline diamond, (N)UNCD, is a new class of robust semiconductor photocathodes, which has been considered in photoinjectors for high peak current extraction. In this work, we measure the spectral response in quantum efficiency, photoemission energy spectra, and mean transverse energy of the (N)UNCD photocathode using a photoemission electron microscope. The observed quantum efficiency was comparable to that of copper photocathodes. Photoemission spectra showed the evidence of scattering of electrons before emission. This relaxation of electrons due to scattering is also observed in the spectral response of the mean transverse energy. The mean transverse energy is limited to ∼70 meV at the threshold. We attribute this to the physical and chemical roughness of the (N)UNCD photocathode and, hence, smoother films will be required to further reduce the mean transverse energy obtained from the (N)UNCD photocathode.

Kachwala, A. (ORCID:0000000301756478)↗

Nanoscale mapping of point defect concentrations with $\mathrm{4D-STEM}$

Vacancies are missing atoms in a crystalline material, and occur both at equilibrium (varying with temperature) and out of equilibrium such as when crystalline materials are damaged with radiation or corrosion. While we know of their importance, particularly regarding diffusive mechanisms, it is not straightforward to experimentally measure their concentration or to visualize them directly. Traditionally, measurements such as positron annihilation spectroscopy and to some degree X-ray diffraction can measure average concentrations, but generally lack the ability to visualize or quantify a heterogenous concentration of vacancies that can occur at the level of individual defects and microstructural features. Here, we present a method to map vacancy concentrations and their distribution using local lattice parameter measurements with a high-resolution electron microscope. Our method utilizes a Au thin film as a model to demonstrate the method via four-dimensional scanning transmission electron microscopy (4D-STEM) by correlating the differences between changes in lattice parameter and the volumetric thermal expansion during in situ heating experiments. The vacancy mapping methodology is also applied to non-equilibrium defects accumulated in pure Al via knock-on electron beam irradiation. Our method demonstrates the ability to map point defect concentrations in heterogeneous systems in situ with nanometer spatial resolution. The result is a technique that can provide direct measurements of vacancy concentrations at the level of individual defects in studies of materials in and out of equilibrium.

36 MATERIALS SCIENCE↗

I-V curve analysis of single-nanoparticle Al-doped SrTiO 3

Strontium Titanate (SrTiO 3 or STO) is an oxide-semiconductor material which shows promise for photocatalytic water splitting, but remains poorly understood. To better understand its carrier dynamics, STO nanoparticles deposited onto an Au substrate were placed inside of a Scanning Electron Microscope (SEM) and then contacted with an Au probe. Current-voltage (I-V) measurements were taken with and without electron beam illumination. Fitting to the curves, we estimate the doping density ($N_D \approx 10^{22.1 \pm 1.2}$ cm$^{-3}$) and built-in potential ($\phi_{bi} \approx 0.84 \pm 0.45$ eV). We then used these I-V measurements to estimate the diffusion time ($\tau$) of our samples and observed an exponential dependence of $\tau$ on sample size in the range of 350-550 nm.

36 MATERIALS SCIENCE↗

Machine Learning-Enabled Quantitative Analysis of Optically Obscure Scratches on Nickel-Plated Additively Manufactured (AM) Samples

Additively manufactured metal components often have rough and uneven surfaces, necessitating post-processing and surface polishing. Hardness is a critical characteristic that affects overall component properties, including wear. This study employed K-means unsupervised machine learning to explore the relationship between the relative surface hardness and scratch width of electroless nickel plating on additively manufactured composite components. The Taguchi design of experiment (TDOE) L9 orthogonal array facilitated experimentation with various factors and levels. Initially, a digital light microscope was used for 3D surface mapping and scratch width quantification. However, the microscope struggled with the reflections from the shiny Ni-plating and scatter from small scratches. To overcome this, a scanning electron microscope (SEM) generated grayscale images and 3D height maps of the scratched Ni-plating, thus enabling the precise characterization of scratch widths. Optical identification of the scratch regions and quantification were accomplished using Python code with a K-means machine-learning clustering algorithm. The TDOE yielded distinct Ni-plating hardness levels for the nine samples, while an increased scratch force showed a non-linear impact on scratch widths. The enhanced surface quality resulting from Ni coatings will have significant implications in various industrial applications, and it will play a pivotal role in future metal and alloy surface engineering.

36 MATERIALS SCIENCE↗

Preferential hole defect formation in monolayer W Se 2 by electron-beam irradiation

Monolayer transition-metal dichalcogenides (TMDCs) have been extensively studied due to their wide range of physical properties and applications. It has been demonstrated that the electron beam in a transmission electron microscope (TEM) or scanning TEM (STEM) generates chalcogen vacancies that agglomerate into dispersed linelike or holelike defects. Here we employ a STEM electron beam and demonstrate that, in WSe 2 , beam-induced chalcogen vacancies initially form certain dispersed multivacancy structures, as seen in TMDCs in prior work. However, with suitable control of the STEM focused electron beam, these multivacancies gradually evolve into a dense network of ten-, 12-, 14-, and 16-member ring round holes, whereas the same process leads predominantly to chalcogen-vacancy line defects in other trigonal-prismatic TMDCs. Density functional theory calculations find that the underlying atomic-scale processes lead preferentially to defect structures that lower the total energy so that we are able to track the formation of the observed multivacancy complexes, which then lead to the formation of dense large round holes in WSe 2 . The same processes in WS 2 , however, are energetically unfavorable, while linear multivacancy defects are preferred, as observed. The demonstrated control of the formation of unique high-density round holes in WSe 2 has potential for applications such as atomic and molecular sieving.

36 MATERIALS SCIENCE↗

The Atomic Drill Bit: Precision Controlled Atomic Fabrication of 2D Materials

The ability to deterministically fabricate nanoscale architectures with atomic precision is the central goal of nanotechnology, whereby highly localized changes in the atomic structure can be exploited to control device properties at their fundamental physical limit. Here, an automated, feedback-controlled atomic fabrication method is reported and the formation of 1D–2D heterostructures in MoS 2 is demonstrated through selective transformations along specific crystallographic orientations. The atomic-scale probe of an aberration-corrected scanning transmission electron microscope (STEM) is used, and the shape and symmetry of the scan pathway relative to the sample orientation are controlled. The focused and shaped electron beam is used to reliably create Mo 6 S 6 nanowire (MoS-NW) terminated metallic-semiconductor 1D–2D edge structures within a pristine MoS 2 monolayer with atomic precision. From these results, it is found that a triangular beam path aligned along the zig-zag sulfur terminated (ZZS) direction forms stable MoS-NW edge structures with the highest degree of fidelity without resulting in disordering of the surrounding MoS 2 monolayer. Density functional theory (DFT) calculations and ab initio molecular dynamic simulations (AIMD) are used to calculate the energetic barriers for the most stable atomic edge structures and atomic transformation pathways. These discoveries provide an automated method to improve understanding of atomic-scale transformations while opening a pathway toward more precise atomic-scale engineering of materials.

2D materials↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

EIC Yellow Report

he Electron-Ion Collider (EIC) is a new, innovative, large-scale particle accelerator conceived by U.S. nuclear physicists over two decades and planned for construction at Brookhaven National Laboratory on Long Island, New York by the U.S. Department of Energy in the 2020s. The EIC will study protons, neutrons and atomic nuclei with the most powerful electron microscope ever built, in terms of its unique versatility of resolving power and intensity. The resolution and intensity is achieved by colliding high-energy electrons with high-energy protons or (a range of different) ion beams. The EIC provides the capability of colliding beams of polarized electrons with polarized beams of light ions, and this all at high intensity. The EIC was established as the highest priority for new construction in the 2015 US Nuclear Physics Long Range Plan, was favorably endorsed by a committee established by the National Academy of Sciences in 2018 to assess the science case. In December 2019, the EIC was granted Critical Design Zero by the US Department of Energy, which launched the EIC as an official project of the US government

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strain-modulated anisotropic electronic structure in superconducting RuO 2 films

The binary ruthenate, RuO 2 , has been the subject of intense interest due to its itinerant antiferromagnetism and strain-induced superconductivity. The strain mechanism and its effect on the microscopic electronic states leading to the normal and superconducting state, however, remain undisclosed. Here, we investigate highly strained epitaxial (110) RuO 2 films using polarization-dependent oxygen K-edge x-ray absorption spectroscopy (XAS). Through the detection of pre-edge peaks arising from O:2p - Ru:4d hybridization, we uncover the effects of epitaxial strain on the orbital/electronic structure near the Fermi level. Our data show robust strain-induced shifts of orbital levels and a reduction of hybridization strength. Furthermore, we reveal a pronounced in-plane anisotropy of the electronic structure along the [110] / [1$\bar{1}$0] directions naturally stemming from the symmetry-breaking epitaxial strain of the substrate. The B 2g symmetry component of the epitaxially enforced strain breaks a sublattice degeneracy, resulting in an increase of the density of states at the Fermi level (E F ), possibly paving the way to superconductivity. Finally, these results underscore the importance of the effective reduction from tetragonal to orthorhombic lattice symmetry in (110) RuO 2 films and its relevance towards the superconducting and magnetic properties.

36 MATERIALS SCIENCE↗

X-ray Spectrometry in the Era of Aberration-Corrected Electron Optical Beam Lines

Abstract Aberration correction in the analytical transmission electron microscope is most closely associated with improvements in high-resolution imaging. In this paper, the combination of that technology with new system designs, which optimize both electron optics and x-ray detection, is shown to provide more than a tenfold increase in performance over the last 25 years.

Zaluzec, Nestor J. (ORCID:0000000248573487)↗

Synthesis of Narrow SnTe Nanowires Using Alloy Nanoparticles

Topological crystalline insulator tin telluride (SnTe) provides a rich playground to examine interactions of correlated electronic states, such as ferroelectricity, topological surface states, and superconductivity. The study of SnTe nanowires may lead to even richer physics owing to the one-dimensional (1D) confinement effect and an increased contribution from the topological surface states. Thus, for transport measurements, SnTe nanowires must be synthesized with reduced diameters and high crystalline quality to ensure 1D confinement and phase coherence of the topological surface electrons. Here, we report a facile growth method to produce narrow SnTe nanowires with a high yield using alloy nanoparticles as growth catalysts. The average diameter of the SnTe nanowires grown using alloy nanoparticles is 85 nm, nearly a factor of three reduction compared to the average diameter of 240 nm when using gold nanoparticles as growth catalysts. Transport measurements reveal the effect of the nanowire diameter on the residual resistance ratio and magnetoresistance. Particularly, the ferroelectric transition temperature for SnTe evolves systematically with the nanowire diameter. In situ cryogenic cooling of narrow SnTe nanowires in a transmission electron microscope directly reveals the cubic to rhombohedral structural transition, which is associated with the ferroelectric transition. Thus, these narrow SnTe nanowires represent a model system to study electronic states arising from 1D confinement, such as 1D topological superconductivity and potential multiband superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy

Liquid cell transmission electron microscopy allows for imaging of samples in a fully hydrated state at high resolution and has the potential for visualizing static or dynamic biological structures. However, the ionizing nature of the electron beam makes it difficult to discern real physiological dynamics from radiation induced artifacts within liquid cell samples. Electron flux thresholds for achieving high resolution structures from biological samples frozen in ice have been described extensively by the cryo-electron microscopy field, while electron flux thresholds which do not result in a functional change for biological samples within the hydrated environment of a transmission electron microscope liquid cell is less clear. Establishing these functional thresholds for biologically relevant samples is important for accurate interpretation of results from liquid cell experiments. Here we demonstrate the electron damage threshold of fluorescently tagged lipid bilayers by quantifying the change in fluorescence before and after electron exposure. We observe the reduction of fluorescent signal in bilayers by 25% after only 0.0005 e − /Å 2 and a reduction of over 90% after 0.01 e − /Å 2 . These results indicate that the loss of function occurs at irradiation thresholds far below a typical single high resolution (scanning) transmission electron microscopy image and orders of magnitude below fluxes used for preserving structural features with cryo-electron microscopy.

Moser, Trevor↗

Toward nonthermal control of excited quantum materials: framework and investigations by ultrafast electron scattering and imaging

Quantum material systems upon applying ultrashort laser pulses provide a rich platform to access excited material phases and their transformations that are not entirely like their equilibrium counterparts. The addressability and potential controls of metastable or long-trapped out-of-equilibrium phases have motivated interests both for the purposes of understanding the nonequilibrium physics and advancing the quantum technologies. Thus far, the dynamical spectroscopic probes eminently focus on microscopic electronic and phonon responses. For characterizing the long-range dynamics, such as order parameter fields and fluctuation effects, the ultrafast scattering probes offer direct sensitivity. Bridging the connections between the microscopic dynamics and macroscopic responses is central toward establishing the nonequilibrium physics behind the light-induced phases. Here, we present a path toward such understanding by cross-examining the structure factors associated with different dynamical states obtained from ultrafast electron scattering, imaging, and modeling. We give the basic theoretical framework on describing the non-equilibrium scattering problems and briefly describe how such framework relates to the out-of-equilibrium phenomena. We give effective models outlining the emergences of nonthermal critical points, hidden phases, and non-equilibrium relaxational responses from vacuum-suspended rare-earth tritellurides, tantalum disulfides thin films, and vanadium dioxide nanocrystalline materials upon light excitations.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards On-Chip Learning for Low Latency Reasoning with End-to-End Synthesis

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application-Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frame-works), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This paper provides an overview of the flow in the context of the generation of accelerators for edge processing to be integrated in transmission electron microscopy (TEM) devices, focusing on use cases from precision material synthesis. We show the tool in action with an example of design space exploration for inference on reconfigurable devices with a conventional deep neural network model (LeNet). Finally, we discuss the research directions and opportunities enabled by SODA in the area of autonomous control for scientific experimental workflows.

Castellana, Vito G.↗

Fabrication and characterization of boron-terminated tetravacancies in monolayer hBN using STEM, EELS and electron ptychography

Tetravacancies in monolayer hexagonal boron nitride (hBN) with consistent edge termination (boron or nitrogen) form triangular nanopores with electrostatic potentials that can be leveraged for applications such as selective ion transport and neuromorphic computing. In order to quantitatively predict the properties of these structures, an atomic-level understanding of their local electronic and chemical environments is required. Moreover, robust methods for their precision manufacture are needed. Here we use electron irradiation in a scanning transmission electron microscope (STEM) at a high dose rate to drive the formation of boron-terminated tetravacancies in monolayer hBN. Characterization of the defects is achieved using aberration-corrected STEM, monochromated electron energy-loss spectroscopy (EELS), and electron ptychography. Z-contrast in STEM and chemical fingerprinting by core-loss EELS enable identification of the edge terminations, while electron ptychography gives insight into structural relaxation of the tetravacancies and provides evidence of enhanced electron density around the defect perimeters indicative of bonding effects.

2D hBN↗

Studies of Conventional and ERL-Based Re-Circulator Electron Cooling for an Electron Ion Collider (Final Report)

The envisioned Electron Ion Collider will be comprised of a chain of accelerators, each employing electron cooling. Depending on the purpose, each accelerator will employ some form of electron cooling: conventional DC type, Energy Recovering Linac-based recirculator, or coherent electron cooling. Each electron cooling type has its own peculiarities that need to be studied, understood, and their performance optimized to maximize luminosity; these are the subjects of this project. In particular, we developed the first microscopic electron cooling modeling and simulation framework that was also benchmarked against experiment. We proved for the first time the feasibility of first principle, accurate and efficient electron cooling simulations with a minimal number of assumptions and approximations that match empirical studies.

43 PARTICLE ACCELERATORS↗

Start-to-end self-consistent simulation of the UEM beamline

Addressing the preliminary design review report of the ultrafast electron microscope (UEM), start-to-end self-consistent simulations were carried out to explore fundamental aspects affecting the resolution (space-charge effects, energy spread, shot-to-shot energy jitter, contrast formation, etc.). The electron beam energy spread in the single-shot mode and the effective energy spread in the accumulation mode, equivalent to the convolution of the single-shot energy spread and shot-to-shot energy jitter, have been identified as the ultimate limits of the instrument resolution. A full self-consistent simulation from the photocathode to the detector is being performed using the GPT code to find out what resolution can be achieved. Preliminary results of the start-to-end simulations are reported in this note and the plan of further simulations is presented.

43 PARTICLE ACCELERATORS↗