Fractographic and microstructural evaluation of 3500-hour durability specimens

Long term durability testing of candidate ceramic materials for advanced gas turbine applications was performed. Specimens of the materials were exposed to combustion atmospheres under temperature cyclic conditions for times up to 3500 hours and at peak temperatures of 1200 and 1370 C. The specimen strengths after exposure were measured at room temperature and at 1200 C. In addition, a number of physical measurements were taken; however, no microstructural examination of the specimens was performed. Materials examined include: sintered alpha silicon carbide, sintered silicon nitride, and reaction bonded silicon nitride. Sample preparation techniques were developed to provide high quality thin-section specimens which can be examined by transmitted light or thinned using an ion mill for subsequent transmission electron microscopic examination. Specimen preparation techniques and the results of optical and electron microscopic examination of the reaction interfaces of the selected specimens are presented.

Miller, A. D.↗

Computer synthesis of high resolution electron micrographs

Specimen damage, spherical aberration, low contrast and noisy sensors combine to prevent direct atomic viewing in a conventional electron microscope. The paper describes two methods for obtaining ultra-high resolution in biological specimens under the electron microscope. The first method assumes the physical limits of the electron objective lens and uses a series of dark field images of biological crystals to obtain direct information on the phases of the Fourier diffraction maxima; this information is used in an appropriate computer to synthesize a large aperture lens for a 1-A resolution. The second method assumes there is sufficient amplitude scatter from images recorded in focus which can be utilized with a sensitive densitometer and computer contrast stretching to yield fine structure image details. Cancer virus characterization is discussed as an illustrative example. Numerous photographs supplement the text.

Nathan, R.↗

Micropaleontological studies of lunar and terrestrial precambrian materials

Optical microscopic and scanning electron microscopic studies of rock chips and dust returned by Apollo 14, 15, 16, and 17 are analyzed along with optical microscopic studies of petrographic thin sections of breccias and basalts returned by Apollo 14, 15, and 16. Results show no evidence of modern or fossil lunar organisms. The lunar surface is now, and apparently has been throughout the geologic past, inimical to known biologic systems.

Schope, J. W.↗

Research directed toward improved echelles for the ultraviolet

Research was undertaken to demonstrate that improved efficiencies for low frequency gratings are obtainable with the careful application of present technology. The motivation for the study was the desire to be assured that the grating-efficiency design goals for potential Space Telescope spectrographs can be achieved. The work was organized to compare gratings made with changes in the three specific parameters: the ruling tool profile, the coating material, and the lubricants used during the ruling process. A series of coatings and test gratings were fabricated and were examined for surface smoothness with a Nomarski Differential Interference Microscope and an electron microscope. Photomicrographs were obtained to show the difference in smoothness of the various coatings and rulings. Efficiency measurements were made for those test rulings that showed good groove characteristics: smoothness, proper ruling depth, and absence of defects. The intuitive feeling that higher grating efficiency should be correlated with the degree of smoothness of both the coating and the grating is supported by the results.

Source record↗

The impact of defects on the photovoltaic potential of RTR silicon ribbon

Silicon ribbon grown at a high rate by the ribbon-to-ribbon (RTR) method contains a variety of defects and can exhibit an unusual dendritic morphology. This paper is a study of the effect of the defect structure and dendritic morphology on the photovoltaic potential of RTR ribbon. Defects found in RTR ribbon include grain boundaries, twin planes, stacking faults and dislocations. The electrical activity of these defects is investigated by measuring the diffusion length in the ribbon; by fabricating small area diodes on the ribbon and evaluating their photoresponse; and by using a scanning electron microscope in the electron beam induced current mode. It is concluded that although grain boundaries serve very effectively as recombination centers, they do not occur frequently enough in RTR ribbons to significantly affect the generation current. Dislocation densities up to 1,000,000/sq cm can be tolerated without strongly reducing the photoresponse. Similarly, linear boundaries such as twin planes or stacking faults do not affect the cell performance up to densities of 1000/sq cm.

Baghdadi, A.↗

Long-term thermal degradation and alloying constituent effects on five boron/aluminum composites

Thermal exposure effects on the properties of five boron/aluminum composite systems were experimentally investigated. The composite systems were 49 volume percent boron fibers (203 micron diameter) in aluminum-alloy matrices 1100 Al, 2024 Al, 3003 Al, 5052 Al, and 6061 Al. Specimens were thermally exposed up to 10,000 hours at 500 K and 590 K, up to 500 hours at 730 K, and up to 10,000 hours at 500 K and 590 K, up to 500 hours at 730 K, and up to 2000 thermal cycles between 200 K and 590 K. Composite longitudinal and transverse tensile strengths, longitudinal compression strength, and in-plane shear strength were determined. None of the systems was severely degraded by exposure at 590 K. The best performing system was B-2024 Al. Effects of matrix alloys on degradation mechanisms were experimentally investigated. Composite specimens and individual fibers were metallurgically analyzed with a scanning electron microscope and an electron microprobe to determine failure characteristics, chemical element distribution, and reaction layer morphology. Alloying constituents were found to be affect the composite degradation mechanisms as follows: alloys containing iron, but without manganese as a stabilizer, caused increased low-temperature degradation; alloys containing magnesium, iron, or manganese caused increased degradation; and alloys containing copper caused increased fiber strength.

Olsen, G. C.↗

Surface recombination velocity measurement for silicon solar cells

For the design and fabrication of silicon solar cells approaching theoretical ultimate conversion efficiencies, surface recombination velocity plays a crucial role. A technique using a scanning electron microscope with pulsed electron beam has been developed for thy measurement of this important parameter for silicon surfaces. It is shown that the surface recombination velocity(s) increases by an order of magnitude when a freshly etched sample is left out for a few hours, presumably due to generation of surface states. A textured front surface field (FSF) cell with a high-low junction near the surface shows the effect of minority carrier reflection and an apparent reduction of s, whereas a tandem junction (TJ) cell with n+-p junction near the surface gives larger s value.

Daud, T.↗

EBIC spectroscopy - A new approach to microscale characterization of deep levels in semi-insulating GaAs

The microscale characterization of electronic defects in (SI) GaAs has been a challenging issue in connection with materials problems encountered in GaAs IC technology. The main obstacle which limits the applicability of high resolution electron beam methods such as Electron Beam-Induced Current (EBIC) and cathodoluminescence (CL) is the low concentration of free carriers in semiinsulating (SI) GaAs. The present paper provides a new photo-EBIC characterization approach which combines the spectroscopic advantages of optical methods with the high spatial resolution and scanning capability of EBIC. A scanning electron microscope modified for electronic characterization studies is shown schematically. The instrument can operate in the standard SEM mode, in the EBIC modes (including photo-EBIC and thermally stimulated EBIC /TS-EBIC/), and in the cathodo-luminescence (CL) and scanning modes. Attention is given to the use of CL, Photo-EBIC, and TS-EBIC techniques.

Li, C.-J.↗

Electron beam analysis of particulate cometary material

Electron microscopy will be useful for characterization of inorganic dust grains in returned comet nucleus samples. The choice of instrument(s) will depend primarily on the nature of the samples, but ultimately a variety of electron-beam methods could be employed. Scanning and analytical (transmission) electron microscopy are the logical choise for morphological, mineralogical, and bulk chemical analyses of dust grains removed from ices. It may also be possible to examine unmelted ice/dust mixtures using an environmental scanning electron microscope equipped with a cryo-transfer unit and a cold stage. Electron microscopic observations of comet nuclei might include: (1) porosities of dust grains; (2) morphologies and microstructures of individual mineral grains; (3) relative abundances of olivine, pyroxene, and glass; and (4) the presence of phases that might have resulted from aqueous alteration (layer silicates, carbonates, sulfates).

Bradley, John↗

Jellyfish: Special Tools for Biological Research on Earth and in Space

The most intriguing nature of the jellyfish polyps is their ability to metamorphose, giving rise to tiny immature medusae called ephyrae which have a different form or shape from the polyps. The Aurelia Metamorphosis Test System was used to determine the subtle effects of hydrocarbons found in oil spills and the effects of X-irradiation on developing ephyrae. Currently, this test system is used to determine the effects of the gravity-less environment of outer space on the development and behavior of ephyrae. For this purpose, the effects of clinostat rotation on development of the ephyrae and their gravity receptor are being studied. The behavior of the ephyrae during 0 gravity achieved for short intervals of 30 seconds in parabolic flight is examined. The developing ephyrae and the mature ephyrae are exposed to gravity-less environment of outer space via a six or seven day shuttle experiment. If gravity receptors do form in outer space, they will be studied in detail using various types of microscopes, including the electron microscope, to determin whether they developed normally in space as compared with control on Earth.

Spangenberg, Dorothy B.↗

Collection and Analysis of Aircraft Emitted Particles

The University of Denver Aerosol Group proposed to adapt an impactor system for the collection of particles emitted by aircraft. The collection substrates were electron microscope grids which were analyzed by Dr. Pat Sheridan using a transmission electron microscope. The impactor was flown in the SNIFF behind aircraft and engine emissions were sampled. This report details the results of that work.

Wilson, James Charles↗

Sub-Micrometer Scale Minor Element Mapping in Interplanetary Dust Particles: A Test for Stratospheric Contamination

Combined X-ray microprobe (XRM), energy dispersive x-ray fluorescence using a Transmission Electron Microscope (TEM), and electron microprobe measurements have determined that the average bulk chemical composition of the interplanetary dust particles (IDPs) collected from the Earth s stratosphere is enriched relative to the CI meteorite composition by a factor of 2 to 4 for carbon and for the moderately volatile elements Na, K, P, Mn, Cu, Zn, Ga, Ge, and Se, and enriched to approximately 30 times CI for Br. However, Jessberger et al., who have reported similar bulk enrichments using Proton Induced X-ray Emission (PIXE), attribute the enrichments to contamination by meteor-derived atmospheric aerosols during the several weeks these IDPs reside in the Earth s atmosphere prior to collection. Using scanning Auger spectroscopy, a very sensitive surface analysis technique, Mackinnon and Mogk have observed S contamination on the surface of IDPs, presumably due to the accretion of sulfate aerosols during stratospheric residence. But the S-rich layer they detected was so thin (approximately 100 angstroms thick) that the total amount of S on the surface was too small to significantly perturb the bulk S-content of a chondritic IDP. Stephan et al. provide support for the contamination hypothesis by reporting the enrichment of Br on the edges of the IDPs using Time-of-Flight Secondary-Ion Mass-Spectrometry (TOFSIMS), but TOF-SIMS is notorious for producing false edge-effects, particularly on irregularly-shaped samples like IDPs. Sutton et al. mapped the spatial distribution of Fe, Ni, Zn, Br, and Sr, at the approximately 2 m scale, in four IDPs using element-specific x-ray fluorescence (XRF) computed microtomography. They found the moderately volatile elements Zn and Br, although spatially inhomogeneous, were not concentrated on the surface of any of the IDPs they examined, suggesting that the Zn and the Br enrichments in the IDPs are not due to contamination during stratospheric residence.

Flynn, G. J.↗

Microgravity mediated changes in phytoferritin accumulation in soybean root cap cells

Phytoferritin is an iron-protein complex analogous to the ferritin found in mammalian, bacteria and fungi cells. Phytoferritin molecules are large proteins, about 10.5 nm in diameter, visualised in an electron microscope as discrete, electron dense particles with iron-containing core, where several thousand atoms of iron lie within the proteinaceous shell (apoferritin). In higher plants, a plastid stroma is the site of phytoferritin storage. Phytoferritin is seen in all types of plastids. It is considered to be a mechanism used by cells to store iron in a non-toxic form. Phytoferritin-bound iron may subsequently be used to form iron-containing components. It was shown that low levels of phytoferritin are synthesised in normal green leaves, whereas chlorotic leaves do not have a measurable amount of phytoferritin and leaves of iron-loaded seedlings contain a high level of total iron, and phytoferritin well-filled by iron. Phytoferritin accumulation was observed in photosynthetic inactivity chloroplasts during senescence and disease. In this study we analised the effects of microgravity and ethylene on production of phytoferritin in the root cap columella cells of soybean seedlings.

short duration↗

Nanoscale Mineralogy and Composition of Experimental Regolith Agglutinates Produced under Asteroidal Impact Conditions

On the Moon, the energetics of smaller impactors and the physical/chemical characteristics of the granular regolith target combine to form a key product of lunar space weathering: chemically reduced shock melts containing optically-active nanophase Fe metal grains (npFe0) [1]. In addition to forming the optically dark glassy matrix phase in lunar agglutinitic soil particles [1], these shock melts are becoming increasingly recognized for their contribution to optically active patina coatings on a wide range of exposed rock and grain surfaces in the lunar regolith [2]. In applying the lessons of lunar space weathering to asteroids, the potential similarities and differences in regolith-hosted shock melts on the Moon compared to those on asteroids has become a topic of increasing interest [3,4]. In a series of impact experiments performed at velocities applicable to the asteroid belt [5], Horz et al. [6] and See and Horz [7] have previously shown that repeated impacts into a gabbroic regolith analog target can produce melt-welded grain aggregates morphologically very similar to lunar agglutinates [6,7]. Although these agglutinate-like particles were extensively analyzed by electron microprobe and scanning electron microscopy (SEM) as part of the original study [7], a microstructural and compositional comparison of these aggregates to lunar soil agglutinates at sub-micron scales has yet to be made. To close this gap, we characterized a representative set of these aggregates using a JEOL 7600 field-emission scanning electron microscope (FE-SEM), and JEOL 2500SE field-emission scanning transmission electron microscope (FE-STEM) both optimized for energy dispersive X-ray spectroscopy (EDX) compositional spectrum imaging at respective analytical spatial resolutions of 0.5 to 1 micron, and 2 to 4 nm.

Christoffersen, Roy↗

Surface micro-discharges on spacecraft dielectrics

Extensive measurements on Teflon and Kapton in a scanning electron microscope indicate the existence of a well-defined family of surface micro-discharges characteristic of the dielectric material. For a given small region exposed to the 16-20 kV electron beam, the strongest discharge pulses are similar in shape and amplitude. For Teflon, typical pulse durations are 2-3 ns, rise and fall times are sometimes as low as 0.2 ns, current amplitudes are approximately 100 mA flowing down to the pedestal and the pulses are unidirectional with no ringing. The use of a rapid-scan electron microscope with a secondary-electron imaging system reveals complex charge distributions resembling Lichtenberg figures on a supposedly flat homogeneous dielectric surface. These patterns undergo extensive alteration at each micro-discharge pulse and indicate that both the charging and discharging processes are highly nonuniform over the dielectric surface. The use of floodbeam causes the occurrence of a large-scale macro-discharges, in which a typical peak current is 40 A with a duration of 120 ns.

Balmain, K. G.↗

Determining Biosignatures by Complexity Analysis in Antarctic Cryptoendolithic Communities

One of the most difficult problems of life detection is that of identifying biosignatures across a wide range of scales using multiple co-registered probes. The technique should be of equal utility across a wide range of search spaces from remote sensors probing volumes of space or planetary surfaces, visual eye or camera searches across the surface of a rock in Antarctica, low resolution microscopic scanning of a rock or a space craft in situ, or high resolution electron microscope and computerized tomography scanning of geobiological samples. We describe here an approach to this problem which derives in large part from past work done in the area of astrophysics - namely the analysis of complexity in galactic signals by data compression methods. This approach is a radically new one for geobiology and astrobiology, and allows us to assess the complexity (and thus potential biogenicity) of an object being examined. This is done by considering the information within pixels of an image (regardless the sensor used to gather the information) as an energetic system capable of description in terms of classical thermodynamics. The image data space is searched by an algorithm that judges complexity via data compression (e.g., the more compressible it is, the less complex, and vice versa) and maximum entropy as originally outlined by Shannon. At present we are implementing methods to utilize images from multiple sensors gathering different kinds of information (e.g., visible gray-scale data, color analyses, UV fluorescence, chemical information, etc). We present here preliminary data from deep UV fluorescence and ESEM (Environmental Scanning Electron Microscope) images from a layered cryptoendolithic community of an Antarctic rock.

Storrie-Lombardi, M. C.↗

Pneumatic System for Concentration of Micrometer-Size Lunar Soil

A report describes a size-sorting method to separate and concentrate micrometer- size dust from a broad size range of particles without using sieves, fluids, or other processes that may modify the composition or the surface properties of the dust. The system consists of four processing units connected in series by tubing. Samples of dry particulates such as lunar soil are introduced into the first unit, a fluidized bed. The flow of introduced nitrogen fluidizes the particulates and preferentially moves the finer grain sizes on to the next unit, a flat plate impactor, followed by a cyclone separator, followed by a Nuclepore polycarbonate filter to collect the dust. By varying the gas flow rate and the sizes of various orifices in the system, the size of the final and intermediate particles can be varied to provide the desired products. The dust can be collected from the filter. In addition, electron microscope grids can be placed on the Nuclepore filter for direct sampling followed by electron microscope characterization of the dust without further handling.

McKay, David↗