Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electromagnetic transient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Library of Advanced Models of large-scale PV (LAMP) (Final Technical Report)

A suite of dynamic models of photovoltaic (PV) systems is developed in this project to accurately capture PV system dynamics during different contingencies. The following models are included: (i) quasi-dynamic, (ii) high-fidelity electromagnetic transient (EMT), (iii) advanced, and (iv) baseline. The models have the flexibility to consider different control functionalities at different controller levels. The study’s requirements determine the type of model needed. For example, high-fidelity EMT models are recommended for contingency studies. Advanced models are recommended for online or real-time implementations with resource constraints, whereas quasi-dynamic models are useful for studying the impact of weather variations.

14 SOLAR ENERGY↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Kilonovae Across the Nuclear Physics Landscape: The Impact of Nuclear Physics Uncertainties on r-process-powered Emission

Merging neutron stars produce “kilonovae”—electromagnetic transients powered by the decay of unstable nuclei synthesized via rapid neutron capture (the r-process) in material that is gravitationally unbound during inspiral and coalescence. Kilonova emission, if accurately interpreted, can be used to characterize the masses and compositions of merger-driven outflows, helping to resolve a long-standing debate about the origins of r-process material in the Universe. We explore how the uncertain properties of nuclei involved in the r-process complicate the inference of outflow properties from kilonova observations. Using r-process simulations, we show how nuclear physics uncertainties impact predictions of radioactive heating and element synthesis. For a set of models that span a large range in both predicted heating and final abundances, we carry out detailed numerical calculations of decay product thermalization and radiation transport in a kilonova ejecta with a fixed mass and density profile. The light curves associated with our models exhibit great diversity in their luminosities, with peak brightness varying by more than an order of magnitude. We also find variability in the shape of the kilonova light curves and their color, which in some cases runs counter to the expectation that increasing levels of lanthanide and/or actinide enrichment will be correlated with longer, dimmer, redder emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Panning for Gold: New Emission Lines from UV–VIS Spectroscopy of Au i and Au ii

The recent detection of a neutron star merger by the LIGO collaboration has renewed interest in laboratory studies of r-process elements. Accurate modeling and interpretation of the electromagnetic transients following the mergers requires computationally expensive calculations of both the structure and opacity of all trans-iron elements. To date, the necessary atomic data to benchmark structure codes are incomplete or, in some cases, absent entirely. Within the available laboratory studies, the literature on Au i and Au ii provides incomplete reports of the emission lines and level structures. We present a new study of Au i and Au ii lines and levels by exposing a solid gold target to plasma in the Compact Toroidal Hybrid (CTH) experiment at Auburn University. A wavelength range from 187 to 800 nm was studied. In Au i, 86 lines are observed, 43 of which are unreported in the literature, and the energies of 18 $5{d}^{9}6s6p$ levels and 16 of the 18 known $5{d}^{9}6s6d$ levels are corroborated by a least-squares level energy optimization. In Au ii, 76 emission lines are observed, and 51 of the lines are unreported in the literature. For both Au i and Au ii, the new lines predominantly originate from the most energetic of the known levels, and over half of the new Au ii lines have wavelengths longer than 300 nm. For the estimated electron parameters of CTH plasmas at the gold target (ne ~ 10 12 cm -3 , T e ~ 10 eV), two-electron transitions are similar in intensity to LS-allowed one-electron transitions.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A MIMO AAA Agorithm for Frequency Dependent Line Modeling

Modeling of power distribution system components that are valid for a wide range of frequencies are crucial for highly accurate modeling of electromagnetic transient (EMT) events. This has recently become of interest due to the improvements needed for the resilient operation of distribution systems. Vector fitting (VF) is a very popular and commonly used algorithm for wide band representations of power system components in EMT simulations. In this research, we present a new multi-input rational approximation algorithm (MIAAA) and illustrate its advantages with respect to VF using examples of approximations of admittance matrices discussed in the literature. We show that MIAAA not only outperforms VF in terms of achieving better accuracy using lesser number of poles, but also has no numerical issues achieving convergence. In contrast to VF, MIAAA is not sensitive to the location of input sample points and it does not require good estimates for the location of the desired approximation poles. The novelty of this research work is the use of recent mathematical results to solve existing challenges in distribution system modeling and to develop rational approximations for power system models that intend to be optimal in terms of accuracy and performance.

AAA algorithm↗

Modeling Distributed Energy Resources for Analyzing Distribution Systems with High Renewable Penetration: Preprint

Increasing levels of inverter-based distributed energy resources (IBDERs) impact the legacy overcurrent distribution protection systems. The fault current injections of IBDERs are limited to between 1-2 p.u. of the rated current. The combination of the limited fault current and varying system load makes it increasingly difficult to reliably set the overcurrent protection. To address this challenge, researchers are proposing adaptive overcurrent protection mechanisms that can adapt to changing system conditions. Accurate modeling of IBDERs is required to develop reliable protection schemes. This paper presents a photovoltaics-based IBDER model in OpenDSS for adaptive overcurrent protection. The paper presents the validation of the proposed IBDER model against a detailed model in electromagnetic transient programs. Protection analysis of the Electric Power Research Institute J1 feeder with the proposed IBDER model is also presented.

adaptive↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗