Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electro-optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Detection of amblyopia utilizing generated retinal reflexes

Investigation confirmed that GRR images can be consistently obtained and that these images contain information required to detect the optical inequality of one eye compared to the fellow eye. Digital analyses, electro-optical analyses, and trained observers were used to evaluate the GRR images. Two and three dimensional plots were made from the digital analyses results. These plotted data greatly enhanced the GRR image content, and it was possible for nontrained observers to correctly identify normal vs abnormal ocular status by viewing the plots. Based upon the criteria of detecting equality or inequality of ocular status of a person's eyes, the trained observer correctly identified the ocular status of 90% of the 232 persons who participated in this program.

Kerr, J. H.↗

Spatial, High-Accuracy, Positioning-Encoding Sensor (SHAPES) for large space system control applications

The Spatial, High-Accuracy, Position-Encoding Sensor is a controls sensor suitable for the determination of the static shape and vibrational motion of large space structures and similar systems and for the determination of position and velocity in rendezvous and docking. It uses a combination of electro-optical techniques to measure the three-dimensional coordinates distributed over the structure at reading rates high compared to the rates at which the coordinates are changing. The technical approach is that of measuring the distance to and the direction of points on the structure from a single sensor head. Many points can be measured simultaneously from a single head without significantly increasing the complexity of the system.

Mclauchlan, J. M.↗

Conceptual design study of a visual system for a rotorcraft simulator and some advances in platform motion utilization

A conceptual design of a visual system for a rotorcraft flight simulator is presented. Also, drive logic elements for a coupled motion base for such a simulator are given. The design is the result of an assessment of many potential arrangements of electro-optical elements and is a concept considered feasible for the application. The motion drive elements represent an example logic for a coupled motion base and is essentially an appeal to the designers of such logic to combine their washout and braking functions.

Sinacori, J. B.↗

The MSFC vector magnetograph

The NASA/Marshall Space Flight Center's solar vector magnetograph system allows measurements of all components of the Sun's photospheric magnetic field over a 5 x 5 or 2.5 x 2.5 arc min square field of view with an optimum time resolution of approximately 100 sec and an optimum signal-to-noise of approximately 1000. The basic system components are described, including the optics, detector, digital system, and associated electronics. Automatic sequencing and control functions are outlined as well as manual selections of system parameters which afford unique system flexibility. Results of system calibration and performance are presented, including linearity, dynamic range, uniformity, spatial and spectral resolutions, signal-to-noise, electro-optical retardation and polarization calibration.

Hagyard, M. J.↗

An automated mapping satellite system

Topographic maps are compiled by manually operated stereoplotters that recreate the geometry of two wide-angle overlapping stereo frame photographs. Continuous imaging systems such as strip cameras, electro-optical scanners, or linear arrays of detectors (push brooms) can also create stereo coverage from which topography can be compiled; however, the instability of an aircraft in the atmosphere makes this approach impractical. The benign environment of space permits a satellite to orbit the Earth with very high stability as long as no local perturbing forces are involved. Solid-state linear-array sensors have no moving parts and create no perturbing force on the satellite. Digital data from highly stabilized stereo linear arrays are amenable to simplified processing to produce both planimetric imagery and elevation data. A proposed satellite, called MAPSAT, could accomplish automated mapping in near real time. Image maps as large as 1:50,000 scale with contours as close as 20-m interval may be produced from MAPSAT data.

Colvocoreses, A. P.↗

Integrated optics technology study

The status and near term potential of materials and processes available for the fabrication of single mode integrated electro-optical components are discussed. Issues discussed are host material and orientation, waveguide formation, optical loss mechanisms, wavelength selection, polarization effects and control, laser to integrated optics coupling fiber optic waveguides to integrated optics coupling, sources, and detectors. Recommendations of the best materials, technology, and processes for fabrication of integrated optical components for communications and fiber gyro applications are given.

Chen, B.↗

In-flight deflection measurement of the HiMAT aeroelastically tailored wing

An electro-optical flight deflection measurement system was developed for NASA for use on the highly maneuverable aircraft technology (HiMAT) remotely piloted research vehicle (RPRV) to provide a means of evaluating the performance of the HiMAT's aeroelastically tailored composite wing and canard. A description of the flight deflection measurement system is presented from a user's viewpoint and includes the general method of operation, system capabilities and limitations, method of installation on the HiMAT vehicle, and calibration of targets. Also included is a general description of the HiMAT RPRV and its design goals. Preliminary flight deflection and bending moment data were obtained at Mach 0.8 and were extrapolated to the Mach 0.9 maneuver design condition for comparison to NASTRAN predictions and ground loads test results. The preliminary flight test results tended to agree with the results obtained from the static ground loads tests, that is, that the NASTRAN model overpredicted the streamwise twist of the composite outer wing panel.

Deangelis, V. M.↗

Vision Test in Seconds

Acuity Systems, Inc. developed an electro-optical instrument under a grant from NASA to measure the visual performance of pilots. Transferred from Ames Research Center, this instrument now allows you to have your eyes tested in seconds by relatively unskilled operators. The device automatically measures refractive error of eye and prints out proper prescription for glasses. The unit also detects cataracts and glaucoma.

Source record↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

A Method of Monitoring Non-Resonant Raman Lidar Returns During Daylight Hours

A method for using non-resonant Raman lidar during daytime hours is presented. A dual (or quadruple) arrangement of electro-optical channels is set up in the lidar receiver. Each channel contains its own optical spectral response as determined by an appropriate set of interference filters. The incoming signal is split and fed into two channels, filtered (simultaneously) and then inserted into the input terminals of an operational amplifier. The difference signal is selected and amplified whereas the common portion of the signal is highly attenuated (Common Mode Re.jection Ratio = 75-80db). For the present hardware, daylight intensities 10(exp 2)-10(exp 3) times Raman signals are received simultaneously. Mean values of intensities of daylight signals which give rise to a constant differences merely shift the value of the measured variable at the ground. These mean value signals have their common part highly attenuated. The differences of the fluctuation portions of the daylight signal represents a noise signal. Identical (space-time) optical paths for each component of the daylight signal produce the same fluctuational spectra in each channel. Hence noise levels, much less than signal levels, are anticipated. First a N2-H2 ) signal pair is differenced. Then an N2-O2 pair is differenced and used for instrumental normalization purposes. Signal levels to be encountered are quite well known as a result of prior field work. Improved optical design of laser system can reduce mean value of daylight intensities by 10(exp 2). Thus the mean daylight intensity can be set equal to the expected signal levels by more advanced optical design. Performance characteristics of photomultiplier pairs are discussed in this connection.

Cooney, John↗

Space applications.

Laser in space application, discussing electro- optical devices

ELECTRO-OPTICS↗