Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

DOE Zero Energy Ready Manufactured Housing: Subject Matter Expert Technical Assistance Summary

Manufactured homes offer American consumers an affordable option for decent single-family detached housing. For working-class American families in many U.S. markets, manufactured homes are the first step toward home ownership. They now make up 10% of all new homes constructed in the United States, with higher percentages in the south and in rural communities. To help encourage the production of homes that are more durable, healthy, efficient, and disaster resistant, the U.S. Department of Energy is bringing its building science research to the manufactured housing industry through DOE’s Zero Energy Ready Manufactured Home (ZER-MH) program, which provides technical assistance and voluntary guidelines to manufactured home builders. Homes built to these guidelines are better able to handle power outages and less likely to experience moisture issues, offering a better product option for American families. This higher quality is evidenced by energy modeling which shows homes manufactured to these voluntary guidelines will typically use half the energy of manufactured homes built to the current minimum requirements of the U.S. Department of Housing and Urban Development (HUD)’s Manufactured Housing and Construction Safety Standard (MHCSS). These homes can also reduce critical energy demand during the busiest hours of the day, typically late afternoon and early evening in the summer when air conditioning demand is highest and mornings in the winter when furnaces and heaters are heating up. Reducing electricity demand during these peak periods when electricity rates are at their highest reduces costs for American families while freeing up capacity on overburdened energy distribution networks. Builders participating in the DOE ZER-MH program are eligible for a tax incentive via the 45L tax credit, which helps to offset the costs of ZER-MH upgrades, enabling builders to offer these certified homes at no additional cost. Together these factors enable manufactured homes to offer home buyers a housing option that is both affordable to finance and affordable to operate, with lower monthly mortgage payments and lower monthly energy bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven method for electric vehicle charging demand analysis: Case study in Virginia

Electric vehicle (EV) adoption in the U.S. will be accelerated by the historic $7.5 billion public investments in EV charging infrastructure. Careful analysis of EV charging demands plays a vital role in understanding the energy requirements, power grid impact, and smart charging management opportunities of EVs. To this end, this paper develops a data-driven trip-chaining-based modeling framework including five steps: Trip data acquisition and preprocessing, EV adoption modeling, travel itinerary synthesis, EV charging demand simulation and EV load profile generation. The developed analysis framework was demonstrated using real-world data for one region in Virginia, U.S. The results show that the proposed modeling framework can work effectively. For the study region in 2040, the predicted number of plug-in EVs is 470,114, resulting in a weekly charging demand of 38,078,127 kWh (55% home, 9% work, and 36% public) in September and 45,920,358 kWh (61% home, 9% work, and 30% public) in February.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bench-Scale Development of Promoted High-Capacity Structured Sorbents (Final Technical Report)

The project objective was to develop high-capacity structured sorbent capable of achieving low CO 2 removal from air. The sorbent framework consists of an amine-functionalized onto hydrophobic polymer backbone with an added promoter. The functionalized amine provides high CO 2 capacity and adsorption rates and the polymer backbone to reduce water uptake. For the sorbent development, multiple functionalized amines and promoters were assessed to select a candidate that achieved high CO 2 capacity, high adsorption rate, and high stability. A sorbent-coated filter design was selected as the structured sorbent, which provides high sorbent loading capacity and contains an electrically conductive nonwoven filter substrate that can be Joule-heated to provide efficient utilization of available electricity for sorbent regeneration. A commercial partner operated a pilot filter manufacturing line to produce the filter panels coated with the developed sorbent. A 1 kg CO 2 /day bench unit was designed and fabricated to test the structured filter sorbent. The key achievements from the structured sorbent development activity were demonstrating that existing filter industrial-scale processes can be used for manufacturing Susteon’s structured sorbent and completing a proof-of-concept demonstration of the commercially manufactured structured sorbent filters for CO 2 capture from air with direct, Joule-heated regeneration. A techno-economic assessment with sensitivity analysis was conducted on a 100,000 TPY facility with 85% operating capacity. Through sorbent optimization and process design improvements, it is estimated that the cost of capture was reduced from $\$$349/tCO 2 to $\$$241/tCO 2 . The TEA projects further reductions to $165/tCO 2 through enhancements in CO 2 adsorption rate and sorbent capacity and reducing manufacturing and scale up risks. A life cycle analysis was conducted on the same 100,000 TPY facility and confirmed that the facility’s electricity demand drives its greenhouse gas impact. It was determined that electricity supplied through the current grid mix would result in net-positive CO 2 emissions and that achieving net-negative emissions is only possible by powering the system with renewable electricity or fossil fuel sources equipped with carbon capture and sequestration.

36 MATERIALS SCIENCE↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

2022 Standard Scenarios Report: A U.S. Electricity Sector Outlook

This report documents the eighth edition of the annual Standard Scenarios. It summarizes 70 forward-looking scenarios of the U.S. electricity sector that have been designed to capture a wide range of possible futures. In August 2022, the United States Congress passed the Inflation Reduction Act (IRA), a law aimed at accelerating U.S. decarbonization, clean energy manufacturing, and deployment of new power and end-use technologies. This year’s scenarios include representations of the main electricity-sector provisions from IRA and the potential impact on electricity demand. The Standard Scenarios are simulated using the Regional Energy Deployment System (ReEDS) model, which projects utility-scale electricity sector evolution for the contiguous United States using a system-wide, least-cost approach subject to policy and operational constraints. A subset of the scenarios are simulated in the PLEXOS production cost model to obtain a broader suite of metrics at the hourly resolution, which are made available through the National Renewable Energy Laboratory’s (NREL’s) annual Cambium data sets. The scenarios can be viewed and downloaded from NREL’s Scenario Viewer. Annual results are available for the full suite of scenarios in the Standard Scenarios projects in the viewer, whereas the Cambium projects contain hourly data for a subset of scenarios. The Standard Scenarios includes a scenario called the Mid-case, which has central or median values for core inputs such as technology costs and fuel prices, moderately paced demand growth averaging 1.3% per year, and electricity sector policies as they existed in September 2022 (including IRA). The remaining 69 scenarios are created by varying inputs such as technology and fuel prices, resource availability, demand growth, whether nascent generation technologies are allowed, and by introducing national decarbonization constraints.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Energy, Utility Scale: 30 Proven Strategies to Increase VPP Enrollment [Slides]

After decades of low or declining growth in electricity demand, the U.S. now faces a significant near-term need for new generation capacity and transmission and distribution infrastructure. Virtual Power Plants (VPPs) can meet a large portion of the gap between electricity supply and growing demand, but only if deployed at an increased scale. This study provides 30 proven strategies for scaling VPPs through increased enrollment based on in-depth interviews with utilities and VPP solutions providers that have achieved considerable scale or rapid growth in program deployment. The study includes specific actions for regulators, utilities, and VPP solutions providers to increase VPP enrollment and deliver important customer and utility benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonality and trade in hydro-heavy electricity markets: A case study with the West Africa Power Pool (WAPP)

Hydroelectric power plants account for 25% of West Africa's total installed capacity. In general, electricity generated by these plants is seasonal and intra-annual fluctuation has a considerable impact on electricity supply and cross-border electricity trade. We soft-linked a global hydrologic model to a multi-region capacity expansion and planning model for the West Africa Power Pool (WAPP) to examine the effects of seasonality in hydropower electricity generation on electricity trade, as well as the economic benefits of unconstrained cross-border electricity trade. We found that transitioning from rainy to dry season decreases hydroelectricity generation by an average of 40% in a normal year across the region. Between 2018 and 2050, satisfying the region's electricity demand will require significant capital investment; nevertheless, extending from current bilateral electricity trade agreements to a fully competitive cross-border electricity trade will result in net annual savings of $3 billion in 2015 USD. To achieve year-round energy security, countries should plan ahead and diversify their energy sources to ensure that supply reliability can be maintained in the case of lower supply during the dry season.

13 HYDRO ENERGY↗

Coupling of the Electricity and Transportation Sectors - Part I: Sector Overviews

“Sector coupling” is a concept that addresses potential designs for the future power industry. Traditionally, the energy sectors, i.e., electricity supply, transport, and industry, have functioned largely independently from one another. Thus, the concept of sector coupling means that the electricity sector would become the central pillar of the energy system, supplying the other sectors – transportation and industry – with energy in various ways, a scheme described by the term “Power-to-X”. This report delves into the ambitious goal set by the United States to achieve net-zero emissions by 2050, with a pivotal milestone of making half of all passenger vehicles sold in America zero-emission by 2030. Central to achieving this objective is the electrification of the transportation sector, resulting in complex interactions between this sector and the electric industry. As electric vehicles become more prevalent, a shift in the dependency on electricity for vehicle charging emerges, alongside a reduction in the electricity demand associated with maintaining the fossil fuel supply chain. Both the electricity and fossil fuel have been identified as critical infrastructure sectors, the transportation sector's historical reliance on fossil fuels, and the mature supply chain supporting them are explored. This study emphasizes the existing sectoral coupling between the electric energy and transportation sectors, extending beyond vehicle charging to essential operations at refineries, pipeline facilities, storage, and fuel extraction. Recognizing the critical dependency of fossil fuel supply chain operations on the electric sector, this research underscores the need for a comprehensive view of the evolving dynamics between the transportation and electric sectors. This study has been split into two segments, Part-I provides an overview of the existing fossil fuel supply chain architecture and the electrical sector. We provide an in-depth analysis of the grid-transportation sectoral coupling, its interactions, the vulnerabilities and essential take-aways that would help us to address them and apply towards an electrified transportation sector in the future. We engaged with stakeholders to understand their expectations in enabling an electrified transportation. We accumulate the understandings from the current fossil fuel-based system in developing a risk matrix, by identifying all the threats and vulnerabilities and how would they apply to both the current and future transportation systems in Part-II of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Evaluation of Energy Storage Potential of Unconventional Shale Reservoirs Using Numerical Simulation of Cyclic Gas Injection

Compressed air energy storage (CAES) stores energy as compressed air in underground formations, typically salt dome caverns. When electricity demand grows, the compressed air is released through a turbine to produce electricity. CAES in the US is limited to one plant built in 1991, due in part to the inherent risk and uncertainty of developing subsurface storage reservoirs. As an alternative to CAES, we propose using some of the hundreds of thousands of hydraulically fractured horizontal wells to store energy as compressed natural gas in unconventional shale reservoirs. To store energy, produced or “sales” natural gas is injected back into the formation using excess electricity and is later produced through an expander to generate electricity. To evaluate this concept, we performed numerical simulations of cyclic natural gas injection into unconventional shale reservoirs using cmg-gem commercial reservoir modeling software. We tested short-term (diurnal) and long-term (seasonal) energy storage potential by modeling well injection and production gas flowrates as a function of bottom-hole pressure. First, we developed a conceptual model of a single fracture stage in an unconventional shale reservoir to characterize reservoir behavior during cyclic injection and production. Next, we modeled cyclic injection in the Marcellus shale gas play using published data. Results indicate that Marcellus unconventional shale reservoirs could support both short- and long-term energy storage at capacities of 100–1000 kWe per well. The results indicate that energy storage in unconventional shale gas wells may be feasible and warrants further investigation.

25 ENERGY STORAGE↗

Analysis of Electrical Grid Capacity in Major U.S. Metropolitan Areas for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM) operations at scale with electric vertical takeoff and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles (EVs) over time. Under the worst-case assumption that each U.S. Metropolitan Statistical Area (MSA) can only access and utilize the electricity generated by power plants within its boundaries, it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the 25 most populous MSAs will decrease by about 61% from about 129,000 in the year 2021 to about 51,000 in the year 2050, due to the projected increase in ground EVs. Also, it is estimated that the number of these MSAs that may lack any available electrical grid power capacity for UAM operations will increase from zero MSAs in 2021 to eleven MSAs in 2050—including three MSAs that prospective UAM operators have announced as target markets (Los Angeles, Miami, and Orlando)—unless electricity demand for other purposes is reduced.

electrical grid↗

The Lithuania 100% Renewable Energy Study - Interim Results: Electricity System Scenarios for 2030 [Slides]

Lithuania's Energy Vision aims to achieve self-sufficiency in electricity generation by 2035 and transition to 100% renewable energy as soon as possible while maintaining affordability, reliability, and energy security. The Lithuania Energy Agency (LEA) is partnering with the National Renewable Energy Laboratory (NREL) to conduct the Lithuania 100% Renewable Energy Study (Lithuania 100) to provide evidence-based analysis for development of Lithuania's National Energy Independence Strategy. The Lithuania 100 Study leverages unique tools and capabilities of NREL to provide rigorous technical analysis of clean energy policies to achieve 100% renewable energy, and assess impacts on electricity grid operations, hydrogen system development, electricity distribution networks, air quality, and human health outcomes. The study is supported by a stakeholder committee chaired by the Ministry of Energy of Lithuania and implemented by four technical working groups. This report provides highlights of key interim results from modeling of Lithuania's near-term electricity grid through the year 2030. Results show that Lithuania has sufficient renewable energy potential, flexible generation capacity, and interconnection with neighboring European Union countries to reliably meet projected 2030 electricity demand with 100% renewable energy. A range of scenarios were modeled, each of which achieves at least 100% renewable energy in electricity, on average over the year, by 2030. Potential demands for hydrogen across industrial and transportation sectors were also evaluated, as well as the cost of hydrogen produced in Lithuania by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Stochastic Charging Station Deployment Model for Electrified Taxi Fleets in Coupled Urban Transportation and Power Distribution Networks

Metropolitansworldwide are increasingly adopting electric taxis (ET) to address concerns about transportation-related emissions. However, the widespread deployment of electric taxis presents challenges in terms of increased electricity demand and changing demand profiles. This transition impacts both the urban transportation network (TN) and the electricity power distribution network (PDN), highlighting the interdependence between these two systems. Here, in this paper, we propose a two-stage stochastic programming planning model that aims to optimize both the TN and PDN, enabling efficient deployment of charging stations and grid upgrades. Our model seeks to strike a balance between meeting ET drivers' charging preferences, minimizing the costs associated with infrastructure deployment and grid expansion, and harmonizing the coordination between the TN and PDN. Additionally, we explore the potential benefits of utilizing an autonomous ET fleet to enhance overall system performance.

33 ADVANCED PROPULSION SYSTEMS↗

What Is the Best Use of Biomass? A Harmonized LCA-TEA Framework Quantifying Economic and Environmental Metrics for Bioenergy Pathways

Bioresource utilization is expected to play a pivotal role in complementing existing energy pathways and enhancing energy resilience. This study develops a harmonized life cycle assessment (LCA) and techno-economic analysis (TEA) framework to evaluate the greenhouse gas (GHG) reduction potential, minimum fuel selling price (MFSP), and marginal abatement cost (MAC) of bioenergy pathways. We analyze 19 pathways, including liquid biofuels (via catalytic fast pyrolysis, Fischer–Tropsch synthesis, and gasification), bioelectricity, and biomass-to-hydrogen, with and without carbon capture and storage (CCS). The GHG impacts are assessed using the GREET 2022 model, while U.S. Billion-Ton 2016 biomass availability projections are used to estimate scale-up potential. Additionally, we evaluate the influence of a low-carbon electricity grid on pathway performance. Our results show that CCS implementation reduces carbon intensities (CI) to net-negative values for several pathways, with MAC ranging from $\$$32 to $\$$600 per metric ton (MT) CO2e avoided. Bioelectricity pathways with CCS achieve the lowest MAC ($\$$32–$\$$68/tCO2e), while liquid biofuels and hydrogen pathways remain critical for hard-to-abate sectors like aviation and heavy industry. Pathways with net-positive electricity demand benefit from a low-carbon grid, whereas those co-producing electricity experience increased MAC under lower electricity grid CI scenarios. This open-source framework provides a robust tool for harmonized evaluation of bioenergy pathways, enabling policymakers and stakeholders to identify cost-effective strategies for biomass utilization and carbon abatement at scale. The findings underscore the importance of CCS, co-product credits, and feedstock availability in optimizing bioenergy deployment for a low-carbon economy.

09 BIOMASS FUELS↗

Load Forecasting for the Moroccan Electricity Sector

The Moroccan electricity sector is undergoing rapid transformation as it seeks to increase its utilization of renewable energy from its abundant domestic supply. Key to implementing variable renewable energy is understanding current electricity demand and forecasting this demand on the long, medium, and short timescales. This report leverages existing Moroccan electricity sector data to build basic load forecasts on these timescales. Taking these forecasts, the report recommends next steps in terms of additional algorithms, mathematical models, data collection, and scenarios (such as vehicle electrification or high levels of distributed generation) that should be examined for advanced load forecasts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fleet-wide Electrification Impacts Assessment for the Valley Transportation Authority

This report explores the long-term electrification opportunities for the Valley Transit Authority’s (VTA) transit bus fleet. The potential for transit bus electrification at VTA as well as the economic impacts of partial and complete electrification are explored. We use the Revenue Operation and Device Optimization model to determine the optimal charging, operation and lowest capital and operating cost solution to achieve different levels of electrification to meet their existing routes. This study finds that, relying on only depot charging, around 70% of the daily trips by VTA’s transit bus fleet can be replaced with battery electric buses (BEBs) today. The benefits and drawbacks of five methods for improving the electrification potential beyond that achievable with only depot charging are discussed including (1) increase charger power, (2) purchase of larger vehicle batteries, (3) en-route charging, (4) purchasing additional buses and swapping them to enable the existing routes/blocks1 to be met, and (5) route/block redesign. A strategy is developed to enable full fleet electrification by increasing charger power or allowing intraday charging as a proxy for the options mentioned above. This method allows us to develop an understanding of the impacts and trade-offs of full fleet electrification. Two charging strategies are examined. Immediate charging, when the bus is charged as soon as it arrives at a depot or en-route charging station, and smart charging, which uses a controller to determine the best times to charge to achieve the lowest charging cost, while maintaining the same trip schedules. Smart charging is effective at reducing the peak power consumption, which can be reduced by between 31% and 65% compared to immediate charging. This translates directly to lower electricity demand charges and lower costs for possible distribution system upgrades. The total lifetime net present value (NPV) costs for different scenarios are presented in Figure ES-1. Scenarios are separated into three sections. The first stacked bar on the left is the base case (business-as-usual) where all buses are diesel hybrids, the next four bars include partial and full fleet electrification utilizing only immediate charging, and the last four bars include partial and full fleet electrification utilizing smart charging. The results show that smart charging scenarios are within ±4% of the lifetime NPV cost of the diesel-hybrid only (business-as-usual) scenario. The scenarios with full fleet electrification (i.e., including intraday charging) are 4% lower cost and those with partial fleet electrification (i.e., without intraday charging) are 2%–3% higher. However, it is important to note that the intraday charging scenarios do not include any additional costs for the equipment necessary to achieve intraday charging (e.g., additional chargers, larger batteries, new route design). Additionally, it is worth noting that the Low Carbon Fuel Standard (LCFS) credit received for implementing electric buses is essential to achieving these results.

33 ADVANCED PROPULSION SYSTEMS↗