Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Mechanistic understanding of aging behaviors of critical-material-free Li 4 Ti 5 O 12 //LiNi 0.9 Mn 0.1 O 2 cells with fluorinated carbonate-based electrolytes for safe energy storage with ultra-long life span

Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.

25 ENERGY STORAGE↗

Using In Situ High-Energy X-ray Diffraction to Quantify Electrode Behavior of Li-Ion Batteries from Extreme Fast Charging

Extreme fast charging (XFC, =15 min charging time) of Li-ion batteries (LIBs) has been proposed as an immediate target to increase the commercial appeal of electric vehicles. However, XFC of LIBs is associated with the degradation of battery performance and safety concerns. Quantitative and simultaneous characterization of various components during cell degradation represents a major experimental challenge. In this work, we outline a methodology for the use of spatially resolved, high-energy X-ray diffraction as a quantitative, in situ method of mapping the degradation of LIBs. We use this approach to study the battery cell capacity loss, both locally (mm scale) and globally over the entire cell (cm scale). Specifically, our workflow allows us to quantify the total amount of plated Li on the anode, as well as its spatial correlation to the structural properties of the anode and cathode. The method complements existing optical methods to resolve the spatial heterogeneity of local degradation mechanisms such as Li plating and provides simultaneous insights into concomitant anode state-of-charge variability. We apply it to commercially relevant single-layer pouch cells with the graphite anode and the LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathode. Our results show that Li plating occurs heterogeneously on the graphite anode and that it is spatially correlated to the extent of anode lithiation. In this work, we anticipate that the described workflow will allow for understanding multiscale degradation in energy-storage devices beyond LIBs, where quantitative analysis at a local and global length scale can be performed without the necessity to tear down the device, due to the applicability of high-energy X-rays to probe in situ degradation.

25 ENERGY STORAGE↗

Surface-Treated Composite Polymer as a Stable Artificial Solid Electrolyte Interphase Layer for Lithium Metal Anodes

Lithium (Li) metal batteries (LMBs) are one of the most promising high energy density batteries to meet the demands of electric transportation. However, the practical applications of LMBs are hindered by short cycle life and safety concern, mainly associated with side reactions between Li metal anode and liquid electrolyte and the growth of Li dendrites during cycling. In this study, we develop a stable artificial solid electrolyte interphase (aSEI), which consists of a surface-treated (S T ) PEO–Li 6.4 Ga 0.2 La 3 Zr 2 O 12 composite polymer coating layer (CPL) on Li metal anode. The developed aSEI is stable against selected electrolyte and enables a uniform electrodeposition of Li. Therefore, S T CPL@Li||LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cells exhibit improved cycling stability compared with bare Li||NMC811 cells at moderate to high current densities. Notably, using a 50 µm thick Li and a practical NMC811 cathode (~4.8 mAh cm -2 ), a capacity retention of 85% is obtained for S T CPL@Li||NMC811 cells at a current density of 2.4 mAcm -2 after 300 cycles compared with 24% for bare Li||NMC811 cells. Furthermore, S T CPL@Li||NMC811 cells demonstrate higher capacities at charge current densities of 2.4, 4.8 and 7.2 mAcm -2 compared with bare Li||NMC811 cells. Further, these findings suggest that S T CPL is promising for high current density practical LMBs.

25 ENERGY STORAGE↗

U.S. Effort Support to Examinations at Fukushima - Meeting Notes with Updated Information Requests (FY2020)

Much is still not known about the end-state of core materials in each unit that was operating on March 11, 2011 at the Fukushima Daiichi Nuclear Power Station (Daiichi). Information obtained from Daiichi is required to inform Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This document, which has been updated to include Fiscal Year 2020 (FY2020) information, summarizes results from a U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy (DOE-NE), is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Since its inception, comprehensive annual reports were issued that document significant safety insights being obtained in areas of special emphasis: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Reduced uncertainties in modeling the events at Daiichi improve the realism of reactor safety evaluations that inform future D&D activities. For FY2020, it was decided that the program would gain more benefit from a more concise report that emphasizes new information and insights that affect prior findings and recommendations from the U.S. experts participating in this effort. A key aspect of prior U.S. efforts, the updated list of information requests, is included in this letter report to ensure that they are transmitted to organizations within Japan. In addition, findings and associated recommendations are provided regarding information presented by TEPCO Holdings, Nuclear Damage Compensation and Decommissioning Facilitation Corporation (NDF), and the Japan Atomic Energy Agency (JAEA). This letter report also continues to emphasize how information obtained from the affected reactors at Daiichi has been and will continue to be used to update severe accident management strategies, improve maintenance activities (especially in areas of radiation protection) and reduce uncertainties in systems analysis code models. In addition, recommendations are included that would expand the use of this information to provide insights regarding maintenance, radiation protection, design, and siting activities of existing and new reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi- November 2020 Meeting Notes with Updated Information Requests

Much is still not known about the end-state of core materials in each unit that was operating on March 11, 2011 at the Fukushima Daiichi Nuclear Power Station (Daiichi). Information obtained from Daiichi is required to inform Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. commercial nuclear power plants. This document summarizes results from the Fiscal Year 2021 (FY2021) U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy (DOE-NE), is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Since its inception, annual reports were issued that document significant safety insights being obtained in areas of special emphasis: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Reduced uncertainties in modeling the events at Daiichi improve the realism of reactor safety evaluations that inform future D&D activities. A key aspect of prior U.S. efforts, the updated list of information requests, is included in this FY2021 report to ensure that they are transmitted to organizations within Japan. This report also continues to emphasize how information obtained from the affected reactors at Daiichi has been and will continue to be used to update severe accident management strategies and reduce uncertainties in systems analysis code models. In addition, recommendations are included that would expand the use of this information to provide insights regarding maintenance, radiation protection, design, and siting activities for existing and new reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi (November 2021 Meeting Notes with Updated Information Requests)

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. commercial nuclear power plants. This document summarizes results from the Fiscal Year 2022 (FY2022) U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy, is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Fukushima-related information and associated discussions during forensics meetings benefit operating, new, and advanced reactors. Significant safety insights are being obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. As discussed in this document, revised operator guidance was successfully used to improve operator response during a loss of off-site power event at the Duane Arnold Energy Center plant. Reduced uncertainties in modeling the events at Daiichi improve the realism of reactor safety evaluations that inform future D&D activities. U.S. evaluations of information from Fukushima and input regarding future examinations are of interest to several organizations within Japan. Meeting presentations by Japan describe how comments and recommendations documented in prior U.S. forensics effort reports, including consensus information requests developed by forensics effort participants, are considered in future Fukushima D&D activities. As discussed in this report, TEPCO Holdings considered these information requests in their D&D planning activities. An updated list of consensus information requests is included in this FY2022 report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lithium-Ion UPS Battery Research and Commentary

Lithium-ion batteries are increasingly prevalent in a variety of devices both small and large. The high level of stored energy in UPS battery racks is closely scrutinized because sudden, uncontrolled release of chemical and electrical energy could be an ignition source. With this in mind, lithium-ion battery safety is the subject of several testing standards, including UL 1642, UL 1973, and UL 9540A.The motivation for this research and commentary is the potential installation of lithium-ion batteries in a Vertiv UPS assembly for one of the buildings on the ORNL campus. The battery modules Vertiv uses are compliant with abuse survival testing, demonstrating that cells and modules are rugged. The modules are further compliant with fire propagation requirements – in the event a failure does produce a fire, it doesn’t spread. Beyond these, the rack level assemblies Vertiv sources comply with UL requirements to contain a fire within the rack.This three-tiered approach to battery safety suggests Vertiv’s lithium-ion UPS battery racks can reasonably be considered for use in a facility with appropriate fire protection provisions and an informed emergency response team.

25 ENERGY STORAGE↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - November 2022 Meeting Notes and Information Request Status

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. commercial nuclear power plants. This document summarizes results from the Fiscal Year 2023 (FY2023) U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy, is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Fukushima-related information and associated discussions during these meetings benefit operating, new, and advanced reactors. Significant safety insights have been and are continuing to be obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional benefits to the operating fleet and new LWR and non-LWR designs. U.S. evaluations of obtained examination information and input regarding future Daiichi examinations are of interest to several organizations within Japan. Since its inception, the U.S. has provided consensus input for high priority time-sequenced examination tasks and supporting research activities. In their Mid-to-Long-term Examination Plan for 1F investigations, TEPCO included all remaining U.S. consensus information requests and additional information requests they identified. TEPCO periodically provides reports on the status of these requests (reflecting D&D priorities, new insights from investigations, and new technologies that become available). Hence, U.S. experts agreed that it was appropriate for TEPCO to track and prioritize these information requests as D&D progresses. U.S. experts will continue to review and comment on the information obtained from examinations and, as needed, provide additional details and relevant background material to support future examinations. As documented in this report, several other items, such as additional details on information requests pertaining to ex-vessel examinations, relevant references from prior research, additional documents to provide insights regarding recent investigation findings, and reviews of recently released documents, were agreed to during the FY2023 meeting.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced manufacturing and digital twin technology for nuclear energy*

Advanced manufacturing techniques and digital twin technology are rapidly transforming the nuclear industry, offering the potential to enhance productivity, safety, and cost-effectiveness. Customized parts are being produced using additive manufacturing, automation, and robotics, while digital twin technology enables the virtual modeling and optimization of complex systems. These advanced technologies can significantly improve operational efficiency, predict system behavior, and optimize maintenance schedules in the nuclear energy sector, leading to heightened safety and reduced downtime. However, the nuclear industry demands the highest levels of safety and security, as well as intricate manufacturing processes and operations. Thus, challenges such as data management and cybersecurity must be addressed to fully realize the potential of advanced manufacturing techniques and digital twin technology in the nuclear industry. This comprehensive review highlights the critical role of digital twin technology with advanced manufacturing toward nuclear energy to improve performance, minimize downtime, and heighten safety, ultimately contributing to the global energy mix by providing dependable and low-carbon electricity.

36 MATERIALS SCIENCE↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems↗

A Review of Regulations, Codes, and Standards for Hydrogen Fuel Cell Electric Bus Use on Airports

This report reviews regulations, codes, and standards to be considered for FCEB operations on airports governing vehicle safety, hydrogen infrastructure, and airport operations. Overall, the review found the existing regulatory framework largely suitable for FCEB operations on airports, with only minor gaps identified pertaining to heavy-duty vehicle fueling, operation and fire safety on airport aprons, and authorization for emergency power use.

08 HYDROGEN↗

Depowering of Batteries to Reduce Cost of Ownership

(1) Executive Summary: End of life batteries (EOLBs) present a cost and safety liability for their owners and stakeholders. This is due flammability, energy, and power with EOLBs. Current approaches include cumbersome, expensive packaging, specialized shipping, regulated storage, and they are responsible for over half of the cost of recycling. They all expensively and inadequately address symptoms. OnTo has developed and proven a simple way to resolve the problem systemically, through depowering of lithium-ion batteries (and most any battery other than lead). The low-cost process removes flammability, power, and energy in EOLBs through non-toxic chemical processing. The opportunity for commerce of inert scrap is at least $5 billion greater than the commerce in hazardous scrap, all made possible through OnTo’s technology for efficiency and safety. (2) Depowering Improves Safety and Decreases Cost of Battery Ownership: OnTo’s depowering technology will remove half of the cost of EOLB management and recycling. Without this technology, EOLB recycling will always be a liability. EOLB is hazardous due to inherent flammability of electrolyte and lithium. The shipping and commerce of EOLBs is costly and dangerous all along the chain of custody from owner, dealership/shop, shipper, second-life sorter, (shipper again), and finally to the destination facility recycler. OnTo’s depowering service renders inert most any EOLB packs, modules, and cells. The technology uses a brief, non-toxic treatment applicable to most any chemistry. The industry needs a safe, simple, modular, and inexpensive method to render EOLBs as inert scrap. OnTo’s deactivation system is scalable to the needs of any customer along the EOLB chain of custody. (3) Evidence of Successful Depowering: Untreated batteries will catch fire and explode under abuse conditions such as heat or crush. Slide 2 below shows that untreated batteries will blow-up and expel their internal components with heating, after OnTo’s depowering treatment, the same battery is inert with the same heat treatment (Fig. 7 in the slide). Depowering also removes electrolyte reactivity, eliminating the production of HF and other toxins (Fig 6. in the slide) The depowering process is applicable to large, 26 Ah cells. Fig. 5 in the slide shows the removal of all the electrolyte from whole cells. Removal of flammable material from an EOLB contributes to the inert behavior. OnTo developed this technology through a project supported by the US Department of Energy EERE program, with partners including Seattle King County Metro Transit. While OnTo has generated evidence of successful depowering of batteries, in 2020, a follow-on voucher opportunity for third party analysis of depowered cells and materials was approved through CalTestBed. The expertise of the battery and materials research groups at Lawrence Berkeley National Laboratory will characterize these depowered cells to provide better understanding of the materials level changes in depowering. (4) Pilot Plant for Depowering EOLBs: Making the spoke work in hub-and-spoke While other companies are marketing the hub-and-spoke approach for recycling EOLBs, they rely on dangerous, expensive shredding methods with flimsy IP protection. OnTo offers the only patented, proven ability to depower EOLBs from most any chemistry – at half of the capital cost required for shredding, while eliminating the liability, danger, and waste streams inherent with shredding. The proposed commercial pilot facility is (5) OnTo Technology LLC Company: OnTo develops advanced battery recycling innovations that produce manufacturing quality electrode materials from recycled batteries. Their patented Cathode-healing™ and Deactivation/Depowering processes improve safety and reduce the cost of recycling. OnTo’s breakthrough technologies produce advanced materials for manufacturing batteries useful in applications from portable power to electric vehicles. Contact: Steve Sloop OnTo Technology LLC, 63221 Service Road, STE F, Bend, OR 97703, ssloop@onto-technology.com , 541-389-7897

deactivation↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Shield Design for 50 kW Three-Phase Wireless Charging System

In this paper, magnetic field emissions (MFE) from a 50 kW bipolar coil-based three-phase wireless charging system (WCS) is investigated. Then, a shield design is proposed to suppress the MFE below the safety limit identified by the International Commission of Non-Ionized Radiation Protection (ICNIRP) guidelines. Bipolar coil-based three-phase (3φ) WCSs provide extremely high power-density; therefore, the 3φ WCSs are highly promising for high-power fast-wireless-charging of the electric vehicles. For the high-power EV application, it is a critical challenge to design a shield to suppress the MFE below the safety limit. The traditional aluminum shield is found ineffective for the bipolar 3φ-WCS. The proposed shield is designed with high-permeability magnetic material, i.e. ferrite, nanocrystalline material, etc. The proposed shield is simulated in finite element analysis (FEA) and the FEA results show that the proposed magnetic shield effectively suppresses the magnetic field emission below the ICNIRP limit. The generalized design of the proposed shield can be used for even higher power bipolar coil based WCSs.

Mohammad, Mostak↗

Opportunities and Challenges of High-Energy Lithium Metal Batteries for Electric Vehicle Applications

Lithium metal batteries have great advantages over state-of-the-art lithium ion batteries in terms of energy density and cost, which present huge opportunities for long-range and low-cost electric vehicles in the future. However, the automotive industry has critical requirements on specific characteristics of battery cells, including but not limited to cycle life, working temperature range, fast discharge–charge capability, volume change, safety, and so on. In this Focus Review, we discuss both the cell- and system-level requirements and challenges of high-energy-density lithium metal batteries for future electrical vehicle applications and highlight some recent key progress in these aspects. Furthermore, our main objective is to identify key strategies on how to solve these challenges and inspire more research and development effort to accelerate the practical applications of lithium metal batteries.

25 ENERGY STORAGE↗

Surface Modification of Nickel-Rich Cathode Materials by Ionically Conductive Materials at Room Temperature

Nickel-rich cathode materials (LiNi x Mn y Co 1-x-y O 2 , NMC) are promising to push the limits of lithium-ion batteries to higher energy density. This approach is favored in practical applications including electric vehicles and aviation transportation. However, the instability of the NMC at charged state results in safety concerns and poor cycling stability. Surface coating is a practical and effective strategy to address this. Cubic Li7La3Zr2O12 (LLZO) is an ideal coating material regarding the low electron transfer rate and high Li+ conductivity. Thus, a LLZO coating layer can suppress the parasitic reactions in the electrode/electrolyte interface without deteriorating the lithium migration. However, high-temperature calcination seems to inevitably create the chemical couplings between NMC and LLZO, leading to the interdiffusion and degradation of NMC and LLZO crystal structures. This work presents a simple mechanochemical method to effectively coat LLZO on the NMC particle surface. Furthermore, the coated cathode demonstrates superior electrochemical performance compared with the pristine NMC cathode.