Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings

Today's selection of DC microgrid buildings features a diverse set of electrical topologies and turnkey solutions, each with specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops M&V procedures for quantifying and comparing the energy efficiency and power quality in buildings. To calculate full-building efficiency, this work introduces the measurement-informed modeling method, a procedure that develops and refines a building's energy model with metered data. To quantify power quality, this work defines a new voltage quality index that applies to both AC and DC buildings. This article describes the equipment, instrumentation, and operation necessary to calculate the efficiency and power quality. It then demonstrates these methods with a set of field tests. We report these M&V procedures can ultimately be used to compare and improve the efficiency and power quality of various DC topologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical potential measurements in the lower atmosphere

Lower-atmospheric potential measurements obtained in 1983 through 1985 using the Hy-wire technique are summarized in this paper. Observed values of the potential were in the range of 50-100 kV in Fairbanks, AK, compared with 100-200 kV at Wallops Island, VA. When one-hour averages are formed from the entire data set the result is a unitary variation very reminiscent of both the Carnegie curve and more recent stratospheric electric field data. A comparison with an aircraft potential measurement in the same vicinity during April 1983 demonstrates that the two techniques yield roughly similar results, except that the Hy-wire measurements were 20-30 percent lower in absolute value.

Woosley, J. D.↗

Electric field measurements across the Harang discontinuity

The Harang discontinuity, the area separating the positive and negative bay regions in the midnight sector of the auroral zone, is a focal point for changes in behavior of many phenomena. Through this region the electric field, in a frame corotating with the earth, rotates through the west from a basically northward field in the positive bay region to a basically southward field in the negative bay region, appearing as a reversal in a single-axis measurement of the north-south component. Thirty-two of these reversals have been identified in the Ogo 6 data from November and December 1969. The discontinuity is dynamic in nature, moving southward and steepening its latitudinal profile as magnetic activity is increased. As activity decreases, it relaxes poleward and spreads out in latitudinal width. It occurs over several hours of magnetic local time.

Maynard, N. C.↗

All-optical single-shot complete electric field measurement of extreme ultraviolet free electron laser pulses

Recent advances in ultrafast extreme ultraviolet (EUV) and x-ray light sources provide direct access to fundamental time and length scales for biology, chemistry, and materials physics. However, such light pulses are challenging to measure due to the need for femtosecond time resolution at difficult-to-detect wavelengths. Also, single-shot measurements are needed because severe pulse-to-pulse fluctuations are common. Here we demonstrate single-shot, complete field measurements by applying a novel version of frequency resolved optical gating. An EUV free electron laser beam creates a transient grating containing the pulse’s electric field information, which is read out with a 400 nm probe pulse. By varying the time delay between two copies of the EUV pump, rather than between the pump and the probe, we separate the needed coherent wave mixing from the slow incoherent response. Because this approach uses photoionization, it should be applicable from the vacuum ultraviolet to hard x rays.

36 MATERIALS SCIENCE↗

Phase identification using statistical analysis

A device includes at least one processor configured to determine, based on (i) a first plurality of time-varying electrical measurements corresponding to a feeder head of a power distribution network having a plurality of phases and (ii) a second plurality of time-varying electrical measurements corresponding to a node in the power distribution network, and using statistical analysis, a predicted phase, from the plurality of phases, that corresponds to the node. The processor may be configured to use ranked correlation coefficients (such as the Kendall rank correlation coefficient) to determine the predicted phase and may use principle component analysis. The processor is also configured to cause at least one device of the power distribution network to modify operation based at least on part on the predicted phase.

Veda, Santosh Sambamoorthy↗

Measuring Fracture Times Of Ceramics

Electrical measurements complement or replace fast cinematography. Electronic system measures microsecond time intervals between impacts of projectiles on ceramic tiles and fracture tiles. Used in research on ceramics and ceramic-based composite materials such as armor. Hardness and low density of ceramics enable them to disintegrate projectiles more efficiently than metals. Projectile approaches ceramic tile specimen. Penetrating foil squares of triggering device activate display and recording instruments. As ceramic and resistive film break oscilloscope plots increase in electrical resistance of film.

Shlichta, Paul J.↗

Local electric field measurement in GaN diodes by exciton Franz–Keldysh photocurrent spectroscopy

The eXciton Franz–Keldysh (XFK) effect is observed in GaN p–n junction diodes via the spectral variation of photocurrent responsivity data that redshift and broaden with increasing reverse bias. Photocurrent spectra are quantitatively fit over a broad photon energy range to an XFK model using only a single fit parameter that determines the line shape and the local bias (V l ), uniquely determining the local electric field maximum and depletion widths. As expected, the spectrally determined values of V l vary linearly with the applied bias (V) and reveal a large reduction in the local electric field due to electrostatic non-uniformity. The built-in bias (V bi ) is estimated by extrapolating V l at V=0, which, when compared with independent C-V measurements, indicates an overall ±0.31 V accuracy of V l . This demonstrates sub-bandgap photocurrent spectroscopy as a local probe of electric field in wide bandgap diodes that can be used to map out regions of device breakdown (hot spots) for improving electrostatic design of high-voltage devices.

42 ENGINEERING↗

Hy-wire and fast electric field change measurements near an isolated thunderstorm, appendix C

Electric field measurements near an isolated thunderstorm at 6.4 km distance are presented from both a tethered balloon experiment called Hy-wire and also from ground based fast and slow electric field change systems. Simultaneous measurements were made of the electric fields during several lightning flashes at the beginning of the storm which the data clearly indicate were cloud-to-ground flashes. In addition to providing a comparison between the Hy-wire technique for measuring electric fields and more traditional methods, these data are interesting because the lightning flashes occurred prior to changes in the dc electric field, although Hy-wire measured changes in the dc field of up to 750 V/m in the direction opposite to the fair weather field a short time later. Also, the dc electric field was observed to decay back to its preflash value after each flash. The data suggest that Hy-wire was at the field reversal distance from this storm and suggest the charge realignment was taking place in the cloud with a time constant on the order of 20 seconds.

Holzworth, R. H.↗

Apparatus, methods and system for temperature gradient aging with in-situ electrical monitoring

An apparatus for making in-situ electrical measurements of a sample while the sample is subjected to a temperature gradient between a first side of the sample and a second side of the sample. The apparatus comprises a first heater and a second heater that are positioned in contact with the first side of the sample and the second side of the sample, respectively. The first heater and the second heater comprise respective faces that each have electrical contacts embedded therein. Electrical measurements pertaining to the sample can be made by way of the electrical contacts embedded in the faces. A temperature at either side of the sample can be monitored by way of thermocouples positioned inside the heaters in proximity to the faces of the heaters.

Reyes, Karla Rosa↗

Engineering Area Investigation of Reliability Attributes and Accelerated Stress Factors on Terrestrial Solar Cells

Results obtained include the definition of a simplified stress test schedule for terrestrial solar cells based on the work performed during the first program year, and the design and fabrication of improved jigs and fixtures for electrical measurement and stress testing. Implementation of these advanced techniques for accelerated stress testing is underway on three solar cell types. In addition, review of the literature on second quadrant phenomena was begun and some preliminary second-quadrant electrical measurements were performed. Results obtained at the first down time for 75 C B-T testing and biased and unbiased T-H pressure cooker testing of type F cells showed little or no degradation in electrical parameters. Significant physical effects (large solder bubbles) were noted for type F cells subjected to the pressure cooker stress test.

Lathrop, J. W.↗

Lightning electric field measurements which correlate with strikes to the NASA F-106B aircraft, 22 July 1980

Ground-based data collected on lightning monitoring equipment operated by Goddard Space Flight Center at Wallops Island, Virginia, during a storm being monitored by NASA's F-106B, are presented. The slow electric field change data and RF radiation data were collected at the times the lightning monitoring equipment on the aircraft was triggered. The timing of the ground-based events correlate well with events recorded on the aircraft and provide an indication of the type of flash with which the aircraft was involved.

Levine, D. M.↗

Electrical impedance measurements in the arm and the leg during a thirty day bed rest study

The need to detect, follow, and understand the effects of gravity on body fluid distribution is a constant stimulus to the quest for new techniques in this area of research. One of these techniques is electrical bioimpedance spectroscopy (BIS). Although not new, this is a technique whose applications to biomedical research are fairly recent. What is new is the development of instrumentation that has made practical the use of impedance spectroscopy in the biomedical setting, particularly in studies involving human subjects. The purpose of this paper is to report impedance spectroscopy observations made on a subject who was submitted to bed rest for a period of thirty days. These observations were made as part of a study on muscle atrophy during a thirty day head down bed rest. Since bed rest studies are very costly in human and financial terms, and technically difficult to realize, we felt that even though the present study deals only with a single case it was worthy of reporting because it illustrates kinds of questions impedance spectroscopy may help to answer in microgravity research.

Cardus, David↗

Plasma-assisted deposition and characterization of Al 2 O 3 dielectric layers on (001) β -Ga 2 O 3

In this work, we have investigated plasma-assisted deposition of Al 2 O 3 on HVPE (001) β-Ga 2 O 3 and evaluated the dielectric quality from electrical measurements on fabricated metal-oxide-semiconductor (MOS) capacitors. The interface structure and crystallinity of the films were investigated as a function of the growth temperature. The dielectric/semiconductor interfaces were found to have reverse breakdown electric fields up to 5.3 MV/cm in the β-Ga 2 O 3 , with relatively low hysteresis in capacitance–voltage and low leakage current. We determined a negative fixed interface charge density at the interface from analysis of thickness-dependent capacitance voltage data. In conclusion, this study shows the advantage of using plasma-assisted deposition to achieve high breakdown strength Al 2 O 3 /β-Ga 2 O 3 MOS structures for device application purposes.

42 ENGINEERING↗

Monitoring accelerated alkali-silica reaction in concrete prisms with petrography and electrical conductivity measurements

We report deterioration of concrete due to alkali-silica reaction (ASR) involves a reaction between alkaline ions in the cement pore solution and non-crystalline silica found in many aggregates. Diagnosing and quantifying deterioration due to ASR in concrete currently requires destructive testing for microscopy examinations. In this paper, electrical conductivity is investigated qualitatively as an alternative non-destructive evaluation (NDE) method of ASR in hardened concrete. The study was performed using an unrestrained set of small concrete prism specimens made with highly reactive small aggregates, and kept in an environmental chamber according to ASTM C1293 standard. In a companion study, destructive petrography and damage rating index (DRI) assessment, and pore solution extraction and analysis were performed on the same set of accelerated ASR specimens. The results show that temporal evolution of nondestructive bulk resistivity is linearly correlated with destructive DRI score.

36 MATERIALS SCIENCE↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric field measurements in the solar wind, bow shock, magnetosheath, magnetopause, and magnetosphere

Electro-field measurements are reported at 11 magnetopause crossings that occurred during a single in-bound ISEE-1 satellite pass near a local time of 10:30. In combination with magnetic-field data, these measurements show the existence of electro-field components tangential to the actual magnetopause in the frame of rest of the magnetopause on every crossing of the current-carrying layers associated with the 11 magnetopause traversals. These tangential electric-field components were oriented with respect to the magnetopause sheet currents, such that there was an electrical power dissipation of between 30 and 110 W/sq km on 10 of the 11 crossings. These results are in agreement with requirements of reconnection theories. Histograms of the normal electric-field components and of the orientation, velocity, and thickness of the current-carrying layer are presented. The existence of a parallel electric field in the magnetosheath near the magnetopause and of propagation of large-amplitude waves along the magnetopause is suggested.

Mozer, F. S.↗

Electrical Charging Hazards Originating from the Surface (ECHOS): Understanding the Martian Electro-Meteorological Environment

In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.

Farrell, W. M.↗

Measuring the Electrical Properties of Epoxies

Two techniques rapidly determine low-frequency resistivity of conductive epoxies and high-frequency dielectric properties of insulating epoxies. Conductive epoxy is molded in channels in plastic block. Four-point ohmmeter is used to apply current and sense voltage; it reads out resistance. Because mold has precise and stable dimensions, it produces accurate consistent measurements.

Sergent, J. E.↗