Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models of individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.

Bhattacharya, Saptarshi↗

Road Lidar Dataset for the TxDOT Austin District

This is a road lidar data collection for developing road elevation models and road inundation mapping methodologies, a joint work between ORNL and The University of Texas at Austin. This dataset is generated as part of the flood transportation infrastructure, partly funded by the NOAA CIROH project. ORNL is a project partner for high-performance computing-empowered flood inundation mapping methodology R&D. The dataset is computed using a GPU-accelerated lidar data processing workflow developed at ORNL. The lidar data source is from TxGIO, the state lidar data collection site. The output dataset is in two formats: laz and copc. It is organized by TxDOT's maintenance sections, covering the Austin District. Data size: 3.86 billion road lidar points, 1.67% of the entire lidar data input Projection: EPSG:32614 (WGS84/UTM zone 14N) Website: https://web.corral.tacc.utexas.edu/nfiedata/road3d/austin_district/AustinMaintenanceSections_H_epsg6343_V_epsg5703/ LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

15 GEOTHERMAL ENERGY↗

Financing Energy Upgrades for K-12 School Districts: A Guide to Tapping into Funding for Energy Efficiency and Renewable Energy Improvements

This guide focuses on clean energy financing options for school administrators, facility managers, and other K-12 school decision makers who are considering investments in high performance school projects. This guide explicitly focuses on comprehensive energy upgrades, those that involve multiple measures and are targeted toward achieving significant energy savings. Successful implementation of clean energy upgrades in schools is a matter of understanding the opportunity, making the commitment, and creatively tapping into available financing. This guide attempts to provide the foundation needed for successful projects in U.S. schools. It walks through the financing options available to K-12 schools and provides case studies of six school districts from around the country.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Elko County School District (ECSD) Geothermal Evaluation: Basin College Direct Use Geothermal Demonstration Project

The system has been in continuous operation since October 1986 and serves various customers with approximately 180°F geothermal heating water for use at each facility as shown in Exhibit B. The system which is maintained by the school district consists of two main water loops. The system was designed for a large temperature difference instead of the normal 20°ΔT heating system. Using the design 80°ΔT, we yield 4+ times more energy with the same water flow. Loop 1 is the main geothermal water loop which flows from the production well through two main system heat exchangers and, after heat is extracted, to the disposal area. Loop 2, the customer heating loop, is heated in the main heat exchangers and then runs through approximately 5500 feet of buried supply piping and approximately 5500 feet of buried return piping to each customer facility where a facility heat exchanger is provided for each customers use. All piping on the customers’ side of each facility heat exchanger is the responsibility of the individual customer. Although originally designed to work with an 80ºΔT, this has deteriorated over the years and cannot achieve this at the present time. The system has operated over the last 29 years with minimal maintenance but is now starting to show its age with various corrosion issues, control problems, and several leaks. Some parts of the system are also located in areas where proposed building expansions will require piping relocations.This is the final technical report for the Great Basin College Direct Use Geothermal Demonstrationn Project, outlining the technical aspects of the User Group System.

15 GEOTHERMAL ENERGY↗

Cost Effectiveness of ASHRAE Standard 90.1-2013 for the District of Columbia

Moving to the ASHRAE Standard 90.1-2013 (ASHRAE 2013) edition from Standard 90.1-2010 (ASHRAE 2010) is cost-effective for the District of Columbia. The table below shows the state-wide economic impact of upgrading to Standard 90.1-2013 in terms of the annual energy cost savings in dollars per square foot, additional construction cost per square foot required by the upgrade, and life-cycle cost (LCC) per square foot. These results are weighted averages for all building types in all climate zones in the state, based on weightings shown in Table 4. The methodology used for this analysis is consistent with the methodology used in the national cost-effectiveness analysis. Additional results and details on the methodology are presented in the following sections. The report provides analysis of two LCC scenarios: Scenario 1, representing publicly-owned buildings, considers initial costs, energy costs, maintenance costs, and replacement costs—without borrowing or taxes. Scenario 2, representing privately-owned buildings, adds borrowing costs and tax impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a project on North Unit Irrigation District’s Main Canal at the Monroe Drop, using a novel low-head hydropower technology called the SLH100

Natel Energy is a low­-head, distributed hydropower company based out of Alameda, CA. Natel manufactures and sells proprietary hydroelectric turbines called hydroEngines® that are suitable for low-­head, high-­flow settings, and range from 30kW to 1 MW of capacity per unit. Natel’s hydroEngine is a state­-of­the-­art two stage impulse turbine, using blades mounted symmetrically on two belts perpendicular to the axis of travel, and using linearly­-moving foils, rather than a rotor, to enable efficient conversion of kinetic energy of large volumes of water at low head with no risk of cavitation. In addition, the hydroEngine can be installed at or above tailwater level, reducing the excavation necessary to build the powerhouse and thus reducing total installed cost and project footprint. Thus, the hydroEngine technology enables a new generation of small hydro installations with low cost of project development, fish-­friendly operations, and small project footprint. In September of 2015, Natel Energy formally commissioned its first project installation in Madras, Oregon, installing 1 SLH100 turbine at an existing drop structure on the North Unit Irrigation District (NUID) Main Canal. The water falls between 13.5 feet to 16.5 feet at this structure, depending on flow. The plant has an installed capacity of 250 kW and an expected annual generation of approximately 873 MWh. The plant operates at an annual capacity factor of 40%, and a capacity factor over the irrigation season, or period of available flow, of 80%. Annual capacity factor is calculated as a percentage of plant operating hours relative to a total of 8,760 hours in a year; because the irrigation canal in which the Project is located only runs water from April to October, the available flow capacity factor is higher. Net greenhouse gas reductions from the Monroe Project are estimated to be 602 tCO2/year. The purpose of this report is to provide an overview of the specifications for Natel’s first commissioned project, the project development process, the plant’s performance, project costs, and the construction, installation, and commissioning process. We hope that this report will provide useful context for assessment of the hydroEngine as a viable technology choice for future distributed, low-­head hydropower projects, as well as assessment of the bankability, performance, reliability, and cost of the hydroEngine.

13 HYDRO ENERGY↗

GATEWAY Report: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

The GATEWAY program evaluated a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency, Water Efficiency, and Renewable Energy Site Assessment: San Juan National Forest - Dolores Ranger District, Colorado

This report summarizes the results from an energy efficiency, water efficiency, and renewable energy site assessment of the Dolores Ranger District in the San Juan National Forest in Colorado. A team led by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the assessment with United States Forest Service (USFS) personnel on August 16-17, 2016, as part of ongoing efforts by USFS to reduce energy and water use and implement renewable energy technologies. The assessment is approximately an American Society of Heating, Refrigerating, and Air-Conditioning Engineers Level 2 audit and meets Energy Independence and Security Act requirements.

54 ENVIRONMENTAL SCIENCES↗

Manhattan District: A Lab-Embedded Entrepreneur Program

The goals of the Manhattan District are to attract top scientific innovators to New Mexico to start businesses that focus on breakthrough national security technologies, support them with access to scientific leaders, partner networks, and funding to ensure success, build economic prosperity locally and nationally, leverage national networks with UC, TAMU, Battelle and strategic partners in industry and venture capital, and build on proven models from other DOE National Labs to enhance NNSA missions.

36 MATERIALS SCIENCE↗

Peña Station NEXT Energy District Master Plan (Cooperative Research and Development Final Report, CRADA Number CRD-17-681)

The objective of the project is to work in close collaboration with Panasonic, Xcel Energy (Public Service), and their partners L.C. Fulenwider, and Denver International Airport to examine different design and technology options in creating an energy master plan for the 400 acre Pena Station NEXT district in Denver, Colorado. To accomplish this, NREL will conduct a solar power/battery storage/grid integration study using the OpenDSS platform linked to UrbanOPT software.

25 ENERGY STORAGE↗

Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for the District of Columbia

These analyses evaluate the cost-effectiveness of the prescriptive path of the 2015 edition of the International Energy Conservation Code (IECC), relative to the 2012 and 2009 IECC for all 50 states and the District of Columbia. The analysis covers one- and two-family dwelling units, townhomes, and low-rise multifamily residential buildings covered by the residential provisions of the 2015 IECC. These reports were originally published in October 2015, and revised in February 2016 to update numbers reported in certain results tables.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INL CRMO XRF Report 2025-03: Provenance Determinations for 854 Projectile Points from Idaho Falls District Bureau of Land Management Archaeological Collections

This report presents provenance determinations for 854 obsidian and fine-grained volcanic projectile points from Idaho Falls District Bureau of Land Management collections. Provenance determinations were made using energy dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

99 - GENERAL AND MISCELLANEOUS↗