Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Beam Dynamics Challenges in the Muon g-2 Experiment

The muon&s;s anomalous magnetic moment $a_{\mu}$ has hinted at physics beyond the standard model for nearly 20 years. The Muon $g-2$ experiment at Fermilab aims to measure $a_{\mu}$ to 140 parts per billion (ppb) precision. The 460 ppb result from its first data run (Run-1), released in 2021, agreed with the previous 2006 Brookhaven Muon $g-2$ result. The experimental average stands in tension with the standard model theory $a_{\mu}$ prediction by $4.2 \sigma$. The result of Run-2/3 data analysis is set be released in summer 2023, and will improve on the Run-1 precision by a factor of two. With the data collected in all six runs, the experiment is on track to produce a 140 ppb measurement of $a_{\mu}$. If the experiment and theory central values are both unchanged, the tension would exceed $5 \sigma$. The measurement is accomplished by injecting muons into a magnetic storage ring and precisely measuring two observable frequencies: $\omega_a$, the muons&s; anomalous precession frequency, and $\tilde{\omega}&s;_p$, the precession frequency of protons which determines the magnetic field strength experienced by the muons. This thesis presents a selection of muon beam dynamics effects which are critical for reaching the experiment precision goal. A system of detectors assists with the challenging beam injection into the storage ring, and a measurement of the injected beam provides input for simulating the stored beam dynamics. A new method is introduced to reduce a critical systemic caused by time dependence in the stored beam momentum, enabled by a detector which directly profiles the stored beam. Finally the analysis of $\tilde{\omega}&s;_p$, the muon-weighted magnetic field, for the Run-2/3 result is presented. Systematics of $\tilde{\omega}&s;_p$ due to beam effects are evaluated in detail, and shown to be sub-dominant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suprathermal ion detector experiment (lunar ionosphere detector)

The highly directional flow of energetic ions down the magnetosheath is described using three different look directions of the three Apollo 15 SIDE instruments. The effects of the interaction of the LM ascent-engine exhaust with the magnetosheath ions observed at the Apollo 15 site are discussed, and a preliminary analysis of the SIDE data for Apollo 12 and 14 is included.

Hills, H. K.↗

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters), but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/f noise as compared to sum extraction. We evaluate the noise introduced by pre-amplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/ f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters) but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/ f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/ f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/ f noise as compared to sum extraction. We evaluate the noise introduced by preamplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

Exoplanet atmospheres↗

Progress on the design of the interaction region of the Electron-Ion Collider EIC

We present an update on the design of the Interaction Region (IR) for the the Electron Ion Collider (EIC) being built at Brookhaven National Laboratory (BNL). The EIC will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV with luminosities of up to 10^34 /cm^2/s. The IR, located at RHIC's IR6, is designed to meet the requirements of the nuclear physics community as outlined in [1]. A second IR is technically feasible but not part of the project.The magnet apertures are sufficiently large to allow desired collision products to reach the far-forward detectors; the electron magnet apertures in the rear direction are chosen to be large enough to pass the synchrotron radiation fan. In the forward direction the electron apertures are large enough for non-Gaussian tails.The paper discusses a number of recent recent changes to the design. The machine free region was recently increased from 9 to 9.5 m to allow for more space in the forward direction for the detector. The superconducting magnets on the forward side now operate at 1.9 K, which helps crosstalk and space issues.

43 PARTICLE ACCELERATORS↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory characterization of direct readout Si:Sb and Si:Ga infrared detector arrays

Highlights of recent results obtained at Ames Research Center in performance evaluations of infrared detector arrays are presented. Antimony- and gallium-doped silicon direct readout 58x62 element hybrid devices from Ames' ongoing detector technology development program are described. The observed characteristics meet most of the performance goals specified by the Space Infrared Telescope Facility (SIRTF) instrument teams and compare favorably with the best performance reported for discrete non-integrating extrinsic silicon detectors. Initial results of radiation environment testing are reported, and non-ideal behavior demonstrated by these test devices is discussed.

Mckelvey, Mark E.↗

First experimental study of multiple orientation muon tomography, with image optimization in sparse data environments

Due to the high penetrating power of cosmic ray muons, they can be used to probe very thick and dense objects. As charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object, particle direction changes can be used to extract scattering information within an object. This can be used to produce a scattering intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies have been published with multi-orientation tomography, which can form a three-dimensional representation faster than a single orientation view. In this work we present the first experimental multiple orientation muon tomography study. Experimental muon-scatter based tomography was performed using a concrete filled steel drum with several different metal wedges inside, between detector planes. Data was collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were then combined using two different tomographic methods. Results showed that using a combination of multiple depth-of-field reconstructions, rather than a traditional inverse Radon transform approach used for CT, resulted in more useful images for sparser data. As cosmic ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedge compositions.

Applied Physics (physics.app-ph)↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

Measurements of heavy solar wind and higher energy solar particles during the Apollo 17 mission

The lunar surface cosmic ray experiment, consisting of sets of mica, glass, plastic, and metal foil detectors, was successfully deployed on the Apollo 17 mission. One set of detectors was exposed directly to sunlight and another set was placed in shade. Preliminary scanning of the mica detectors shows the expected registration of heavy solar wind ions in the sample exposed directly to the sun. The initial results indicate a depletion of very-heavy solar wind ions. The effect is probably not real but is caused by scanning inefficiencies. Despite the lack of any pronounced solar activity, energetic heavy particles with energies extending to 1 MeV/nucleon were observed. Equal track densities of approximately 6000 tracks/cm sq 0.5 microns in length were measured in mica samples exposed in both sunlight and shade.

Walker, R. M.↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Promising Technologies and R&D Directions for the Future Muon Collider Detectors

Among the post-LHC generation of particle accelerators, the muon collider represents a unique machine with capability to provide very high energy leptonic collisions and to open the path to a vast and mostly unexplored physics programme. However, on the experimental side, such great physics potential is accompanied by unprecedented technological challenges, due to the fact that muons are unstable particles. Their decay products interact with the machine elements and produce an intense flux of background particles that eventually reach the detector and may degrade its performance. In this paper, we present technologies that have a potential to match the challenging specifications of a muon collider detector and outline a path forward for the future R&D efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directional detection of dark matter using solid-state quantum sensing

Next-generation dark matter (DM) detectors searching for weakly interacting massive particles (WIMPs) will be sensitive to coherent scattering from solar neutrinos, demanding an efficient background-signal discrimination tool. Directional detectors improve sensitivity to WIMP DM despite the irreducible neutrino background. Wide-bandgap semiconductors offer a path to directional detection in a high-density target material. A detector of this type operates in a hybrid mode. Here, the WIMP or neutrino-induced nuclear recoil is detected using real-time charge, phonon, or photon collection. The directional signal, however, is imprinted as a durable sub-micron damage track in the lattice structure. This directional signal can be read out by a variety of atomic physics techniques, from point defect quantum sensing to x-ray microscopy. In this Review, we present the detector principle as well as the status of the experimental techniques required for directional readout of nuclear recoil tracks. Specifically, we focus on diamond as a target material; it is both a leading platform for emerging quantum technologies and a promising component of next-generation semiconductor electronics. Based on the development and demonstration of directional readout in diamond over the next decade, a future WIMP detector will leverage or motivate advances in multiple disciplines toward precision dark matter and neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimating List-Mode Data Sensitivities to Nuclear Data with MCNP6

Nuclear data are a vital component of predictive simulations used in applications like experiment design, stockpile stewardship, nuclear nonproliferation/safeguards, health physics, and criticality safety. A singular simulation requires the coalescence of different areas of nuclear data such as cross sections, angular distributions, and energy distributions of emitted neutrons for different materials and energy ranges. Improving nuclear data and thus reducing the uncertainty in simulated parameters could enable smaller, better-informed safety factors and ultimately reduce operational and procedural costs. There is a constant effort to garner a better understanding of the physical quantities represented by nuclear data through experiments. Integral experiment benchmarks use simulated and measured results to validate current nuclear data values. In the past, benchmarks primarily focused on the effective multiplication factor (k eff ); however, this limited scope has caused compensating errors and areas of nuclear data that lack validation. Compensating errors are inaccuracies in nuclear data that are obfuscated by cancellation when observing integrated values such as k eff . Diverse integral benchmark experiments that look for quantities of interest other than k eff and include multiple responses minimize the possibility of compensating errors and provides validation to areas of nuclear data previously lacking experimental validation. Benchmark experiments can be optimized during the design process to be highly dependent on specific areas of nuclear data. The dependence of a response in an experiment to a specific area/type of nuclear data is defined as sensitivity. A larger sensitivity means that nuclear data uncertainties will play a larger role in the response(s) resulting in larger bias. Currently, the sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®1 ) transport code are limited to responses of k eff and tallied values (e.g., flux, surface current). As a part of the EUCLID project, this work explores estimating list-mode nuclear data sensitivities that can be used to design experiments aimed to constrain and reduce compensating errors in nuclear data by focusing on responses other than k eff . Tallied values are ideal quantities that are estimated with detectors during experiments. List-mode data (a list of neutron collection times) are the direct output of detector systems in subcritical neutron noise experiments. Expanding MCNP sensitivity capabilities to include the sensitivity of responses estimated from list-mode data, such as the prompt neutron decay constant (α) and multiplicity estimates (S and D), enables more direct comparison of simulated and measured experimental quantities. Additionally, deterministic tools such as SENSMG are capable of obtaining sensitivities to a wide variety of responses; however, these tools cannot handle complex geometries due to the assumptions made in discretizing the phase-space variables of the Boltzman transport equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved sensitivity of the DRIFT-IId directional dark matter experiment using machine learning

We demonstrate a new type of analysis for the DRIFT-IId directional dark matter detector using a machine learning algorithm called a Random Forest Classifier. The analysis labels events as signal or background based on a series of selection parameters, rather than solely applying hard cuts. The analysis efficiency is shown to be comparable to our previous result at high energy but with increased efficiency at lower energies. This leads to a projected sensitivity enhancement of one order of magnitude below a WIMP mass of 15 GeV c -2 and a projected sensitivity limit that reaches down to a WIMP mass of 9 GeV c -2 , which is a first for a directionally sensitive dark matter detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗