Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dead time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Gamma-ray Exportable Adjustable Spectrum Evolution

An initial number of fissions on a fissile/fissionable material, defined by ENDF library availability, is used to produce an initial inventory of fission products (FPs). The FPs are decayed using full, analytical solutions to the Bateman equations to calculate the FP inventory at a user-specified time. The radiation detector, a high-purity germanium (HPGe) detector, has been modeled using every gamma-ray in the ENDF/TENDL libraries individually, and the modeled response can be multiplied by the activity of each fission product to determine a full, energy dependent detector response, including dead time. The detector response can be output as a PeakEasy (.spe) file, or as a text file. Since each radioisotope's inventory is known, the proportion to the total may be shown for each isotope, as well as many radionuclides in a user-specified energy window. Full execution and display of results takes 1-3 seconds, depending on the complexity of the input parameters.

Holschuh, ThomasV [Idaho National Laboratory (INL)↗

Array-scale performance of TES X-ray Calorimeters Suitable for Constellation-X

Having developed a transition-edge-sensor (TES) calorimeter design that enables high spectral resolution in high fill-factor arrays, we now present array-scale results from 32-pixel arrays of identical closely packed TES pixels. Each pixel in such an array contains a Mo/Au bilayer with a transition temperature of 0.1 K and an electroplated Au or Au/Bi xray absorber. The pixels in an array have highly uniform physical characteristics and performance. The arrays are easy to operate due to the range of bias voltages and heatsink temperatures over which solution better than 3 eV at 6 keV can be obtained. Resolution better than 3 eV has also been obtained with 2x8 time-division SQUID multiplexing. We will present the detector characteristics and show spectra acquired through the read-out chain from the multiplexer electronics through the demultiplexer software to real-time signal processing. We are working towards demonstrating this performance over the range of count rates expected in the observing program of the Constellation-X observatory. We mill discuss the impact of increased counting rate on spectral resolution, including the effects of crosstalk and optimal-filtering dead time.

Kilbourne, C. A.↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

COMPTEL solar flare observations

COMPTEL as part of a solar target of opportunity campaign observed the sun during the period of high solar activity from 7-15 Jun. 1991. Major flares were observed on 9 and 11 Jun. Although both flares were large GOES events (greater than or = X10), they were not extraordinary in terms of gamma-ray emission. Only the decay phase of the 15 Jun. flare was observed by COMPTEL. We report the preliminary analysis of data from these flares, including the first spectroscopic measurement of solar flare neutrons. The deuterium formation line at 2.223 MeV was present in both events and for at least the 9 Jun. event, was comparable to the flux in the nuclear line region of 4-8 MeV, consistent with Solar-Maximum Mission (SSM) Observations. A clear neutron signal was present in the flare of 9 Jun. with the spectrum extending up to 80 MeV and consistent in time with the emission of gamma-rays, confirming the utility of COMPTEL in measuring the solar neutron flux at low energies. The neutron flux below 100 MeV appears to be lower than that of the 3 Jun. 1982 flare by more than an order of magnitude. The neutron signal of the 11 Jun. event is under study. Severe dead time effects resulting from the intense thermal x-rays require significant corrections to the measured flux which increase the magnitude of the associated systematic uncertainties.

Ryan, J. M.↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal Formation and Growth Kinetics of Polyelectrolyte Complex Micelles with Millisecond Resolution

We have directly observed the in situ self-assembly kinetics of polyelectrolyte complex (PEC) micelles by synchrotron time-resolved small-angle X-ray scattering, equipped with a stopped-flow device that provides millisecond temporal resolution. A synthesized neutral-charged diblock polycation and homopolyanion that we have previously investigated as a model charge-matched, core-shell micelle system were selected for this work. The initial micellization of the oppositely charged polyelectrolytes was completed within the dead time of mixing of 100 ms, followed by micelle growth and equilibration up to several seconds. By combining the structural evolution of the radius of gyration (R-g) with complementary molecular dynamics simulations, we show how the self-assemblies evolve incrementally in size over time through a two-step kinetic process: first, oppositely charged polyelectrolyte chains pair to form nascent aggregates that immediately assemble into spherical micelles, and second, these PEC micelles grow into larger micellar entities. Furthermore, this work has determined one possible kinetic pathway for the initial formation of PEC micelles, which provides useful physical insights for increasing fundamental understanding self-assembly dynamics, driven by polyelectrolyte complexation that occurs on ultrafast time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Frequency response of linear systems from transient data

Methods are presented that use general correlative time-response input and output data for a linear system to determine the frequency-response function of that system. These methods give an exact description of any linear system for which such transient data are available. Examples are shown of application of a method to both an underdamped and a critically damped exact second-order system, and to an exact first-order system with and without dead time. Experimental data for a turbine-propeller engine showing the response of engine speed to change in propeller-blade angle are presented and analyzed.

Laverne, Melvin E↗

Hybridizing matter-wave and classical accelerometers

We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely, the dead times between consecutive measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maia Mapper: high definition XRF imaging in the lab

Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

47 OTHER INSTRUMENTATION↗

IceSat 2 ATLAS Photon-Counting Receiver - Initial On-Orbit Performance

Photon-counting receivers are deployed on the NASA Ice, Cloud and land Elevation Satellite-2 (ICESat2) Advance Topographic Laser Altimeter System (ATLAS). The ATLAS laser altimeter design has total six ground tracks with three strong and three weak tracks. The strong track has nominally 4 times more laser power than the weak track. The receiver is operated in photon counting mode. There are 16 photon-counting channels for each strong track and 4 photon-counting channels for each weak track. Hamamatsu photomultiplier with a 4x4-array anode was used as photon counting detector. This receiver design has high counting efficiency (>15%) at 532 nm, low dark count rate (<400 counts per second), low jitter (less than 285ps), short dead time (<3 ns), long lifetime under large solar background radiation, radiation harden for space operation, and ruggedized for survives the harsh vibration during the launch. In this paper, we will present the initial on-orbit performance of this photon-counting receiver.

Yang, Guangning↗

Design, construction, and test of the Gas Pixel Detectors for the IXPE mission

Due to be launched in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2–8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis—particularly as far as the response to unpolarized radiation and the stability in time are concerned.

79 ASTRONOMY AND ASTROPHYSICS↗

Focus: Two-dimensional electron-electron double resonance and molecular motions: The challenge of higher frequencies

The development, applications, and current challenges of the pulsed ESR technique of two-dimensional Electron-Electron Double Resonance (2D ELDOR) are described. This is a three-pulse technique akin to 2D Exchange Nuclear Magnetic Resonance, but involving electron spins, usually in the form of spin-probes or spin-labels. As a result, it required the extension to much higher frequencies, i.e., microwaves, and much faster time scales, with π/2 pulses in the 2-3 ns range. It has proven very useful for studying molecular dynamics in complex fluids, and spectral results can be explained by fitting theoretical models (also described) that provide a detailed analysis of the molecular dynamics and structure. We discuss concepts that also appear in other forms of 2D spectroscopy but emphasize the unique advantages and difficulties that are intrinsic to ESR. Advantages include the ability to tune the resonance frequency, in order to probe different motional ranges, while challenges include the high ratio of the detection dead time vs. the relaxation times. We review several important 2D ELDOR studies of molecular dynamics. (1) The results from a spin probe dissolved in a liquid crystal are followed throughout the isotropic → nematic → liquid-like smectic → solid-like smectic → crystalline phases as the temperature is reduced and are interpreted in terms of the slowly relaxing local structure model. Here, the labeled molecule is undergoing overall motion in the macroscopically aligned sample, as well as responding to local site fluctuations. (2) Several examples involving model phospholipid membranes are provided, including the dynamic structural characterization of the boundary lipid that coats a transmembrane peptide dimer. Additionally, subtle differences can be elicited for the phospholipid membrane phases: liquid disordered, liquid ordered, and gel, and the subtle effects upon the membrane, of antigen cross-linking of receptors on the surface of plasma membrane, vesicles can be observed. These 2D ELDOR experiments are performed as a function of mixing time, T{sub m}, i.e., the time between the second and third π/2 pulses, which provides a third dimension. In fact, a fourth dimension may be added by varying the ESR frequency/magnetic field combination. Therefore, (3) it is shown how continuous-wave multifrequency ESR studies enable the decomposition of complex dynamics of, e.g., proteins by virtue of their respective time scales. These studies motivate our current efforts that are directed to extend 2D ELDOR to higher frequencies, 95 GHz in particular (from 9 and 17 GHz), in order to enable multi-frequency 2D ELDOR. This required the development of quasi-optical methods for performing the mm-wave experiments, which are summarized. We demonstrate state-of-the-art 95 GHz 2D ELDOR spectroscopy through its ability to resolve the two signals from a spin probe dissolved in both the lipid phase and the coexisting aqueous phase. As current 95 GHz experiments are restricted by limited spectral coverage of the π/2 pulse, as well as the very short T{sub 2} relaxation times of the electron spins, we discuss how these limitations are being addressed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Cascaded Ring Oscillator Vernier based TDC Architecture with a Feedthrough Reference Oscillator

Time to digital converters (TDCs) are widely used in particle physics and medical imaging to determine the relative arrival time of photons and other particles. Vernier TDCs are one of the most attractive options due to their power consumption efficiency and their small footprint. We present our newly patented innovative architecture of cascaded-stage Vernier TDCs comprised of a feedthrough reference oscillator. This architecture lead to successive Vernier measurements that result in a lower number of cycles for the same dynamic range to resolution ratio (DRRR), leading to reduced conversion time and lower jitter. To validate this architecture, a test chip was designed in 0.18~μm TSMC technology, integrating four types of cascaded Vernier TDCs with an increasing number of stages. The performance of the chip was assessed using a modular test platform specifically designed for TDCs. For comparison purposes, all TDCs were tested with a LSB of 50~ps and a dynamic range of 20~ns. The experimental results demonstrate the highest gain in performance between 1 stage Vernier and 2 stage Vernier TDCs with the precision improved from 36~ps~rms to 21~ps~rms, the maximum number of turns from 110 to 25 counts and the dead time, from 266.4~ns to 76.5~ns, on average. Adding Vernier stages is only relevant for a higher DRRR. Therefore, the 3-stage and 4-stage Vernier TDCs also show performance gains, but improvements are limited.

Scarpellini, Robin↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular Distributions of High-Mass Dilepton Production in Hadron Collisions

The SeaQuest experiment is a fixed-target dimuon experiment currently running at the Fermi National Accelerator Laboratory (FNAL). By utilizing the high-intensity, 120 GeV proton beam delivered by the FNAL Main Injector (MI), SeaQuest is able to measure proton-induced Drell-Yan dimuon production off of various nuclear targets in kinematic regions inaccessible to previous similar experiments. A suitably large fraction of the final dataset has been recorded, reconstructed, and analyzed. Very preliminary results from light-sea flavor asymmetry, nuclear dependence, and partonic energy loss analyses have been presented at numerous international conferences. A novel, FPGA-based trigger system has been designed, implemented, and optimized for the SeaQuest experiment. By implementing the trigger decision logic in FPGA firmware, it is more adaptable to changing experimental conditions. Additionally, the peripheral tasks of timing alignment, “trigger matrix” generation, and firmware uploading have been mostly automated, reducing the likelihood of user error in the maintenance and operation of the trigger system. Significant upgrades to hardware and firmware have greatly improved the performance of the trigger system since the 2012 commissioning run of SeaQuest. Four additional v1495 modules were added to facilitate thorough pulser testing of the firmware designs and in-situ pulser tests of all compiled firmware. These pulser tests proved crucial for diagnosing many errors that may have otherwise gone unnoticed. A significant change to the internal clocking of the trigger system eliminated a subtle source of rate-dependent trigger efficiency. With this upgrade, the trigger finally meets the “dead-time free” design specification. Drell-Yan dimuon data have been collected and analyzed for central θCS , with nearly flat acceptance in φCS , in the mass range 5.0 GeV < Mγ* < 10.0 GeV at forward xF with the SeaQuest spectrometer at FNAL. A very preliminary extraction of λ has been performed, and the remaining difficulties in extracting ν have been evaluated. Although the results are not yet publishable, significant progress has been made in developing this very challenging angular distributions analysis. A simple scheme for correcting for the angular acceptances of the spectrometer, trigger, and reconstruction has been developed and demonstrated. A generally applicable correction for the kinematically-dependent, rate-dependent reconstruction efficiency has been developed and applied to all current analyses on SeaQuest data. This rate-dependence correction was the first major hurdle in the path to publication of many preliminary SeaQuest results. The last remaining major correction for all analyses, but especially important for the angular parameter extraction, is the full characterization, rate-dependence correction, and subtraction of the combinatoric background contribution to the reconstructed dimuon sample. Independently, an intuitive, kinematic derivation of the single-event definitions of the Drell-Yan angular parameters has been developed under the assumption of unpolarized annihilating quarks within unpolarized nuclei. At O(αs), where the quarks remain co-planar with the hadrons in the photon rest frame, this kinematic method reproduces the Lam-Tung relation and derives an additional equality for µ2, which is only interpretable for single-event parameters. This method has been extended to the case of quark non- coplanarity, and the coplanar equalities become inequalities. A new equality was discovered, which should be obeyed by single-event parameters even in the case of a non-coplanar quark axis. The non-coplanar parameter relations have been used to derive constraints on the experimentally accessible values of λ and ν. These constraints are compared with existing data and have been found consistent, except in the cases where significant contributions from non-zero Boer-Mulders functions are expected. Finally, the kinematically- derived parameter definitions have been applied to high-precision CMS data. The relative contributions of the qq¯ and qg processes to the Z-boson “Drell-Yan” cross-section have been extracted. Further, an average measure of non-coplanarity, likely caused by O(α2) and higher processes, has been extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗