Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Radar - 449MHz - Forks, WA (FKS) - Raw Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Enhancements and Deployment of the TDAQ System for the Mu2e Experiment

The Real Time Processing Systems Division at Fermilab has deployed new features to the Off-The-Shelf Data Acquisition framework (otsdaq) for the Mu2e experiment. The Mu2e experiment will search for the coherent neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement of 10,000 times over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable at present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system uses otsdaq as its online Data Acquisition System (DAQ) framework. otsdaq integrates the artdaq and art frameworks for event transfer, filtering, and processing. otsdaq is a web-based DAQ software suite focusing on flexibility and scalability and provides a multi-user interface accessible through a web browser. artdaq handles the entire data stream, which is read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events combined with the data flux coming from a cosmic-ray veto (CRV) system. Detector front-ends are configured through the PCIe bus by customized otsdaq plugins. The otsdaq slow controls infrastructure has been further developed using the experimental physics and industrial control system (EPICS) open-source platform for monitoring, controlling, alarming, and archiving. The detector control system (DCS) for Mu2e has been integrated into otsdaq. The production TDAQ and DCS system has been deployed at the experimental hall and is being debugged and optimized for experiment operations. We report on the feature enhancements and deployment of otsdaq for Mu2e.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

2.2.2.405 - Verdant/NREL Research Measurement Campaign

The marine renewable energy industry primarily uses thermoset composite materials for blades and other hydrodynamic components, which can have up to 50% reduction in strength when exposed to seawater and are not recyclable. Thermoplastic composite materials have been shown at a coupon-scale to have improved seawater saturated properties but have not been validated at full scale. The primary goal of the project is to demonstrate the structural properties of thermoplastic-fiberglass composite blades compared to epoxy-fiberglass composite blades in seawater at a tidal energy site on an operational turbine. Through this work, NREL manufactured, tested and deployed thermoplastic blades and a data acquisition system on Verdant Power's turbine TriFrame in the East River, NYC. The thermoplastic blades and DAQ were retrieved after a 6-month deployment with no signs of degradation and all cable connections, structural supports and strain gages had a 100% survival rate. The blades are currently undergoing post-deployment structural validation to compare their performance to traditional epoxy blades that were deployed for the same amount of time. This will increase confidence in thermoplastic materials and move it closer to commercial adoption, as well as increase confidence in the design of a DAQ and instrumentation method for a tidal turbine. However, due to an error in the DAQ software that was introduced after the DAQ and software were validated, there was no loads data collected during the deployment.

blade testing↗

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

The ScIDEP muon radiography project at the Egyptian Pyramid of Khafre

The ScIDEP Collaboration is constructing muon telescopes based on scintillator technology to investigate the internal structure of the Egyptian Pyramid of Khafre at Giza near Cairo using cosmic-ray muons. The collaboration aims to scan the pyramid from multiple viewpoints, both inside the king’s burial chamber that is located centrally at the base of the pyramid, and outside of the pyramid, to potentially identify any new internal structures. An overview of the project is presented, including the development of the data-acquisition system, the simulation framework, and very first detector studies.

47 OTHER INSTRUMENTATION↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83 m Kr are detected via their ≈ 26GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲ 10ms and changing in frequency by ≲ 1MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Ashtari Esfahani, A. [Washington U., Seattle; Shar↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83m Kr are detected via their ≈26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲10 ms and changing in frequency by ≲1 MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. Finally, we describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Data acquisition↗

Testing and validating SMDS algorithms implemented in the cloud

Pacific Northwest National Laboratory (PNNL) provided technical assistance to NorthWrite Inc. under the Small Business Vouchers (SBV) Pilot. NorthWrite delivered services to owners of small commercial buildings, using a cloud-based service to monitor, control, and optimize building operations, saving energy and reducing operating costs for the owners while ensuring that occupant comfort needs were consistently met. NorthWrite had a longstanding desire to add a new suite of diagnostic capabilities to their service offering and had been trying, without success, to incorporate several diagnostic algorithms published by PNNL. These algorithms arise from research previously supported by BTO. Through the SBV awarded to NorthWrite, PNNL made available technical knowledge regarding the derivation and application of the following sets of algorithms for use in the NorthWrite Cloud-based service delivery system: • algorithms for monitoring rooftop packaged air conditioners and heat pumps (often referred to as rooftop units or RTUs) and diagnosing faults in these units, • advanced algorithms for automated fault detection and diagnosis of other equipment found in small buildings, and • algorithms for identifying, prioritizing, and assessing the economic effectiveness of implementing energy saving measures in small commercial buildings based on sensed data. The PNNL researchers involved were the original developers of these algorithms, had a unique understanding of the derivation of the algorithms, and had the source data used for this derivation. Further, the PNNL researchers had extensive experience using these algorithms in the laboratory, unique experience applying these algorithms in real-world small commercial buildings and could solve a number of key problems that NorthWrite and other users faced in using these algorithms at scale. In addition, PNNL had recently installed a pair of RTUs in a laboratory setting that were instrumented and connected with data acquisition systems that provided a unique test rig for validating the algorithms before NorthWrite began to deploy their new services in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Nuclear Criticality Experiments Research Center Futures: A Report of a Workshop held September 6-9, 2022, Los Alamos, NM, November, 2022

Experiments and training with critical assemblies and fissionable material (at or near the critical state) that explore reactivity phenomena are central to a number of national security challenges. From fission energy to nuclear weapons to a broad suite of scientific challenges, it is clear that additional capacity and capability are needed. The National Criticality Experiments Research Center (NCERC) marked 10 years of operations in 2021. This anniversary was an opportune time to celebrate our successes and progress, and to evaluate the remaining and emergent challenges. Against this backdrop, a workshop of approximately 140 national and international leaders in nuclear research was convened in Los Alamos, New Mexico to explore “NCERC Futures.” Therefore, the present workshop focused specifically on needed capabilities and tools to meet the research challenges in eight topical mission areas served by NCERC. As each Topical Group summarized their discussions in the out brief, it was recognized that key challenges could be met through enabling infrastructure investments and new critical assemblies. Enabling infrastructure includes staffing, additional space/buildings, developing an agile bounding safety basis, the ability to keep pace with technological advances in detectors and data acquisition systems (allowing use of those with Bluetooth™ and similar technologies), an expanded set of materials options (especially plutonium), a “Plug and Play” design and implementation mindset, and a facility that enabled free-field measurements. The new critical assemblies that were identified as having the most impact were a bare plutonium (Pu) Critical Assembly, a Horizontal Split Table (HST), a Super Comet, and a Uranium Solution Burst Assembly. NECRC is a unique, one-of-a-kind facility in the United States. If all the improvements were to be made, NCERC would enable the United States and its partners to address many important research questions related to criticality. These include but are not limited to: (1) Covering the entire neutron energy spectrum for both highly enriched uranium (HEU) and Pu in configurations for virtually all conceivable applications; (2) Performing multi-physics solution experiments and irradiations with a Uranium Solution Burst Assembly, which more closely resembles actual criticality accidents; (3) Conducting free-field experiments to make basic fission physics measurements and much cleaner benchmarks with various experimental observables; and (4) Providing more training classes and more experiments annually at greater cost efficiency enabled by additional buildings and machines and an agile, bounding, risk-balanced Safety Basis. In the end, workshop attendees enthusiastically concluded that NCERC Futures are bright and the workshop helped to identify a roadmap of capability gaps that need to be addressed. This report documents the results of those efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗