Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current transformer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗

System for automatically switching transformer coupled lines

A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.

Dwinell, W. S.↗

Equations For Rotary Transformers

Equations derived for input impedance, input power, and ratio of secondary current to primary current of rotary transformer. Used for quick analysis of transformer designs. Circuit model commonly used in textbooks on theory of ac circuits.

Salomon, Phil M.↗

Ramp-up of CHI Initiated Plasmas on NSTX

Experiments on the National Spherical Torus (NSTX) have now demonstrated flux savings using transient coaxial helicity injection (CHI). In these discharges, the discharges initiated by CHI are ramped up with an inductive transformer and exhibit higher plasma current than discharges without the benefit of CHI initiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision current regulator for NMR electromagnets

When using electromagnets or non-persistent superconducting magnets, the field stability can be directly proportional to the current stability. We present in this report a simple design for a current regulator based upon a high-precision, dc-dc fluxgate transformer. The output current and NMR frequency are stabilized by about a factor of 50, over times of order one hour. The method can be applied to essentially any current supply.

59 BASIC BIOLOGICAL SCIENCES↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Kinetics of Nanoparticle Interactions in Battery Electrodes

Nanoparticles with a tendency to phase separate interact with each other during a process of either intraparticle phase separation (occurring inside the particle) or interparticle phase separation (occurring between particles). In this paper, we examine a halfcell consisting of two particles to systematically analyze the particle interactions and their resulting voltage response at different insertion currents. The kinetics of the interactions between nanoparticles is studied for cases in which particles undergo interparticle and intraparticle phase separation. Our results indicate that the interactions between particles in a cell containing only particles that undergo intraparticle phase separation are similar to those in a cell containing only particles that undergo interparticle phase separation. In both cases, sequential transformation occurs at low currents, whereas a simultaneous transformation occurs at high currents. Furthermore, such transformation dynamics changes in cases where the cell contains a mixture of particles that undergo interparticle and intraparticle phase separations, which exhibits more complex dynamics.

25 ENERGY STORAGE↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Chiral currents and static properties of nucleons in holographic QCD

We analyze static properties of nucleons in the two flavor holographic QCD model of Sakai and Sugimoto described effectively by a five-dimensional U(2) Yang-Mills theory with the Chern-Simons term on a curved background. The baryons are represented in this model as a soliton, which at a time slice is approximately the Belavin-Polyakov-Shvarts-Tyupkin (BPST) instanton with a fixed size. First, we construct a chiral current in four dimensions from the Noether current of local gauge transformations which are nonvanishing on the boundaries of the extra dimension. We examine this chiral current for nucleons with quantized collective coordinates to compute their charge distribution, charge radii, magnetic moments, and axial-vector coupling. Most of the results are better close to the experimental values than in the Skyrme model. We discuss the problems of our chiral current, nonuniqueness of the local gauge transformation for defining the current, and its gauge-noninvariance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Open questions: The disrupted circuitry of the cancer cell

Every new decade of biology brings with it a change in outlook driven by new technologies and fresh perspectives. Such is the case for cancer and how we consider the disease. The advent of molecular biology led to the identification of altered signaling molecules and 'oncogenes' that were proposed to drive uncontrolled cell proliferation. The rise of cell biology and new imaging and culturing technologies led to the idea that disruptions in the extracellular environment prime cells for transformation. In the current genomics era, cancer is most commonly seen as a genetic disorder where an unstable genome gives rise to a variety of different cell variants that are selected for proliferation and survival. All of these views are partially correct, of course, and are simply different ways of saying that genetic alterations in cancer cells result in a loss of growth homeostasis. They also take the view that molecular changes 'drive' a cell to grow uncontrollably, rather than tip the balance from one normal state (quiescence) to another (proliferation). Underlying this oversimplification is a profound ignorance of what controls homeostatic cell growth in the first place and how specific mutations impact it.

cancer↗

International Review of Standards and Labeling Programs for Distribution Transformers

Transmission and distribution (T&D) losses in electricity networks represent 8.5% of final energy consumption in the world. In Latin America, T&D losses range between 6% and 20% of final energy consumption, and represent 7% in Chile. Because approximately one-third of T&D losses take place in distribution transformers alone, there is significant potential to save energy and reduce costs and carbon emissions through policy intervention to increase distribution transformer efficiency. A large number of economies around the world have recognized the significant impact of addressing distribution losses and have implemented policies to support market transformation towards more efficient distribution transformers. As a result, there is considerable international experience to be shared and leveraged to inform countries interested in reducing distribution losses through policy intervention. The report builds upon past international studies of standards and labeling (S&L) programs for distribution transformers to present the current energy efficiency programs for distribution transformers around the world.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric-field-induced strain contributions in morphotropic phase boundary composition of (Bi{sub 1/2}Na{sub 1/2})TiO{sub 3}-BaTiO{sub 3} during poling

The microscopic contributions to the electric-field-induced macroscopic strain in a morphotropic 0.93(Bi{sub 1/2}Na{sub 1/2}TiO{sub 3})−0.07(BaTiO{sub 3}) with a mixed rhombohedral and tetragonal structure have been quantified using full pattern Rietveld refinement of in situ high-energy x-ray diffraction data. The analysis methodology allows a quantification of all strain mechanisms for each phase in a morphotropic composition and is applicable to use in a wide variety of piezoelectric compositions. It is shown that during the poling of this material 24%, 44%, and 32% of the total macroscopic strain is generated from lattice strain, domain switching, and phase transformation strains, respectively. The results also suggest that the tetragonal phase contributes the most to extrinsic domain switching strain, whereas the lattice strain primarily stems from the rhombohedral phase. The analysis also suggests that almost 32% of the total strain is lost or is a one-time effect due to the irreversible nature of the electric-field-induced phase transformation in the current composition. This information is relevant to on-going compositional development strategies to harness the electric-field-induced phase transformation strain of (Bi{sub 1/2}Na{sub 1/2})TiO{sub 3}-based lead-free piezoelectric materials for actuator applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication, qualification and test of high Jc ROEBEL YBCO coated conductor cable for HEP magnets

The ROEBEL cable concept allows for a high critical current cable assembled using commercially available YBa{sub 2}Cu{sub 3}O{sub 7-{Delta}} coated conductors. this approach to cable design leads to several technological improvements if applied to the manufacture process of next generation low inductance, high current density HTS coils. A reduction in inductance proves to be extremely important when it comes to protection of coils capable of generating fields in the range of 40-50T, such as the ones needed in the last stage of the cooling channel of a muon collider. In this work several aspects are presented including the qualification and minimum requirements for YBa{sub 2}Cu{sub 3}O{sub 7-{Delta}}coated conductor in terms of 2D current density uniformity and the manufacturing process of ROEBEL cables. Test results achieved using a superconducting transformer for critical current measurements in liquid helium are shown, discussed and compared to the performance of a single YBa{sub 2}Cu{sub 3}O{sub 7-{Delta}} coated conductor tape.

43 PARTICLE ACCELERATORS↗

NASA’s Four-Layer Cake: Systematic Approach for Developing a Digital Transformation Tactical Plan for Organizations

With the current industry movement to “digitally transform” there is much fervor to do something, to change in some way, to do things differently and digitally; however, the last decade has shown that most organizations do not know where to start or abandon transformation efforts. And often the approaches taken fall in the realm of “low-hanging fruit” or “easy wins” which rarely result in the foundational change needed. NASA was no different in the early years of its digital transformation and this drove the development of what eventually became known as the “Four-Layer Cake”. The Four-Layer Cake provides the critical approach for determining the core areas for investment to gain the greatest return without having to boil the ocean or hope that the low-hanging fruit will provide the foundational elements for a domain’s transformation.

Digital engineering↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗