Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

5G Enabled Energy Innovation: Advanced Wireless Networks for Science (Workshop Report)

Rapidly expanding, new telecommunications infrastructure based on 5G technologies will disrupt and transform how we design, build, operate, and optimize scientific infrastructure and the experiments and services enabled by that infrastructure, from continental-scale sensor networks to centralized scientific user facilities, from intelligent Internet of Things devices to supercomputers. Concurrently, 5G will introduce, or exacerbate, challenges related to protecting infrastructure and associated scientific data as well as to fully leveraging opportunities related to expanded infrastructure scale and complexity. The U.S. Department of Energy (DOE) Office of Science operates scientific infrastructure, supporting some of the nation’s most advanced intellectual discoveries, spanning the country and including 30 world-class user facilities from supercomputers to accelerators. Along with field experiments and remote observatories, every aspect of DOE’s scientific enterprise will be affected by 5G, which amounts to a complete renovation of the underpinnings of the nation’s information infrastructure. In this report we explore the scientific opportunities and new research challenges associated with 5G, ranging from scalability to heterogeneity to cybersecurity. The rapid commercial deployment of 5G opens the opportunity to rethink and reinvent DOE’s scientific infrastructure and experimentation, from intelligent sensor networks at unprecedented scales to a digital continuum of cyberinfrastructure spanning low-power sensors, high-performance computing embedded within and at the edge of the network, and DOE’s large-scale user instrument and computing facilities. New programming paradigms, workflow and data frameworks, and AI-based system design, operation, and autonomous adaptation and optimization will be necessary in order to exploit these new opportunities. Field deployments and centralized scientific instruments can also be revolutionized, moving (without traditional performance penalties) from wired to wireless connectivity for data and control systems, improving flexibility, and opening new sensing modalities, including the use of the 5G electromagnetic spectrum itself as an environmental probe. For DOE science, in contrast to commercial 5G applications and settings, devices will be deployed in extreme environments such as cryogenically cooled instrument control systems and in remote settings with harsh conditions, requiring the design of new materials for RF communication and edge processing to operate in these regimes. Concurrently, 5G infrastructure comprises both hardware and sophisticated software systems - currently closed and proprietary. The cybersecurity challenges to 5G-empowered reinvention mirror the complexity and variety of new 5G features, from virtualization to private network slices to ubiquitous access. Research is also needed in order to accelerate the development of secure and open 5G software infrastructure, reducing reliance on hardware and software produced outside the United States and providing the transparency and rigorous evaluation and testing afforded through open software. Twelve broad research thrusts are laid out in four chapters, with a companion fifth chapter (and three additional research thrusts) underscoring the needs and opportunities for an aggressive testbed program co-designed by networking experts and scientists involved in the 15 research thrusts. The urgency of undertaking this research is fueled by a global, accelerating deployment of new telecommunications infrastructure that is designed for entertainment and commercial applications - barely scratching the surface of what 5G can do to extend U.S. leadership in scientific discovery.

42 ENGINEERING↗

Low-loss adiabatic fiber-optic coupler for cryogenic photonics

Recent developments in quantum light–matter coupled systems and quantum transducers have highlighted the need for cryogenic optical measurements. In this study, we present a packaged fiber-optic coupler with a coupling efficiency of over 50% for telecom wavelength light down to the mK temperature range. Besides the high coupling efficiency, our method enables sensitive photonic device measurements that are immune to mechanical vibrations present in cryogenic setups.

Optics↗

IB3A Helium Recovery System

An evaluation of the Fermilab's helium cryogenics test facilities has identified a pressing need for a helium recovery system in the Technical Division's Industrial Building 3a (IB3A). The IB3A facility, which plays a crucial role in testing components for various research projects, including the High-Luminosity LHC Accelerator Upgrade and Mu2e, currently vents helium into the air. Implementing recovery practices is essential due to helium's non-renewable nature and the goal of sustaining the Fermilab's scientific operations long-term. This poster covers benefits helium recovery for Fermilab and highlights the most important aspects of current helium recovery effort.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using statistical modeling to predict and understand fusion experiments

Over 300 cryogenic layered direct-drive inertial confinement fusion implosions have been successfully executed on the OMEGA Laser System in the last decade. However, extracting sufficient understanding from these experiments to develop new designs or to identify or mitigate degradation sources remains challenging. Recently, a statistical modeling approach was developed to successfully design and predict improved implosion experiments on OMEGA. Here, we show that one-dimensional simulations can be used to predict the outcomes of systematically perturbed three-dimensional simulations and that this statistical modeling approach can be used to identify or rule out physical mechanisms for some of the degradation sources observed on the OMEGA Laser System for direct-drive cryogenic inertial confinement fusion. In this instance, we investigate the fusion yield dependencies on the ion temperature asymmetries and laser beam size observed in experiments by comparing with trends in three-dimensional synthetic simulation databases. Using the statistical model on these systematically perturbed simulations, we find that the statistically inferred dependency on the measured ion temperature asymmetries is well explained by imposed ℓ =1 modes. However, we find that the dependency on the laser beam size is only dominated by the illumination non-uniformity for some extreme cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Quantum critical electro-optic and piezo-electric nonlinearities

Although electro-optic (EO) nonlinearities are essential for many quantum and classical photonics applications, a major challenge is inefficient modulation in cryogenic environments. Guided by the connection between phase transitions and nonlinearity, we identify the quantum paraelectric perovskite SrTiO 3 as a strong cryogenic EO [>500 picometers per volt (pm/V)] and piezo-electric material (>90 picocoulombs per newton) at T = 5 K, at frequencies to at least 1 megahertz. Furthermore, by tuning SrTiO 3 toward quantum criticality, we more than double the EO and piezo-electric effects, demonstrating a linear Pockels coefficient above 1000 pm/V. Furthermore, our results probe the link between quantum phase transitions, dielectric susceptibility, and nonlinearity, unlocking opportunities in cryogenic optical and mechanical systems and providing a framework for discovering new nonlinear materials.

Anderson, Christopher P. [Stanford University, CA ↗

The 8RH 2 Process for Producing Clean Hydrogen with Autothermal Reforming and Carbon Capture

The primary objective of this project is to demonstrate the commercial viability and environmental benefits of an 8 Rivers Hydrogen (8RH 2 ) process, a proprietary technology developed to optimally produce high-purity blue H 2 with up to 99% carbon capture. This 8RH 2 process is particularly notable for its integration of a low-energy cryogenic CO 2 separation system that not only maximizes hydrogen recovery but also minimizes the carbon footprint of the operation. This aligns with global environmental goals and supports the United States' push toward energy sustainability and independence.

03 NATURAL GAS↗

A scanning quantum cryogenic atom microscope at 6 K

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identifying Downtime Sources in CEBAF SRF Linac Systems for Improving Its Reliability

In this work, we will present some recent analysis of the reliability statistics of the CEBAF SRF linac systems. Based on the data collected by the existing Down Time Manager (DTM), the year-to-year downtime evolution trend of linac zones over the six-year period from FY18 to FY23 is established. An in-depth downtime analysis at a resolution beyond the linac zone level was carried out by introducing a new system hierarchy, consisting of the SRF linac sub-systems and components. This new paradigm was implemented in a pilot downtime study over the two-month period of CEBAF operation from 9/13/23 to 11/13/23, enabling localization of the responsible sub-systems (SRF, HPRF, LLRF, Beamline vacuum, Cryogenics, etc.) and hardware components (cavity, tuner, RF coupler, etc.) in the CEBAF SRF linac systems. Pinpointing downtime sources over long operation periods at the sub-systems and component levels holds the key to improving the CEBAF SRF systems reliability. It also helps identify areas of SRF technology development needed by future high-power high-reliability CW SRF linacs.

Hryhorenko, Oleksandr↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

A modular chemo-selective oxygen production unit to deliver oxygen for advanced combustion systems

Commercial oxygen generation technologies deploy either cryogenic air separation or vacuum pressure swing adsorption (VPSA). These technologies can provide nearly pure oxygen but are only economically viable at oxygen production rates of 100-7,000 tonnes/day. The state-of-theart cryogenic air separation plants are impending the theoretical limits of thermodynamic efficiency but cannot be scaled down to cater future needs. Therefore, there is great incentive to develop a new approach for oxygen separation that can accommodate the upcoming demands. Our proposed research approach address to find novel methodologies to provide energy efficient modular O 2 on demand systems for modular gasification and other applications. Small scale modular systems for O 2 production offer certain benefits including enhanced energy efficiency, reduced operating costs and flexibility to tailor location specific needs. Our hypothesis is that a small modular system could be engineered using solvent-based capture and thermal release of oxygen, to enable “oxygen on demand” for any combustion-related technology.

42 ENGINEERING↗