Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

188 records · Page 11

Capturing Carbonation: Understanding Kinetic Complexities through a New Era of Electron Microscopy

Cryogenic plasma focused ion beam (PFIB) electron microscopy analysis is applied to visualizing ex situ (surface industrial) and in situ (subsurface geologic) carbonation products, to advance understanding of carbonation kinetics. Ex situ carbonation is investigated using NIST fly ash standard #2689 exposed to aqueous sodium bicarbonate solutions for brief periods of time. In situ carbonation pathways are investigated using volcanic flood basalt samples from Schaef et al. (2010) exposed to aqueous CO 2 solutions by them. The fly ash reaction products at room temperature show small amounts of incipient carbonation, with calcite apparently forming via surface nucleation. Reaction products at 75° C show beginning stages of an iron carbonate phase, e.g., siderite or ankerite, common phases in subsurface carbon sequestration environments. This may suggest an alternative to calcite in carbonation low calcium-bearing fly ashes. Flood basalt carbonation reactions show distinct zonation with high calcium and calcium-magnesium bearing zones alternating with high iron-bearing zones. The calcium-magnesium zones are notable with occurrence of localized pore space. Oscillatory zoning in carbonate minerals is distinctly associated with far-from-equilibrium conditions where local chemical environments fluctuate via a coupling of reaction with transport. The high porosity zones may reflect a precursor phase (e.g., aragonite) with higher molar volume that then “ripens” to the high-Mg calcite phase-plus-porosity. These observations reveal that carbonation can proceed with evolving local chemical environments, formation and disappearance of metastable phases, and evolving reactive surface areas. Together this work shows that future application of cryo-PFIB in carbonation studies would provide advanced understanding of kinetic mechanisms for optimizing industrial-scale and commercial-scale applications.

36 MATERIALS SCIENCE↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Comparative study on the formation of Cr and Ti ohmic contacts to (001) β -Ga 2 O 3

Here, a comparative study of Cr/Au and Ti/Au ohmic contacts on (001) β-Ga 2 O 3 was conducted. The electrical behavior from current-voltage measurements and the interfacial composition and microstructure as determined from high-resolution transmission electron microscopy (TEM) with energy dispersive x-ray analysis were compared for the different contacts at selected points in an annealing series (300–700 °C, 1 min. anneals in N 2 ). Cr/Au contacts became ohmic at temperatures (300–350 °C) approximately 50–100 °C lower than Ti/Au contacts (400–450 °C). Cr/Au and Ti/Au contacts demonstrated optimal ohmic behavior (lowest resistance) when annealed to 450–500 and 500–600 °C, respectively, with Ti/Au contacts yielding a lower total resistance than Cr/Au. Cross-sectional TEM images of Cr/Au contacts annealed at 450 °C revealed the presence of Au nanoclusters at the Ga 2 O 3 interface and CrO x layers at both the top of the contact and the Ga 2 O 3 interface. Whereas TiO x also formed at the top and bottom interfaces in 450 °C-annealed Ti/Au contacts, the TiO x surface layer appeared to be variable in thickness and/or discontinuous, unlike the CrO x surface layer. Au nanoclusters were not detected at the interface in the Ti/Au contacts. The interdiffusion and oxidation observed in both contact metallizations point to the need for diffusion barriers that may allow these contacts to be used in future Ga 2 O 3 -based devices that operate at elevated temperatures.

36 MATERIALS SCIENCE↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Loss Charge Transfer Plasmons in Graphene/α-RuCl 3 Heterostructures Below 40 K

Charge transfer at material interfaces governs a wide range of physical properties, from electronic band structures to emergent collective excitations. In two-dimensional (2D) material heterostructures, charge transfer phenomena play important roles in enabling novel quantum phases, proximity effects, and tunable plasmonic responses. One representative charge transfer interface is formed between α-RuCl 3 , a van der Waals material with high electron affinity, and graphene. Significant charge transfer across this interface induces the formation of charge-transfer plasmon polaritons (CPPs), hybrid excitations between light and charge oscillations. However, previous studies found that as the charge transfer process takes place, α-RuCl 3 becomes lossy, which limits the quality factor of CPPs. Here, we investigate CPPs down to 10 K using a home-built scattering-type scanning near-field optical microscope (s-SNOM) optimized for low-temperature measurements. Our study reveals a dramatic suppression of plasmon loss channels below 40 K, contributing to a significant enhancement in the plasmonic quality factor. This reduction in loss is likely attributed to the blue shift of the correlation-induced Mott gap in α-RuCl 3 with decreasing temperature, along with the reduction of phonon scattering at low temperature. In conclusion, our results highlight the potential of using s-SNOM and CPPs to study complex 2D interfaces and reveal correlated electron dynamics in the underlying material.

36 MATERIALS SCIENCE↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗