ICARUS: new voyage to sterile neutrino search in the Short Baseline Program

The ICARUS collaboration operated the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratories studying neutrino oscillations with the CNGS neutrino beam from CERN, and searching for atmospheric neutrino interactions. ICARUS performed a sensitive search for LSND-like anomalous νe appearance in the CNGS beam, which contributed to the constraints on the allowed parameters to a narrow region around $Δm^2=1 e\text{V}^2$, where all the experimental results can be coherently accommodated at 90% C.L. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS has started operations and is presently in its commissioning phase with the aim of collecting its first neutrino events from the Booster Neutrino Beam and the NuMI off-axis beam. The main goal of the first year of ICARUS data taking will then be the definitive verification of the recent claim by NEUTRINO-4 short baseline reactor experiment both in the $ν_μ$ channel with the BNB and in the $ν_e$ with NuMI. After the first year of operations, ICARUS will commence its search for evidence of a sterile neutrino jointly with the SBND near detector, within the Short Baseline Neutrino (SBN) program. The ICARUS exposure to the NuMI beam will also give the possibility for other physics studies such as light dark matter searches and neutrino-Argon cross section measurements. The proposed contribution addresses ICARUS achievements, its status and plans for the new run at Fermilab and the ongoing developments of the analysis tools needed to fulfill its physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of superconductor and manganin technology for electronic links used in space mission applications

The electronic link connecting cryogenically cooled radiation detectors to data acquisition and signal processing electronics at higher temperatures contributes significantly to the total heat load on spacecraft cooling systems that use combined mechanical and cryogenic liquid cooling. Using high transition temperature superconductors for this link has been proposed to increase the lifetime of space missions. Herein, several YBCO (YBa2Cu3O7) superconductor-substrate combinations were examined and total heat loads were compared to manganin wire technology in current use. Using numerical solutions to the heat-flow equations, it is shown that replacing manganin technology with YBCO thick film technology can extend a 7-year mission by up to 1 year.

Caton, R.↗

Kubernetes for the Deep Underground Neutrino Experiment Data Acquisition

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino experiment based in the USA which is expected to start taking data in 2029. DUNE aims to precisely measure neutrino oscillation parameters by detecting neutrinos from the LBNF beamline (Fermilab) at the Far Detector, 1,300 kilometres away, in South Dakota at the Sanford Underground Research Facility. The Far Detector will consist of four cryogenic Liquid Argon Time Projection Chamber detectors of 17 kT, each producing more than 1 TB/sec of data. The main requirements for the data acquisition system are the ability to run continuously for extended periods of time, with a 99% up-time requirement, and the functionality to record both beam neutrinos and low energy neutrinos from the explosion of a neighbouring supernova, should one occur during the lifetime of the experiment. The key challenges are the high data rates that the detectors generate and the deep underground environment, which places constraints on power and space. To overcome these challenges, DUNE plans to use a highly optimised C++ software suite and a server farm of about 110 nodes continuously running about two hundred multicore processes located close to the detector, 1.5 kilometres underground. Thirty nodes will be at the surface and will run around two hundred processes simultaneously. DUNE is studying the use of the Kubernetes framework to manage containerised workloads and take advantage of its resource definitions and high up-time services to run the DAQ system. Progress in deploying these systems at the CERN neutrino platform on the prototype DUNE experiments is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Optical Detection Of Cryogenic Leaks

Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

Wyett, Lynn M.↗

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of backgrounds events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

47 OTHER INSTRUMENTATION↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and perspective of ICARUS at the Fermilab Short-Baseline Neutrino Program

The ICARUS collaboration has employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurements of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will jointly search for evidence of sterile neutrinos with the Short-Baseline Near Detector (SBND), within the Fermilab Short-Baseline Neutrino (SBN) program. In this presentation, preliminary technical results from the ICARUS data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and its capability to select and reconstruct neutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ICARUS at the Short-Baseline Neutrino program: first results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu_e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 $eV^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this presentation, preliminary results from the ICARUS data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

Artero Pons, Maria↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Experimental design for the evaluation of high-T(sub c) superconductive thermal bridges in a sensor satellite

Infrared sensor satellites, which consist of cryogenic infrared sensor detectors, electrical instrumentation, and data acquisition systems, are used to monitor the conditions of the earth's upper atmosphere in order to evaluate its present and future changes. Currently, the electrical connections (instrumentation), which act as thermal bridges between the cryogenic infrared sensor and the significantly warmer data acquisition unit of the sensor satellite system, constitute a significant portion of the heat load on the cryogen. As a part of extending the mission life of the sensor satellite system, the researchers at the National Aeronautics and Space Administration's Langley Research Center (NASA-LaRC) are evaluating the effectiveness of replacing the currently used manganin wires with high-temperature superconductive (HTS) materials as the electrical connections (thermal bridges). In conjunction with the study being conducted at NASA-LaRC, the proposed research is to design a space experiment to determine the thermal savings on a cryogenic subsystem when manganin leads are replaced by HTS leads printed onto a substrate with a low thermal conductivity, and to determine the thermal conductivities of HTS materials. The experiment is designed to compare manganin wires with two different types of superconductors on substrates by determining the heat loss by the thermal bridges and providing temperature measurements for the estimation of thermal conductivity. A conductive mathematical model has been developed and used as a key tool in the design process and subsequent analysis.

Scott, Elaine P.↗

Design and Performance of the First BICEP Array Receiver

Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity “B-mode” pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision σ(r) between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. Here in this paper, we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

High T(sub c) leads for remote sensing applications

Several NASA programs designed to monitor the Earth's atmosphere from space utilize infrared detectors which operate at or below 4.2 K for optimum performance. At present, the detectors are maintained at cryogenic temperatures by a stored volume of liquid helium. These detectors must be electrically linked to amplification electronics data storage instruments maintained at 80 K. The electrical connections over the temperature gradient account for approximately 20% of the total heat load on the Dewar for some systems, accelerating the boil-off of liquid helium cryogen and reducing the operational lifetime of the space-borne instruments. The recent discovery of high temperature superconductors has provided an opportunity to develop electrically conductive, thermally insulating links to bridge this thermal gradient. This paper describes the modelling of the thermal transport properties of thick film, high T(sub c) electrical bridges across a 4.2-80 K temperature gradient and the impact of such devices on a spaceborne remote sensing system.

Selim, R.↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗