Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “critical loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗

Fitness-for-Service Analysis of Reactor Components under Flexible Load-Following Operating Conditions

Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Super-X and conventional divertor configurations in MAST-U ohmic L-mode; a comparison facilitated by interpretative modelling

Measurements are presented, alongside corresponding interpretative SOLPS-ITER simulations, of the first MAST-U experiments comparing ohmically heated L-mode fuelling scans in Conventional divertor (CD) and Super-X divertor (SXD) configurations. In experiment, at comparable outer mid-plane separatrix electron density, $n_{e,\textrm{sep,OMP}}$, the maximum lower outer target heat load was found to be a factor 16 $\,\pm\,7$ lower in SXD compared to CD. In simulation, a factor 26.8 reduction was found (slightly higher than the experimental range), suggesting an additional reduction in SXD compared to the factor 9.3 expected from geometric considerations alone. According to the simulations, this additional reduction in the SXD is due to a net radial transport of the energy remaining downstream of the $T_e = 5$ eV location. This energy is carried out of the critical (highest heat load) flux tube by deuterium atoms, demonstrating the importance of a longer legged divertor which provides space for this to occur. Importantly, in both simulation and experiment, the SXD has minimal impact on the upstream n e and T e profiles. Spectral inferences of detachment front movement in SXD compare well between simulation and experiment. In regions of high magnetic field gradient, the parallel movement of the front towards the X-point becomes less sensitive to increasing $n_{e,\textrm{sep,OMP}}$, in qualitative agreement with simplified models and previous predictive simulations. Additional aspects, regarding the target ion flux rollover, upstream separatrix temperature and drift effects, are also presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Demonstration of NREL Modeling Capability to Design the Next Generation of Floating Offshore Wind Turbines with Stiesdal and Magellan Wind (Cooperative Research and Development Final Report)

This Technology Commercialization Fund (TCF) CRADA involved demonstration of NREL modeling capability using OpenFAST (formerly known as FAST) to design the next generation of floating offshore wind turbines (FOTW) with Stiesdal’s TetraSpar design. The objective of the project was to enable the design and optimization of next generation FOWT that show promise to make FOWT cost-competitive with other energy technologies by upgrading, verifying, and validating improvements to OpenFAST. This objective was achieved by (1) upgrading OpenFAST to compute floating substructure flexibility and member-level loads, which is critical to enable the design of floating substructures—especially newer designs that are streamlined, flexible, and cost-effective; (2) verifying the new OpenFAST capabilities through model-to-model comparisons and validating the capabilities through comparisons to empirical data generated with wave-tank testing, using TetraSpar data provided by Stiesdal; and (3) making available the upgraded OpenFAST tool to the wind energy community to enable next-generation floating wind designs.

17 WIND ENERGY↗

Particle Size Optimization of Thermochemical Salt Hydrates for High Energy Density Thermal Storage

Thermal energy storage (TES) solutions offer opportunities to reduce energy consumption, greenhouse gas emissions, and cost. Specifically, they can help reduce the peak load and address the intermittency of renewable energy sources by time shifting the load, which are critical toward zero energy buildings. Thermochemical materials (TCMs) as a class of TES undergo a solid–gas reversible chemical reaction with water vapor to store and release energy with high storage capacities (600 kWh m −3 ) and negligible self‐discharge that makes them uniquely suited as compact, stand‐alone units for daily or seasonal storage. However, TCMs suffer from instabilities at the material (salt particles) and reactor level (packed beds of salt), resulting in poor multi‐cycle efficiency and high‐levelized cost of storage. In this study, a model is developed to predict the pulverization limit or R crit of various salt hydrates during thermal cycling. This is critical as it provides design rules to make mechanically stable TCM composites as well as enables the use of more energy‐efficient manufacturing process (solid‐state mixing) to make the composites. The model is experimentally validated on multiple TCM salt hydrates with different water content, and effect of R crit on hydration and dehydration kinetics is also investigated.

25 ENERGY STORAGE↗

Shock-induced transformation of nitinol shape memory alloy: Effect of stress state on transformation

Due to its numerous practical applications and intriguing phase transformation behavior, shape memory alloys (SMAs) have garnered significant research and development interests. In the past, most studies on the mechanical behavior of SMAs have been conducted under uniaxial stress loadings. Limited research on SMAs under shock loading has not provided conclusive results regarding their transformation behavior and transformation stress under such loading. Additionally, there is a lack of comprehensive understanding regarding the effects of different stress states on transformation behavior. The main objectives of this study are to address these issues. To achieve these objectives, a series of shock wave experiments were designed and conducted. Additionally, quasi-static and dynamic uniaxial stress experiments were carried out to establish a baseline for comparison. The results revealed that the transformation stress under dynamic uniaxial strain shock loading was approximately 1.92 GPa in contrast to 0.5 GPa (quasi-static) to 0.8 GPa (dynamic) observed in uniaxial stress loading. The transformation behavior exhibited noticeable rate sensitivity for both types of loading. There appeared to be a critical strain rate above which the austenite phase was driven to a metastable state. This estimated critical axial strain rate along the loading direction was approximately 2 × 10 3 /s–4 × 10 3 /s for uniaxial stress loading and approximately 2 × 10 6 /s for uniaxial strain loading. The apparent high transformation stress for uniaxial strain loading can likely be attributed to a combination of high-pressure confinement and high strain rate. Furthermore, determining their relative contributions remains an open issue.

36 MATERIALS SCIENCE↗

Modeling ethanol/water adsorption in all-silica zeolites using the real adsorbed solution theory

A comprehensive set of single-component and binary isotherms were collected for ethanol/water adsorption into the siliceous forms of 185 known zeolites using grand-canonical Monte Carlo simulations. Using these data, a systematic analysis of ideal/real adsorbed-solution theory (IAST/RAST) was conducted and activity coefficients were derived for ethanol/water mixtures adsorbed in different zeolites based on RAST. It was found that activity coefficients of ethanol are close to unity while activity coefficients of water are larger in most zeolites, indicating a positive excess free energy of the mixture. This observation can be attributed to water/ethanol interactions being less favorable than water/water interactions in the single-component adsorption of water at comparable loadings. The deviation from ideal behavior can be highly structure-dependent but no clear correlation with pore diameters was identified. Furthermore, our analysis also demonstrates the following: (1) accurate unary isotherms in the low-loading regime are critical for obtaining physically sensible activity coefficients; (2) the global regression scheme to solve for activity model parameters performs better than fitting activity models to activity coefficients calculated locally at each binary state point; and (3) including the dependence on adsorption potential offers only a minor benefit for describing binary adsorption at the lowest fugacities. Finally, the Margules activity model was found incapable of capturing the non-ideal adsorption behavior over the entire range of fugacities and compositions in all zeolites, but for conditions typical of solution-phase adsorption, RAST predictions using zeolite-specific or even bulk Margules parameters provide an improved description compared to IAST.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plant SWEETs: from sugar transport to plant–pathogen interaction and more unexpected physiological roles

Abstract Sugars Will Eventually be Exported Transporters (SWEETs) have important roles in numerous physiological mechanisms where sugar efflux is critical, including phloem loading, nectar secretion, seed nutrient filling, among other less expected functions. They mediate low affinity and high capacity transport, and in angiosperms this family is composed by 20 paralogs on average. As SWEETs facilitate the efflux of sugars, they are highly susceptible to hijacking by pathogens, making them central players in plant–pathogen interaction. For instance, several species from the Xanthomonas genus are able to upregulate the transcription of SWEET transporters in rice (Oryza sativa), upon the secretion of transcription-activator-like effectors. Other pathogens, such as Botrytis cinerea or Erysiphe necator, are also capable of increasing SWEET expression. However, the opposite behavior has been observed in some cases, as overexpression of the tonoplast AtSWEET2 during Pythium irregulare infection restricted sugar availability to the pathogen, rendering plants more resistant. Therefore, a clear-cut role for SWEET transporters during plant–pathogen interactions has so far been difficult to define, as the metabolic signatures and their regulatory nodes, which decide the susceptibility or resistance responses, remain poorly understood. This fuels the still ongoing scientific question: what roles can SWEETs play during plant–pathogen interaction? Likewise, the roles of SWEET transporters in response to abiotic stresses are little understood. Here, in addition to their relevance in biotic stress, we also provide a small glimpse of SWEETs importance during plant abiotic stress, and briefly debate their importance in the particular case of grapevine (Vitis vinifera) due to its socioeconomic impact.

Breia, Richard↗

Environmental Influence on Fracture and Delamination of Electrically Conductive Adhesives

This paper presents our continued work on developing a degradation model for electrically conductive adhesive (ECA) interconnects in photovoltaic modules. Here, we characterize the fracture mechanics properties of an epoxy based ECA, for both critical and subcritical loading conditions. Emphasis is put on the influence of different environmental conditions such as temperature and humidity. We found that high levels of humidity not only weaken the adhesive joint but also promote subcritical debonding at significantly lower driving forces than in dry environments.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Models implemented in the methodological approach to design the initial STEP first wall contour

The official Spherical Tokamak for Energy Production mission aims to demonstrate the ability to generate net electricity from fusion with the STEP Prototype Power plant. One of the key technological and engineering challenges in fusion power plants is managing the loads on the first wall within acceptable limits. Therefore, the conceptual design development of the STEP Prototype Power plant needs to be based on load estimates derived using legitimate plasma physics assumptions through dynamic and flexible tools. The current design foresees the STEP main chamber first wall to withstand steady-state heat loads of up to ~1 MW/m 2 , excluding critical regions expected to receive higher heat loads such as the baffle regions approaching the divertors. These critical areas will require ad hoc assessments and will be designed with the presence of limiters. This article focuses on the models and methodology adopted for designing the 2-D poloidal contour of the STEP first wall, based on the anticipated charged particle and radiation heat loads during normal operation. Firstly, the models adopted for calculating the charged particle and radiation heat loads are introduced. The first model is validated through benchmarking against the particle tracing code SMARDDA, while the second model is verified by comparing it with data from the MAST-U experiment. Secondly, the model used to design the 2-D first wall contour according to the heat loads is explained. We acknowledge that this preliminary design stage assumes certain simplifications, notably an axisymmetric geometry, for computational efficiency and clarity in presentation. It is understood that subsequent design phases will address the complexities of real-world engineering, including non-axisymmetric effects, transient plasma scenarios, and the impact of disruptions on the first wall design. Finally, an automatic procedure based on these models is presented for defining the 2-D poloidal contour of the STEP first wall to minimize heat loads, taking into account the need to radiate most of the alpha-particle and auxiliary heating power. Here, by providing an overview of the models, methodology, and an automatic procedure, this paper contributes to the design process of the STEP first wall, addressing the engineering challenges associated with fusion power plant development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

A methodology to compute the critical current limit in Nb3Sn magnets

Numerous experiments have shown that the loads applied to Nb3Sn strands and cables can reduce their critical current. Experiments, performed on uniaxially loaded strands, allowed to define clear laws to describe the evolution of the critical surface as a function of the applied current, field, temperature and strain. It is, however, still unclear how these laws can be applied to superconducting magnets. The present paper proposes a methodology to estimate the critical current and temperature margin reduction on superconducting magnets due to stress on the superconducting material. The methodology is tested on the MQXF magnets, a quadrupole developed for the High Luminosity LHC project, and successfully validated by comparing computed strain with data from strain gauge measurements. Overall, results suggested that, because of the stresses arising in winding during assembly, cool-down and powering, the current limit of the magnet is lower than the expected short sample limit, and that the most critical region does not coincide with the peak field location.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Load Shedding as Part of Primary Frequency Response To Support Networked Microgrid Operations

Global changes in the deployment of distributed energy resources, control and communications technologies, business models, and regulatory policy are increasing the operational options for future distribution systems. One such option is the coordinated operation of distributed resources to form microgrids and networks of microgrids to support traditional bulk power systems during normal operations and critical end-use loads during outages. While individual standalone microgrids have been extensively studied and deployed, the coordinated operation of networked microgrids is operationally more challenging due to the dynamic boundaries and changing mix of generation resources. Here, this paper presents a method of using a distributed control architecture to support primary frequency response in networked microgrids operations. The support of primary frequency response is accomplished using the Open Field Message Bus reference architecture and Grid Friendly Appliance controllers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗