Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Swift and extensive Omicron outbreak in China after sudden exit from ‘zero-COVID’ policy

In late 2022, China transitioned from a strict ‘zero-COVID’ policy to rapidly abandoning nearly all interventions and data reporting. This raised great concern about the presumably-rapid but unreported spread of the SARS-CoV-2 Omicron variant in a very large population of very low pre-existing immunity. By modeling a combination of case count and survey data, we show that Omicron spread extremely rapidly, at a rate of 0.42/day (95% credibility interval: [0.35, 0.51]/day), translating to an epidemic doubling time of 1.6 days ([1.6, 2.0] days) after the full exit from zero-COVID on Dec. 7, 2022. Consequently, we estimate that the vast majority of the population (97% [95%, 99%], sensitivity analysis lower limit of 90%) was infected during December, with the nation-wide epidemic peaking on Dec. 23. Overall, our results highlight the extremely high transmissibility of the variant and the importance of proper design of intervention exit strategies to avoid large infection waves.

60 APPLIED LIFE SCIENCES↗

Improving I/O-aware Workflow Scheduling via Data Flow Characterization and trade-off Analysis

The scientific computing paradigm has transitioned from compute-intensive to I/O-intensive and memory-intensive in the past decade, especially when data-driven science has become common practice. Numerous empirical I/O-aware scheduling optimizations have been developed by incorporating I/O capacity and bandwidth as constraints into scheduling. Unfortunately, there is a lack of data flow (I/O) characterization tool and an understanding of trade-offs between concurrency, locality, and I/O bandwidth. To bridge the gap, this work 1) presents a set of descriptors to characterize, organize, and visualize I/O profiles, including flow size, I/O bandwidth, and operation count, which group data flows by I/O types, tasks, and files; 2) proposes an I/O Roofline model-based trade-off analysis to find the optimal trade-off between flow operational intensity, concurrency, and flow performance. The I/O descriptors generate useful insights into complicated I/O behaviors, suggesting distinct concurrency, storage, and scheduling to be used by types, tasks, and files. The proposed trade-off analysis guides scheduling decisions that generate resource assignment with the best flow parallelism. We evaluate our I/O-aware scheduling methodology on a highly I/O-intensive workflow–1000 Genomes. The experimental results demonstrate speedups of up to 2.4× compared to the state-of-the- art methods.

Guo, Luanzheng [BATTELLE (PACIFIC NW LAB)]↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data? [Slides]

Importance of nuclear data to bias changed significantly when including diverse measurement sets. LLNL pulsed sphere measurements provided information for 9 Be nuclear data above 2 MeV and subcritical benchmarks provided information for 240 Pu nuclear data between 100 keV and 10 MeV. Pulsed sphere leakage spectra and neutron noise observables are differently sensitive to nuclear data compared to critical benchmarks. Leakage spectra are sensitive to nuclear data above 5 MeV. Count rate and Feynman Y are more sensitive to nuclear data. A change in bias can help evaluators identify discrepant nuclear data. In the future, EUCLID plans to perform RAFIEKI analysis with additional benchmark and measurement sets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental cross sections for L-shell x-ray production and ionization by protons

Tables of compiled cross sections list data for production of individual line and total L x-rays as well as for ionization of L subshells and the total L shell. The present cumulative compilation covers some six decades of measurements on targets from {sub 10}Ne to {sub 95}Am bombarded by protons ranging from 10 keV to 1 GeV. It includes data published in the period 1954–1992 from tables published in this journal, cross sections that were not reported in those tables, and new data from works published after 1992. Existing empirical, semiempirical, and theoretical analyses based on, and relative to, the pre-1993 database are reviewed. The experimental details are summarized for pre-1993 articles that were not referenced in previous compilations and, continuing the practice of these compilations, for each new publication. Covering the period 1954–December 2012, the present tabulation collects (not counting 2519 new data for L{sub β1,3,4}, L{sub β2,15},L{sub γ1}, L{sub γ2,3}, and L{sub γ4,4{sup ′}} x ray production) circa 15 500 experimental cross sections and enlarges the database from the previously published tables by 94%. -- Highlights: •An updated database is presented, increasing by 94% the earlier pre-1993 database. •The update has 40% more data from the pre-1993 period, absent in prior compilations. •The growth and possible saturation in the number of data is illustrated. •Ionization cross sections are reconverted to x-ray production cross sections. •Elements and ion energies are identified where measurements are still necessary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Disdrometer and Tipping Bucket Rain Gauge Handbook

The Distromet disdrometer model RD-80 and NovaLynx tipping bucket rain gauge model 260-2500E-12 are two devices deployed a few meters apart to measure the character and amount of liquid precipitation. The main purpose of the disdrometer is to measure drop size distribution, which it does over 20 size classes from 0.3 mm to 5.4 mm. The data from both instruments can be used to determine rain rate. The disdrometer results can also be used to infer several properties including drop number density, radar reflectivity, liquid water content, and energy flux. Two coefficients, N0 and Λ, from an exponential fit between drop diameter and drop number density, are routinely calculated. Data are collected once a minute. The instruments make completely different kinds of measurements. Rain that falls on the disdrometer sensor moves a plunger on a vertical axis. The disdrometer transforms the plunger motion into electrical impulses whose strength is proportional to drop diameter. The rain gauge is the conventional tipping bucket type. Each tip collects an amount equivalent to 0.01 in. of water, and each tip is counted by a data acquisition system anchored by a Campbell CR1000 data logger.

54 ENVIRONMENTAL SCIENCES↗

HeCS-SZ: The hectospec survey of Sunyaev–Zeldovich-selected clusters

We estimate cluster masses and velocity dispersions for 123 clusters from optical spectroscopy to compare the Sunyaev–Zeldovich (SZ) mass proxy and dynamical masses. Our new survey, HeCS-SZ (Hectospec Cluster Survey of SZ-selected clusters), includes 7721 new or remeasured redshifts from MMT/Hectospec observations of 21 SZ-selected clusters at redshifts z = 0.05–0.20. We supplement the Hectospec data with spectra from the Sloan Digital Sky Survey (SDSS) and cluster data from the Cluster Infall Regions in SDSS project and the Hectospec Cluster Survey, our Hectospec survey of clusters selected by X-ray flux. We measure the scaling relation between velocity dispersion and SZ mass estimates from the integrated Compton parameter for an SZ-complete sample of 83 clusters. The observed relation agrees very well with a simple virial scaling from mass (based on SZ) to velocity dispersion. The SZ mass estimates (calibrated with hydrostatic X-ray mass estimates) are not significantly biased compared to dynamical mass estimates under the assumption of small velocity bias of galaxies compared to dark matter particles. Significant mass bias in SZ mass estimates could relieve tension between cosmological results from Planck SZ cluster counts and Planck CMB data. In principle, SZ mass bias and velocity bias of galaxies could conspire to yield good agreement, but the required velocity bias is σ{sub galaxy}≈0.77σ{sub DM}, outside the range of recent models of velocity bias in the literature. More likely, SZ mass bias and velocity bias are both small, and the tension between SZ cluster counts and CMB data requires another explanation.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid, non-destructive carbon analysis of forest soils using neutron-induced gamma-ray spectroscopy

Forest soils are pivotal to understanding global carbon (C) cycling and evaluating policies for mitigating global change. However, they are very difficult to monitor because of the heterogeneity of soil characteristics, the difficulty of representative sampling, and the slow time scale of response to environmental change. Here we demonstrate that use of gamma-ray spectroscopy facilitates in situ non-destructive analysis of C and other elements in forest soils. In this approach the element-specific gamma-rays are induced by fast and thermal neutrons interacting with the nuclei of the elements present in the soil. Background gamma-rays emanating from naturally occurring radionuclides in the forest are recorded as well. We applied this approach in a mature northern hardwood forest on glacial till soils at the Bartlett Experimental Forest in New Hampshire, USA. The inelastic neutron scattering (INS) system yielded strong signals in gamma-ray counts/h, from C and other elements present in the soil matrix that included silicon, oxygen, hydrogen, iron, aluminum, manganese and potassium. The INS sensitivity for carbon was 20.656 counts h{sup -1} kg{sup -1} C m{sup -2} based on current net C gamma-ray counts and the data for the O horizon and mineral soil to a depth of 30 cm obtained from a nearby quantitative soil pit (7.35 kg C m{sup -2}). We estimate the minimum detectable change to be {approx}0.34 kg C m{sup -2}, which is {approx}5% of the current soil C content, and the minimum detectable limit to be {approx}0.23 kg C m{sup -1}. Eight % reproducibility from 11 measurements was limited, in part, by the large variability in the system counting geometry due to the uneven forest microtopography. The INS approach has the potential to revolutionize belowground monitoring of C and other elements, because the possibility of detecting a 5% change in forest soils has not been possible with destructive sampling methods.

08 HYDROGEN↗

A Bayesian Approach for Extracting Fluorescence Lifetimes from Sparse Data Sets and Its Significance for Imaging Experiments

The measurement of fluorescence lifetimes, especially in small sample volumes, presents the dual challenge of probing a small number of fluorophores and fitting the concomitant sparse data set to the appropriate excited-state decay function. A common method of analysis, such as the maximum likelihood (ML) technique, assumes a uniform probability distribution of the parameters describing the fluorescence decay function. An improvement is thus suggested by implementing a suitable nonuniform distribution, as is provided by a Bayesian framework, where the distribution of parameters is obtained from both their prior knowledge and the evidence-based likelihood of an event for a given set of parameters. We have also considered the Dirichlet prior distribution, whose mathematical form enables analytical solutions of the fitting parameters to be rapidly obtained. If Gaussian and exponential prior distributions are judiciously chosen, they reproduce the experimental target lifetime to within 20% with as few as 20 total photon counts for the data set, as does the Dirichlet prior distribution. But because of the analytical solutions afforded by the Dirichlet prior distribution, it is proposed to employ a Dirichlet prior to search parameter space rapidly to provide, if necessary, appropriate parameters for subsequent employment of a Gaussian or exponential prior distribution

97 MATHEMATICS AND COMPUTING↗

Knockdown of Trnau1ap inhibits the proliferation and migration of NIH3T3, JEG-3 and Bewo cells via the PI3K/Akt signaling pathway

Highlights: • Knockdown of Trnau1ap attenuated cellular antioxidant activity. • Knockdown of Trnau1ap reduced cell migration and proliferation. • Knockdown of Trnau1ap blocked the PI3K/Akt signaling pathway. The tRNA selenocysteine 1 associated protein 1 (Trnau1ap, initially named SECp43) is involved in Selenocysteine (Sec) biosynthesis and incorporation into selenoproteins, which play a key role in biological processes, such as embryonic development. We previously reported that downregulation of Trnau1ap inhibited proliferation of cardiomyocyte-like H9c2 cells. However, the effects of Trnau1ap on cell proliferation and migration of embryonic development are not known, and the mechanisms remain elusive. Herein, lentiviral shRNA vectors were transfected in NIH3T3, JEG-3 and Bewo cells (embryonic, trophoblast and placental cells). We found that knockdown of Trnau1ap resulted in reduced expression levels of selenoproteins. The data of Cell Count Kit-8 (CCK-8) assay and wound scratch assay revealed the proliferation and migration rates were reduced in the Trnau1ap-shRNA groups. Furthermore, western blot analysis showed that the phosphorylation level of Akt in the phosphatidylinositol 3-kinase (PI3K)/Akt pathway was attenuated. These results indicate that Trnau1ap plays an important role in regulation of cell proliferation and migration through the PI3K/Akt signaling pathway, as well as being essential for embryonic development by regulating the expression of selenoproteins.

60 APPLIED LIFE SCIENCES↗

Metrological characterization of X-ray diffraction methods at different acquisition geometries for determination of crystallite size in nano-scale materials

Crystallite size values were determined by X-ray diffraction methods for 183 powder samples. The tested size range was from a few to about several hundred nanometers. Crystallite size was calculated with direct use of the Scherrer equation, the Williamson–Hall method and the Rietveld procedure via the application of a series of commercial and free software. The results were statistically treated to estimate the significance of the difference in size resulting from these methods. We also estimated effect of acquisition conditions (Bragg–Brentano, parallel-beam geometry, step size, counting time) and data processing on the calculated crystallite size values. On the basis of the obtained results it is possible to conclude that direct use of the Scherrer equation, Williamson–Hall method and the Rietveld refinement employed by a series of software (EVA, PCW and TOPAS respectively) yield very close results for crystallite sizes less than 60 nm for parallel beam geometry and less than 100 nm for Bragg–Brentano geometry. However, we found that despite the fact that the differences between the crystallite sizes, which were calculated by various methods, are small by absolute values, they are statistically significant in some cases. The values of crystallite size determined from XRD were compared with those obtained by imaging in a transmission (TEM) and scanning electron microscopes (SEM). It was found that there was a good correlation in size only for crystallites smaller than 50 – 60 nm. Highlights: • The crystallite sizes for 183 nanopowders were calculated using different XRD methods • Obtained results were subject to statistical treatment • Results obtained with Bragg-Brentano and parallel beam geometries were compared • Influence of conditions of XRD pattern acquisition on results was estimated • Calculated by XRD crystallite sizes were compared with same obtained by TEM and SEM.

36 MATERIALS SCIENCE↗

SPITZER INFRARED SPECTROMETER 16 {mu}m OBSERVATIONS OF THE GOODS FIELDS

We present Spitzer 16 {mu}m imaging of the Great Observatories Origins Deep Survey (GOODS) fields. We survey 150 arcmin{sup 2} in each of the two GOODS fields (North and South), to an average 3{sigma} depth of 40 and 65 {mu}Jy, respectively. We detect {approx}1300 sources in both fields combined. We validate the photometry using the 3-24 {mu}m spectral energy distribution of stars in the fields compared to Spitzer spectroscopic templates. Comparison with ISOCAM and AKARI observations in the same fields shows reasonable agreement, though the uncertainties are large. We provide a catalog of photometry, with sources cross-correlated with available Spitzer, Chandra, and Hubble Space Telescope data. Galaxy number counts show good agreement with previous results from ISOCAM and AKARI with improved uncertainties. We examine the 16-24 {mu}m flux ratio and find that for most sources it lies within the expected locus for starbursts and infrared luminous galaxies. A color cut of S{sub 16}/S{sub 24}>1.4 selects mostly sources which lie at 1.1 < z < 1.6, where the 24 {mu}m passband contains both the redshifted 9.7 {mu}m silicate absorption and the minimum between polycyclic aromatic hydrocarbon emission peaks. We measure the integrated galaxy light of 16 {mu}m sources and find a lower limit on the galaxy contribution to the extragalactic background light at this wavelength to be 2.2 {+-} 0.2 nW m{sup -2} sr{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Inference with minimal Gibbs free energy in information field theory

Non-linear and non-Gaussian signal inference problems are difficult to tackle. Renormalization techniques permit us to construct good estimators for the posterior signal mean within information field theory (IFT), but the approximations and assumptions made are not very obvious. Here we introduce the simple concept of minimal Gibbs free energy to IFT, and show that previous renormalization results emerge naturally. They can be understood as being the Gaussian approximation to the full posterior probability, which has maximal cross information with it. We derive optimized estimators for three applications, to illustrate the usage of the framework: (i) reconstruction of a log-normal signal from Poissonian data with background counts and point spread function, as it is needed for gamma ray astronomy and for cosmography using photometric galaxy redshifts, (ii) inference of a Gaussian signal with unknown spectrum, and (iii) inference of a Poissonian log-normal signal with unknown spectrum, the combination of (i) and (ii). Finally we explain how Gaussian knowledge states constructed by the minimal Gibbs free energy principle at different temperatures can be combined into a more accurate surrogate of the non-Gaussian posterior.

79 ASTRONOMY AND ASTROPHYSICS↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Here in this study, the impact of pollen as a PV soiling agent is investigated. The performance data of five utility-scale PV plants in North Carolina, USA, was collected and analyzed using two soiling extraction methods. Satellite and environmental data, including pollen counts, cropland, and vegetation, was also collected and analyzed to identify impacts to soiling losses. During the spring peak pollen season, performance losses of >15% were observed at all five sites. Partial performance recoveries following the pollen season were slow, with lack of correlation with rainfall. This means that the statistical soiling estimation methods that assume abrupt performance recovery from rain are not appropriate for pollen-impacted solar sites. When manual cleanings were performed on site the performance recovery ranged from 5% to 11% indicating persistent soiling impacts are present in this region. The results of this work provide new insights into the phenomenon of pollen deposition on PV systems, demonstrating that 1) soiling can also affect systems located in rainy locations and 2) that its effects cannot be determined using the current estimation methodologies.

14 SOLAR ENERGY↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-P-31: Quantifying the Amount of Missing Tissue in a Digital Breast Tomosynthesis

Purpose: To automatically quantify the amount of missing tissue in a digital breast tomosynthesis system using four stair-stepped chest wall missing tissue gauges in the Tomophan™ from the Phantom Laboratory and image processing from Image Owl. Methods: The Tomophan™ phantom incorporates four stair-stepped missing tissue gauges by the chest wall, allowing measurement of missing chest wall in two different locations along the chest wall at two different heights. Each of the four gauges has 12 steps in 0.5 mm increments rising from the chest wall. An image processing algorithm was developed by Image Owl that first finds the two slices containing the steps then finds the signal through the highest step in all four gauges. Using the signal drop at the beginning of each gauge the distance to the end of the image gives the length of the missing tissue gauge in millimeters. Results: The Tomophan™ was imaged in digital breast tomosynthesis (DBT) systems from various vendors resulting in 46 cases used for testing. The results showed that on average 1.9 mm of 6 mm of the gauges are visible. A small focus group was asked to count the number of visible steps for each case which resulted in a good agreement between observer counts and computed data. Conclusion: First, the results indicate that the amount of missing chest wall can differ between vendors. Secondly it was shown that an automated method to estimate the amount of missing chest wall gauges agreed well with observer assessments. This finding indicates that consistency testing may be simplified using the Tomophan™ phantom and analysis by an automated image processing named Tomo QA. In general the reason for missing chest wall may be due to a function of the beam profile at the chest wall as DBT projects through the angular sampling. Research supported by Image Owl, Inc., The Phantom Laboratory, Inc. and Raforninn ehf; Mallozzi and Healy employed by The Phantom Laboratory, Inc.; Goodenough is a consultant to The Phantom Laboratory, Inc.; Fredriksson, Kristbjornsson, Olafsson, Oskarsdottir and Olafsdottir are employed by Raforninn, Ehf.

60 APPLIED LIFE SCIENCES↗

Studies of the Electromagnetic Structure of Mesons at Jefferson Lab

The Jefferson Laboratory Hall B PrimEx Collaboration is using tagged photons to perform an absolute 1.4% level cross section measurement of the photoproduction of neutral pions in the Coulomb field of a nucleus. The absolute cross section for this process is directly proportional to the neutral pion radiative decay width and consequently the uncertainty in the luminosity is directly reflected in the final error bar of the measurement. The PI has taken primary responsibility for the photon flux determination and in this technical report, we outline the steps taken to limit the uncertainty in the tagged photon flux to the 1% level. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and updated procedures for postbremsstrahlung electron counting. The photon tagging technique has been used routinely in its various forms to provide quasimonochromatic photons for absolute photonuclear cross section measurements. The analysis of such experiments in the context of bremsstrahlung photon tagging was summarized by Owens in 1990. Since then, a number of developments have made possible significant improvements in the implementation of this technique. Here, we describe the steps taken by the PrimEx Collaboration in Hall B of Jefferson Laboratory to limit the systematic uncertainty in the absolute photon flux to 1%. They include an absolute flux calibration at low intensity with a total absorption counter, online relative flux monitoring with a pair spectrometer, and the use of multihit time to digital converters for post bremsstrahlung electron counting during production data runs. While this discussion focuses on the analysis techniques utilized by the PrimEx Collaboration which involves a bremsstrahlung based photon tagging system to measure the neutral pion lifetime, the methods described herein readily apply to other types of photon tagging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adjoint-Based Uncertainty Quantification with MCNP

This work serves to quantify the instantaneous uncertainties in neutron transport simulations born from nuclear data and statistical counting uncertainties. Perturbation and adjoint theories are used to derive implicit sensitivity expressions. These expressions are transformed into forms that are convenient for construction with MCNP6, creating the ability to perform adjoint-based uncertainty quantification with MCNP6. These new tools are exercised on the depleted-uranium hybrid LIFE blanket, quantifying its sensitivities and uncertainties to important figures of merit. Overall, these uncertainty estimates are small (< 2%). Having quantified the sensitivities and uncertainties, physical understanding of the system is gained and some confidence in the simulation is acquired.

42 ENGINEERING↗