Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrosion control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2023

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2022 International Conference on Environmental Systems (ICES) paper number 97. This paper provides the technical background and performance test results (ongoing long-term silver ion release testing and product variability testing) from the silver chloride (AgCl) NP/PU composite foams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2024

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2023 International Conference on Environmental Systems (ICES) paper number 251. This paper provides the technical background and performance results for the product variability testing and microbial check valve (MCV) testing of the silver chloride (AgCl) NP/PU composite foams, referred to as AgFoams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D Irwin↗

Magnetohydrodynamic and Paramagnetic Phenomena in Electrochemistry with Diamagnetic and Ferromagnetic Millielectrodes

There are three kinds of body forces operating in electrolytic solutions in the magnetic field: the magnetohydrodynamic force F(sub B) (=i x B), the F(sub delB) force (approximately B(raised dot)gradB) and the F(sub delC) force (approximately |B|(sup 2)gradC). These three forces manifest themselves differently, depending on the experimental conditions. Thus, diamagnetic disc millielectrodes (e.g., Au) with their plane parallel to the flux density of the homogeneous magnetic field of an electromagnet yield convective behavior analogous to that observed with rotating electrodes; that response is controlled by F(sub B). The same electrodes placed in the inhomogeneous field of a strong permanent magnet yield also convective behavior that is controlled by both F(sub B) and F(sub delB). Finally, similarly sized millielectrodes made of permanent magnets (e.g., Au-coated Nd-Fe-B discs) yield diffusion-controlled behavior at conditions where a gold disc electrode shows behavior dominated by density gradient driven natural convection; in this case the predominant forces are both F(sub delB) and F(sub delC). Under open circuit conditions, ferromagnetic (i.e., magnetizable) millielectrodes (Co, Fe, Ni) dipped in corrosive solutions and placed in homogeneous magnetic fields yield mass-transfer phenomena that seem to be controlled by magnetophoresis.

Leventis, Nicholas↗

Corrosion properties of second-generation conductive materials

Since the introduction of silver-filled epoxy adhesives and silver-filled nitrocellulose lacquer as RFI control materials, a number of new materials have been introduced. The resin carriers have been changed in an effort to make the materials more usable or more EPA acceptable and the fillers have been varied in an effort to make the materials less costly. The corrosion-related properties of second-generation materials were assessed, including adhesives, caulks, and greases. Aluminum 2024 was used as the only substrate material. Ten days of salt fog was used as the corrosive environment. If a noble material such as silver, nickel, or carbon is sandwiched with aluminum an increase in dc resistance results given enough time. If this is unsatisfactory electrically it should either not be used or have all corrosive environments excluded.

Groshart, E.↗

Silver Foam A Long-Term Passive Biocide for Potable Water Systems: 2020 Update

A spacecraft water disinfection system suitable for extended length space exploration missions should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically-influenced corrosion. In addition, the system should have minimal maintenance requirements, the effluent should be chemically compatible with all materials in contact with the water, be safe for human consumption, and suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad spectrum biocide and the chosen potable water biocide for future exploration missions. The leading technology for actively dosing silver in future water systems is based on electrolytic production. Several challenges remain with this approach which have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle (NP)/polyurethane (PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2019 International Conference on Environmental Systems (ICES) paper of the same name. In this paper, the technical background and results from the updated silver chloride (AgCl) NP/PU composite foam synthesis and property testing is provided. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Irwin, Tesia D.↗

Corrosion of metal samples rapidly measured

Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

Maskell, C. E.↗

Computational Materials Research

High temperature thermoplastic polyimide polymers are incorporated in engineering structures in the form of matrix materials in advanced fiber composites and adhesives in bonded joints. Developing analytical tools to predict long term performance and screen for final materials selection for polymers is the impetus for intensive studies at NASA and major industry based airframe developers. These fiber-reinforced polymeric composites (FRPCs) combine high strength with lightweight. In addition, they offer corrosion and fatigue resistance, a reduction in parts count, and new possibilities for control through aeroelastic tailoring and "smart" structures containing fully-integrated sensors and actuators. However, large-scale acceptance and use of polymer composites has historically been extremely slow. Reasons for this include a lack of familiarity of designers with the materials; the need for new tooling and new inspection and repair infrastructures; and high raw materials and fabrication costs.

Veazie, David R.↗

Application of Emulsified Zero-Valent Iron to Marine Environments

Contamination of marine waters and sediments with heavy metals and dense non-aqueous phase liquids (DNAPLs) including chlorinated solvents, pesticides and PCBs pose ecological and human health risks through the contaminant's potential bioaccumulation in fish, shellfish and avian populations. The contaminants enter marine environments through improper disposal techniques and storm water run-off. Current remediation technologies for application to marine environments include costly dredging and off-site treatment of the contaminated media. Emulsified zero-valent iron (EZVI) has been proven to effectively degrade dissolved-phase and DNAPL-phase contaminants in freshwater environments on both the laboratory and field-scale level. However, the application to marine environments is only just being explored. This paper discusses the potential use of EZVI in brackish and saltwater environments, with supporting laboratory data detailed. Laboratory studies were performed in 2005 to establish the effectiveness of EZVI to degrade trichloroethylene (TCE) in saltwater. Headspace vials were setup to determine the kinetic rate of TCE degradation using EZVI in seawater. The reaction vials were analyzed by Gas Chromatographic/Flame Ionization Detection (GC/FID) for ethene production after a 48 day period using a GC/FID Purge and Trap system. Analytical results showed that EZVI was very effective at degrading TCE. The reaction by-products (ethene, acetylene and ethane) were produced at 71% of the rate in seawater as in the fresh water controls. Additionally, iron within the EZVI particles was protected from oxidation of the corrosive seawater, allowing EZVI to perform in an environment where zero-valent iron alone could not compete. Laboratory studies were also performed to establish the effectiveness of emulsified zero-valent metal (EZVM) to remove dissolved-phase cadmium and lead found in seawater. EZVM is comprised of a combination of magnesium and iron metal surrounded by the same oil/surfactant membrane used in EZVI. The removal of cadmium and lead from a seawater matrix is a unique challenge. It requires a system that is resistant to the corrosive nature of seawater while removing specific ions that are in a relatively low concentration compared to naturally occurring seawater salts. Laboratory studies conducted show greater than 99% removal of lead and 96% removal of cadmium from a seawater solution spiked at 5 mg/L that was treated with an Emulsified Zero-Valent Metal (EZVM). The cadmium and lead are removed from the solution as they transport across the emulsion membrane and plate out onto the zero-valent metal surface.

Brooks, Kathleen B.↗

UPT scenarios: Implications for system reliability

The objective of this project was to examine the corrosion resistance of 316L stainless steel in several urine pre-treat solutions. Four solutions were examined: untreated urine (control); urine pretreated with oxone (potassium peroxymonosulfate sulfate); urine pretreated with sodium hypochlorite (NaOCl); and urine pretreated with ozone (O3). In accordance with current procedures, all solutions but the control were acidified to a pH of 2.5 using sulfuric acid--this suppresses the generation of ammonia in the solutions and is intended to limit microbial growth. Welded and unwelded coupons were exposed to each solution. In addition, Titanium coupons (welded and unwelded) were exposed to biologically active environmental control and life support system (ECLSS) water. Microbial attachment and biofilm growth were monitored. Ozone was examined as a biocide/oxidizer/corrosion preventative (simultaneous addition) and as a remediation method (added one week after exposure). In an unrelated effort, HP 9-4-30 coupons were exposed to biologically active solutions. Corrosion rates for welded and unwelded samples were determined--results were correlated to the ongoing HP 9-4-30 weldment stress corrosion study.

Walsh, Daniel W.↗

Formation of ferrihydrite and associated iron corrosion products in permeable reactive barriers of zero-valent iron

Ferrihydrite, which is known to form in the presence of oxygen and to be stabilized by the adsorption of Si, PO4 and SO4, is ubiquitous in the fine-grained fractions of permeable reactive barrier (PRB) samples from the U.S. Coast Guard Support Center (Elizabeth City, NC) and the Denver Federal Center (Lakewood, CO) studied by high-resolution transmission electron microscopy and selected area electron diffraction. The concurrent energy-dispersive X-ray data indicate a strong association between ferrihydrite and metals such as Si, Ca, and Cr. Magnetite, green rust 1, aragonite, calcite, mackinawite, greigite and lepidocrocite were also present, indicative of a geochemical environment that is temporally and spatially heterogeneous. Whereas magnetite, which is known to form due to anaerobic Fe0 corrosion, passivates the Fe0 surface, ferrihydrite precipitation occurs away from the immediate Fe0 surface, forming small (<0.1 microm) discrete clusters. Consequently, Fe0-PRBs may remain effective for a longer period of time in slightly oxidized groundwater systems where ferrihydrite formation occurs compared to oxygen-depleted systems where magnetite passivation occurs. The ubiquitous presence of ferrihydrite suggests that the use of Fe0-PRBs may be extended to applications that require contaminant adsorption rather than, or in addition to, redox-promoted contaminant degradation.

Metals/chemistry↗

Antimicrobials for Water Systems in Manned Spaceflight - Past, Present, and Future Applications and Challenges

The use of antimicrobials to control microbiological growth in manned spaceflight water-based systems has and will continue to have a unique set of challenges and needs. The challenges are varied, and include antimicrobial effectiveness, crew health and safety, materials compatibility, optimal system functionality, antimicrobial shelf life, means to monitor antimicrobial concentration, and means to re-introduce biocides periodically in the case of depletion. Needs vary from application to application, and include control of pathogens for crew health, control of biofilm formation for optimal system functionality, inhibition and prevention of microbiologically influenced corrosion, optimization of wetted metallic material life, and general living quarter and consumable aesthetics with respect to odor and taste. This paper outlines and discusses the various antimicrobials used in prior and current manned spaceflight water-based applications with focus on pros, cons and lessons learned. Design factors such as minimum inhibitory concentration, minimum lethal concentration, required circulated concentrations, materials selection, means to introduce, means to monitor real-time, and concentration maintenance are discussed. The challenges associated with longer term missions, as well as long-term system dormancy as envisioned for exploration missions, lunar habitats, and a manned Mars mission are outlined with respect to anticipated needs and potential design solutions.

potable water↗

Novel Environmental Barrier Coatings for the Protection of SiC Components

Greater gas turbine engine efficiency is a major goal in aeronautics research often pursued through increased engine operating temperatures. However, it is necessary to replace the current hot-stage alloy components with more thermally robust parts, such as Silicon-based ceramics and composites. Unfortunately, these materials are still susceptible to the effects of oxidation, water vapor, and (Calcium-Magnesium-Alumino-Silicate) CMAS interaction, among other issues at high temperature. To mitigate these effects, environmental barrier coating (EBC) materials are employed to help control the rate of degradation to the underlying composite, but must also survive the corrosive environment. The current study explores new design space in Mg-based EBC materials with respect to microstructure, high temperature phase stability, volatilization in water vapor, as well as structure-property relationships at high temperature.

Kowalski, Benjamin A.↗

Status of Understanding for Bearing Materials

The structural materials and potential failure modes for high technology aircraft gas turbine bearings are reviewed. Among the failure modes discussed for iron-base through-hardened bearing materials are fatigue, surface distress, and corrosion. It is shown that the sub-surface initiated rolling-contact fatigue failure mode is reasonably well understood and in most cases can be controlled by proper material selection and design. Current bearing materials provide long life and high reliability in existing applications. A new generation of materials are being developed which will provide improved fracture toughness, better corrosion resistance, and a further extension of bearing fatigue life. Bearing problems due to surface distress, caused by a variety of surface and near surface anomalies, are less well understood. This area will require the implementation of an interdisciplinary effort to improve the level of understanding of metallic surface-lubricant reactions and interactions.

E N Bamberger↗

The ecology of microorganisms in a small closed system: Potential benefits and problems for space station

The inevitble presence on the space station of microorganisms associated with crew members and their environment will have the potential for both benefits and a range of problems including illness and corrosion of materials. This report reviews the literature presenting information about microorganisms pertinent to Environmental Control and Life Support (ECLS) on the space station. The perspective of the report is ecological, viewing the space station as an ecosystem in which biological relationships are affected by factors such as zero gravity and by closure of a small volume of space. Potential sites and activities of microorganisms on the space station and their environmental limits, microbial standards for the space station, monitoring and control methods, effects of space factors on microorganisms, and extraterrestrial contamination are discussed.

Rodgers, E. B.↗

QuEST: Qualifying Environmentally Sustainable Technologies, Volume 5

This edition of the QuEST newsletter contains brief articles that discuss the NASA Technology Evaluation for Environmental Risk Mitigation (TEERM) program, and the importance of collaboration, efforts in materials management and substitution for coatings for launch structures, Low volatile organic compound (VOC) Coatings Field Testing, Non-Chrome Coating Systems, Life Cycle Corrosion Testing, Lead-Free Electronics Testing and Corn Based Depainting and efforts in Pollution Control in the area of Hypergolic Propellant Destruction Evaluation, efforts in development of alternative energy in particular Hydrogen Sensors, Energy and Water Management, and efforts in remediation in the removal of Polychlorinated Biphenyl (PCB) contamination

Lewis, Pattie↗