At least 199 records · Page 11

Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The dynamics and control of fluctuating pressure loads in the reattachment region of a supersonic free shear layer

The primary aim is to investigate the mechanisms which cause the unsteady wall-pressure fluctuations in shock wave turbulent shear layer interactions. The secondary aim is to find means to reduce the magnitude of the fluctuating pressure loads by controlling the unsteady shock motion. The particular flow proposed for study is the unsteady shock wave interaction formed in the reattachment zone of a separated supersonic flow. Similar flows are encountered in many practical situations, and they are associated with high levels of fluctuating wall pressure. Wall pressure fluctuations were measured in the reattachment region of the supersonic free shear layer. The free shear layer was formed by the separation of a Mach 2.9 turbulent boundary layer from a backward facing step. Reattachment occurred on a 20 deg ramp. By adjusting the position of the ramp, the base pressure was set equal to the freestream pressure, and the free shear layer formed in the absence of a separation shock. An array of flush-mounted, miniature, high-frequency pressure transducers was used to make multichannel measurements of the fluctuating wall pressure in the vicinity of the reattachment region. Contrary to previous observations of this flow, the reattachment region was found to be highly unsteady, and the pressure fluctuations were found to be significant. The overall behavior of the wall pressure loading is similar in scale and magnitude to the unsteadiness of the wall pressure field in compression ramp flows at the same Mach number. Rayleigh scattering was used to visualize the instantaneous shock structure in the streamwise and spanwise direction. Spanwise wrinkles on the order of half the boundary layer thickness were observed.

Smits, A. J.↗

High temperature tension-compression fatigue behavior of a tungsten copper composite

The high temperature fatigue of a (O)12 tungsten fiber reinforced copper matrix composite was investigated. Specimens having fiber volume percentages of 10 and 36 were fatigued under fully-reversed, strain-controlled conditions at both 260 and 560 C. The fatigue life was found to be independent of fiber volume fraction because fatigue damage preferentially occurred in the matrix. Also, the composite fatigue lives were shorter at 560 C as compared to 260 C due to changes in mode of matrix failure. On a total strain basis, the fatigue life of the composite at 560 C was the same as the life of unreinforced copper, indicating that the presence of the fibers did not degrade the fatigue resistance of the copper matrix in this composite system. Comparison of strain-controlled fatigue data to previously-generated load-controlled data revealed that the strain-controlled fatigue lives were longer because of mean strain and mean stress effects.

Verrilli, Michael J.↗

Development of a microprocessor controller for stand-alone photovoltaic power systems

A controller for stand-alone photovoltaic systems has been developed using a low power CMOS microprocessor. It performs battery state of charge estimation, array control, load management, instrumentation, automatic testing, and communications functions. Array control options are sequential subarray switching and maximum power control. A calculator keypad and LCD display provides manual control, fault diagnosis and digital multimeter functions. An RS-232 port provides data logging or remote control capability. A prototype 5 kW unit has been built and tested successfully. The controller is expected to be useful in village photovoltaic power systems, large solar water pumping installations, and other battery management applications.

Millner, A. R.↗

Multiple-function multi-input/multi-output digital control and on-line analysis

The design and capabilities of two digital controller systems for aeroelastic wind-tunnel models are described. The first allowed control of flutter while performing roll maneuvers with wing load control as well as coordinating the acquisition, storage, and transfer of data for on-line analysis. This system, which employs several digital signal multi-processor (DSP) boards programmed in high-level software languages, is housed in a SUN Workstation environment. A second DCS provides a measure of wind-tunnel safety by functioning as a trip system during testing in the case of high model dynamic response or in case the first DCS fails. The second DCS uses National Instruments LabVIEW Software and Hardware within a Macintosh environment.

Hoadley, Sherwood T.↗

Lighting controls: not just for lighting anymore!

For the last few years, networked lighting controls (NLCs) have promised significant energy savings beyond what is achieved through a basic LED retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems. Integrating NLC with control of heating, ventilation and air conditioning (HVAC), plug load control, space utilization, and grid services all enhance the value of your NLC investment. There are already a few NLC products on the market that are capable of providing these enhanced benefits. Manufacturers and entrepreneurs are working hard to expand the impact of these products. But does system interoperability work? Can it be deployed at scale? Slipstream, NEEA and Pacific Northwest National Laboratory (PNNL) have all been attempting to answer these questions in recent pilot projects and describe the outcomes in this paper.

Hackel, Scott↗

Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression, Flight-Test Performance

The problem of control command and maneuver induced structural loads is an important aspect of any control system design. The aircraft structure and the control architecture must be designed to achieve desired piloted control responses while limiting the imparted structural loads. The classical approach is to utilize high structural margins, restrict control surface commands to a limited set of analyzed combinations, and train pilots to follow procedural maneuvering limitations. With recent advances in structural sensing and the continued desire to improve safety and vehicle fuel efficiency, it is both possible and desirable to develop control architectures that enable lighter vehicle weights while maintaining and improving protection against structural damage. An optimal control technique has been explored and shown to achieve desirable vehicle control performance while limiting sensed structural loads to specified values. This technique has been implemented and flown on the National Aeronautics and Space Administration Full-scale Advanced Systems Testbed aircraft. The flight tests illustrate that the approach achieves the desired performance and show promising potential benefits. The flights also uncovered some important issues that will need to be addressed for production application.

cFOSS↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive Margin Assessment of the ASME Section III, Division 5, Class A Primary Load Design Rules

This report provides a comprehensive margin assessment of the ASME Section III, Division 5, Subsection HB, Subpart B rules for the design of high temperature reactor components against load controlled stress limits. These rules, often called the Code primary load design rules, provide protection against creep rupture and plastic collapse under steady conditions. The method adopted here is to compare the deterministic ASME design life, according to the primary load design rules, against the expected, statistical service life of the component, considering creep rupture as the relevant failure mode. The report provides the design margin of the ASME rules in terms of the probability of premature failure -- the probability that the component fails in service before reaching the ASME design life. To complete this assessment, the report describes the development of a statistical creep life assessment procedure accounting for variations in the component loading, material creep rate, and the material rupture time. This includes a novel method for correlating creep rupture data using a Gaussian process accounting for heat-to-heat variation in the Larson-Miller time-temperature parameter. The report applies the complete margin assessment process to quantify the design margin inherent in the ASME primary load design rules as a function of temperature for relevant component geometries and materials. The overall conclusion is that the ASME rules are conservative, providing designs with very small probability of premature failure, but some optimization of the Code design rules is possible to provide a more uniform design margin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stochastic Pricing Game for Aggregated Demand Response Considering Comfort Level

In recent years, demand response (DR) has been explored as a fundamental strategy for demand-side management due to its advantages in mediating intermittency of renewable energy generation, load shifting, etc. To engage customers in DR programs, several deterministic price-based DR strategies have been developed and implemented. However, the stochastic weather conditions and occupants' consumption behaviors often make the deterministic solution less robust to uncertainties. In this paper, with the consideration of the uncertainties, a stochastic Stackelberg game is proposed to model the price-demand negotiation between a distributed system operator and load aggregators, where the virtual battery constraints are extracted from the building thermostatically controlled loads (TCLs)‘ characteristics to guarantee comfortable TCLs' levels. Following the negotiation, a priority-based control method is used to allocate the optimal aggregated power DR profile at the building level and track the power signal. Several groups of experiments have demonstrated the effectiveness and robustness of the stochastic solutions.

Chen, Yang↗

Citraturic response to oral citric acid load

It is possible that some orally administered citrate may appear in urine by escaping oxidation in vivo. To determine whether this mechanism contributes to the citraturic response to potassium citrate, we measured serum and urinary citrate for 4 hours after a single oral load of citric acid (40 mEq.) in 6 normal subjects. Since citric acid does not alter acid-base balance, the effect of absorbed citrate could be isolated from that of alkali load. Serum citrate concentration increased significantly (p less than 0.05) 30 minutes after a single oral dose of citric acid and remained significantly elevated for 3 hours after citric acid load. Commensurate with this change, urinary citrate excretion peaked at 2 hours and gradually decreased during the next 2 hours after citric acid load. In contrast, serum and urinary citrate remained unaltered following the control load (no drug). Differences of the citratemic and citraturic effects between phases were significant (p less than 0.05) at 2 and 3 hours. Urinary pH, carbon dioxide pressure, bicarbonate, total carbon dioxide and ammonium did not change at any time after citric acid load, and did not differ between the 2 phases. No significant difference was noted in serum electrolytes, arterialized venous pH and carbon dioxide pressure at any time after citric acid load and between the 2 phases. Thus, the citraturic and citratemic effects of oral citric acid are largely accountable by provision of absorbed citrate, which has escaped in vivo degradation.

Non-NASA Center↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

An improved CAMRAD model for aeroelastic stability analysis of the XV-15 with advanced technology blades

In pursuit of higher performance, the XV-15 Tiltrotor Research Aircraft was modified by the installation of new composite rotor blades. Initial flights with the Advanced Technology Blades (ATB's) revealed excessive rotor control loads that were traced to a dynamic mismatch between the blades and the aircraft control system. The analytical models of both the blades and the mechanical controls were extensively revised for use by the CAMRAD computer program to better predict aeroelastic stability and loads. This report documents the most important revisions and discusses their effects on aeroelastic stability predictions for airplane-mode flight. The ATB's may be flown in several different configurations for research, including changes in blade sweep and tip twist. The effects on stability of 1 deg and 0 deg sweep are illustrated, as are those of twisted and zero-twist tips. This report also discusses the effects of stiffening the rotor control system, which was done by locking out lateral cyclic swashplate motion with shims.

Acree, C. W., Jr.↗

Al–W gradient density materials—Processing and dynamic ramp compression

Materials with high-density gradients are desired for controlling loading paths in dynamic compression, important for studying material properties in extreme conditions and inertial confinement fusion. The large density difference between Al and W makes them ideal choices for producing gradient density materials, but their extremely different melting temperatures make them challenging to fabricate simultaneously. We report a method for producing Al–W porosity-free materials with a fourfold increase in density (2.7–11 g/cm 3 ) across the composition range, from Al-rich to W-rich, without intermetallic phase formation. This was achieved by understanding the aluminum-dominated densification behavior and examining the influence of pressure and temperature on the densification of Al–W composites. Dynamic compression experiments conducted with the Al–W gradient density material produced shock ramp compressions as expected based on the designed composition, and the performed hydrodynamics simulations showed excellent agreement with experimental results. The results demonstrate that current activated pressure-assisted densification allows for the easy and rapid fabrication of gradient density materials with significant density gradients and tailored compositions, facilitating precise control of the loading paths. These materials have the potential to create customized pressure drives for advancing the fields of material science in extreme environments and dynamic compression.

Alloys↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Controller Developed for the Free-Piston Stirling Convertor

A free-piston Stirling power convertor is being considered as an advanced power-conversion technology for future NASA deep-space missions requiring long-life radioisotope power systems. The NASA Glenn Research Center has identified key areas where advanced technologies can enhance the capability of Stirling energy-conversion systems. One of these is power electronic controls. Current power-conversion technology for Glenn-tested Stirling systems consists of an engine-driven linear alternator generating an alternating-current voltage controlled by a tuning-capacitor-based alternating-current peak voltage load controller. The tuning capacitor keeps the internal alternator electromotive force (EMF) in phase with its respective current (i.e., passive power factor correction). The alternator EMF is related to the piston velocity, which must be kept in phase with the alternator current in order to achieve stable operation. This tuning capacitor, which adds volume and mass to the overall Stirling convertor, can be eliminated if the controller can actively drive the magnitude and phase of the alternator current.

Gerber, Scott S.↗

Load Mitigating Feedback Control of WECs

This report outlines the development of load-mitigating feedback control for wave energy converters. A simple, self-tuning multi-objective controller is demonstrated in simulation for a 3-DOF (surge, heave, pitch) point absorber. In previous work, the proposed control architecture has been shown to be effective in experiment for a variety of device archetypes for the single objective of the maximization of electrical power capture: here this architecture is extended to reduce device loading as well. In particular, PTO actuation forces and the minimization of fatigue damage (determined from the sum of wave-exerted and PTO forces) are considered as additional objectives for the self-tuning controller. This controller is demonstrated for two similar, but distinct systems: one described by the identified linear models from physical testing of the WaveBot device, and another based upon a WEC-Sim simulation that expands upon boundary element method data from the WaveBot device. In both cases, because the power surface is consistently fairly flat in the vicinity of control parameters that maximize power capture in contrasting sea-states, it is found to be generally possible to mitigate either fatigue damage or PTO load. However, PTO load is found to conflict with fatigue damage in some sea-states, limiting the efficacy of control objectives that attempt to mitigate both simultaneously. Additionally, coupling between the surge and pitch DOFs also limits the extent to which fatigue damage can be mitigated for both DOFs in some sea-states. Because control objectives can be considered a function of the sea-state (e.g., load mitigation may not be a concern until the sea is sufficiently large) a simple transition strategy is proposed and demonstrated. This transition strategy is found to be effective with some caveats: firstly, it cannot circumvent the aforementioned objective contradictions. Secondly, this objective transition is too slow to act as a system constraint, and objective thresholds must thus be considered quite conservatively. Improvement of the adjustment strategy is demonstrated through the addition of an integral term. Selection of well-performing transition parameters can be a function of sea-state. While a simple selection procedure is proposed, it is non-optimal, and a more robust selection procedure is suggested for future work.

16 TIDAL AND WAVE POWER↗

Integrating Electric Vehicle Charging Infrastructure into Commercial Buildings and Mixed-Use Communities: Design, Modeling, and Control Optimization Opportunities: Preprint

This paper discusses modeling and field studies of controlled EV charging that have been performed with the goal of minimizing requirements for infrastructure upgrades, minimizing building peak demand charges, and maximizing the use of on-site generation. We present a large-scale workplace charging pilot of a demand-controlled scheduled EV charging system with over 250 active daily commuters, successfully demonstrating management of aggregate charging power to avoid new infrastructure investments, mitigate peak demand charges, and provide cost-effective workplace charging to users. In addition to understanding opportunities for demand management, integrating these controllable loads into the energy modeling process for new buildings will also be necessary. This paper then presents an example energy modeling process that evaluates the potential effects of EV charging on building load profiles and infrastructure requirements for a mixed-use community. Finally, we discuss an illustration of how EV charging can be controlled to be synergistic with other building loads and distributed generation.

buildings↗