Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservation of intensity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pathway for decarbonizing residential building operations in the US and China beyond the mid-century

With global carbon budget targets looming, residential buildings in top economies must become carbon neutral as soon as possible to reserve more emission space for emerging carbon-emitting economies. This study is the first to compare the operational decarbonization process of China’s and the United States (US) residential buildings from 2000 to 2060 by combining the end-use emission model with the decomposing structural decomposition (DSD) method and Monte Carlo simulation. The results show that from 2001 to 2020 China decarbonized 1544 mega-tons of carbon dioxide (MtCO 2 ) and the US decarbonized 1848 MtCO 2 . In the business-as-usual scenario, China will hit its emission peak in 2031 (±3) with 934 (±61) MtCO 2 , while the US will maintain a lock-in level of 736 (±133) MtCO 2 since the 2030s. In the decarbonization scenario, operational carbon neutrality for residential buildings in 2060 is promoted by an increase in clean power generation proportion, building-integrated power generation level, building electrification level, and a reduction in end-use energy intensity, which will contribute 34.4 %, 21.4 %, 14.3 %, and 29.9 % in China and 32.9 %, 33.1 %, 8.2 %, and 25.8 % in the US, respectively. Especially, building-integrated power generation in China only costs about 40 % of what it costs in the US. Besides, high-decarbonization strategies for residential building operations are proposed as references for governments to formulate targeted climate policies. Overall, this study offers data benchmarks for buildings’ carbon neutrality of top economies to further promote synergistic carbon neutrality with the buildings of emerging economies in the age of Post COP27.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially and Temporally Detailed Water and Carbon Footprints of U.S. Electricity Generation and Use

Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The current state of the industrial energy assessment and its impacts on the manufacturing industry

Energy-intensive manufacturing is the greatest contributor to the U.S. industrial energy consumption today. Globally, manufacturing facilities are being directed to reduce their energy consumption to prepare for a sustainable future. Industrial energy assessment plays a crucial role in helping facilities meet their energy efficiency goals by encouraging the implementation of cost-effective, energy-saving recommendations to the existing equipment and processes. Across the world, programs such as the U.S. Department of Energy (DOE) sponsored Industrial Assessment Centers (IACs) (operational across several states in the U.S. for over four decades), are transforming the future of industrial energy consumption by offering free industrial energy assessments to qualifying facilities. In this review paper, the industrial energy assessment approach and practices are comprehensively reviewed with focus on popular recommendations, procedures, and the current practices of the industrial energy assessment program. Specifically, opportunities for improvement in the most energy-intensive manufacturing processes are examined, concentrating on the energy savings and other non-energy benefits of each of these measures, such as cost savings and emissions reduction. Furthermore, this paper also reviews how these energy-saving opportunities are procedurally evaluated and how factors, such as level and cost of assessments, and assessment metrics, are currently defining industrial energy assessment. In final considerations, existing research on energy management, decarbonization through electrification, and renewable energy in industry is reviewed and discussed, and how these advancements will shape the future of industrial energy assessment is addressed through forward-looking lenses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oak Ridge National Laboratory Technical Input for the Nuclear Regulatory Commission Review of the 2017 Edition of ASME Section III, Division 5, ‘High Temperature Reactors’

To assist the Nuclear Regulatory Commission in its decision making on endorsement of the American Society for Mechanical Engineers Boiler and Pressure Vessel Code Section III, Division 5 (2017 Edition) for development of advanced non-light water reactors, the following Division 5 portions were reviewed: Article HBB-2000 Material; Article HCB-2000 Material; Article HGB-2000 Material; Mandatory Appendix HBB-I-14 Tables and Figures; and, Nonmandatory Appendix HBB-U Guidelines for Restricted Material Specifications to Improve Performance in Certain Service Applications. In addition to the 2017 Edition, the same parts of the 2019 Edition have also been reviewed as indicated in various sections of the report. This review was conducted by a collaboration of national laboratory and private sector participants with significant industrial experience, including some heavy lifting and deep diving from Clarus Consulting, LLC., all intended to achieve an objective, independent, and practical perspective. The report provides recommendations, descriptions of the evaluation methods, and the source references for the data used. To build confidence required for endorsement of the Code, this review was conducted as a verification and validation of the above Code contents. The objective of verification is to ensure that the Code is free of error – direct or implied; contains the information needed for its use, including proper coverage of the Code-specified materials for the intended application, and completeness and adequacy of references to other portions of the Code. The objective of validation is to authenticate that the Code tabulations and graphs represent design inputs consistent with what are determined using rules and methods specified by the Code. The authentication process used data that were assembled and/or generated independent of Code development, while the methods of analysis followed Code-specified methods where appropriate. The designated portions for this review cover the five alloys codified for high temperature reactor applications in Division 5, i.e. 316 SS, 304 SS, 800H, 2¼Cr-1Mo, and 9Cr-1Mo-V, regarding their general requirements, permitted specifications and design stress intensity values for pressure-retaining applications, deterioration in service, fatigue acceptance test, permissible weld materials, tensile and yield strength, expected minimum stress-to-rupture values (including for Alloy 718), weld stress rupture factors, permissible materials for bolting use, and restricted specifications in certain service applications. Additionally, stress intensity values for bolting materials including 316 SS, 304 SS and alloy 718 were reviewed. Analysis and discussion are also provided on contents outside of these designated Code portions where it was deemed relevant and necessary to develop a technically sound understanding of issues relating to the designated portions. Due to unavailability of sufficient test data on welds during the review period, the weld stress rupture factors in Tables HBB-I-10.14A to E, which cover a total of ten tables for the five alloys welded with twenty-eight different weld metals (some with similar properties), have been deferred to a future review effort. The review identified mainly two types of issues. The first type includes instances where the Code is found factually incomplete or incorrect, such as obsolete materials specifications listings, missing tabulation of stresses for bolting. Changes to the Code are recommended in these cases. The second type of issue includes instances where the Code tabulations and graphs are found to be less conservative than the review analysis results. In these cases, recommendations are made for further review and consideration where the difference in conservatism exceeds 10%, which is our threshold for questioning technical adequacy, meriting a risk assessment by the Nuclear Regulatory Commission and/or reactor designers. It is noted that this effort has been executed using all available data and established methods of analysis, including methods and criteria specified and used by the Code. As such, the findings that are presented in quantitative detail, in a format for convenient comparison with the Code, and with identification of where further review is recommended, should provide a sound technical basis for decisions about quantifying the implications of the reduced design margins and technical adequacy/inadequacy to form a basis for conditioning specific Code tabulation values on endorsement. Recommendations for specific changes to the Code, however, entail design conservatism considerations beyond the scope of this review effort, and are not made in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Engine Valve Materials for Next Generation Higher Efficiency Engines

The growing demand to increase the performance and efficiency of light-, medium-, and heavy-duty engines continues to drive increases in combustion intensities and cylinder pressures, which result in higher exhaust gas temperatures. Thus, there is a critical need for new materials that can meet the performance and cost targets for components such as exhaust valves which are exposed to these higher exhaust gas temperatures. Oak Ridge National Laboratory (ORNL) has developed several lower-cost, high-strength alloys that have the potential to be adopted into intake and/or exhaust valves in the next generation, high-efficiency engines and other high temperature applications. These alloys are covered by two issued patents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UHT-CAMANCHE: Ultra-High Temperature Ceramic Additively Manufactured Compact Heat Exchangers

The conceptual basis for this project is the convergence of advanced ultra-high temperature ceramic materials and additive manufacturing technologies to produce compact ceramic heat exchangers with complex internal flow path geometries. Task areas were broadly divided into materials and manufacturing development, heat exchanger design, component testing, and techno-economic analysis. Technical challenges included the design and commissioning of new test facilities, improving feature resolution and deposition rate of ceramic additive manufacturing techniques, establishing process-structure-property relationships in additively manufactured ultra-high temperature ceramics, and assessing high temperature materials compatibility in CO 2 environments. The primary candidate material evaluated in this work is a composite comprising zirconium diboride (ZrB2) with 30 vol. % silicon carbide (SiC) which was selected based on its desirable combination of high temperature mechanical properties, high thermal and electrical conductivities, and oxidation resistance. High solids loaded ZrB2-SiC pastes suitable for extrusion-based additive manufacturing were developed for the first time as part of this work. Materials compatibility studies indicate this material oxidizes in CO 2 to form a protective borosilicate scale which transforms to pure silica above 1000°C. Parts made by additive manufacturing displayed enlarged grain sizes produced by pressureless sintering as compared to hot-press sintering. Increases in microstructural coarseness have outsized effect on oxidation performance up to 1400°C due to incomplete oxidation of coarse large diameter SiC particles resulting in lower amounts of silica that apparently inhibit protective scale formation. Additive manufacturing as a forming technique did not appear to significantly affect thermal conductivity, hardness, or elastic modulus, though flexural strength was reduced by half or more as compared to traditionally hot-pressed materials. This effect was attributed to the presence of strength-limiting flaws (ca. 40 microns in size) originating from extrudate inhomogeneities that could potentially be eliminated with further process improvements. Attempts to attain economies of scale for production of multi-kilowatt scale heat exchangers by ceramic additive manufacturing proved difficult. Lack of automation and a modest extrusion rate while retaining fine feature resolution made the overall process labor intensive and limited experimental throughput. A number of full-scale components were taken through post-process heat treatments including drying, binder burnout, and sintering; however, none survived without significant flaws or cracks. Therefore, no operational data from a newly installed heat exchanger test loop were able to be obtained during the performance period. Continued research and development is recommended to improve economic feasibility of ceramic additive manufacturing by standardizing the use of advanced sensors, artificial intelligence, and automation tools to reduce associated labor costs and accelerate production rates. The materials and manufacturing techniques demonstrated in this work are likely to find applications in defense and energy applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response in Industrial Facilities: Peak Electric Demand

The US Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) is a voluntary energy efficiency leadership initiative for US manufacturers and water/wastewater entities. The program encourages organizations to commit to reducing the energy intensity of their US operations over a 10-year period, typically by 25%. Companies joining Better Plants are recognized by DOE for their leadership in implementing energy efficiency practices and for reducing their energy intensity. Better Plants Partners are assigned to a Technical Account Manager, who can help companies establish energy intensity baselines, develop energy management plans, and identify key resources and incentives from DOE, other federal agencies, states, utilities, and other organizations that can enable them to reach their goals. Better Plants Partners are expected to report their progress to DOE once a year. This involves establishing an energy intensity baseline upon joining the program and then tracking their progress over time. Demand Response in Industrial Facilities: Peak Electrical Demand is intended to help companies understand peak demand response programs offering by their local utility. Manufacturing industries can learn about time-varying rates and smart technologies they can use to help them reduce their energy bills. This guidance document is applicable to companies participating at either the program or challenge level. Although this guide is intended primarily to assist companies participating in Better Plants, the methodologies and guidance within the document are applicable to any organization interested in understanding peak demand response programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sand-Based Thermal Storage for Building Heating Applications: A District Energy Case Study

Buildings account for 40% of global energy consumption and contribute to 30% of global carbon emissions. As energy from renewable sources increases in availability and building designers push for increased electrification, thermal energy storage (TES) systems will play a crucial role in extending the usable time horizon of renewable energy. While water, molten salt, and phase change materials are typically used for building TES heating applications, silica-sand has emerged as an alternative medium for concentrated solar power applications due to its low cost, wide availability, and comparable system efficiency. This paper proposes a new silica-sand particle-based TES system for building heating applications. In this work, a novel steam plant for district heating applications is first designed to utilize silica-sand TES, which can be used for different district energy systems. To demonstrate the silica-sand TES plant performance, the design is modelled in Modelica based on a case study on the University of Colorado Boulder’s campus. The simulation results show that the sand TES plant is more costly to operate than a gas-boiler based plant due to the low cost of natural gas, while the site EUI and carbon intensity can be improved. This novel system shows initial promise as a low-carbon alternative to conventional natural gas steam boilers but will require further modelling and follow-up research to improve its energy efficiency. An eventual rise in natural gas prices, and reduction of electricity prices, could improve the economic viability of this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Efficient screening of rare large pit anomalies on polished surfaces using a minimalist sampling scheme

Lawrence Livermore National Laboratory (LLNL) has made significant strides in generating clean energy through its inertial confinement fusion (ICF) experiments. These experiments rely on high-density carbon (HDC) coated shells to encapsulate the fusion fuel. The success of these experiments is heavily dependent on the surface quality of these shells, as even minor imperfections, such as deep pits, can negatively impact fusion yield. Ensuring the required smoothness involves an extensive surface-finishing process that spans approximately 20 stages, making it both time-intensive and resource-demanding. A critical challenge in this process is the need for high-resolution scans to detect rare deep pits, which can be costly and impractical if performed on every shell. This highlights the necessity of developing more efficient scanning methods to optimize time and cost without compromising accuracy. To address these challenges, we introduce a novel approach that employs the multivariate Dvoretzky–Kiefer–Wolfowitz (DKW) inequality to provide a probabilistic upper bound on the error in estimating pit distribution characteristics via a Kernel Density Estimator (KDE). This error bound enables efficient and reliable estimation of pit distribution characteristics at a specified statistical confidence level using a minimal number of surface scans. The integrated DKW-KDE approach was validated through surface-finishing experiments across two batches of HDC-coated shells, demonstrating consistent and robust performance across multiple stages of the surface-finishing experiments. The validation studies suggest that the integrated DKW-KDE approach achieves comparable accuracy in estimating the risk of deleterious large pits with six scans, thus conserving time and resources. Further evaluations show that performance remains consistent across batches and over multiple polishing stages. In conclusion, based on these findings, one can leverage the minimal-scan insights to strategically improve the bottleneck inspection process, thus enhancing the productivity and quality of shell polishing and similar challenging manufacturing processes.

Inertial confinement fusion↗