Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conditional expectations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Non-unimodal and non-concave relationships in the network Macroscopic Fundamental Diagram caused by hierarchical streets

Unimodal, concave relationships between average network productivity and accumulation or density aggregated across spatially compact regions of urban networks—so called network Macroscopic Fundamental Diagrams (MFDs)—have recently been shown to exist on homogeneous street networks. When present, MFD relationships facilitate the modeling of traffic congestion at a regional level and have led to the development of various regional traffic control strategies. However, real street networks are not homogeneous—they generally have a hierarchical structure where some streets (e.g., arterials) promote higher mobility than others (e.g., local roads). Here, this paper examines how the presence of hierarchical roadway structures may potentially cause non-unimodal patterns in a network's MFD. These are observed using three types of tools: analytical models of simple network structures, simulations of various idealized roadway networks, and empirical data. The impacts of street hierarchy depend on how vehicles use different roadway types to move within the network; i.e., their routing strategy. The findings suggest that the presence of roadway hierarchies may lead to MFDs that have non-unimodal or non-concave patterns on the free-flow branch when vehicles route themselves according to user equilibrium principles, which is closest to what would be observed in realistic situations. Such patterns are contrary to what is traditionally assumed in most MFD-based modeling frameworks. However, the unimodal and concave MFD should be expected under system optimal routing conditions that maximize network productivity for a given traffic state.

42 ENGINEERING↗

Divertor heat flux challenge and mitigation in SPARC

Owing to its high magnetic field, high power, and compact size, the SPARC experiment will operate with divertor conditions at or above those expected in reactor-class tokamaks. Power exhaust at this scale remains one of the key challenges for practical fusion energy. Based on empirical scalings, the peak unmitigated divertor parallel heat flux is projected to be greater than 10 GW m -2 . This is nearly an order of magnitude higher than has been demonstrated to date. Furthermore, the divertor parallel Edge-Localized Mode (ELM) energy fluence projections (~11–34 MJ m -2 ) are comparable with those for ITER. However, the relatively short pulse length (~25 s pulse, with a ~10 s flat top) provides the opportunity to consider mitigation schemes unsuited to long-pulse devices including ITER and reactors. The baseline scenario for SPARC employs a ~1 Hz strike point sweep to spread the heat flux over a large divertor target surface area to keep tile surface temperatures within tolerable levels without the use of active divertor cooling systems. In addition, SPARC operation presents a unique opportunity to study divertor heat exhaust mitigation at reactor-level plasma densities and power fluxes. Not only will SPARC test the limits of current experimental scalings and serve for benchmarking theoretical models in reactor regimes, it is also being designed to enable the assessment of long-legged and X-point target advanced divertor magnetic configurations. Experimental results from SPARC will be crucial to reducing risk for a fusion pilot plant divertor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the parameter space of MagLIF implosions using similarity scaling. III. Rise-time scaling

Magnetized liner inertial fusion (MagLIF) is a z-pinch magneto-inertial-fusion concept studied at the Z Pulsed Power Facility of Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach the peak current. It is known that, when driving a z-pinch load with a longer current-rise time, the performance of the z-pinch decreases. However, a theory to understand and quantify this effect is still lacking. Here, in this paper, we utilize a framework based on similarity scaling to analytically investigate the variations in the performance of MagLIF loads when varying the current-rise time, or equivalently, the implosion timescale. To maintain similarity between the implosions, we provide scaling prescriptions of experimental input parameters defining a MagLIF load and derive the expected scaling laws for stagnation conditions and for various performance metrics. We compare predictions of the theory to 2D numerical simulations using the radiation, magneto-hydrodynamic code hydra. For several metrics, we find acceptable agreement between the theory and simulations. Our results show that the voltage φload near the MagLIF load follows a weak scaling law φload ∝$t_{φ}^{-0.12}$ with respect to the characteristic timescale t φ of the voltage source, instead of the ideal φload ∝$t_{φ}^{-1}$ scaling. This occurs because the imploding height of the MagLIF load must increase to preserve end losses. As a consequence of the longer imploding liners, the required total laser preheat energy and delivered electric energy increase. Overall, this study helps understand the trade-offs of the MagLIF design space when considering future pulsed-power generators with shorter and longer current-rise times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Coordination Chemistry and Stoichiometry of Extracted Diglycolamide Complexes of Lanthanides in Extraction Chromatography Materials

Industrial rare earth element (REE) separations predominantly utilize solvent extraction processes tailored toward conventional resources such as bastnäsite, monazite, and ion adsorption clays. Advances in diglycolamide (DGA) chemistry have shown effective extraction characteristics for REE separations. However, limitations associated with traditional DGA solvent extraction techniques, such as third-phase formation and gelling, have hindered commercial viability. By supporting DGA extractants on porous resins such as polystyrene divinyl benzene (PS-DVB), the desirable combination of solvent extraction selectivity and ease of operation of sorbent columns can be achieved. To design a low-cost model for such solid-supported DGAs, extraction characteristics as influenced by the underlying coordination chemistry must be explored to achieve efficient functional systems. Within this study, we report novel DGA resin materials, each incorporating one of the DGAs N,N,N’,N’-tetra-(1-octyl)-3-oxapentane-1,5-diamide (TODGA), N,N'-dimethyl-N,N'-dioctyl-3-oxapentane-1,5-diamide (DMDODGA), and 2,2'-oxybis(1-(3-(((2-ethylhexyl)thio)methyl)-4-methylpyrrolidin-1-yl)ethan-1-one) (DEHPDGA). The affinity of DGAs across the lanthanide (Ln) series was evaluated for both hydrochloric acid and nitric acid media with varying Ln feed concentrations to study distribution ratios and loading characteristics. Focusing on dysprosium, extended X-Ray Absorption Fine Structure (EXAFS) and density functional theory (DFT) calculations were also utilized to explore coordination chemistry and their effects on ligand performance. The general trend for both acid media resulted in DMDODGA having the highest extraction strength of all three DGAs at varying acid concentrations. Coordination-chemistry analysis supported by loading data, DFT calculations, and EXAFS results under forced loading conditions posited less than the expected 3:1 ligand-to-metal coordination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Logical gates embedding in artificial spin ice

The realization and study of arrays of interacting magnetic nanoislands, such as artificial spin ices, have reached mature levels of control that allow design and demonstration of exotic, collective behaviors not seen in natural materials. Advances in the direct manipulation of their local, binary moments also suggest a use as nanopatterned, interacting memory media, for computation within a magnetic memory. Recent experimental work has demonstrated the possibility of building logic gates from clusters of interacting magnetic domains, and yet the possibility of large scale integration of such gates can prove problematic even at the theoretical level. Here we introduce theoretically complete sets of logical gates, in principle realizable in an experiment, and we study the feasibility of their integration into tree-like circuits. By evaluating the fidelity control parameter between their collective behavior and their expected logic functionality we determine conditions for integration. Also, we test our numerical results against the presence of disorder in the couplings, showing that the design gate structure is robust to small coupling perturbations, and thus possibly to small imperfections in the fabrication of the islands.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background studies and normalization of signal events in the Mu2e experiment

The Mu2e experiment is currently being constructed at Fermilab to search for the neutrino-less conversion of negative muons into electrons in the field of an aluminum nucleus. The experiment aims at a sensitivity of four orders of magnitude higher than previous related experiments, which implies highly demanding accuracy requirements both in the design and during the operation. To achieve such a goal, two important tasks should be accomplished. First, it is essential to estimate precisely the particle yields and all the backgrounds that could mimic the monoenergetic conversion electron signal. Second, it is necessary to normalize the signal events accurately. The normalization of the signal events is planned to be done using a detector system made of an HPGe detector and a Lanthanum Bromide detector, which will measure the rate of muons stopped on the aluminum target by looking at the emitted characteristic X-and γ-rays of energies up to 1809 keV. Therefore, it is essential to evaluate the detector system's performance before the start of the actual experiment. In this study, the first task was addressed by an extensive campaign of Monte Carlo simulations to investigate the relevant parameters and their impact on the experiment's sensitivity. The second task was handled by taking advantage of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) pulsed Bremsstrahlung photon beam at the ELBE facility. The detector system was tested at the ELBE facility under timing and background conditions similar to the ones expected at the Mu2e experiment. The study presents and discusses the simulation results and the detector system testing campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of DER Momentary Cessation and Rate-of-Change-of-Frequency Response

Momentary cessation (MC) and response to rate-of-change-of-frequency (ROCOF) are inverter responses that can have serious impact on the stability of the grid during abnormal conditions. Though IEEE Std 1547-2018 provides fairly well defined expected responses from inverter-based DERs during abnormal grid conditions, a significant portion of currently installed DERs in the distribution network do not have a well defined response to abnormal grid conditions. Any analysis of the grid involving inverter MC and ROCOF response must consider the specific characteristics of these responses for the installed DERs to have better confidence in the analysis results, especially for grids with high levels of DERs. However, there is lack of information on MC and ROCOF response for the inverters already installed in the field. In this paper, we examine a large data set of installed inverters to map the dominant population of installed inverters. This information is then used to characterize the most dominant MC and ROCOF responses of installed inverters using experimental data.

DER↗

K in an Urban World: New Contexts for Hydraulic Conductivity

Abstract Hydraulic conductivity ( K ) is a key hydrologic parameter widely recognized to be difficult to estimate and constrain, with little consistent assessment in disturbed, urbanized soils. To estimate K , it is either measured, or simulated by pedotransfer functions, which relate K to easily measured soil properties. We measured K in urbanized soils by double‐ring infiltrometer ( K dring ), near‐saturated tension infiltrometry ( K minidisk ), and constant head borehole permeametry ( K borehole ), along with other soil properties across the major soil orders in 12 United States cities. We compared measured K with that predicted from the pedotransfer function, ROSETTA. We found that regardless of soil texture, K dring was consistently larger than K minidisk ; with the latter having slightly less sample variance. K borehole was dependent upon specific subsurface conditions, and contrary to common expectations, did not always decrease with depth. Based on either soil textural class, or percent textural separates (sand, silt clay), ROSETTA did not accurately predict measured K for surface nor subsurface soils. We go on to discuss how K varies in urban landscapes, the role of measurement methods and artifacts in the perception of this metric, and implications for hydrologic modeling. Overall, we aim to inspire consistency and coherence when addressing K ‐related challenges in sustainable urban water management.

Shuster, W. D.↗

A tandem radiative/evaporative cooler for weather-insensitive and high-performance daytime passive cooling

Radiative cooling and evaporative cooling with low carbon footprint are regarded as promising passive cooling strategies. However, the intrinsic limits of continuous water supply with complex systems for evaporative cooling, and restricted cooling power as well as the strict requirement of weather conditions for radiative cooling, hinder the scale of their practical applications. Here, we propose a tandem passive cooler composed of bilayer polymer that enables dual-functional passive cooling of radiation and evaporation. Specifically, the high reflectivity to sunlight and mid-infrared emissivity of this polymer film allows excellent radiative cooling performance, and its good atmospheric water harvesting property of underlayer ensures self-supply of water and high evaporative cooling power. Consequently, this tandem passive cooler overcomes the fundamental difficulties of radiative cooling and evaporative cooling and shows the applicability under various conditions of weather/climate. It is expected that this design can expand the practical application domain of passive cooling.

54 ENVIRONMENTAL SCIENCES↗

Effects of salinity and nutrients on metabolism and growth of Ulva lactuca: implications for bioremediation in San Diego Bay and Coastal Watershed

Our project sought to explore the ability of seaweed (Ulva lactuca) farms to clean polluted waterways of excess nitrogen and phosphorus through bioremediation. We addressed this goal in three primary ways. First, we worked with an undergraduate student from the Environmental Sciences Department at SDSU (Emily Bews) to examine how Ulva would perform under elevated nutrients and decreased salinity conditions, such as would be expected on the seaweed farms during periods of high rainwater runoff. This would show whether Ulva could indeed be grown on farms during these periods. We conducted laboratory experiments at SDSU’s CMIL (marine laboratory) using orthogonal combinations of two salinities and three nutrient loadings, and measured several aspects of Ulva physiology, namely growth, photosynthetic rates, chlorophyll fluorescence, and stable isotope analyses of Ulva’s tissues, and tissue uptake of phosphorus and nitrogen. Our results clearly show Ulva is an ideal candidate for using on farms during periods of heavy rains and takes up excess nutrients. The results of this were published in Marine Pollution Bulletin, with undergraduate Bews as lead author (Bews, E., L. Booher, T. Polizzi, C. Long, J-H Kim, MS Edwards. 2021. Effects of salinity and nutrients on metabolism and growth of Ulva lactuca: implications for bioremediation of coastal watersheds. Marine Pollution Bulletin 166: 121299.).

59 BASIC BIOLOGICAL SCIENCES↗

Report on DIC Cyclic Dryout Testing of ATF Cladding Materials

Boiling water reactors can experience anticipated operational occurrences, where an expected deviation from normal operating conditions is witnessed for short time scales. One example of such transients arises from cladding dryout, where stable boiling becomes unstable, resulting in cladding heat up before re-wetting occurs. To understand the impact of such transients on fuel cladding lifetime and performance, cyclic dryout conditions were imposed upon fresh fuel cladding in the absence of irradiation. Pressurized cladding tube segments were exposed to rapid temperature increases to intermediate temperatures below a cladding rupture threshold and deformation was monitored in situ via 3-D digital image correlation. The impact of cycle frequency on cladding deformation was assessed. A clear understanding of elastic and plastic strain responses were developed for Zr alloy deformation under temperature transients, and these results can be used to support material model development and validate fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-DTL Beam Delivery

Ensuring that the beam delivered from the upgraded Front-End (FE) meets the Key Performance Parameters (KPPs) at each user facility is critical to the success of the LANSCE Accelerator Modernization Project (LAMP). For a high-intensity, multi-user facility like LANSCE, compliance with beam loss and radiation thresholds is as important as the charge delivered to each target. While early LAMPF/LANSCE operations relied on iterative tuning to minimize losses from beam halo and tail particles, the new FE may introduce different beam distributions and loss modes—making predictive modeling essential. To manage this, the F2E (Front-End to End) effort is developing detailed particle-tracking models that reflect realistic beamline conditions, including halo formation and expected diagnostic readings. These "snapshot" simulations aim to benchmark live machine performance at a given moment. This will help quantify how beam quality from the new FE will propagate downstream through the facility. Only by validating these models can we confidently assess and mitigate the potential impacts of the LAMP FE on beam delivery. Post-DTL, the beam splits to serve five major user facilities. Historically, low-energy beam transport has been modeled using TRACE, and higher-energy sections with TRANSPORT. These have now been unified into MAD-X format and validated with codes such as Elegant, pyOrbit, XSuite, Impact-Z, and HPSim. The primary focus now is on accurate modeling of full particle distributions (including beam halo) as they traverse the accelerator and beamlines to each experimental station. All models are at various stages of validation with empirical data.

43 PARTICLE ACCELERATORS↗

Extreme Wind and Waves in U.S. East Coast Offshore Wind Energy Lease Areas

The Outer Continental Shelf along the U.S. east coast exhibits abundant wind resources and is now a geographic focus for offshore wind deployments. This analysis derives and presents expected extreme wind and wave conditions for the sixteen lease areas that are currently being developed. Using the homogeneous ERA5 reanalysis dataset it is shown that the fifty-year return period wind speed (U50) at 100 m a.s.l. in the lease areas ranges from 29.2 to 39.7 ms -1 . After applying corrections to account for spectral smoothing and averaging period, the associated pseudo-point U50 estimates are 34 to 46 ms -1 . The derived uncertainty in U50 estimates due to different distributional fitting is smaller than the uncertainty associated with under-sampling of the interannual variability in annual maximum wind speeds. It is shown that, in the northern lease areas, annual maximum wind speeds are generally associated with intense extratropical cyclones rather than cyclones of tropical origin. Extreme wave statistics are also presented and indicate that the 50-year return period maximum wave height may substantially exceed 15 m. From this analysis, there is evidence that annual maximum wind speeds and waves frequently derive from the same cyclone source and often occur within a 6 h time interval.

16 TIDAL AND WAVE POWER↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

Destructive Examination of a FeCrAl-UO 2 Irradiation Test

Several destructive postirradiation examinations were performed on an irradiation specimen that coupled an early iron-chromium-aluminum (FeCrAl) candidate alloy cladding with UO2 pellets. This irradiation test was designed to investigate the early life performance and compatibility of the FeCrAl-UO 2 cladding-fuel system under prototypic light water reactor neutronic conditions. Additionally, these tests were expected to provide neutron irradiated samples for severe accident testing of this fuel system. The irradiation studied in this work was part of the ATF-1 series of drop-in style irradiations performed in the Idaho National Laboratory Advanced Test Reactor. The rodlet studied in this work is one of three similar rodlets irradiated in ATF-1 that had approximately 7.6 cm of cladding machined from a wrought FeCrAl alloy and fueled with a 6.1 cm stack of UO 2 pellets. The outer diameter of the cladding was ~0.94 cm and the inner diameter was ~0.83 cm. After irradiation and non-destructive examination in Idaho this rodlet was shipped to the Oak Ridge National Laboratory hot-cells for further examination. The irradiated rodlet was sectioned into several samples for microstructural, micromechanical, and severe accident testing. During sectioning, it was noted that the fuel was not firmly bonded to the cladding and could be readily removed from small cladding slices. Microstructural characterization of fuel cross sections also revealed no significant interaction between the fuel and the cladding. Samples were also prepared for microhardness testing. To prepare for high temperature oxidation testing, the fuel was dissolved from segments of the cladding. High temperature oxidation testing of cladding segments was performed at 1200°C and 1300°C in a steam environment. Comparisons between the oxidation of this FeCrAl alloy in its neutron irradiated state, as-fabricated state, and the oxidation of Zircaloy-2 are made. The oxidation testing will be followed by ring compression testing to evaluate ductility. The microstructure of the samples after oxidation and ring compression testing will also be analyzed.

Harp, Jason↗

Kernel Buffer Volume Fraction Margin of the AGR Designed Fuel Particle

Modeling results used to assess the fuel performance of the TRISO-coated fuel particles as a function of kernel/buffer volume fraction include SiC tangential stress, formation of the buffer/IPyC gap, particle temperature profile, internal particle pressure, fission gas released from the kernel, probability of fuel particle failure, and fission product diffusion. These results were evaluated at two burnup levels and irradiation temperatures to bound expected steady-state irradiation conditions. In general, increasing the kernel/buffer volume fraction increases the SiC stress and subsequently the failure probability of a fuel particle when compared to the AGR designed particle. There was little impact on the fission product diffusion through the particle as the kernel/buffer volume fraction increased.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Analysis of FSV Spent Nuclear Fuel in the DOE Standard Canister

The U.S. Department of Energy (DOE) is responsible for managing over 300 types of spent nuclear fuel (SNF). To manage this large variety of fuel types, DOE plans to employ standardized canisters for the transportation, long-term storage, and eventual disposal of SNF. Idaho National Laboratory is currently supporting DOE’s SNF Packaging Demonstration Project, in which Fort Saint Vrain (FSV) fuel assemblies will be loaded into a DOE Standard Canister. This paper presents criticality calculations demonstrating that all four or five FSV fuel assemblies loaded into the DOE Standard Canister will remain subcritical in any expected normal or credible abnormal conditions. Previous criticality analyses were performed for one FSV fuel assembly and 12 Peach Bottom Core 2 fuel elements loaded into a DOE Standard Canister. This paper covers the criticality analysis performed for loading both four and five FSV fuel assemblies into a DOE Standard Canister. Various intact and degraded mode configurations were modeled in conducting the criticality calculations. This analysis encompassed three different configurations: (1) a single DOE Standard Canister loaded into a concrete storage overpack, (2) seven DOE Standard Canisters loaded into a concrete storage overpack, and (3) nine DOE Standard Canisters loaded into a concrete storage overpack. The overpack dimensions were varied for each of the three configurations, and transport, storage, and disposal scenarios were analyzed for each configuration. For transport scenarios, a pair of degradation cases was analyzed. In the first case, the fuel compacts became degraded and were removed from the fuel block, then deposited at the bottom of a horizontally placed canister, thereby simulating a drop event. The canister was considered to remain intact. In the second case, the spacing between horizontally placed canisters in a nine-canister overpack was reduced such that the canisters were piled on top of each other, simulating a drop event. For this case, no degradation of the canister internals or fuel was considered. For storage scenarios, the water moderator location in the system was varied to enable identification of the most reactive configurations. Dry and wet conditions were analyzed for the fuel materials, canister, and overpack. For disposal scenarios, two degradation cases were analyzed. In the first, the stainless-steel internals of the canister degraded to either hematite or goethite under both dry and wet conditions. In the second case, degraded FSV fuel formed a uranium-water slurry that filled the coolant/void holes. None of the cases presented exceeded the application specific upper subcritical limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗