Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Optimization of Operating Profit for the FEED of the PZAS Process for CO 2 Capture on a 460 MW NGCC

A rating model of PZAS (Piperazine with the Advanced Stripper) for a 460 MW natural gas combined cycle was developed from vendor-provided equipment performance data. Surrogate rating models were built and used to optimize variable profit of the system subject to natural gas and electricity price at a fixed value for CO 2 of $\$80$/tonne. Several process constraints were considered between ambient temperatures of 4.4 and 40.5 °C. Lower lean loading resulted in lower reboiler heat duty of about 2.2 GJ/tonne. Lean loading at 0.2 mol/equiv N was sufficient at an ambient temperature of 4.4 °C to maximize variable profit. Solvent precipitation was avoided even at low lean loading (0.18 mol/mol) in the absence of a trim cooler for the lean solvent between the absorber and the cold cross exchanger. Optimal CO 2 removal was always higher than the design case removal of 90% and achieved a peak of 93.6% for 4.4 ºC ambient temperature. Lean solvent rate was a significant driver of profitability. The maximum capacity of the compressor was a significant constraint on profitability. Increasing compressor capacity by 20–30% could increase variable profit by about 21% in the case of 0.18 lean loading at 4.4 °C ambient temperature. Furthermore, this increase in profit was lower at higher ambient temperature and higher lean loading. The breakeven gas price was $\$4.6$/MMBtu at high lean loading of 0.22 mol/mol. Below this value, profit was maximized by increasing the boiler heat rate. Above this value, profit could not be increased by burning additional natural gas, requiring a reduction in boiler heat rate and consequently, specific heat duty. At lower lean loading (0.2, 0.18 mol/mol), this transition in heat duty was not observed due to the lower heat duty. As the ambient temperature increased, a similar trend in heat duty was observed at 0.22 lean loading, but the transition to lower heat duty occurred earlier at $\$4$/MMBtu. This was because of the lower CO 2 production at higher ambient temperature, making the process unprofitable at a gas price higher than $\$3$/MMBtu unless the heat duty of the stripper and natural gas boiler is steeply decreased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pd-Ru pair on Pt surface for promoting hydrogen oxidation and evolution in alkaline media

Hydrogen oxidation reaction in alkaline media is critical for alkaline fuel cells and electrochemical ammonia compressors. The slow hydrogen oxidation reaction in alkaline electrolytes requires large amounts of scarce and expensive platinum catalysts. While transition metal decoration can enhance Pt catalysts’ activity, it often reduces the electrochemical active surface area, limiting the improvement in Pt mass activity. Here, we enhance Pt catalysts’ activity without losing surface-active sites by using a Pd-Ru pair. Utilizing a mildly catalytic thermal pyrolysis approach, Pd-Ru pairs are decorated on Pt, confirmed by extended X-ray absorption fine structure and high-angle annular dark-field scanning transmission electron microscopy. Density functional theory and ab-initio molecular dynamics simulations indicate preferred Pd and Ru dopant adsorption. The Pd-Ru decorated Pt catalyst exhibits a mass-based exchange current density of 1557 ± 85 A g –1 metal for hydrogen oxidation reaction, demonstrating superior performance in an ammonia compressor.

25 ENERGY STORAGE↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Commissioning plan for LCLS II 2 K cold box

Commissioning of the LCLS II cryogenic plant has been planned with respect to electrical and mechanical systems checkout, equipment cleanup, cool-down, and individual performance evaluation. This plant consists of warm and cold storage, helium compressors, 4.5 K and 2 K cold boxes, and all auxiliaries typical for helium refrigeration processes. The 2 K cold box, consisting of five cold compressors in series to produce the flow and pressures necessary for 2K operation, will be the last equipment installed and, along with an additional 10,000 L helium dewar, will allow the entire plant to be commissioned as a single entity. The pre-commissioning stages, commissioning plan for 2 K cold box without connecting to the LCLS II LINAC, additional test equipment needed to simulate the loads, all process studies and associated results are described herein.

36 MATERIALS SCIENCE↗

Unbalanced Parallel I/O: An Often-Neglected Side Effect of Lossy Scientific Data Compression

Lossy compression techniques have demonstrated promising results in significantly reducing the scientific data size while guaranteeing the compression error bounds. However, one important yet often neglected side effect of lossy scientific data compression is its impact on the performance of parallel I/O. Our key observation is that the compressed data size is often highly skewed across processes in lossy scientific compression. To understand this behavior, we conduct extensive experiments where we apply three lossy compressors MGARD, ZFP, and SZ, which are specifically designed and optimized for scientific data, to three real-world scientific applications Gray-Scott simulation, WarpX, and XGC. Our analysis result demonstrates that the size of the compressed data is always skewed even if the original data is evenly decomposed among processes. Such skewness widely exists in different scientific applications using different compressors as long as the information density of the data varies across processes. We then systematically study how this side effect of lossy scientific data compression impacts the performance of parallel I/O. We observe that the skewness in the sizes of the compressed data often leads to I/O imbalance, which can significantly reduce the efficiency of I/O bandwidth utilization if not properly handled. In addition, writing data concurrently to a single shared file through MPI-IO library is more sensitive to the unbalanced I/O loads. Therefore, we believe our research community should pay more attention to the unbalanced parallel I/O caused by lossy scientific data compression.

Wang, Xinying↗

Spatiotemporally Adaptive Compression for Scientific Dataset with Feature Preservation – A Case Study on Simulation Data with Extreme Climate Events Analysis

Scientific discoveries are increasingly constrained by limited storage space and I/O capacities. For time-series simulations and experiments, their data often need to be decimated over timesteps to accommodate storage and I/O limitations. In this paper, we propose a technique that addresses storage costs while improving post-analysis accuracy through spatiotemporal adaptive, error-controlled lossy compression. We investigate the trade-off between data precision and temporal output rates, revealing that reducing data precision and increasing timestep frequency lead to more accurate analysis outcomes. Additionally, we integrate spatiotemporal feature detection with data compression and demonstrate that performing adaptive error-bounded compression in higher dimensional space enables greater compression ratios, leveraging the error propagation theory of a transformation-based compressor. To evaluate our approach, we conduct experiments using the well-known E3SM climate simulation code and apply our method to compress variables used for cyclone tracking. Our results show a significant reduction in storage size while enhancing the quality of cyclone tracking analysis, both quantitatively and qualitatively, in comparison to the prevalent timestep decimation approach. Compared to three state-of-the-art lossy compressors lacking feature preservation capabilities, our adaptive compression framework improves perfectly matched cases in TC tracking by 26.4-51.3% at medium compression ratios and by 77.3-571.1% at large compression ratios, with a merely 5–11% computational overhead.

Gong, Qian↗

A General Framework for Error-controlled Unstructured Scientific Data Compression

Data compression plays a key role in reducing storage and I/O costs. Traditional lossy methods primarily target data on rectilinear grids and cannot leverage the spatial coherence in unstructured mesh data, leading to suboptimal compression ratios. We present a multi-component, error-bounded compression framework designed to enhance the compression of floating-point unstructured mesh data, which is common in scientific applications. Our approach involves interpolating mesh data onto a rectilinear grid and then separately compressing the grid interpolation and the interpolation residuals. This method is general, independent of mesh types and typologies, and can be seamlessly integrated with existing lossy compressors for improved performance. We evaluated our framework across twelve variables from two synthetic datasets and two real-world simulation datasets. The results indicate that the multi-component framework consistently outperforms state-of-the-art lossy compressors on unstructured data, achieving, on average, a 2.3 − 3.5× improvement in compression ratios, with error bounds ranging from 1 × 10 the −6 to 1×10−2. We further investigate impact of hyperparameters, such as grid spacing and error allocation, to deliver optimal compression ratios in diverse datasets.

Gong, Qian↗

A High-Quality Workflow for Multi-Resolution Scientific Data Reduction and Visualization

Multi-resolution methods such as Adaptive Mesh Refinement (AMR) can enhance storage efficiency for HPC applications generating vast volumes of data. However, their applicability is limited and cannot be universally deployed across all applications. Furthermore, integrating lossy compression with multi-resolution techniques to further boost storage efficiency encounters significant barriers. To this end, we introduce an innovative workflow that facilitates high-quality multi-resolution data compression for both uniform and AMR simulations. Initially, to extend the usability of multi-resolution techniques, our workflow employs a compression-oriented Region of Interest (ROI) extraction method, transforming uniform data into a multi-resolution format. Subsequently, to bridge the gap between multi-resolution techniques and lossy compressors, we optimize three distinct compressors, ensuring their optimal performance on multi-resolution data. These optimizations can improve the compression ratio of SOTA approaches by up to 3.3× under the same data quality loss. Lastly, we incorporate an advanced uncertainty visualization method into our workflow to understand the potential impacts of lossy compression. Experimental evaluation demonstrates that our workflow achieves significant compression quality improvements.

Wang, Daoce↗

Operation of Natural Gas Pipeline Networks With Storage Under Transient Flow Conditions

Here, we formulate a nonlinear optimal control problem for intraday operation of a natural gas pipeline network that includes storage reservoirs. The dynamics of compressible gas flow through pipes, compressors, reservoirs, and wells are considered. In particular, a reservoir is modeled as a rigid, hollow container that stores gas under isothermal conditions and uniform density, and a well is modeled as a vertical pipe. For each pipe, flow dynamics are described by a coupled partial differential equation (PDE) system in density and mass flux variables, with momentum dissipation modeled using the Darcy–Wiesbach friction approximation. Compressors are modeled as scaling up the pressure of gas between the inlet and outlet. The governing equations for all network components are spatially discretized and assembled into a nonlinear differential-algebraic equation (DAE) system, which synthesizes above-ground pipeline and subsurface reservoir dynamics into a single reduced-order model. We seek to maximize an objective function that quantifies economic profit and network efficiency subject to the flow equations and inequalities that represent operating limitations. The problem is solved using a primal–dual interior point solver, and the solutions are validated in computational experiments and simulations on several pipeline test networks to demonstrate the effectiveness of the proposed methodology.

03 NATURAL GAS↗

What to Support When You’re Compressing

Over the last nearly 20 years, lossy compression has become an essential aspect of HPC applications’ data pipelines, allowing them to overcome limitations in storage capacity and bandwidth and, in some cases, increase computational throughput and capacity. However, with the adoption of lossy compression comes the requirement to assess and control the impact lossy compression has on scientific outcomes. In this work, we take a major step forward in describing the state of practice and by characterizing workloads. We examine applications’ needs and compressors’ capabilities across 9 different supercomputing application domains. We present 24 takeaways that provide best practices for applications, operational impacts for facilities achieving compressed data, and gaps in application needs not addressed by production compressors that point towards opportunities for future compression research.

Error-Bounded Lossy Compression↗

Pipeline Hydrogen Decarbonization and Repurposing Analyzers (P-HyDRAs)

The Pipeline Hydrogen Decarbonization and Repurposing Analyzers (P-HyDRAs) are a set of prototype computational tools for simulating and optimizing midstream natural gas pipeline system operations subject to location and time-dependent hydrogen blending. The models can accurately resolve dynamic gas flows through large-scale pipeline networks using non-ideal gas equations of state. The codes can be used as decision support for planning and design decisions involving intra-day energy flow schedules as well as spatiotemporal economic values of natural gas, hydrogen, and net energy delivered to consumers while ensuring that pipeline hydraulic limitations, gas compressor station constraints, operational factors, and pre-existing shipping contracts are satisfied. The inputs to the codes are a model of the pipeline system as well as time-series data that specify boundary conditions on the network. For optimization, the code module requires price and quantity offers for natural gas and hydrogen and price and quantity bids for energy, which are used as time-dependent constraints in an optimal control problem. The outputs are time-series data that provide a predictive simulation of gas flows, mass fractions, and pressures, or with additional degrees of freedom give an approximately optimal solution for gas injections/withdrawals, compressor settings, and sensitivities to the objective function that provide locational values of energy.

Zlotnik, Anatoly↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Influence of defects on the femtosecond laser damage resistance of multilayer dielectric gratings

Multilayer dielectric (MLD) gratings with high diffraction efficiency and a high laser-induced damage (LID) threshold for pulse compressors are key to scaling the peak and average power of chirped pulse amplification lasers. However, surface defects introduced by manufacturing, storage, and handling processes can reduce the LID resistance of MLD gratings and impact the laser output. The underlying mechanisms of such defect-initiated LID remain unclear, especially in the femtosecond regime. In this Letter, we model dynamic processes in interactions of a 20-fs near-infrared (NIR) laser pulse and a MLD grating design in the presence of cylindrically symmetrical nodules and particle contaminants and cracks at the surface. Utilizing a dynamic model based on a 2D finite difference in time domain (FDTD) field solver coupled with photoionization, electron collision, and refractive index modification, we study the simulation results for the damage site distribution initiated by defects of various types and sizes and its impact on the LID threshold of the grating design.

Zhang, Simin (ORCID:0000000174948230)↗

Toward Quantity-of-Interest Preserving Lossy Compression for Scientific Data

Today's scientific simulations and instruments are producing a large amount of data, leading to difficulties in storing, transmitting, and analyzing these data. While error-controlled lossy compressors are effective in significantly reducing data volumes and efficiently developing databases for multiple scientific applications, they mainly support error controls on raw data, which leaves a significant gap between the data and user's downstream analysis. This may cause unqualified uncertainties in the outcomes of the analysis, a.k.a quantities of interest (QoIs), which are the major concerns of users in adopting lossy compression in practice. In this paper, we propose rigorous mathematical theories to preserve four families of QoIs that are widely used in scientific analysis during lossy compression along with practical implementations. Specifically, we first develop the error control theory for univariate QoIs which are essential for computing physical properties such as kinetic energy, followed by multivariate QoIs that are more commonly used in real-world applications. The proposed method is integrated into a state-of-the-art compression framework in a modular fashion, which could easily adapt to new QoIs and new compression algorithms. Experiments on real-world datasets demonstrate that the proposed method provides faithful error control on important QoIs including kinetic energy, regional average, and isosurface without trials and errors, while offering compression ratios that are up to 4x of the compression ratios provided by state-of-the-art compressors.

Jiao, Pu↗

Summary for Z-Petawatt Laser Activities (CY2019)

The high-energy upgrade of the Z-Petawatt (ZPW) laser system involved a shot hiatus starting in October 2018 to allow the installation of full-aperture optics in the chain, including in the main amplifier section as well as in the branches associated with the ZPW compressor and co-injection (the narrowband nanosecond operating mode that is co-bored with Z-Beamlet). Laser shots resumed May 1 st , with most shots since being in the ns mode to reduce complexity (while conditioning optics and calibrating diagnostics) as well as to support experimental requests. To facilitate experimental needs while a final full-sized co-injection optic was prepared, a sub-apertured beam has been used for experimental applications and a full-apertured beam has been used to validate the system. In the latter case, the beam is directed to a large calorimeter placed before branching occurs to the ZPW compressor or co-injection. As of September 2019, full-aperture co-injection shots had ramped up to 960J in 2.3ns, with many cross-calibrations being used to map out a relative humidity dependency in the leaky diagnostic mirror. Several such cross-calibration shots have been done using a chirped pulse seed as well, verifying that the diagnostic calibrations are valid in both broadband and narrow-band modes. Summarizing, since May 1 st of 2019 when shots resumed, 93 full system shots were performed with the ZPW laser. This included 2 co-injection shots with ZBL into Z (in support of MagLIF), 26 Pecos gas cell shots (in support of MagLIF), 11 Conchas gas cell shots (in support of UXI applications development), 6 Jemez shots (in support of backlighter development), and 48 calorimeter shots (in support of validating the system performance). Of these 93 shots, 45 shots were in conjunction with ZBL.