Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cold climate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Global scale assessment of urban precipitation anomalies

Urbanization has accelerated dramatically across the world over the past decades. Urban influence on surface temperatures is now being considered as a correction term in climatological datasets. Although prior research has investigated urban influences on precipitation for specific cities or selected thunderstorm cases, a comprehensive examination of urban precipitation anomalies on a global scale remains limited. This research is a global analysis of urban precipitation anomalies for over one thousand cities worldwide. We find that more than 60% of the global cities and their downwind regions are receiving more precipitation than the surrounding rural areas. Moreover, the magnitude of these urban wet islands has nearly doubled in the past 20 y. Urban precipitation anomalies exhibit variations across different continents and climates, with cities in Africa, for example, exhibiting the largest urban annual and extreme precipitation anomalies. Cities are more prone to substantial urban precipitation anomalies under warm and humid climates compared to cold and dry climates. Cities with larger populations, pronounced urban heat island effects, and higher aerosol loads also show noticeable precipitation enhancements. This research maps global urban rainfall hotspots, establishing a foundation for the consideration of urban rainfall corrections in climatology datasets. This advancement holds promise for projecting extreme precipitation and fostering the development of more resilient cities in the future.

Science & Technology - Other Topics↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Migrating Populus with climate change: Phenology, coppice management, cold spell susceptibility, leaf dynamics, and biomass production

Understanding the phenology and productivity of Populus species is crucial for effective management and conservation strategies amid climate change. We investigated leaf budbreak timing, susceptibility to cold damage, leaf dynamics, and biomass production of 168 Populus genotypes with diverse provenances in the southeastern United States. Our study revealed significant variation in budbreak timing across different taxa and years, with genotypes inheriting traits adapted to their parents’ local climates. Temperature emerged as a key factor triggering budbreak, while leaf development depended on other environmental cues such as photoperiod. Notably, budbreak occurred approximately 20 days earlier in 2023 compared to 2022 due to higher accumulated degree days (ADDs). Short-rotation-coppice (SRC) management delayed budbreak by five to ten days. Cold damage was significant in 2023, particularly for genotypes from northern provenances and those with P. maximowiczii parentage. Severe damage was also observed in eastern cottonwood ( Populus deltoides ​× ​ Populus deltoides (D ​× ​D)) genotypes, despite most having southeastern US parentages. Leaf dynamics, including leaf duration and leaf area index (LAI), varied across taxa and sites, with earlier budbreak correlating with extended growing seasons and increased LAI. Biomass production was intricately linked to phenological events, with earlier budbreak leading to increased biomass production and greater susceptibility to cold damage. Our findings highlight the importance of genetics, environment, and coppicing management in understanding and managing Populus phenology and biomass production. These insights provide valuable guidance for developing effective breeding, conservation, and management strategies for Populus species in the context of climate change.

Accumulated degree days (ADDs)↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Applying NIR and MIR spectroscopy for C and soil property prediction in northern cold-region ecosystems. Which approach works better?

Here, developing reliable predictions of soil attributes is necessary to understand northern cold-region climate-soil feedback. Calibration models using near-infrared (NIR) and mid-infrared (MIR) spectroscopy were developed to predict eight commonly measured soil properties for 119 soil samples representing a range of vegetation types, parent materials, and soil types spanning >23° of latitude from southeast Alaska to the Canadian high Arctic. In order to obtain a more accurate prediction, this study compared the performance of linear and non-linear calibration techniques, including lasso regression (Lasso), support vector machine (SVM), random forest (RF) and classic partial least squares (PLS) to predict different soil properties of these soils. Comparing the four models, we noticed that their performance was quite similar for MIR overall, while NIR achieved better results with a PLS model for our dataset. PLS coupled with MIR showed a better performance for soil parameters, such as total organic carbon (TOC), total nitrogen (TN), cation exchange capacity (CEC) and clay (R-squared of 0.9, 0.81, 0.80, and 0.84) when compared with NIR (R-squared of 0.85, 0.72, 0.81 and 0.68). However, using either MIR or NIR spectroscopy, PLS predictions for bulk density (BD) and sand content were not accurate. The variable importance analysis based on the PLS model successfully estimated the relative contribution of wavelengths influencing soil property predictions most. Overall, TOC, TN, CEC and clay mineral predictions are closely related to the occurrence of specific spectral bands in the MIR region. For example, wavelengths at 2978 and 1761 cm -1 for TOC and TN, as well as at 3064 cm -1 for CEC, were selected as the most influential predictor variables. We demonstrated that MIR spectroscopy is a powerful tool for more extensive monitoring in soils of the northern cold climate region; however, NIR could be utilized for rapid estimates when the highest accuracy is not essential.

54 ENVIRONMENTAL SCIENCES↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Reservoirs Modify River Thermal Regime Sensitivity to Climate Change: A Case Study in the Southeastern United States

Seasonal thermal stratification in reservoirs changes the thermal regime of regulated river systems as well as stream temperature responses to climate change. Cold releases from reservoir hypolimnion can depress downstream river temperature during warm seasons. Recent large-scale climate change studies on stream temperature have largely ignored reservoir thermal stratification. In this study, we used established models to develop a framework which considers water demand and reservoir regulation with thermal stratification, and applied this model framework to the southeastern US. About half of all 271 reservoirs in our study area retain strong thermal stratification by the 2080s (2070-2099) under RCP8.5 even as median residence times decrease to 60 days from 69 days in the historic period (1979-2010). Reservoir impacts on downstream temperatures become slightly weaker in the future because of higher air temperature and stronger solar radiation. We defined a “cooling potential” to quantify the thermal energy that a water body can absorb before exceeding a water temperature threshold. In the future, higher river temperatures will reduce the cooling potential for all river segments, but more so for river segments minimally impacted by thermal stratification. Reservoir impacts on cooling potential remain strong for river segments downstream of reservoirs with strong thermal stratification. We conducted a sensitivity analysis to evaluate the robustness of our findings to errors in the hydrological simulations. While river segments subject to reservoir regulation are more sensitive to errors in hydrology than those without regulation impacts, our overall findings do not materially change due to these errors.

54 ENVIRONMENTAL SCIENCES↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Life-cycle cost-benefit analysis of a novel self-heating pavement made from coal-derived solid carbon

Winter weather events challenge the safety, efficiency, and sustainability of roadway networks, particularly road bridges vulnerable to climate impacts. Although effective, conventional de-icing methods incur high expenses and cause significant environmental contamination. To address these longstanding issues, a low-cost novel coal-derived carbon enabled smart pavement (CDC-SP) de-icing system was developed, aiming to alleviate traffic delays, severe corrosion, compromised safety, and environmental pollution. However, the economic performance of CDC-SP has not been quantified to guide decision-making. To this end, this paper presents a Life-Cycle Cost-Benefit Analysis (LCCBA) to assess the economic feasibility of the CDC-SP de-icing system for road bridges in five representative urban and rural areas across cool humid and cold humid climate zones. Given the variations and uncertainties of several factors that determine the costs and benefits, a sensitivity analysis was conducted to determine the system’s economic reliability. Additionally, a Monte Carlo simulation (MCS) was performed to quantify the impacts of important factors and identify the most beneficial scenarios. Furthermore, the CDC-SP de-icing systems have demonstrated substantial economic benefits and short payback periods, showing great applicability for rural and urban road bridges with different service levels across multiple climate zones as compared to conventional de-icing methods.

36 MATERIALS SCIENCE↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applying the index of watershed integrity to the Matanuska–Susitna basin

The Matanuska-Susitna Borough is the fastest growing region in the State of Alaska and is impacted by a number of human activities. We conducted a multiscale assessment of the stressors facing the borough by developing and mapping the Index of Watershed Integrity (IWI) and Index of Catchment Integrity (the latter considers stressors in areas surrounding individual stream segments exclusive of upstream areas). The assessment coincided with the borough’s stormwater management planning. We adapted the list of anthropogenic stressors used in the original conterminous United States IWI application to reflect the borough’s geography, human activity, and data availability. This analysis also represents an early application of the NHDPlus High Resolution geospatial framework and the first use of the framework in an IWI study. We also explored how remediation of one important stressor, culverts, could impact watershed integrity at the catchment and watershed scales. Overall, we found that the integrity scores for the Matanuska– Susitna basin were high compared to the conterminous United States. Low integrity scores did occur in the rapidly developing Wasilla–Palmer core area. We also found that culvert remediation had a larger proportional impact in catchments with fewer stressors.

54 ENVIRONMENTAL SCIENCES↗

Influence of data uncertainty on cold season threshold-based climate indices

Climate indices are used to reduce the complex climate system and its changes to simple measures. The data basis – whether observational data or climate model data – to which the climate indices are applied, is usually subject to uncertainties. For threshold-based climate indices, the data uncertainty influences the threshold value, and, hence, the uncertainty can influence the values for the climate index. What the actual impacts of these uncertainties are on threshold-based climate indices is examined in this paper. The focus is not only on the climate model uncertainty, but also on the observational data uncertainty. The general sensitivity of each of the chosen climate indices to arbitrary changes in the threshold is studied. This shows a higher sensitivity of indices assessing extremes (ice days, heavy precipitation days) to changes in the threshold than indices that integrate a quantity over a given time interval (coldsum, consecutive days). For assessing an ensemble of climate model data with respect to their ability to reproduce the index values for current climate, the reference data uncertainty is applied to the chosen threshold-based climate indices by changing their threshold value by its corresponding uncertainty. It is shown that the climate model uncertainty can be within the range of the reference data uncertainty. When using threshold-based climate indices to assess changes in future climate periods, uncertainties should always be taken into account and ideally corrected in an appropriate way. This is especially important for indices that assess extremes.

54 ENVIRONMENTAL SCIENCES↗

Raw soil carbon dioxide, moisture, temperature and micrometeorological data in the East River Watershed, Colorado June 2021-June 2024. (DE-SC0021139)

This dataset contains raw data from four tripod stations along an elevation gradient on Snodgrass Mountain in the East River Watershed, CO, USA. Each station contains a datalogger connected to 3 soil Carbon Dioxide CO2 gas probes, 3 soil temperature/moisture sensors and a micrometeorological station. Sensors are scanned every minute, and the 30 minute average is reported. The file snodgrass_soil_ESS.csv contains raw data, a row of column descriptors, and units of measurements. some data processing and QA/QC was done to filter out data from sensors that went bad and extreme outliers. CO2 sensors that went bad were replaced with new sensors as soon as possible. This research was performed to investigate the ecohydrological linkages of belowground carbon processes in the East River watershed forested communities to better understand how these ecosystems will respond to a changing cold-season moisture input. This is the second version of this data set and was modified on 10/01/2024. The primary change in the data was the addition of data from the fall of 2022 to June of 2024. In addition, minor QA/QC was done to filter out data from sensors that went bad and extreme outliers. THe filtered data are now NA's in this data frame and primarily the CO2 sensors. Limited to no QA/QC has been done on the other environmental data. This is now the third version of the data set, and was modified 03/25/2026. The primary change in the data was the addition of data from the June of 2024 to December 2025. Further r QA/QC was done with the new data to filter out bad data from faulty sensors and extreme outliers. The filtered data are now NA's in this data frame and primarily the CO2 sensors. Limited to no QA/QC has been done on the other environmental data. ##This additional data was funded under DE-SC0024218( Responses of Plant and Microbial Respiration Sources to Changing Cold Season Climate Drivers in the East River Watershed)

54 ENVIRONMENTAL SCIENCES↗

Launch Alaska Transportation and Energy Accelerator (LATEA)

The Launch Alaska Transportation and Energy Accelerator (LATEA), funded through the U.S. Department of Energy Office of Technology Commercialization’s Energy Program for Innovation Clusters (EPIC),advanced deployment of innovative and efficient transportation and energy technology in Alaska from October 2021 through June 2025. The project was designed to leverage Launch Alaska’s accelerator model to identify, recruit, and support transportation technology companies with novel solutions to market needs while building the stakeholder networks, demonstration opportunities, and institutional capacity necessary to accelerate commercialization in one of the most challenging operating environments in the United States.

08 HYDROGEN↗

The E3 Initiative

The Department of Energy’s Building Technologies Office is developing a national initiative focused on efficient and clean heating and cooling systems in residential and commercial buildings, making it easier to afford and install high-performance heat pump solutions.

HVAC, residential, commercial, Cold Climate Heat P↗

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗