Super NiCd Open-Circuit Storage and Low Earth Orbit (LEO) Life Test Evaluation

This presentation discusses Air Force tests performed on super NiCd cells to measure their performance under conditions simulating Low Earth Orbit (LEO) conditions. Super NiCd cells offer potential advantages over existing NiCd cell designs including advanced cell design with improved separator material and electrode making processes, but handling and storage requires active charging. These tests conclude that the super NiCd cells support generic Air Force qualifications for conventional LEO missions (up to five years duration) and that handling and storage may not actually require active charging as previously assumed. Topics covered include: Test Plan, Initial Characterization Tests, Open-Circuit Storage Tests, and post storage capacities.

Baer, Jean Marie↗

Design, Fabrication, and Performance of Foil Gas Thrust Bearings for Microturbomachinery Applications

A methodology for the design and construction of simple foil thrust bearings intended for parametric performance testing and low marginal costs is presented. Features drawn from a review of the open literature are discussed as they relate to bearing performance. The design of fixtures and tooling required to fabricate foil thrust bearings is presented, using conventional machining processes where possible. A prototype bearing with dimensions drawn from the literature is constructed, with all fabrication steps described. A load-deflection curve for the bearing is presented to illustrate structural stiffness characteristics. Start-top cycles are performed on the bearing at a temperature of 425 C to demonstrate early-life wear patterns. A test of bearing load capacity demonstrates useful performance when compared with data obtained from the open literature.

Dykas, Brian↗

Performance of AEA 80 Ah Battery Under GEO Profile

To date completed three Solar Dynamic Observatory SDO real-time eclipse seasons. Sony 18650HC has a low rate of capacity fade under GEO cycling regime. Real time test results correlate with accelerated GEO lifetest data and AEA capacity fade prediction tool. This data, together with other AEA test data, justify the SDO Project decision to baseline Lithium-Ion chemistry for the spacecraft battery.

Russel, N.↗

Slicing of Silicon into Sheet Material. Silicon Sheet Growth Development for the Large Area Silicon Sheet Task of the Low Cost Solar Array Project

The use of multiblade slurry sawing to produce silicon wafers from ingots was investigated. The commercially available state of the art process was improved by 20% in terms of area of silicon wafers produced from an ingot. The process was improved 34% on an experimental basis. Economic analyses presented show that further improvements are necessary to approach the desired wafer costs, mostly reduction in expendable materials costs. Tests which indicate that such reduction is possible are included, although demonstration of such reduction was not completed. A new, large capacity saw was designed and tested. Performance comparable with current equipment (in terms of number of wafers/cm) was demonstrated.

Fleming, J. R.↗

The 50 Ah NiH2 CPV qualification tests

In 1992, the Naval Research Laboratory (NRL) started a program to qualify a large diameter common pressure vessel (CPV) nickel-hydrogen (NiH2) batteries for use on future Navy/NRL spacecraft electrical power subsystems. NRL's involvement with the qualification of CPV NiH2 batteries dates back to 1988 when COMSAT and Johnson Controls, Inc. initiated a joint effort to fly the first ever NiH2 CPV in space. A later NRL-JCI cooperative research and development agreement led to the launch of a space experiment in 1993 and to the use of a single NiH2 CPV battery on the BMDO Clementine spacecraft in 1994. NRL initiated procurement of two, 50 Ah CPV NiH2 batteries in the Fall of 1992. The two batteries were delivered to NRL in June 1994. NiH2 CPV batteries have almost 2x the specific energy (Wh/kg) of nickel cadium batteries and 2x the energy density (Wh/l) of individual pressure vessel NiH2 CPV's. This presentation discusses the results of electrical and mechanical qualification tests conducted at NRL. The tests included electrical characterization, standard capacity, random vibration, peak load, and thermal vacuum. The last slides of the presentation show initial results from the life cycle tests of the second NiH2 CPV battery at 40% depth of discharge and a temperature of 10 C.

Garner, J. C.↗

Modifications to Marshall's Annular Seal Test (MAST) Rig and Facility for Improved Rotordynamic Coefficient Testing of Annular Seals and Fluid Film Bearings

The limits of rotordynamic stability continue to be pushed by the high power densities and rotational speeds of modern rocket engine turbomachinery. Destabilizing forces increase dramatically with rotor speed. Rotordynamic stability is lost when these destabilizing forces overwhelm the stabilizing forces. The vibration from the unstable rotor grows until it is limited by some nonlinearity. For example, a rolling element bearing with a stiffness characteristic that increases with deflection may limit the vibration amplitude. The loads and deflections resulting from this limit cycle vibration (LCV) can lead to bearing and seal damage which promotes ever increasing levels of subsynchronous vibration. Engineers combat LCV by introducing rotordynamic elements that generate increased stabilizing forces and reduced destabilizing forces. For example, replacing a labyrinth seal with a damping seal results in substantial increases in the damping and stiffness rotordynamic coefficients. Adding a swirl brake to the damping seal greatly reduces the destabilizing cross-coupled forces generated by the damping seal for even further increases in the stabilizing capacity. Marshall?s Annular Seal Test (MAST) rig is designed to experimentally measure the stabilizing capacity of new annular seal designs. The rig has been moved to a new facility and outfitted with a new slave bearing to allow increased test durations and to enable the testing of fluid film bearings. The purpose of this paper is to describe the new facility and the new bearing arrangement. Several novel seal and bearing designs will also be discussed.

Darden, J. M.↗

Measuring Polanyi Potentials for Chemsorb 1000 and Chemsorb 3800

Polanyi adsorption potential plots are used to predict the adsorptive capacities of volatile organic compounds onto activated carbons. The design and construction of a test rig for measuring equilibrium adsorption capacities suitable for constructing Polanyi adsorption potential plots for candidate sorbents suitable for use in ECLS systems is presented. The adsorptive capacities of Chemsorb(TradeMark) 1000 and Chemsorb(TradeMark) 800 for ethanol and acetone were measured. The capacities and Polanyi adsorption potential plots for these commercially-available sorbents were compared to that of Barnebey Sutcliffe Type 3032, an acid-impregnated activated carbon utilized aboard the International Space Station.

Chemsorb 3800↗

Rapid Cycle Amine 4.0 System Development

Carbon dioxide (CO2) and humidity control is a key function of the spacesuit Portable Life Support Subsystem (PLSS). The latest spacesuit design utilizes a pressure swing bed containing a solid amine sorbent to scrub CO2 and humidity produced by the crewmember from the ventilation loop. The solid amine sorbent removes CO2 and humidity from the ventilation loop through a chemisorption mechanism. Simultaneously, CO2 and humidity are desorbed to vacuum via the two-bed pressure swing system during operation. This continuous regeneration allows for longer Extravehicular Activity (EVA) times while minimizing maintenance, consumables, and power usage. This concept has been in development for over 20 years, during which many prototypes and design iterations have been fabricated and evaluated. This paper discusses the recent Rapid Cycle Amine (RCA) design, development, and testing that has been done to advance the technology. The most recent fabrication is the RCA 3.0. It was delivered to NASA Johnson Space Center in 2015 and has since been tested at the component level and at the integrated PLSS level. The purpose of the component level testing was to understand CO2 removal capacity, end-of-life performance, and establish a baseline performance prior to integrated testing. The RCA 3.0 was integrated into the Exploration Extravehicular Mobility Unit (xEMU) PLSS for a comprehensive Design Verification Test (DVT) series. The integrated testing provided the benefit of characterizing the impact performance degradation has on the system. Many of the RCA requirements were developed through analysis, based on the limitations of the PLSS and, in some cases, assumptions about the system and flow behavior. Integrated testing was an opportunity to validate those requirements and assumptions. While the RCA 3.0 was being tested, the next design iteration, RCA 4.0, was under development. The RCA 4.0 preliminary design phase began in late-2019 and shortly after the Preliminary Design Review, the critical design phase began in 2021. The design work has concluded with the completion of a Pre-Manufacturing Review in 2022. This paper provides an overview of the RCA 4.0 system design, summarizes the results of integrated RCA 3.0 testing, and discusses the pertinence of driving requirements such as mass, volume, and power consumption.

Kelsey Bloom↗

The monogroove high performance heat pipe

The development of the monogroove heat pipe, a fundamentally new high-performance device suitable for multi-kilowatt space radiator heat-rejection systems, is reported. The design separates heat transport and transfer functions, so that each can be separately optimized to yield heat transport capacities on the order of 25 kW/m. Test versions of the device have proven the concept of heat transport capacity control by pore dimensions and the permeability of the circumferential wall wick structure, which together render it insensitive to tilt. All cases tested were for localized, top-side heat input and cooling and produced results close to theoretical predictions.

Alario, J.↗

Initial evaluation tests of Eagle-Picher Industries 9.0 ampere-hour nickel-cadmium spacecraft cells for the heat capacity mapping mission satellite and the stratospheric aerosol and gas experiment satellite

The results of tests to insure that all cells put into the life cycle program are of high quality are reported. The tests consisted of the following: phenolptalein leak tests, internal short test, charge efficiency test, and overcharge tests. The results of tests for 10 cells are tabulated.

Harkness, J. D.↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly Precipitation Prevention Project for the International Space Station

In support of the Urine Processor Assembly Precipitation Prevention Project (UPA PPP), multiple technologies were explored to prevent CaSO4 dot 2H2O (gypsum) precipitation during the on-orbit distillation process. Gypsum precipitation currently limits the water recovery rate onboard the International Space Station (ISS) to 70% versus the planned 85% target water recovery rate. Due to its advanced performance in removing calcium cations in pretreated augmented urine (PTAU), ion exchange was selected as one of the technologies for further development by the PPP team. A total of 12 ion exchange resins were evaluated in various equilibrium and dynamic column tests with solutions of dissolved gypsum, urine ersatz, PTAU, and PTAU brine at 85% water recovery. While initial evaluations indicated that the Purolite SST60 resin had the highest calcium capacity in PTAU (0.30 meq/mL average), later tests showed that the Dowex G26 and Amberlite FPC12H resins had the highest capacity (0.5 meq/mL average). Further dynamic column testing proved that G26 performance is +/- 10% of that value at flow rates of 0.45 and 0.79 Lph under continuous flow, and 10.45 Lph under pulsed flow. Testing at the Marshall Spaceflight Center (MSFC) integrates the ion exchange technology with a UPA ground article under flight-like pulsed flow conditions with PTAU. To date, no gypsum precipitation has taken place in any of the initial evaluations.

Mitchell, Julie L.↗

A survey of thermocouple anomalies: mechanisms, interpretation, and mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

thermocouple anomalies↗

Electromagnetic Thermocouple (TC) Anomaly Mechanisms During Atmospheric Entry

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including Thermal Protection Systems (TPS) for atmospheric entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, and heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, etc.). Consequently, accurate TC measurements are fundamental for both material and facility Verification and Validation (V&V). However, a number of electromagnetic TC anomalies have been observed in both ground tests and flight instrumentations. These anomalies are caused via various coupling mechanisms: surface voltage coupling, Hall effect currents, and RF rectification. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This talk will provide an overview of each of these anomaly mechanisms and discuss ongoing efforts to quantify and mitigate them.

Magnus Haw↗

A Survey of Thermocouple Anomalies: Mechanisms, Interpretation, and Mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

Thermocouple Anomalies↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

Hall, S. W.↗

Low temperature performance of lithium/silver vanadium oxide cells

Lithium/silver vanadium oxide cells for low temperature applications have been developed. Prismatic and spirally wound AA cells were tested under constant load discharge of 0.3 to 1.8 amps or pulse discharge of 0.225 or 1.0 amps at temperatures from -40 to 25 C. At -40 C with current densities of 2.5 mA/cm2, 23 percent of theoretical capacity was achieved under constant load discharge and 40 percent of theoretical capacity was achieved under pulse test. Self-discharge estimates of 0.7 percent per year at 25 C were obtained from microcalorimetry. Preliminary safety testing of the cells revealed no violent performance under short circuit or crush tests.

Takeuchi, E. S.↗

Bipropellant shut-off valve

An advanced design of an all metal, fast response, bipropellant, shut-off valve for use on long duration space missions is reported. The valve provides the flow control capability for a 1,000 lb thrust, bipropellant engine using oxygen difluoride and diborane as propellants. The shutoff seal selection is a soft-on-hard metal concept. The soft seal is a spherical shell that seats against a hard conical seat. Beryllium copper and beryllium nickel seals were selected to seal against an electrolyzed Inconel 718 seat. Poppet shaft sealing is achieved by use of hydroformed, Inconel 718 bellows. Two valve assemblies were fabricated and subjected to a series of tests including leak, response time, flow capacity, dry cycles, water cycles, liquid nitrogen cycles, liquid fluorine cycles, and lead-lag operation cycles. These tests demonstrated the ability of the valve to meet design goals.

Smith, J. V.↗

Plasma viscosity elevations with simulated weightlessness

A hypothesis correlating an increase in blood viscosity during bed rest to a decrease in aerobic capacity during simulated weightlessness is tested. Eight human subjects were studied on the sixth day of bed rest during two consecutive 10-d bed rest periods separated by a 14-d recovery interval designed to simulate the flight-layover schedule of Shuttle astronauts. Plasma viscosity and volume were measured, together with maximal aerobic capacity (VO2max). An increase in hematocrit, plasma protein, and fibrinogen concentrations was found, contributing to an elevation in plasma viscosity. VO2max decreased significantly in the first, but not the second bed rest cycle, and though many individuals exhibited a decrease in plasma volume and aerobic capacity coupled with elevated plasma viscosity, correlations between these variables were lacking. It is concluded that the decrease in VO2max observed following simulated weightlessness cannot be attributed to alterations in muscle blood flow resulting from increased blood viscosity.

Martin, D. G.↗