At least 199 records · Page 11

Carbon Dioxide Sealing Capacity: Textural or Compositional Controls? (Final Scientific/Technical Report)

This research project is aiming to assess the carbon dioxide sealing capacity of most common seal-rocks, such as shales and non-fractured limestones, by analyzing the role of textural and compositional parameters of those rocks. We hypothesize that sealing capacity is controlled by textural and/or compositional parameters of caprocks. In this research, we seek to evaluate the importance of textural and compositional parameters affecting the sealing capacity of caprocks. The conceptual framework involves two testable end-member hypotheses concerning the sealing capacity of carbon dioxide reservoir caprocks. Better understanding of the elements controlling sealing quality will advance our knowledge regarding the sealing capacity of shales and carbonates. Due to relatively low permeability, shale and non-fractured carbonate units are considered relatively impermeable formations which can retard reservoir fluid flow by forming high capillary pressure. Similarly, these unites can constitute reliable seals for carbon dioxide capture and sequestration purposes. This project is a part of the comprehensive project with the final aim of studying the caprock sealing properties and the relationship between microscopic and macroscopic characteristics of seal rocks in depleted gas fields of Oklahoma Panhandle. Through this study we examined various seal rock characteristics to infer about their respective effects on sealing capacity in special case of replacing reservoir fluid with super critical carbon dioxide (scCO 2 ). To assess the effect of textural and compositional properties on scCO 2 maximum retention column height we collected 30 representative core samples in caprock formations in three counties (Cimarron, Texas, Beaver) in Oklahoma Panhandle. Core samples were collected from various seal formations (e.g., Cherokee, Keys, Morrowan) at different depths. We studied the compositional and textural properties of the core samples using several techniques. Mercury Injection Porosimetry (MIP), Scanning Electron Microscopy SEM, and Sedigraph measurements are used to assess the pore-throat-size distribution, sorting, texture, and grain size of the samples. Also, displacement pressure at 10% mercury saturation (Pd) and graphically derived threshold pressure (P c ) were determined by MIP technique. SEM images were used for qualitative study of the minerals and pores texture of the core samples. Moreover, EDS (Energy Dispersive X-Ray Spectrometer), BET specific surface area, and Total Organic Carbon (TOC) measurements were performed to study various parameters and their possible effects on sealing capacity of the samples. We found that shales have the relatively higher average sealing threshold pressure (P c ) than carbonate and sandstone samples. Based on these observations, shale formations could be considered as a promising caprock in terms of retarding scCO 2 flow and leakage into above formations. We hypothesized that certain characteristics of shales (e.g., 3 fine pore size, pore size distribution, high specific surface area, and strong physical chemical interaction between wetting phase and mineral surface) make them an efficient caprock for sealing super critical CO 2 . We found that the displacement pressure at 10% mercury saturation could not be the ultimate representative of the sealing capacity of the rock sample. On the other hand, we believe that graphical method, introduced by Cranganu (2004) is a better indicator of the true sealing capacity. Based on statistical analysis of our samples from Oklahoma Panhandle we assessed the effects of each group of properties (textural and compositional) on maximum supercritical CO 2 height that can be hold by the caprock. We conclude that there is a relatively strong positive relationship (+.40 to +.69) between supercritical CO 2 column height based on P c and hard/ soft mineral content index (ratio of minerals with Mohs hardness more than 5 over minerals with Mohs hardness less than 5) in both shales and limestone samples. Average median pore radius and porosity display a strong negative correlation with supercritical CO 2 retention column height. Also, increasing bulk density is positively correlated with the supercritical CO 2 retention column height. One of the most important factors affecting sealing capacity and consequently the height of supercritical CO 2 column is sorting of the pore throats. We observed a strong positive correlation between pore throat sorting and height of CO 2 retention column, especially in shales. This correlation could not be observed in limestone samples. It suggests that the pore throat sorting is more controlling the sealing capacity in shales and shales with well sorted pore throats are the most reliable lithology as seal. We observed that Brunauer–Emmett–Teller (BET) surface area shows a very strong correlation with CO 2 retention column height in limestone samples while BET surface area did not display significant correlation in shales. Pore structure based on SEM micrographs exhibits strong correlation with CO 2 retention column height in limestones. Both intercrystalline and vuggy structures have negative correlations while intergranular texture has positive correlation in limestone with respect to CO 2 retention column height. Textural effects observed on SEM micrographs did not show statistically significant correlation with supercritical CO 2 retention column height in shale samples. Finally, we showed that increasing hard/soft mineral index is strongly correlated with the displacement pressure in limestone samples. Vuggy texture displays a relatively strong and negative correlation with displacement pressure values at 10% mercury saturation in shale samples.

54 ENVIRONMENTAL SCIENCES↗

Nickel-hydrogen capacity loss on storage

Nickel-hydrogen batteries are rapidly becoming accepted for use in low-earth-orbit and geosynchronous orbit applications. With their increased use it has become evident that the storage procedures commonly used for nickel-cadmium cells are not adequate for the nickel-hydrogen system. The capacity loss exhibited by nickel electrodes from various manufacturers when exposed to different storage conditions was determined. A comprehensive test matrix was developed to evaluate capacity loss in nickel electrodes from four different manufacturers. Two types of tests were run; individual electrode tests, which involved flooded capacity and impedance measurements before and after storage under varied conditions of temperature, hydrogen pressure, and electrolyte concentration; and cell tests which primarily evaluated the effects of state-of-charge on storage. The cell tests evaluated capacity loss on cells stored open circuit, shorted and trickle charged at C/100 following a full charge. The results indicate that capacity loss varies with the specific electrode manufacturing process, storage temperature and hydrogen pressure. In general, electrodes stored at low temperatures or low hydrogen pressures exhibited a smaller loss in capacity over the twenty-eight day storage period than those stored at high pressure and high temperature. The capacity loss appears to correlate with the level of cobalt in the nickel electrode, with the most significant loss of capacity occurring in electrodes with higher cobalt levels. Impedance measurements appear to correlate well with the capacity loss observed for a given type of electrode but do not correlate well with the capacity loss between electrodes fabricated by different manufacturers. There was a definite correlation between the electrode potential measured immediately following storage and the measured capacity loss.

Manzo, Michelle A.↗

Temperature control to reduce capacity mismatch in parallel-connected lithium ion cells

The temperature and capacity of individual cells affect the current distribution in a battery pack. Non uniform current distribution among parallel-connected cells can lead to capacity imbalance and premature aging. This paper develops models that calculate the current in parallel-connected cells and predict their capacity fade. The model is validated experimentally for a nonuniform battery pack at different temperatures. The paper also proposes and validates the hypothesis that temperature control can reduce capacity mismatch in parallel-connected cells. Three Lithium Iron Phosphate cells, two cells at higher initial capacity than the third cell, are connected in parallel. The pack is cycled for 1500 Hybrid Electric Vehicles cycles with the higher capacity cells regulated at 40 C and the lower capacity cell at 20 C. As predicted by the model, the higher capacity and temperature cells age faster, reducing the capacity mismatch by 48% over the 1500 cycles. A case study shows that cooling of low capacity cells can reduce capacity mismatch and extend pack life.

25 ENERGY STORAGE↗

Estimating the supply and demand for deep geologic CO2 storage capacity over the course of the 21st Century: A meta-analysis of the literature

Whether there is sufficient geologic CO2 storage capacity to allow CCS to play a significant role in mitigating climate change has been the subject of debate since the 1990s. This paper presents a meta- analysis of a large body of recently published literature to derive updated estimates of the global deep geologic storage resource as well as the potential demand for this geologic CO2 storage resource over the course of this century. This analysis reveals that, for greenhouse gas emissions mitigation scenarios that have end-of-century atmospheric CO2 concentrations of between 350 ppmv and 725 ppmv, the average demand for deep geologic CO2 storage over the course of this century is between 410 GtCO2 and 1,670 GtCO2. The literature summarized here suggests that -- depending on the stringency of criteria applied to calculate storage capacity – global geologic CO2 storage capacity could be: 35,300 GtCO2 of “theoretical” capacity; 13,500 GtCO2 of “effective” capacity; 3,900 GtCO2, of “practical” capacity; and 290 GtCO2 of “matched” capacity for the few regions where this narrow definition of capacity has been calculated. The cumulative demand for geologic CO2 storage is likely quite small compared to global estimates of the deep geologic CO2 storage capacity, and therefore, a “lack” of deep geologic CO2 storage capacity is unlikely to be an impediment for the commercial adoption of CCS technologies in this century.

climate change mitigation↗

Enhancing the Electrode Gravimetric Capacity of Li 1.2 Mn 0.4 Ti 0.4 O 2 Cathode Using Interfacial Carbon Deposition and Carbon Nanotube-Mediated Electrical Percolation

Mn-based cation disordered rocksalt oxides (Mn-DRX) are emerging as promising cathode materials for next-generation Li-ion batteries due to their high specific capacities and cobalt and nickel free characteristic. However, to reach the theoretical capacity, solid-state method synthesized Mn-DRX materials require activation via post-synthetic ball milling, typically incorporating more than 20 wt.% conductive carbon that adversely reduces the electrode level gravimetric capacity. To solve this issue, we firstly deposit amorphous carbon on the surface of the Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO) particles to increase the electrical conductivity by a five order of magnitude. Although the cathode material gravimetric first charge capacity reaches 180 mAh/g, its highly irreversible behavior leads to a 70 mAh/g first discharge capacity. Subsequently, to ensure a good electrical percolation network, the LMTO material is ball milled with multi-wall carbon nanotube (CNT) to obtain a 78.7 wt.% LMTO active material loading in the cathode electrode (LMTO-CNT). As a result, a 210 mAh/g cathode electrode gravimetric first charge and 165 mAh/g first discharge capacity are obtained, compared to the respective capacity values of 222 mAh/g and 155 mAh/g for the LMTO ball milled with 20 wt.% SuperP C65 electrode (LMTO-SP). After 50 cycles, the LMTO-CNT delivers a 121 mAh/g electrode gravimetric discharge capacity, largely outperforming the 44 mAh/g value of the LMTO-SP. In conclusion, our study demonstrates that while ball milling is necessary to achieve the theoretical capacity of LMTO, a careful selection of the additive, such as CNT, effectively reduces the required carbon quantity to achieve a higher electrode gravimetric discharge capacity.

25 ENERGY STORAGE↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies. Draft

There exist several different reliability- and approximation-based methods to determine the capacity contribution of solar resources towards resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this article we study the effect of time resolution and solar PV penetration using a capacity planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity factor based on time-series data can yield relatively accurate results for small penetration levels (less than 5%). For higher penetration levels (up to 20%), the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV. Although our results are not general, they highlight the importance of accounting for the variation in both energy and capacity value of solar resources endogenously in capacity planning models. A11 numerical experiments are performed using the IEEE Reliability Test System and 7 years worth of demand and solar data from a utility in Arizona.

14 SOLAR ENERGY↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Predicting Li-Ion Battery Capacity Fade Using Early-Life Data and a Hybrid Data-Driven Gaussian Process-Bayesian Regression Approach

Accurately predicting Li-ion battery capacity trajectories using early-life data can dramatically improve battery-life understandings and be used to rapidly evaluate design/cost/performance trade-offs when developing new battery materials. Accurate early-life predictions enable researchers to quickly iterate over cell designs and material precursor properties without consistently cycling cells to failure. To this end, we present a toolbox that uses a combined Gaussian Process and Bayesian regression approach that capitalizes on signals other than just capacity (e.g., dQ/dV, voltage drops) to rapidly predict capacity-fade trajectories. The prediction tool uses Bayesian regression to fit functional forms, e.g., power law, sigmoids, etc., to predict capacity-fade dynamics. By fitting functional forms, the capacity fade can be interrogated at any point in the future, allowing for early cell-failure prediction. Additionally, Bayesian regression allows for accurate uncertainty estimates that account for cell-to-cell variability (aleatoric uncertainty) and the lack of observation data (epistemic uncertainty). By only using early cycle data to predict the capacity fade trajectory, uncertainty bounds at end-of-life can be extremely large. The large uncertainty bounds are further exacerbated because there is no systematic way to define the prior distribution of the functional forms' parameters. We improve our the predicted trajectory confidence interval of our predicted trajectory using two methods. First, we shows that a small amount of held-out cycling data is sufficientuse some train cells, that have been cycled to failure to derive information regarding the appropriate prior distributions for the functional forms' parameters of the functional form, effectively leading to data-driven priors.. We propose constructing the data-driven priors by first running a Bayesian regression starting with uninformed priors to generate intermediate cell-specific posterior parameter distributions. These posterior distributions are combined using a Ggaussian mixture model for each parameter to create the data-driven priors. These mixture models serve as the data-driven prior distributions for the parameters for. Second, we derive multiple features, e.g., C_dchg 0.5 DoD 0.5, log (|mean(dQ/dV_(w_3-w_0 ) (V)|), etc., from the train cellsheld-out cycling data, identify which the features are that best predicting capacity at early/mid-life cycles, and then create Ggaussian process regression models that are used for predicting capacity at early/mid-life cycles for the test cells (see blue dots with error bars in Fig 1b). Finally, these predicted data-points are used in addition to the actual early cycle data capacity fade to construct the Bayesian regression trajectory for the test cell s. Notably. We note that these two methods are complementary and can be combined with each other. We evaluate the performance of our proposed method on an testing open-source dataset from Iowa State University and Iowa Lakes Community College (ISU-ILCC). This dataset comprises of 251 nickel-manganese-cobalt/graphite Lithium-ion cells that are cycled under 63 different conditions. We compute the mean average percentage error (MAPE) and negative log predictive density (NLPD) to quantify the efficacy of our method. Our initial findings suggest that, when only few observations are available, for test cells, when using only Bayesian regression with uninformed priors, a power law functional provides the most accurate predictions. with very few data points. However, asHowever, a the number of data points increases, a twin sigmoidal function becomes more accurate as the number of observations further increases. We also find that using as little as 10% of the data set towards generating data-driven priors can lead to significant improvement in prediction accuracy when using early cycle data. Lastly, we found that augmenting early-cycle data with Gaussian process-predicted capacity data for Bayesian regression greatly improves the prediction accuracy. We will present a comprehensive comparison of our methods to other methods available in the literature and apply this method to additional battery datasets.

42 ENGINEERING↗

Hydropower Energy Storage Capacity (HESC) Dataset

The Hydropower Energy Storage Capacity (HESC) Dataset catalogs characteristics that are relevant to evaluating reservoir storage and estimates of energy storage capacity based on varying levels of detail. Hydropower dams and reservoirs were included based on information from the National Inventory of Dams (NID; USACE, 2021) and Global Reservoir and Dam (GRanD v1.3) and Existing Hydropower Assets datasets. These data provide a foundation for understanding available resources at existing hydropower facilities and their potential to provide storage of energy and more flexible generation. Estimates of energy storage capacity include: • Level 1 – nominal energy storage capacity based on maximum storage capacities and hydraulic head • Level 2 – nominal energy storage capacity based on historical models or observations of reservoir volume and hydraulic head. These estimates are provided based on capacity from the entire historical period as well as monthly values. • Level 3 – modeled energy generation based on volume-elevation relationships, historical storage, observed/modeled inflows, and hydraulic capacity of turbines and calculated both as overall and on a monthly basis. • Level 4 – modeled energy generation incorporating information from Level 3 and operational constraints. For facilities where installed capacity is known, there are also estimates for discharge duration (the length of time when a facility could provide generation at a given capacity).

13 HYDRO ENERGY↗

Turbine scale and siting considerations in wind plant layout optimization and implications for capacity density

Improvements in wind energy technology, reduced costs, and ambitious clean energy goals have led to projections of high wind contribution in coming years. Developing methodologies to design wind plants with a variety of siting constraints and turbine sizes helps enable high wind penetration, and gain a better understanding of how wind plants are sensitive to setback constraints and turbine design. In this paper, we present a two-step optimization method to simultaneously determine the optimal number of turbines and their locations in a wind plant domain divided into many small, discrete parcels. We present the optimized performance metrics of a wind plant optimized with different turbine sizes and ratings, and with different siting restrictions within the wind plant. Our results indicate that taller and larger turbines are more sensitive to increasing siting constraints. We also compare the optimal wind plant layouts and performance for wind plants optimized for minimum COE and maximum profit. Wind plants optimized for profit had 130%-190% of the capacity of plants optimized for COE, which demonstrates that the optimal results are greatly affected by the objective function, which should be carefully considered. Finally, in this paper we demonstrate the effect of increasing siting constraints on wind plant capacity density, and how the results change when different land areas are used to calculate capacity density. When using the entire wind plant boundary area to determine capacity density, increasing siting constraints decreases the capacity density. However, when we only use the available area (the area left after removing the siting constraints) to calculate the capacity density, increasing the siting constraints increases capacity density. This is a critical insight because of how capacity density is typically defined and used in research, and has important implications for assessment of technical potential and capacity expansion modeling, as well as future wind deployment potential.

17 WIND ENERGY↗

A Hierarchical Framework for CO2 Storage Capacity in Deep Saline Aquifer Formations

Carbon dioxide (CO 2 ) storage in deep saline aquifers is a vital option for CO 2 mitigation at a large scale. Determining storage capacity is one of the crucial steps toward large-scale deployment of CO 2 storage. Results of capacity assessments tend toward a consensus that sufficient resources are available in saline aquifers in many parts of the world. However, current CO 2 capacity assessments involve significant inconsistencies and uncertainties caused by various technical assumptions, storage mechanisms considered, algorithms, and data types and resolutions. Furthermore, other constraint factors (such as techno-economic features, site suitability, risk, regulation, social-economic situation, and policies) significantly affect the storage capacity assessment results. Consequently, a consensus capacity classification system and assessment method should be capable of classifying the capacity type or even more related uncertainties. We present a hierarchical framework of CO 2 capacity to define the capacity types based on the various factors, algorithms, and datasets. Finally, a review of onshore CO 2 aquifer storage capacity assessments in China is presented as examples to illustrate the feasibility of the proposed hierarchical framework.

58 GEOSCIENCES↗

Summary Analysis of Different Offshore Wind Capacity Density Drivers in Proposed U.S. Projects and Impacts on Progress Towards State and Federal Deployment Targets

Understanding the density of offshore wind development - or the "capacity density" - is important for state and federal offshore wind planning efforts and to track progress towards policy goals. NREL has traditionally assumed a capacity density of 3 megawatts per square kilometer (MW/km2) when estimating the U.S. project pipeline (Musial et al. 2022), but capacity densities for existing European offshore wind farms ranged from 2-19 MW/km2 (Borrmann et al. 2018). We track the expected capacity densities of the proposed U.S. projects in the East Coast and make an analysis by state and by developer to identify what are the capacity density norms in the industry and whether the state in which the development efforts are taking place has some impact on capacity density. We also analyze the effects of the area occupied by station keeping systems on capacity density for lease areas dedicated to floating projects and provide a list of main capacity density drivers. This summary analysis sets a baseline to study how different capacity density drivers could impact the progress towards state and federal deployment targets. Given the currently delineated Renewable Energy Areas in the Outer Continental Shelf (OCS) and the basis from the summary analysis, we estimate the expected offshore wind deployment over time federally and by state and compare it to the state and federal deployment targets. The proposed analysis helps identify gaps and needs to meet state and federal targets, which provides sufficient information to propose strategic supply chain and policy planning with the objective of meeting deployment goals.

capacity density↗

Quantum-capacity-approaching codes for the detected-jump channel

The quantum-channel capacity gives the ultimate limit for the rate at which quantum data can be reliably transmitted through a noisy quantum channel. Degradable quantum channels are among the few channels whose quantum capacities are known. Given the quantum capacity of a degradable channel, it remains challenging to find a practical coding scheme which approaches capacity. Here we discuss code designs for the detected-jump channel, a degradable channel with practical relevance describing the physics of spontaneous decay of atoms with detected photon emission. We show that this channel can be used to simulate a binary classical channel with both erasures and bit flips. The capacity of the simulated classical channel gives a lower bound on the quantum capacity of the detected-jump channel. When the jump probability is small, it almost equals the quantum capacity. Hence using a classical capacity-approaching code for the simulated classical channel yields a quantum code which approaches the quantum capacity of the detected-jump channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Capacity of Pulse-Position Modulation (PPM) on Gaussian and Webb Channels

This article computes the capacity of various idealized soft-decision channels modeling an optical channel using an avalanche photodiode detector (APD) and pulse-position modulation (PPM). The capacity of this optical channel depends in a complicated way on the physical parameters of the APD and the constraints imposed by the PPM orthogonal signaling set. This article attempts to identify and separate the effects of several fundamental parameters on the capacity of the APD-detected optical PPM channel. First, an overall signal-to-noise ratio (SNR) parameter is de ned such that the capacity as a function of a bit-normalized version of this SNR drops precipitously toward zero at quasi-brick-wall limits on bit SNR that are numerically the same as the well-understood brick-wall limits for the standard additive white Gaussian noise (AWGN) channel. A second parameter is used to quantify the effects on capacity of one unique facet of the optical PPM channel (as compared with the standard AWGN channel) that causes the noise variance to be higher in signal slots than in nonsignal slots. This nonuniform noise variance yields interesting capacity effects even when the channel model is AWGN. A third parameter is used to measure the effects on capacity of the difference between an AWGN model and a non-Gaussian model proposed by Webb (see reference in [2]) for approximating the statistics of the APD-detected optical channel. Finally, a fourth parameter is used to quantify the blending of a Webb model with a pure AWGN model to account for thermal noise. Numerical results show that the capacity of M-ary orthogonal signaling on the Webb channel exhibits the same brick-wall Shannon limit, (M ln 2)=(M 1), as on the AWGN channel ( 1:59 dB for large M). Results also compare the capacity obtained by hard- and soft-output channels and indicate that soft-output channels o er a 3-dB advantage.

Dolinar, S.↗

Comparison of Capacity Value Methods for Photovoltaics in the Western United States

This report compares different capacity value estimation techniques applied to solar photovoltaics (PV). It compares more robust data and computationally intense reliability-based capacity valuation techniques to simpler approximation techniques at 14 different locations in the western United States. The capacity values at these locations are computed while holding the underlying power system characteristics fixed. This allows the effect of differences in solar availability patterns on the capacity value of PV to be directly ascertained, without differences in the power system confounding the results. Finally, it examines the effects of different PV configurations, including varying the orientation of a fixed-axis system and installing single- and double-axis tracking systems, on the capacity value. The capacity value estimations are done over an eight-year running from 1998 to 2005, and both long-term average capacity values and interannual capacity value differences (due to interannual differences in solar resource availability) are estimated. Overall, under the assumptions used in the analysis, we find that some approximation techniques can yield similar results to reliability-based methods such as effective load carrying capability.

14 SOLAR ENERGY↗

Decoupling Accurate Electrochemical Behaviors for High-Capacity Electrodes via Reviving Three-Electrode Vehicles

Developing high-capacity electrodes requires the evaluation of electrochemical behaviors with an increasing current density. Currently, the current density for evaluation of high-capacity electrodes has reached a new stage where the polarization at the lithium counter electrode has become a technical barrier for the accurate evaluation of battery electrodes, resulting in severe performance and mechanism mischaracterizations. Here, the accurate electrochemical behavior for high-capacity electrodes via a single-channel three-electrode vehicle is decoupled, by which the impact of lithium counter electrode is minimized. The testing high-capacity graphite electrode is capable of delivering an excellent rate capability with 81.7% capacity retention at 0.3 C, as well as stable cycling performance retaining 97.5% practical reversible capacity after 225 cycles, much higher than the graphite electrode tested with traditional half-cell testing vehicle but in close agreement with the results obtained from a well-matched full cell, reflecting accurate electrochemical performance evaluations of high-capacity electrodes. Moreover, detailed electrochemical mechanisms of impedance and diffusion properties for working electrodes are also successfully decoupled individually. Here, this work uncovers the mismatch between traditional evaluation configuration and increasing testing current density and provides a guideline for accurate electrochemical evaluation for ever-increasing high-capacity electrodes, which is of great significance for high-energy lithium or other alkali-metal ion batteries.

25 ENERGY STORAGE↗

Potential and limitations of inferring ecosystem photosynthetic capacity from leaf functional traits

Abstract The aim of this study was to systematically analyze the potential and limitations of using plant functional trait observations from global databases versus in situ data to improve our understanding of vegetation impacts on ecosystem functional properties ( EFP s). Using ecosystem photosynthetic capacity as an example, we first provide an objective approach to derive robust EFP estimates from gross primary productivity ( GPP ) obtained from eddy covariance flux measurements. Second, we investigate the impact of synchronizing EFP s and plant functional traits in time and space to evaluate their relationships, and the extent to which we can benefit from global plant trait databases to explain the variability of ecosystem photosynthetic capacity. Finally, we identify a set of plant functional traits controlling ecosystem photosynthetic capacity at selected sites. Suitable estimates of the ecosystem photosynthetic capacity can be derived from light response curve of GPP responding to radiation (photosynthetically active radiation or absorbed photosynthetically active radiation). Although the effect of climate is minimized in these calculations, the estimates indicate substantial interannual variation of the photosynthetic capacity, even after removing site‐years with confounding factors like disturbance such as fire events. The relationships between foliar nitrogen concentration and ecosystem photosynthetic capacity are tighter when both of the measurements are synchronized in space and time. When using multiple plant traits simultaneously as predictors for ecosystem photosynthetic capacity variation, the combination of leaf carbon to nitrogen ratio with leaf phosphorus content explains the variance of ecosystem photosynthetic capacity best (adjusted R 2 = 0.55). Overall, this study provides an objective approach to identify links between leaf level traits and canopy level processes and highlights the relevance of the dynamic nature of ecosystems. Synchronizing measurements of eddy covariance fluxes and plant traits in time and space is shown to be highly relevant to better understand the importance of intra‐ and interspecific trait variation on ecosystem functioning.

54 ENVIRONMENTAL SCIENCES↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗