Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Slow speed object detection for haul trucks

Caterpillar integrates radar technology with its current camera based system. Caterpillar has developed the Integrated Object Detection System, a slow speed object detection system for mining haul trucks. Object detection is a system that aids the truck operator's awareness of their surroundings. The system consists of a color touch screen display along with medium- and short-range radar as well as cameras, harnesses and mounting hardware. It is integrated into the truck's Work Area Vision System (WAVS). After field testing in 2007, system commercialization began in 2008. Prototype systems are in operation in Australia, Utah and Arizona and the Integrated Object Detection System will be available in the fourth quarter of 2009 and on production trucks 785C, 789C, 793D and 797B. The article is adapted from a presentation by Mark Richards of Caterpillar to the Haulage & Loading 2009 conference, May, held in Phoenix, AZ. 1 fig., 5 photos.

01 COAL, LIGNITE, AND PEAT↗

Scientific system for high-resolution measurement of the circumsolar radiation

We developed a camera based system for measurements of the circumsolar radiation with a high angular resolution of 0.1 mrad. Subsequent measurements may be taken at intervals as short as 15 s. In this publication we describe the optical system in detail and discuss some aspects of the measurement method. First results from two days of measurement at Freiburg i. Br., Germany, are presented and compared to data from literature. The good results encourage us to perform longer measurement campaigns in future to better understand the influence of circumsolar radiation on the power yield of concentrating photovoltaic systems.

14 SOLAR ENERGY↗

WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns: static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was introduced.

60 APPLIED LIFE SCIENCES↗

PS-1/S1 picosecond streak camera application for multichannel laser system diagnostics

A PS-1/S1 picosecond image-tube streak camera (ITSC) with slit scan (streak camera), developed and manufactured at the General Physics Institute RAS, has been used to measure the spatiotemporal characteristics of ultrashort laser pulses generated by a petawatt-power laser installation 'FEMTO' at the Institute of Laser Physics Research in Sarov. It is found that such a camera is suitable for measuring the spatial and temporal parameters of single laser pulses with an accuracy of about one picosecond. It is shown that the intensity time profile of a train of picosecond pulses may be precisely defined for the pulses separated in time by a few picoseconds. The camera allows the contrast of radiation to be determined with a high (no less than 10{sup 3}) accuracy; spatial distribution of the laser pulses can be measured with an accuracy of tens of microns, and the temporal separation of single laser pulses can be identified with an accuracy of 1 – 1.5 ps. (extreme light fields and their applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV{sub MET}) and whole brain plus metastases (WB+PTV{sub MET}) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV{sub MET} structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV{sub MET} iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV{sub MET} delivery. But, film doses for PTV{sub MET} only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

60 APPLIED LIFE SCIENCES↗

Autonomous Radiation Survey Inside Contaminated Buildings at Fukushima Daiichi with the Riser UAV - 18299

Nuclear decommissioning is constrained and defined by radiation and radioactive contamination. Where radiation is high and its distribution is unknown simply gathering the data needed for project planning can become a challenge. Fukushima Daiichi epitomises this challenge. The complex sequence of events at the plant following the March 2011 earthquake and tsunami has resulted in extensive physical damage and an essentially unpredictable distribution of contamination. TEPCO have applied a range of manual and robotics techniques to map the status of the plant, but many significant areas have remained no-go zones due to a combination of high radiation, physical hazards and obstacles. Further, even in areas where manual survey is feasible, there is strong desire to minimise human exposure to radiation by deploying robots where possible. Riser is a fully autonomous UAV equipped with an infrastructure-free 3D navigation and mapping system, inspection cameras and a CZT spectrometric measurement capability. The system has been custom designed specifically to meet the needs of the nuclear inspection. Riser is capable of accessing areas with dose rates of hundreds of milli-sievert per hour and producing 3D models and radiation surveys with accurately located data points. The data from Riser can subsequently be fused using Createc's N-Visage engine to produce three-dimensional contamination maps which can be used for predictive modelling of future D and D activity. Riser has been deployed at Fukushima Daiichi since March 2017. We present examples of data and analysis outputs, as well as general learning about deploying autonomous robots at a nuclear site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cooling the Dark Energy Camera CCD Array using a Closed-Loop, Two-Phase Liquid Nitrogen system

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO. This instrument is a 3 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k x 4k CCDs and 12 2k x 2k CCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. The DECam CCD array is inside the imager vessel. The focal plate is cooled using a closed loop liquid nitrogen system. As part of the development of the mechanical and cooling design, a full scale prototype imager vessel has been constructed and is now being used for Multi-CCD readout tests. The cryogenic cooling system and thermal controls are described along with cooling results from the prototype camera. The cooling system layout on the Blanco telescope in Chile is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The US Support Program to IAEA Safeguards Priority of Containment and Surveillance

The United States Support Program (USSP) priority for containment and surveillance (US) focuses on maintaining or improving the reliability and cost-effectiveness of C/S systems for IAEA safeguards, expanding the number of systems that are unattended and remotely monitored, and developing verification methods that help streamline the on-site inspection process. Existing IAEA C/S systems have evolved to become complex, integrated systems, which may include active seals, nondestructive assay (NDA) instruments, video cameras, and other sensors. These systems operate autonomously. They send analytical data to IAEA headquarters where it can be reviewed. These systems present challenges to the goals of improved system performance, standardization, reliability, maintainability, documentation, and cost effectiveness. One critical lesson from past experiences is the need for cooperation and common objectives among the IAEA, the developer, and the facility operator, to create a successful, cost effective system. Recent USSP C/S activities include Rokkasho Reprocessing Plant safeguard systems, production of a new shift register, numerous vulnerability assessments of C/S systems, a conduit monitoring system which identifies tampering of IAEA conduit deployed in the field, fiber optic seal upgrades, unattended monitoring system software upgrades, next generation surveillance system which will upgrade existing camera systems, and support of the IAEA's development of the universal nondestructive assay data acquisition platform.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and one is able to write complex 3D (three-dimensional) structures. An illumination system and CMOS camera enables online process monitoring. Control of all equipment is automated via custom made computer software ''3D-Poli'' specially designed for LTPP applications. Structures can be imported from computer aided design STereoLihography (stl) files or programmed directly. It can be used for rapid LTPP structuring in various photopolymers (SZ2080, AKRE19, PEG-DA-258) which are known to be suitable for bio-applications. Microstructured scaffolds can be produced on different substrates like glass, plastic and metal. In this paper, we present microfabricated polymeric scaffolds over a large area and growing of adult rabbit myogenic stem cells on them. Obtained results show the polymeric scaffolds to be applicable for cell growth practice. It exhibit potential to use it for artificial pericardium in the experimental model in the future.

36 MATERIALS SCIENCE↗

SU-D-BRA-01: Feasibility Study for Swallowing Prediction Using Pressure Sensors

Purpose: To develop a swallowing prediction system (SPS) using force sensing sensors and evaluate its feasibility. Methods: The SPS developed consists of force sensing sensor units, a thermoplastic mask, a signal transport device and a control PC installed with an in-house software. The SPS is designed to predict the pharyngeal stage of swallowing because it is known that internal organ movement occurs in pharyngeal stage. To detect prediction signal in the SPS, the force sensing sensor units were attached on both the submental muscle region and thyroid cartilage region of the thermoplastic mask. While the signal from the thyroid cartilage region informs the action of swallowing, the signal from the submental muscle region is utilized as a precursor for swallowing. Since the duration of swallowing is relatively short, using such precursor (or warning) signals for machine control is considered more beneficial. A volunteer study was conducted to evaluate the feasibility of the system. In this volunteer study, we intended to verify that the system could predict the pharyngeal stage of the swallowing. We measured time gaps between obtaining the warning signals in the SPS and starting points of the pharyngeal stage of swallowing. Results: The measured data was examined whether the time gaps were in reasonable order to be easily utilized. The mean and standard deviation values of these time gaps were 0.550 s ± 0.183 s. in 8 volunteers. Conclusion: The proposed method was able to predict the on-set of swallowing of human subjects inside the thermoplastic mask, which has never been possible with other monitoring systems such as camera-based monitoring system. With the prediction ability of swallowing incorporated into the machine control mechanism (in the future), beam delivery can be controlled to skip swallowing periods and significant dosimetric gain is expected in head & neck cancer treatments. This work was supported by the Radiation Technology R&D program (No. 2015M2A2A7038291) and by the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

The Physics of the Accelerating Universe Camera

The Physics of the Accelerating Universe (PAU) Survey goal is to obtain photometric redshifts (photo-z) and spectral energy distributions (SEDs) of astronomical objects with a resolution roughly one order of magnitude better than current broadband (BB) photometric surveys. To accomplish this, a new large field-of-view (FoV) camera (PAUCam) has been designed, built, and commissioned and is now operated at the William Herschel Telescope (WHT). With the current WHT prime focus corrector, the camera covers an ∼1° diameter FoV, of which only the inner ∼40′ diameter is unvignetted. The focal plane consists of a mosaic of 18 2k × 4k Hamamatsu fully depleted CCDs, with high quantum efficiency up to 1 μm in wavelength. To maximize the detector coverage within the FoV, filters are placed in front of the CCDs inside the camera cryostat (made out of carbon fiber) using a challenging movable tray system. The camera uses a set of 40 narrowband filters ranging from ∼4500 to ∼8500 Å complemented with six standard BB filters, ugrizY. The PAU Survey aims to cover roughly 100 deg{sup 2} over fields with existing deep photometry and galaxy shapes to obtain accurate photometric redshifts for galaxies down to i {sub AB} ∼ 22.5, also detecting galaxies down to i {sub AB} ∼ 24 with less precision in redshift. With this data set, we will be able to measure intrinsic alignments and galaxy clustering and perform galaxy evolution studies in a new range of densities and redshifts. Here we describe the PAU camera, its first commissioning results, and its performance.

79 ASTRONOMY AND ASTROPHYSICS↗