Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Case Study Using Modeling and Simulation to Predict Logistics Supply Chain Issues

Optimization of critical supply chains to deliver thousands of parts, materials, sub-assemblies, and vehicle structures as needed is vital to the success of the Constellation Program. Thorough analysis needs to be performed on the integrated supply chain processes to plan, source, make, deliver, and return critical items efficiently. Process modeling provides simulation technology-based, predictive solutions for supply chain problems which enable decision makers to reduce costs, accelerate cycle time and improve business performance. For example, United Space Alliance, LLC utilized this approach in late 2006 to build simulation models that recreated shuttle orbiter thruster failures and predicted the potential impact of thruster removals on logistics spare assets. The main objective was the early identification of possible problems in providing thruster spares for the remainder of the Shuttle Flight Manifest. After extensive analysis the model results were used to quantify potential problems and led to improvement actions in the supply chain. Similarly the proper modeling and analysis of Constellation parts, materials, operations, and information flows will help ensure the efficiency of the critical logistics supply chains and the overall success of the program.

Tucker, David A.↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stellar and weak lensing profiles of massive galaxies in the Hyper-Suprime Cam survey and in hydrodynamic simulations

ABSTRACT We perform a consistent comparison of the mass and mass profiles of massive (M⋆ > 1011.4 M⊙) central galaxies at z ∼ 0.4 from deep Hyper Suprime-Cam (HSC) observations and from the Illustris, TNG100, and Ponos simulations. Weak lensing measurements from HSC enable measurements at fixed halo mass and provide constraints on the strength and impact of feedback at different halo mass scales. We compare the stellar mass function (SMF) and the Stellar-to-Halo Mass Relation (SHMR) at various radii and show that the radius at which the comparison is performed is important. In general, Illustris and TNG100 display steeper values of α where $M_{\star } \propto M_{\rm vir}^{\alpha }$. These differences are more pronounced for Illustris than for TNG100 and in the inner rather than outer regions of galaxies. Differences in the inner regions may suggest that TNG100 is too efficient at quenching in situ star formation at Mvir ≃ 1013 M⊙ but not efficient enough at Mvir ≃ 1014 M⊙. The outer stellar masses are in excellent agreement with our observations at Mvir ≃ 1013 M⊙, but both Illustris and TNG100 display excess outer mass as Mvir ≃ 1014 M⊙ (by ∼0.25 and ∼0.12 dex, respectively). We argue that reducing stellar growth at early times in $M_\star \sim 10^{9-10} \, \mathrm{M}_{\odot }$ galaxies would help to prevent excess ex-situ growth at this mass scale. The Ponos simulations do not implement AGN feedback and display an excess mass of ∼0.5 dex at r < 30 kpc compared to HSC which is indicative of overcooling and excess star formation in the central regions. The comparison of the inner profiles of Ponos and HSC suggests that the physical scale over which the central AGN limits star formation is r ≲ 20 kpc. Joint comparisons between weak lensing and galaxy stellar profiles are a direct test of whether simulations build and deposit galaxy mass in the correct dark matter haloes and thereby provide powerful constraints on the physics of feedback and galaxy growth. Our galaxy and weak lensing profiles are publicly available to facilitate comparisons with other simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Discomfort glare with complex fenestration systems and the impact on energy use when using daylighting control

Glare is a frequent issue in highly glazed buildings. A modelling approach is presented that uses discomfort glare probability and discomfort glare index as metrics to determine occupants’ behaviour. A glare control algorithm that actuated an interior shade for glare protection based on the predicted perception was implemented in a building simulation program. A reference case with a state-of-the-art base glazing was compared to the same glazing but with five different complex fenestration systems, i.e., exterior shades. The windows with exterior shades showed significant variations in glare frequencies. Energy use intensity in a prototypical office building with daylighting controls was greatly influenced for the systems with frequent glare occurrence. While the base glazing could benefit from glare control, some of the exterior shades showed significantly greater energy use when discomfort glare-based operation of interior shades was considered.

Hoffmann, Sabine↗

Potential Demand Reduction from Buildings in a Simulated Utility

The availability of large-area sensing, scalable algorithms, and high-performance computing has enabled the possibility of urban-scale building energy modeling using new methods not limited to the scalability of manual building energy model creation or retrieval of county-by-county tax assessor’s data. Automatic Building detection and Energy Model creation (AutoBEM) has created 178,368 building energy models for the Electric Power Board (EPB) of Chattanooga, TN, and compared simulation performance to 15-minute data from each building. These models leverage several data sources (e.g. imagery, GIS, utility), software tools to extract building properties (e.g. footprint, height, façade type, window-to-wall ratio, occupancy, building type), simulate at scale on two of the world’s #1 fastest supercomputers, and provide web-based visual analytics.Grid-interactive efficient buildings offer the potential to reduce utility and rate-payer energy costs during each calendar month’s hour of critical generation – when the least efficient, most costly, and often dirtiest generation assets must be brought online. In this paper, EnergyPlus is used to simulate over 150,000 buildings to assess the technical potential of utility-controlled smart thermostats. This is analyzed under a couple scenarios leveraging buildings as thermal batteries via pre-conditioning to coast through peak hours. Results are provided in box and whisker plots assessing the distribution of peak demand reduction at the utility-scale along with breakouts of energy and demand savings by building type and vintage.

Bass, Brett↗

Automatic Lane-Level Road Network Extraction from Aerial Imagery for Transportation Digital Twins

Accurate road networks are essential for credible traffic microsimulation and transportation digital twins, yet high-definition maps are often difficult to obtain due to limited availability, high cost, or proprietary restrictions. Some build networks from crowdsourced data, such as OpenStreetMap, but these sources often contain geometric and semantic inconsistencies. Others create networks manually, a process that is labor-intensive and difficult to scale. To address these limitations, this work presents an end-to-end pipeline that automatically extracts georeferenced, lane-level road networks from publicly available high-resolution satellite imagery and converts them into simulation-ready assets. The developed end-to-end pipeline has three primary modules: (1) A computer-vision-based module first detects directed lane geometries and intersection layouts. (2) A heuristic-based topology construction module then identifies approach and exit legs and establishes conflict-free lane-to-lane connections. (3) Finally, an automatic simulation-building module converts the extracted network into standard formats, e.g., OpenDRIVE, and generates routable SUMO networks. The framework supports both complete network construction from scratch and local-scale refinement of existing networks through lane-count correction, transition recovery, and geometric regularization. The proposed pipeline provides a practical pathway to generate traffic simulation networks from satellite imagery, significantly reducing manual reconstruction effort and enabling scalable, continuously updated transportation digital twins.

Guo, Hetian [University of Georgia, Athens] (ORCID↗

Airside HVAC BESTEST. Adaptation of ASHRAE RP 865 Airside HVAC Equipment Modeling Test Cases for ASHRAE Standard 140. Volume 1, Cases AE101-AE445

This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts

This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

Wake characteristics of buildings in disturbed boundary layers

Measurements relevant to the effect of buildings on the low level atmospheric boundary layer are presented. Field measurements of velocity and turbulence in the wake of a block building 3.2 m high and 26.8 m long are presented which show an apparent increase in momentum flow above the upwind value. Velocity-deficit and turbulence-excess decay characteristics of the disturbed or nonequilibrium layer are correlated with power law exponents and apparent roughness length at various distances downstream of the disturbance. Model wake profiles from the simulated building are compared at various stations for equilibrium and nonequilibrium upstream profiles. Empirical correlations relating building wake profiles to upstream nonequilibrium parameters are presented. The relationship of the data to the smooth-rough transition is discussed, and a flow model is presented.

Logan, E., Jr.↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

code compliance↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

Energy Codes, code compliance↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AutoSIM

AutoSIM enables several instances of an executable to run in parallel on a directory of input files and consolidate results, at scale on the world's fastest supercomputers. The software accomplishes this by balancing compression, transmission, and computation of input files, executables, and output files to allow scalable parallel runs of any executable. The software breaks-up simulations into a configurable number of "churns" or sequential instances of executable invocations on a configurable number of cores/node. It sends the executable, supporting files, and appropriate number of input files to each node for independent execution, and then transfers the executable results to a shared disk for post-processing analysis. This MPI-based code has been demonstrated using EnergyPlus, DOE's flagship whole-building simulation engine, but was architected to allow scalable runtime of any software for any application (e.g. sensitivity analysis and uncertainty quantification). The code has also been demonstrated to scale on the Titan supercomputer using 131,072 processors to run 524,288 EnergyPlus annual simulations, and write 45TB of data to disk in 68 mins 08 secs.

New, Joshua R↗