Progress of neutral-beam-aided diagnostics on the HL-2A tokamak

A 32/64-channel Charge eXchange Recombination Spectroscopy (CXRS) and a 7-channel motional Stark effect (MSE) polarimeter have been developed on the HL-2A tokamak. To extract the maximum time resolution of the system, the incidence fibers of the spectrometer are pitch-controlled; and the double-slit fiber bundle can increase the spatial channels with one charge-coupled device detector. The ion temperature and plasma rotation with time and spatial resolutions up to 5 ms and 1 cm are obtained. Sawtooth oscillation, transition from intermediate phase (I phase) to high confinement mode (H mode) can be clearly observed by the CXRS. The spectrometer can be utilized as the main component of the MSE polarimeter, which can effectively overcome the weak Stark effect. The pitch angles of magnetic field are obtained for 7 spatial points covering 24 cm along major radius with time resolution of 40 ms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

Development of an Accelerator Mass Spectrometer based on a Cyclotron

An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

43 PARTICLE ACCELERATORS↗

Beams, brightness, and background: Using active spectroscopy techniques for precision measurements in fusion plasma research

The use of an injected neutral beam-either a dedicated diagnostic beam or the main heating beams-to localize and enhance plasma spectroscopic measurements can be exploited for a number of key physics issues in magnetic confinement fusion research, yielding detailed profile information on thermal and fast ion parameters, the radial electric field, plasma current density, and turbulent transport. The ability to make these measurements has played a significant role in much of our recent progress in the scientific understanding of fusion plasmas. The measurements can utilize emission from excited state transitions either from plasma ions or from the beam atoms themselves. The primary requirement is that the beam 'probe' interacts with the plasma in a known fashion. Advantages of active spectroscopy include high spatial resolution due to the enhanced localization of the emission and the use of appropriate imaging optics, background rejection through the appropriate modulation and timing of the beam and emission collection/detection system, and the ability of the beam to populate emitter states that are either nonexistent or too dim to utilize effectively in the case of standard or passive spectroscopy. In addition, some active techniques offer the diagnostician unique information because of the specific quantum physics responsible for the emission. This paper will describe the general principles behind a successful active spectroscopic measurement, emphasize specific techniques that facilitate the measurements and include several successful examples of their implementation, briefly touching on some of the more important physics results. It concludes with a few remarks about the relevance and requirements of active spectroscopic techniques for future burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An integrated wire harp and readout electronics inside vacuum

A wire harp is a well known instrument used in ion beam profile measurement and beam diagnostics. Till date, for beam instrumentation, the harp is placed inside the vacuum chamber or beam line in direct exposure to the beam profile to be measured, whereas the related readout electronics is placed outside somewhere at a convenient place. Here, a harp has been developed along with the readout electronics as an integrated part of it and both were placed inside the beam line vacuum (order of 10{sup −7} Torr) to make the system much simpler, easy to operate, and measure small beam current more accurately. The entire signal conversion and processing is done inside the vacuum unlike other systems; hence, the electronics is kept inside. This results in a lesser number (only 4 pin) of electrical connections (feedthrough) including power which otherwise would have required 32 feedthrough pins only for signal readout for a 13 × 13 (X × Y) channel harp. This paper describes a completely new approach to the design of a conventional beam harp widely used for beam instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a self-diagnostic beam-mode piezoelectric accelerometer

A technique was developed for detecting in situ real-time soft failures in a beam-mode piezoelectric accelerometer. The new technique can be used to detect changes in the piezoelectric capacitance, the equivalent mechanical stiffness of the piezoelectric element and the surface mounting impedance, and the piezoelectric efficiency.

Flanagan, Patrick M.↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is a fast-response, time-dependent beam diagnostic for measuring the emitted spot size and beam target interactions from radiographic x-ray sources. Legacy streaked TRSD analysis requires image processing and data extraction, which give noisy results. Processed data are used to extract edge spread and corresponding line spread functions. Digital TRSD simplifies this process, eliminating the complexity of streak camera–based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗