Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ion mobility spectrometer with virtual aperture grid

An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

Pfeifer, Kent B↗

Aperture Test for Internal Target Operation in the JLAB High-current ERL

A high current beam transmission test has been successfully completed at the JLAB FEL Facility, culminating in very low-loss transmission of a high current CW beam through a small aperture. The purpose of this test was to determine if an ERL is capable of meeting the stringent requirements imposed by the use of a 1018/cm3 internal gas target proposed for the DarkLight experiment*. Minimal beamline modifications were made to create a machine configuration that is substantially different from those used in routine UV or IR FEL operation. A sustained (8 hour) high power beam run was performed, with clean transmission through a 2 mm transverse aperture of 127 mm length simulating the target configuration. A beam size of 50 um (rms) was measured near the center of the aperture. Experimental data from a week-long test run consistently exhibited beam loss of only a few ppm on the aperture while running 4.5 mA current at 100 MeV -- or nearly 0.5 MW beam power. This surpassed the users? expectation and demonstrated a unique capability of an ERL for this type of experiments. This report presents a summary of the experiment, a brief overview of our activities, and outlines future plans.

43 PARTICLE ACCELERATORS↗

Apparatus and method for deterministic control of surface figure during full aperture polishing

A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. The first and second radial directions may be opposite directions.

42 ENGINEERING↗

Quench Performance of the First Twin-aperture 11 T Dipole for LHC upgrades

FNAL and CERN are developing a twin-aperture 11 T $Nb_{3}Sn$ dipole suitable for installation in the LHC. A single-aperture 2-m long dipole demonstrator and two 1-m long dipole models have been fabricated and tested at FNAL in 2012-2014. The two 1 m long collared coils were then assembled into the first twin-aperture $Nb_{3}Sn$ demonstrator dipole and tested. Test results of this twin-aperture $Nb_{3}Sn$ dipole model are reported and discussed.

Zlobin, A. V.↗

The Effect of a Pre-Lens Aperture on the Temperature Range and Image Uniformity of Microbolometer Infrared Cameras

This paper explores the temperature range extension of long-wavelength infrared (LWIR) cameras by placing an aperture in front of the lens. An aperture smaller than the lens will reduce the radiance to the sensor, allowing the camera to image targets much hotter than typically allowable. These higher temperatures were accurately determined after developing a correction factor which was applied to the built-in temperature calibration. The relationship between aperture diameter and temperature range is linear. The effect of pre-lens apertures on the image uniformity is a form of anti-vignetting, meaning the corners appear brighter (hotter) than the rest of the image. An example of using this technique to measure temperatures of high melting point polymers during 3D printing provide valuable information of the time required for the weld-line temperature to fall below the glass transition temperature.

3D Printing↗

Broadband light funneling in ultrasubwavelength channels having periodic connected unfilled apertures

A structure for broadband light funneling comprises a two-dimensional periodic array of connected ultrasubwavelength apertures, each aperture comprising a large sub-aperture that aids in the coupling of the incoming incident light and a small sub-aperture that funnels a significant fraction of the incident light power. The structure possesses all the capabilities of prior extraordinary optical transmission platforms, yet operates nonresonantly on a distinctly different mechanism. The structure demonstrates efficient ultrabroadband funneling of optical power confined in an area as small as .about.(.lamda./500).sup.2, where optical fields are enhanced, thus exhibiting functional possibilities beyond resonant platforms.

36 MATERIALS SCIENCE↗

Apparatus and method for deterministic control of surface figure during full aperture pad polishing

A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. The first and second radial directions may be opposite directions.

42 ENGINEERING↗

Multi-aperture optical system for high-resolution imaging

Technologies pertaining to a multi-aperture optical imaging system are described herein. The multi-aperture optical system comprises an afocal optical telescope and a plurality of sub-apertures that receive light from the telescope. Each sub-aperture comprises a focusing optic that creates a full-field image onto an individual image sensor that outputs data indicative of an intensity of light received at the sensor. Image processing techniques can be used to combine the sensor outputs for spectral discrimination, to improve dynamic range or to enhance resolution of a scene.

47 OTHER INSTRUMENTATION↗

Dependence of vacuum electrical breakdown field and field enhancement factor on the number of apertures drilled in small electrodes

Pre-breakdown current based on field-emission current is regarded as one of factors causing the vacuum electrical breakdown (BD) between the multi-aperture acceleration grids in the JT-60 negative ion source. In this paper, we focused on field enhancement factor β which is a key parameter of field-emission on the cathode. Vacuum BD tests for small-size electrodes drilled different number of apertures were carried out to investigate the β and BD field characteristics in the conditioning process of each electrode. Experimental results revealed that the increase of the number of apertures drilled in the electrode causes the increase of β value, and high β value reduces the dielectric strength of these electrodes. This result demonstrates that flowing field-emission current between the multi-aperture electrodes causes vacuum BD event. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-body coherent aperture synthesis

An antenna is provided with sub-apertures whose relative locations change and that are not connected via a mechanical link. a Multi-Body Coherent Aperture Synthesis system supports an antenna with sub-aperture devices that collect views, collect (using an optical link) ranging information (that includes timing information) relating to distance between sub-aperture devices, and transmit the collected views and ranging information to a master device. The master device synthesizes the collected views into a synthesized image based on the ranging information.

Panas, Robert Matthew↗

Simulation and Theory of Speckle Noise for an Annular Aperture Frequency-Modulation Differential-Absorption LIDAR (FM-DIAL) System

This paper presents theory of speckle noise for a frequency-modulation differential-absorption LIDAR system along with simulation results. These results show an unexpected relationship between the signal-to-noise ratio (SNR) of the speckle and the distance to the retro-reflector or target. In simulation, the use of an annular aperture in the system results in a higher SNR at midrange distances than at short or long distances. This peak in SNR occurs in the region where the laser’s Gaussian beam profile approximately fills the target. This was unexpected since it does not occur in the theory or simulations of the same system with a circular aperture. By including the autocorrelation of this annular aperture and expanding the complex correlation factor used in speckle models to include conditions not generally covered, a more complete theoretical model is derived for this system. Obscuration of the center of the beam at near distances is also a major factor in this relationship between SNR and distance. We conclude by comparing the resulting SNR as a function of distance from this expanded theoretical model to the simulations of the system over a double-pass horizontal range of 10 meters to 10 km at a wavelength of 1.28 micrometers

47 OTHER INSTRUMENTATION↗

GeoSTAR - A Synthetic Aperture Microwave Sounder for Geostationary Missions

The Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR) is a new microwave atmospheric sounder under development. It will bring capabilities similar to those now available on low-earth orbiting environmental satellites to geostationary orbit - where such capabilities have not been available. GeoSTAR will synthesize the multimeter aperture needed to achieve the required spatial resolution, which will overcome the obstacle that has prevented a GEO microwave sounder from being implemented until now. The synthetic aperture approach has until recently not been feasible, due to the high power needed to operate the on-board high-speed massively parallel processing system required for 2D-synthesis, as well as a number of system and calibration obstacles. The development effort under way at JPL, with important contributions from the Goddard Space Flight Center and the University of Michigan, is intended to demonstrate the measurement concept and retire much of the technology risk.

geostationary↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Error performance enhancement of satellite to earth FSO downlink employing hybrid subcarrier intensity modulation scheme with aperture averaging technique

In this work, we have evaluated the bit error rate (BER) of free space optical downlink using hybrid-subcarrier-intensity-modulation (hybrid-SIM) scheme. Also, we have employed the aperture averaging technique for the improvement of its error performance. The required BER analysis has been performed over the gamma–gamma channel model with the scintillation effects. The BER analysis is simplified using Meijer-G function and it is simulated in MATLAB. The simulation results show that the improvement in error performance is observed by hybrid-SIM technique compared to other modulation schemes like PPM and BPSK-SIM and also the BER improves significantly with the increase of aperture size due to the aperture averaging effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Shear Displacement and Stress Changes on Fracture Hydraulic Aperture and Flow Anisotropy

Fluid flow in fractures has the potential to drastically change the economic, environmental, and safety risks associated with a subsurface operation. This work focuses on the analysis of experimental shear fracturing and subsequent shear displacement of a shale specimen that contains multiple pre-existing natural fractures. A triaxial direct shear apparatus with concurrent µCT imaging allowed continuous monitoring of sample permeability and changes in fracture geometry during fracture creation, displacement, and changes in stress. Steady-state, low Reynolds number fluid flow simulations were used to determine the changes of each individual fracture’s hydraulic aperture due to displacement and effective stress. The development of anisotropy in the hydraulic aperture of a generated shear fracture was determined for shear displacements of 0.38, 0.74, and 2.04 mm. At high confining stress (30 MPa), shear displacement significantly reduced the hydraulic aperture of the shear fracture to below flow detectable limits and X-ray imaging resolution (23 × 23 × 23 µm 3 ). The shear generated fracture was found to be more sensitive to changes in effective stress compared to the pre-existing natural fractures. Existing models derived from fluid flow equations accounting for stochastic fracture roughness were able to partially fit the simulated flow properties of the pre-existing fractures, but no model was found to fit the flow properties of the newly formed shear fracture. These results are the first report of simultaneous changes in the geometry and flow properties of surrounding, parallel natural fractures as a shear fracture is generated with varying stress and shear displacement conditions.

58 GEOSCIENCES↗

Clinical Evaluation of Direct Aperture Optimization When Applied to Head-And-Neck IMRT

Direct Machine Parameter Optimization (DMPO) is a leaf segmentation program released as an optional item of the Pinnacle planning system (Philips Radiation Oncology Systems, Milpitas, CA); it is based on the principles of direct aperture optimization where the size, shape, and weight of individual segments are optimized to produce an intensity modulated radiation treatment (IMRT) plan. In this study, we compare DMPO to the traditional method of IMRT planning, in which intensity maps are optimized prior to conversion into deliverable multileaf collimator (MLC) apertures, and we determine if there was any dosimetric improvement, treatment efficiency gain, or planning advantage provided by the use of DMPO. Eleven head-and-neck patients treated with IMRT had treatment plans generated using each optimization method. For each patient, the same planning parameters were used for each optimization method. All calculations were performed using Pinnacle version 7.6c software and treatments were delivered using a step-and-shoot IMRT method on a Varian 2100EX linear accelerator equipped with a 120-leaf Millennium MLC (Varian Medical Systems, Palo Alto, CA). Each plan was assessed based on the calculation time, a conformity index, the composite objective value used in the optimization, the number of segments, monitor units (MUs), and treatment time. The results showed DMPO to be superior to the traditional optimization method in all areas. Considerable advantages were observed in the dosimetric quality of DMPO plans, which also required 32% less time to calculate, 42% fewer MUs, and 35% fewer segments than the conventional optimization method. These reductions translated directly into a 29% decrease in treatment times. While considerable gains were observed in planning and treatment efficiency, they were specific to our institution, and the impact of direct aperture optimization on plan quality and workflow will be dependent on the planning parameters, planning system, and linear accelerators used by a particular institution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

millimeter aperture↗

Strong terahertz radiation from air plasmas generated by an aperture-limited Gaussian pump laser beam

Terahertz radiation generated by focusing the fundamental laser pulse and its second harmonic into ambient air strongly saturates with increasing pump laser energy. We demonstrate a simple method to control the Gaussian pump laser beam to improve the output of terahertz radiation with an adjustable aperture. With the optimal aperture-limited pump laser beams, the terahertz wave amplitudes can be enhanced by more than eight times depending on the pump laser parameters than those of aperture-free cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗