Severe winds in the DFW microburst measured from two aircraft

Advanced analytical methods are applied to the digital flight data and Air Traffic Control radar records from two airliners, Delta flight 191 and American flight 539, that penetrated a microburst at the Dallas/Ft. Worth airport on August 2, 1985. The results for Delta 191 (which crashed) show that the aircraft encountered a strong downburst followed by a strong outflow accompanied by large and rapid changes in the vertical wind. The rapid changes in the vertical wind detected near the ground are attributed to vortex-induced turbulence. The next following aircraft, American 539, made a go-around 110 sec after Delta 191 and traversed the microburst at an altitude of about 2500 ft above the ground. The measured winds during this go-around indicate a broad pattern of downflow in the microburst, with regions of upflow at the extreme edges. The combined results indicate a microburst that was increasing in size with vortex-induced turbulence embedded in a strong outflow near the ground. These wind measurements provide a realistic description of the microburst wind environment that can be used in simulator studies and pilot training, and provide a standard of comparison for ongoing experiments and modeling of microbursts involving vortex rings.

Wingrove, R. C.↗

Ultrasonic inspection of carbon fiber reinforced plastic by means of sample-recognition methods

In the case of carbon fiber reinforced plastic (CFRP), it has not yet been possible to detect nonlocal defects and material degradation related to aging with the aid of nondestructive inspection method. An approach for overcoming difficulties regarding such an inspection involves an extension of the ultrasonic inspection procedure on the basis of a use of signal processing and sample recognition methods. The basic concept involved in this approach is related to the realization that the ultrasonic signal contains information regarding the medium which is not utilized in conventional ultrasonic inspection. However, the analytical study of the phyiscal processes involved is very complex. For this reason, an empirical approach is employed to make use of the information which has not been utilized before. This approach uses reference signals which can be obtained with material specimens of different quality. The implementation of these concepts for the supersonic inspection of CFRP laminates is discussed.

Bilgram, R.↗

Orion MPCV Touchdown Detection Threshold Development and Testing

A robust method of detecting Orion Multi-Purpose Crew Vehicle (MPCV) splashdown is necessary to ensure crew and hardware safety during descent and after touchdown. The proposed method uses a triple redundant system to inhibit Reaction Control System (RCS) thruster firings, detach parachute risers from the vehicle, and transition to the post-landing segment of the Flight Software (FSW). An in-depth trade study was completed to determine optimal characteristics of the touchdown detection method resulting in an algorithm monitoring filtered, lever-arm corrected, 200 Hz Inertial Measurement Unit (IMU) vehicle acceleration magnitude data against a tunable threshold using persistence counter logic. Following the design of the algorithm, high fidelity environment and vehicle simulations, coupled with the actual vehicle FSW, were used to tune the acceleration threshold and persistence counter value to result in adequate performance in detecting touchdown and sufficient safety margin against early detection while descending under parachutes. An analytical approach including Kriging and adaptive sampling allowed for a sufficient number of finite element analysis (FEA) impact simulations to be completed using minimal computation time. The combination of a persistence counter of 10 and an acceleration threshold of approximately 57.3 ft/s2 resulted in an impact performance factor of safety (FOS) of 1.0 and a safety FOS of approximately 2.6 for touchdown declaration. An RCS termination acceleration threshold of approximately 53.1 ft/s(exp)2 with a persistence counter of 10 resulted in an increased impact performance FOS of 1.2 at the expense of a lowered under-parachutes safety factor of 2.2. The resulting tuned algorithm was then tested on data from eight Capsule Parachute Assembly System (CPAS) flight tests, showing an experimental minimum safety FOS of 6.1. The formulated touchdown detection algorithm will be flown on the Orion MPCV FSW during the Exploration Flight Test 1 (EFT-1) mission in the second half of 2014.

Daum, Jared↗

Biology and the Exploration of Mars

Until recent years the origin of life and its possible occurrence elsewhere in the universe have been matters for speculation only. The rapid growth of molecular biology since 1940 has, to be sure, made it possible to discuss life's origins in far more precise and explicit terms than was possible earlier; and the subject entered a new experimental phase in the 1950's with successful abiogenic synthesis of important biochemical substances in conditions simulating the presumptive environment of the primitive Earth. But the real transformation that the subject has undergone stems from the spectacular growth of space technology in the last decade. The possibility of life's origin and occurrence on planets other than ours is no longer limited to idle speculation: it has entered the realm of the testable, of science in the strict sense. Given the rockets now available, and especially those available by 1969, it has become fully realistic to consider plans for the biological exploration of Mars. The study that this report seeks to interpret was initiated in June, 1964, by the Space Science Board of the National Academy of Sciences to examine this possibility. The working group comprised 36 people representing a broad spectrum of scientific interests: evolutionary biology, genetics, microbiology, biochemistry and molecular biology, animal physiology, soil chemistry, organic chemistry, planetary astronomy, geochemistry, and theoretical physics. The participants included some with considerable prior involvement in problems of space exploration and others with none. Advice was also sought outside the group of immediate participants on the potentialities of selected analytical methods for the experimental study of extraterrestrial life and its environment. More than 30 individuals contributed in this fashion written assessments of techniques in which they were particularly well versed. Our task was to examine the scientific foundations and merits of the proposal to undertake a biological exploration of Mars. What are the potential scientific yields? How valuable, if attained, would they be? What, in fact, is the possibility of life occurring on Mars? And of our detecting it with available and foreseeable technology? What could be achieved by further astronomical work from Earth? by Martian fly-by missions? by Martian orbiters? and Martian Landers? What payloads would we recommend for planetary missions? What timing and over-all strategy would we recommend for Martian exploration were we to consider it worthwhile at all? In brief, the over-all purpose was to recommend to. the government, through the Academy's Space Science Board, whether or not a biological exploration of Mars should be included in the nation's space program over the next few decades; and, further, to outline what that program, if any, should be.

CONFERENCE↗

Vibration Based Crack Detection in a Rotating Disk: An Analytical Study - Part 1

This paper describes the analytical results concerning the detection of a crack in a rotating disk. The concept of the approach is based on the fact that the development of a disk crack results in a distorted strain field within the component. As a result, a minute deformation in the disk's geometry as well as a change in the system s center of mass occurs. Finite element analyses were conducted concerning a notched disk in order to define the sensitivity of the method. The notch was used to simulate an actual crack and will be the method utilized for upcoming experiments. Various notch sizes were studied. The geometric deformations and shifts of center of mass were documented as a function of rotational speed. In addition, a rotordynamic analysis of a 2-bearing, disk and shaft system was conducted. The overall response of the system was required in order to design the experimental system for operation beyond the first critical. The results of the FE analyses of the disk indicated that the overall changes in the disk s geometry and center of mass were rather small. The difference between the maximum centrifugal radial displacements between the undamaged and damaged disks at 8000 RPM was 0.00014 in. for a 0.963 in. notch length. The shift in center of mass was also of this magnitude. The next step involves running experiments to verify the analysis.

Gyekenyesi, Andrew L.↗

Pioneering a Biobased UAS

With the exponential growth of interest in unmanned aerial vehicles (UAVs) and their vast array of applications in both space exploration and terrestrial uses such as the delivery of medicine and monitoring the environment, the 2014 Stanford-Brown-Spelman iGEM team is pioneering the development of a fully biological UAV for scientific and humanitarian missions. The prospect of a biologically-produced UAV presents numerous advantages over the current manufacturing paradigm. First, a foundational architecture built by cells allows for construction or repair in locations where it would be difficult to bring traditional tools of production. Second, a major limitation of current research with UAVs is the size and high power consumption of analytical instruments, which require bulky electrical components and large fuselages to support their weight. By moving these functions into cells with biosensing capabilities - for example, a series of cells engineered to report GFP, green fluorescent protein, when conditions exceed a certain threshold concentration of a compound of interest, enabling their detection post-flight - these problems of scale can be avoided. To this end, we are working to engineer cells to synthesize cellulose acetate as a novel bioplastic, characterize biological methods of waterproofing the material, and program this material's systemic biodegradation. In addition, we aim to use an "amberless" system to prevent horizontal gene transfer from live cells on the material to microorganisms in the flight environment. So far, we have: successfully transformed Gluconacetobacter hansenii, a cellulose-producing bacterium, with a series of promoters to test transformation efficiency before adding the acetylation genes; isolated protein bands present in the wasp nest material; transformed the cellulose-degrading genes into Escherichia coli; and we have confirmed that the amberless construct prevents protein expression in wild-type cells. In addition, as part of our human outreach project, we have been in touch with leaders in the fields of UAVs, synthetic biology, and earth sciences, and it is clear that biodegradable UAVs could have a significant impact on the industry.

Escherichia↗

Towards a Biosynthetic UAV

We are currently working on a series of projects towards the construction of a fully biological unmanned aerial vehicle (UAV) for use in scientific and humanitarian missions. The prospect of a biologically-produced UAV presents numerous advantages over the current manufacturing paradigm. First, a foundational architecture built by cells allows for construction or repair in locations where it would be difficult to bring traditional tools of production. Second, a major limitation of current research with UAVs is the size and high power consumption of analytical instruments, which require bulky electrical components and large fuselages to support their weight. By moving these functions into cells with biosensing capabilities - for example, a series of cells engineered to report GFP, green fluorescent protein, when conditions exceed a certain threshold concentration of a compound of interest, enabling their detection post-flight - these problems of scale can be avoided. To this end, we are working to engineer cells to synthesize cellulose acetate as a novel bioplastic, characterize biological methods of waterproofing the material, and program this material's systemic biodegradation. In addition, we aim to use an "amberless" system to prevent horizontal gene transfer from live cells on the material to microorganisms in the flight environment.

Biological↗

Pioneering a Biobased UAS

With the exponential growth of interest in unmanned aerial vehicles (UAVs) and their vast array of applications in both space exploration and terrestrial uses such as the delivery of medicine and monitoring the environment, the 2014 Stanford-Brown-Spelman iGEM team is pioneering the development of a fully biological UAV for scientific and humanitarian missions. The prospect of a biologically-produced UAV presents numerous advantages over the current manufacturing paradigm. First, a foundational architecture built by cells allows for construction or repair in locations where it would be difficult to bring traditional tools of production. Second, a major limitation of current research with UAVs is the size and high power consumption of analytical instruments, which require bulky electrical components and large fuselages to support their weight. By moving these functions into cells with biosensing capabilities – for example, a series of cells engineered to report GFP, green fluorescent protein, when conditions exceed a certain threshold concentration of a compound of interest, enabling their detection post-flight – these problems of scale can be avoided. To this end, we are working to engineer cells to synthesize cellulose acetate as a novel bioplastic, characterize biological methods of waterproofing the material, and program this material’s systemic biodegradation. In addition, we aim to use an “amberless” system to prevent horizontal gene transfer from live cells on the material to microorganisms in the flight environment. So far, we have: successfully transformed Gluconacetobacter hansenii, a cellulose-producing bacterium, with a series of promoters to test transformation efficiency before adding the acetylation genes; isolated protein bands present in the wasp nest material; transformed the cellulose-degrading genes into Escherichia coli; and we have confirmed that the amberless construct prevents protein expression in wild-type cells. In addition, as part of our human outreach project, we have been in touch with leaders in the fields of UAVs, synthetic biology, and earth sciences, and it is clear that biodegradable UAVs could have a significant impact on the industry.

Escherichia↗

Optical Spectroscopy of Venus Aerosol Analogs and Substrate Survivability

Aerosol Rapid Analysis Combined Entry Probe/Sonde Technology (AERACEPT) is a dual descent probe and in-situ sampler of cloud and aerosol particles, used as part of the Nephele mission concept to study Venus cloud layers. Various optical spectroscopic characterization methods, including Raman spectroscopy and Surface Enhanced Raman Spectroscopy (SERS), Laser induced Breakdown Spectroscopy (LIBS), and absorbance and fluorescence spectroscopy are being assessed for viability for compatibility with AERACEPT. Specifically, the detection limits, sensitivity, specificity, and analysis cadence of these techniques for a set of Venus aerosol analogs and their mixtures are tested. We report on preliminary optical spectroscopy results of the Venus aerosol analogs, as well as optical substrate survivability in heated and acidic conditions, substrate physical robustness, and analyte wettability on substrates.

Venus↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Visible absorbance spectra: A basis for in situ and passive remote sensing of phytoplankton concentration and community composition

The concentration and composition of phytoplankton populations are measured by an optical method which can be used either in situ or remotely. This method is based upon the in vivo light absorption characteristics of phytoplankton. To provide a data base for testing assumptions relative to the proposed method, visible absorbance spectra of pure cultures of 20 marine phytoplankton were obtained under laboratory conditions. Descriptive and analytical statistics were computed for the absorbance spectra and were used to make comparisons between members of major taxonomic groups and between groups. Spectral variation between the members of the major taxonomic groups was observed to be considerably less than the spectral variation between these groups. In several cases the differences between the mean absorbance spectra of major taxonomic groups are significant enough to be detected with passive remote sensing techniques.

Farmer, F. H.↗

Health Monitoring of a Rotating Disk Using a Combined Analytical-Experimental Approach

Rotating disks undergo rigorous mechanical loading conditions that make them subject to a variety of failure mechanisms leading to structural deformities and cracking. During operation, periodic loading fluctuations and other related factors cause fractures and hidden internal cracks that can only be detected via noninvasive types of health monitoring and/or nondestructive evaluation. These evaluations go further to inspect material discontinuities and other irregularities that have grown to become critical defects that can lead to failure. Hence, the objectives of this work is to conduct a collective analytical and experimental study to present a well-rounded structural assessment of a rotating disk by means of a health monitoring approach and to appraise the capabilities of an in-house rotor spin system. The analyses utilized the finite element method to analyze the disk with and without an induced crack at different loading levels, such as rotational speeds starting at 3000 up to 10 000 rpm. A parallel experiment was conducted to spin the disk at the desired speeds in an attempt to correlate the experimental findings with the analytical results. The testing involved conducting spin experiments which, covered the rotor in both damaged and undamaged (i.e., notched and unnotched) states. Damaged disks had artificially induced through-thickness flaws represented in the web region ranging from 2.54 to 5.08 cm (1 to 2 in.) in length. This study aims to identify defects that are greater than 1.27 cm (0.5 in.), applying available means of structural health monitoring and nondestructive evaluation, and documenting failure mechanisms experienced by the rotor system under typical turbine engine operating conditions.

Abdul-Aziz, Ali↗

Observability during planetary approach navigation

The objective of the research is to develop an analytic technique to predict the relative navigation capability of different Earth-based radio navigation measurements. In particular, the problem is to determine the relative ability of geocentric range and Doppler measurements to detect the effects of the target planet gravitational attraction on the spacecraft during the planetary approach and near-encounter mission phases. A complete solution to the two-dimensional problem has been developed. Relatively simple analytic formulas are obtained for range and Doppler measurements which describe the observability content of the measurement data along the approach trajectories. An observability measure is defined which is based on the observability matrix for nonlinear systems. The results show good agreement between the analytic observability analysis and the computational batch processing method.

Bishop, Robert H.↗

Standardization of surface contamination analysis systems

Corrosion products, oils and greases can potentially degrade material bonding properties. The Marshall Space Flight Center (MSFC) Surface Contamination Analysis Team (SCAT) utilizes a variety of analytical equipment to detect identify and quantify contamination on metallic and non-metallic substrates. Analysis techniques include FT-IR Microscopy (FT-IR), Near Infrared Optical Fiber Spectrometry (NIR), Optically Stimulated Electron Emission (OSEE), Ultraviolet Fluorescence (UVF) and Ellipsometry. To insure that consistent qualitative and quantitative information are obtained, standards are required to develop analysis techniques, to establish instrument sensitivity to potential contaminants, and to develop calibration curves. This paper describes techniques for preparing and preserving contamination standards. Calibration of surface contamination analysis systems is discussed, and methods are presented for evaluating the effects of potential contaminants on bonding properties.

Boothe, Richard E.↗

An Active Subspace Method for Accelerating Convergence in Delaunay-Based Optimization via Dimension Reduction

Delaunay-based derivative-free optimization, ∆DOGS, is an efficient and provably-convergent global optimization method for the problems which has computationally expensive objection function and the analytical expression for the objective function is not available. ∆-DOGS is a novel optimization scheme in the family of response surface methods (RSMs); however, it suffers from the curse of dimensionality since the computational cost increases dramatically as the number of design parameters increases. As a result, the number of design parameters in ∆-DOGS algorithm is relatively low (n.10). To avoid such problems, this paper proposes a combination of derivative-free optimization, seeking the global minimizer of an expensive and nonconvex objective function f(x) and active subspace method, detecting the directions of the most variability using evaluations of the gradient. The contribution of other directions to the objective function is bounded by a sufficiently small constant. This new algorithm iteratively applied Delaunay-based derivative-free optimization to seek the minimizer on the d-dimensional active subspace that has most function variation. Inverse mapping is needed to project data from active subspace to full-model for evaluating function values. This task is overcome by solving an inequality constrained problem that curves the response surface of the objective function. The test results show that this strategy is effective on a handful of optimization problems.

Bewley, Thomas R.↗

Identifying or measuring selected substances or toxins in a subject using resonant raman signals

Methods and systems of the present invention identify the presence of and/or the concentration of a selected analyte in a subject by: (a) illuminating a selected region of the eye of a subject with an optical excitation beam, wherein the excitation beam wavelength is selected to generate a resonant Raman spectrum of the selected analyte with a signal strength that is at least 100 times greater than Raman spectrums generated by non-resonant wavelengths and/or relative to signals of normal constituents present in the selected region of the eye; (b) detecting a resonant Raman spectrum corresponding to the selected illuminated region of the eye; and (c) identifying the presence, absence and/or the concentration of the selected analyte in the subject based on said detecting step. The apparatus may also be configured to be able to obtain biometric data of the eye to identify (confirm the identity of) the subject.

Lambert, James L.↗

Passive microwave measurements of temperature and salinity in coastal zones

Experimental methods and results from the maritime remote sensing (MARSEN) experiments using dual frequency microwave radiometer detecting systems on board aircraft are described. The radiometers were operated at 1.43 and 2.65 GHz and flown above U.S. Atlantic coastal areas, Chesapeake Bay, around Puerto Rico, and over the German Bight. The advanced switched radiometers used were configured to be independent of gain variations and errors originating from front-end losses and determined the absolute brightness temperatures to within a few tenths Kelvin. Corrections to the observed brightness temperature of the ocean are analytically defined, including accounts made for roughness, the cosmic background radiation, and the solar radio source. The coastal flight data for salinity gradients and surface temperatures were compared with sea truth measured from ships and found to be accurate to within 1 C and 1 pph.

Blume, H.-J. C.↗

Electrical self-calibration of nonideal bolometers

An analytical method for determining the absorbed energy calibration of an IR bolometer from purely electrical measurements is presented. The technique is targeted at detectors with purely electrical nonlinearities. It is shown that the responsivity can be derived from the I-V plot if the limiting high-frequency impedance is measured. The electrical nonlinearity is then the difference between the impedance and the dc resistance. The model is used for designing a circuit for measuring the relative impedance parameters. The results are applicable to studies of IR sources and the detection of energy pulses with bolometers.