Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ampere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Inert gas test of two 12-cm magnetostatic thrusters

Comparative performance tests were conducted with 12 cm line and ring magnetic cusp thrusters. Shell anode and magnetoelectrostatic containment boundary anode configurations were evaluated with each magnet array. The best performance was achieved with the 12-cm ring cusp-shell anode configuration. Argon operation of this configuration produced 65-81 percent mass utilization efficiency at 170-208 watts/single-charged-equivalent (SCE) ampere beam. Xenon test results showed 75-95 percent utilization at 162-188 watts/SCE ampere beam.

Ramsey, W. D.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

Test results of a ten cell bipolar nickel-hydrogen battery

A ten cell bipolar nickel hydrogen 6.5 ampere-hour battery demonstrated over 2000 low earth orbit cycles at an 80 percent depth-of-discharge. Charge/discharge cyclic ampere-hour and watt-hour efficiencies of 88 and 76 percent, respectively, observed. Peak power capability was determined at 1.1 kW. A 10C discharge rate yields 83 percent of the nominal stark capacity to the 1.0 volt cut off in just under 6 minutes. Previously announced in STAR as N83-26253

Cataldo, R. L.↗

Digital High-Current Monitor

Simple technique developed for monitoring direct currents up to several hundred amperes and digitally displaying values directly in current units. Used to monitor current magnitudes beyond range of standard laboratory ammeters, which typically measure 10 to 20 amperes maximum. Technique applicable to any current-monitoring situation.

Cash, B.↗

Accelerated and real-time geosynchronous life cycling test performance of nickel-hydrogen batteries

RCA Astro-Electronics currently has four nickel-hydrogen storage battery modules (11 cells each) on test in simulated geosynchronous life cycle regimes. These battery modules are of identical design to those used on the GSTAR (GTE Satellite Corp.) and Spacenet (GTE Spacenet Corp.) communications satellites. The batteries are being tested using an automated test station equipped with computer-controlled environmental chambers and recording equipment. The two battery types, 30 ampere-hours and 40 ampere-hours (GSTAR and Spacenet, respectively), are being electrically cycled using identical 44-day eclipse sequences at 5 C and vary with respect to depth of discharge, recharge ratio, duration of accumulated suntime, and the use of a reconditioning sequence. The test parameters are outlined and the preliminary test data and results are presented.

Green, R. S.↗

Safety hazards associated with the charging of lithium/sulfur dioxide cells

A continuing research program to assess the responses of spirally wound, lithium/sulfur dioxide cells to charging as functions of charging current, temperature, and cell condition prior to charging is described. Partially discharged cells that are charged at currents greater than one ampere explode with the time to explosion inversely proportional to the charging current. Cells charged at currents of less than one ampere may fail in one of several modes. The data allows an empirical prediction of when certain cells will fail given a constant charging current.

Frank, H.↗

Parametric and cycle tests of a 40-AH bipolar nickel-hydrogen battery

The performance of a 12 V, 40 ampere-hour bipolar battery during various charge current, discharge current, temperature, and pressure operating conditions is investigated. The cell voltages, temperatures, ampere-hours, and watt-hours derived from the charge/discharge cycle tests are studied. Consideration is given to battery voltage and discharge capacity as a function of discharge current, the correlation between energy delivered on a discharge and battery temperature, battery voltage response to pulse discharges, and the voltage-temperature relationship. The data reveal that the bipolar Ni-H battery is applicable to high power systems.

Cataldo, R. L.↗

Variable-Speed, Constant-Frequency Generation Of Power

Feedback of stator power and reactive volt-amperes determines rotor excitation. New method involves control circuit separating rotor excitation into generation of slip frequency and control of amplitude and phase. In control circuit, speed determines slip frequency, while stator power and reactive volt-amperes determine amplitude and phase of rotor current.

Brady, Frank J.↗

Evaluation of high-voltage, high-power, solid-state remote power controllers for amps

The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.

Callis, Charles P.↗

Tests of high current hollow cathodes for ion engines

The development of high power, high thrust ion engines requires the development of long life hollow cathodes capable of producing emission currents of hundreds of amperes. This paper describes results obtained through the extended testing of two 12.7 mm diameter hollow cathodes at high emission currents. The first cathode, operated on xenon for a total of 170 hours at an emission current of 100 A, sustained very little damage except for an increase in the cathode orifice diameter, from 0.953 to 1.71 mm. The second cathode was operated on xenon at 150 A emission current continuously for 24 hours, and for over 1000 hours at 100 A on argon with essentially no change in the cathode operating characteristics. Operation of this cathode was terminated due to severe erosion of several discharge chamber components located downstream of the cathode. The erosion of these components occurred despite operation at discharge voltages less than 24 volts, and poses a serious challenge to the sucessful implementation of multi-hundred ampere cathodes and high thrust ion engines.

Brophy, John R.↗

JPS heater and sensor lightning qualification

Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.

Cook, M.↗

Plasma contactor modeling with NASCAP/LEO - Extending laboratory results to space systems

In the laboratory, hollow cathode-based plasma contactors have been observed to both emit and collect ampere-level electron currents with low impedance. The laboratory behavior of hollow cathode-based plasma contactors and the limited space experience with hollow cathodes suggest that, for many applications, a hollow cathode-based plasma contactor is the ideal device to provide electrical connection with the space plasma. In order to confidently extend the laboratory experience to the low-earth-orbit environment, a series of plasma contactor computer models has been developed. Calculations show that a hollow cathode plasma contactor that collects 0.5 A in the laboratory will only collect 2.4 mA in space. The simplest way to boost the collected current is to increase the gas flow. A mole of gas is enough to collect ampere level currents for 5-1/2 hours.

Davis, V. A.↗

Small-scale plasma irregularities in the nightside Venus ionosphere

The individual volt-ampere curves from the Pioneer Venus Orbiter electron temperature probe showed evidence for small-scale density irregularities, or short-period plasma waves, in regions of the nightside ionosphere where the Orbiter electric field detector observed waves in its 100-Hz channel. A survey of the nightside volt-ampere curves has revealed several hundred examples of such irregularities. The I-V structures correspond to plasma density structure with spatial scale sizes in the range of about 100-2000 m, or alternatively they could be viewed as waves having frequencies extending toward 100 Hz. They are often seen as isolated events, with spatial extent along the orbit frequently less than 80 km. The density irregularities or waves occur in or near prominent gradients in the ambient plasma concentrations both at low altitudes where molecular ions are dominant and at higher altitudes in regions of reduced plasma density where O(+) is the major ion. Electric field 100-Hz bursts occur simultaneously, with the majority of the structured I-V curves providing demonstrative evidence that at least some of the E field signals are produced within the ionosphere.

Grebowsky, J. M.↗

On neutralized currents in the solar corona

Using Ampere's integral law applied to vector magnetograph transverse field data, the current pattern in an active region associated with flaring activity is analyzed. The greater sensitivity of this integral formalism of Ampere's law may allow one to identify regions of weak return current around the actual positive current region. The effects of Faraday rotation on the inferred magnetic field measurements, and hence on the deduced current pattern, are discussed. It is concluded that the current patterns in the region consist either of a neutralized current system, well modeled by a coaxial cable, or of a potential field, with the apparent currents in the core an artifact induced by magneto-optical effects. In either case, the data do not convincingly show an unneutralized current system.

Wilkinson, Ladye K.↗

Photocured Gelled Electrolytes For Secondary Li Cells

Class of photocured polymers exhibiting lithium-ion conductivities greater than those of well-studied polymers based on polyethylene oxide (PEO) show promise as polymeric electrolytes in rechargeable lithium cells. Increase in conductivity occasioned by use of electrolytes, coupled with amenability of electrolytes to formation into uniform thin (less than 25 micrometers thick), wide films, expected to result in cells with power densities greater than 100 W h/kg and charge/discharge rates exceeding currents equal, in amperes, to ampere-hour ratings. All-solid-state lithium batteries containing these electrolytes used as high-power, high-rate rechargeable power sources in commercial and aerospace applications.

Nagasubramanian, Ganesan↗

Kilometer-sized waves in electron density in the Venusian nightside ionosphere

As periapsis of the Pioneer Venus Orbiter (PVO) descended into the lower nightside ionosphere of Venus in the Fall of 1992, wave-like ionospheric density strucutures began to appear on some of the volt-ampere characteristics of the Orbiter Electron Temperature Probe. The number of such events is insufficient to fully define their morphology but enough to provide an indication of the wave amplitudes, scale sizes, occurrence altitudes, and local time variation. The density variations were quasi-sinudoidal, with wavelengths of the order of 1 km along the nearly horizontal trajectory near periapsis. Nearly all of the wave events were encountered within an altitude band lying between 140 and 160 km, a region containing the steep negative N(sub e) gradient just above the ionospheric peak. The waves generally did not fill the occurrence band but were seen primarily as isolated events on curves taken intermittently as PVO crossed through the band. Peak-to-trough amplitudes (delta N/N) were in the range of 5% to 50%. The latitudinal extent of the waves could not be resolved because volt-ampere curves were obtained only intermittent, however, their occurrence on both inbound and outbound passages through the wave band suggests that the waves sometimes exist in layers that extend over at least 15 deg of latitude. The generation mechanism for these waves is unknown, but we suspect that it involves the steep density gradient that separates the main nightside ionosphere from the tenuous, and probably rapidly flowing plasma above.

Brace, Larry H.↗

Preliminary Development of Electrodes for an Electric-Arc Wind Tunnel

Two electrode configurations were tested in an electric-arc wind tunnel at the NASA Lewis Research Center. The results indicated approximately the same heat-loss rate per unit of arc power input for each of the configurations. Measured heat-loss rates were on the order of 40 percent of the arc power input. Nearly all this loss occurred at the anode. The power input and arc current limitations of the electrodes appear to be the critical design factors. Up to now, the maximum power to the stream has been 115 kilowatts with a cooled tungsten cathode and a cooled cylindrical anode incorporating a magnetic field. The maximum power input to this anode could not be established with the cooled tungsten cathode because cathode failures occurred at a gross power level of approximately 175 kilowatts. It was necessary to use a graphite cathode to seek the limitation of the anode. The results indicated that the anode limitation was primarily a function of arc current rather than power input. The anode was successfully operated at a power of 340 kilowatts at 1730 amperes; however, the anode failed with a power input of 324 kilowatts and a current of 2140 amperes. The magnetic flux density at the time of failure was 0.32 weber per square meter, or 3200 gauss. The graphite cathode was used only to establish the anode limitation; further investigation of graphite cathodes was discontinued because of the large amount of stream contamination associated with this type of electrode.

Shepard, Charles E.↗

Kilometer-Sized Waves in Electron Density in the Venusian Nightside Ionosphere

As periapsis of the Pioneer Venus Orbiter (PVO) descended into the lower nightside ionosphere of Venus in the Fall of 1992, wave-like ionospheric density structures began to appear on some of the volt-ampere characteristics of the Orbiter Electron Temperature Probe. The number of such events is insufficient to fully define their morphology but enough to provide an indication of the wave amplitudes, scale sizes, occurrence altitudes, and local time variation. The density variations were quasi-sinusoidal, with wavelengths of the order of 1 km along the nearly horizontal trajectory near periapsis. Nearly all of the wave events were encountered within an altitude band lying between 140 and 160 km, a region containing the steep negative N(sub e) gradient just above the ionospheric peak. The waves generally did not fill the occurrence band but were seen primarily as isolated events on curves taken intermittently as PVO crossed through the band. Peak-to-trough amplitudes ((Delta)N/N) were in the range of 5% to 50%. The waves exhibited little local time variation within the available viewing period (01-04 hrs), with perhaps a tendency for the waves to rise to slightly higher altitudes toward dawn. The latitudinal extent of the waves could not be resolved because volt-ampere curves were obtained only intermittently, however, their occurrence on both inbound and outbound passages through the wave band suggests that the waves sometimes exist in layers that extend over at least 15 deg of latitude. The generation mechanism for these waves is unknown, but we suspect that it involves the steep density gradient that separates the main nightside ionosphere from the tenuous, and probably rapidly flowing plasma above.

Brace, Larry H.↗