Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of the High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art - Measurement and Verification (M&V) Results from Summer, Winter and Spring Evaluation Periods

The High Efficiency Dehumidification System (HEDS) technology from Conservant Systems Inc., installed at the Timken Museum of Art in San Diego, California, was evaluated to determine its performance relative to appropriate baseline operation. Data was collected for measurement and verification for several weeks during three evaluation periods: Summer (Aug-Sep 2023), Winter (Dec 2023-Feb 2024) and Spring (May-Jun 2024). The evaluation included operating the heating, ventilation and air conditioning (HVAC) system in both constant air volume (CAV) and variable air volume (VAV) modes, with and without the HEDS energy recovery and HVAC system optimization technology enabled. The electricity consumption of the chiller and the gas-supplied reheat energy were measured to characterize savings achieved by the HEDS operation. Based on these measurements, the HEDS was responsible for chiller electrical load savings during the summer evaluation period of 39% and 42% for the CAV and VAV operating modes, respectively; 97% and 100% chiller electrical load reductions were observed during the winter evaluation for the CAV and VAV operating modes, respectively; and the corresponding reductions during the spring evaluation were 42% and 52% for CAV and VAV operation, respectively. The measured reheat energy reductions, which are typically provided by natural gas, due to the HEDS during summer were 64% and 97% in CAV and VAV operating modes, respectively, while the corresponding values were 99% and 78% during the winter evaluation, and 59% and 56% during the spring evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental Control Systems

Materials illustrating a presentation on environment control systems for electric flight systems are presented. Schematics and flow diagrams of fresh air source and air conditioning systems, and vapor cycle and air cycle parts lists are presented.

Rosenbush, F. M.↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

NASA Program Environmental Health↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

Heterogeneity in own-price residential customer demand elasticities for electricity under time-of-use rates: Evidence from a randomized-control trial in the United States

Regulators, policymakers, and stakeholders in several states have raised concerns about the price elasticity of residential customers’ electricity demand, especially as related to different customer subpopulations, management of critical end-uses, and enrollment approaches. This analysis sought to quantify the diversity of residential customer price elasticity in a time-of-use rate across these different dimensions using data generated from a utility pricing experiment. Finally, customers were found to be more elastic during the peak period of critical peak days, who were predicted to own and use air conditioning, and who volunteered for time-of-use (TOU) rates (but those defaulted on were 25% as elastic).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A numerical study of the controlled flow tunnel for a high lift model

A controlled flow tunnel employs active control of flow through the walls of the wind tunnel so that the model is in approximately free air conditions during the test. This improves the wind tunnel test environment, enhancing the validity of the experimentally obtained test data. This concept is applied to a three dimensional jet flapped wing with full span jet flap. It is shown that a special treatment is required for the high energy wake associated with this and other V/STOL models. An iterative numerical scheme is developed to describe the working of an actual controlled flow tunnel and comparisons are shown with other available results. It is shown that control need be exerted over only part of the tunnel walls to closely approximate free air flow conditions. It is concluded that such a tunnel is able to produce a nearly interference free test environment even with a high lift model in the tunnel.

Parikh, P. C.↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC End-of-Life: Options and Best Practices

When heating, ventilating, and air-conditioning (HVAC) systems reach end-of-life status, building owners typically seek the quickest, most cost-effective replacement. Although there are several rooftop unit (RTU) replacement tool kits and programs to guide clients through this process, there is limited information on how to handle end-of-life HVAC systems. This fact sheet provides relevant information to help building owners manage proper disposal of HVAC systems, how to navigate regulations, and how to recover economic value from old systems.

30 DIRECT ENERGY CONVERSION↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗