Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A general monitor and control interface to the VAX UNIBUS by way of the DR11-C I/O port

The High Speed Data Acquisition System for the Goldstone Solar System Radar requires a number of interfaces for monitor and control functions for the special purpose data acquisition hardware. One common interface design is used. A large number of external control and monitor registers may be addressed and observed with this interface design, by using only three address locations on the UNIBUS and a standard DEC supplied input/output port. A broadcast control and status register is introduced which addresses any number of different units and registers.

Brokl, S. S.↗

Telemetry Monitoring and Display Using LabVIEW

The Measurement Technology Center of the Instrumentation Section configures automated data acquisition systems to meet the diverse needs of JPL's experimental research community. These systems are based on personal computers or workstations (Apple, IBM/Compatible, Hewlett-Packard, and Sun Microsystems) and often include integrated data analysis, visualization and experiment control functions in addition to data acquisition capabilities. These integrated systems may include sensors, signal conditioning, data acquisition interface cards, software, and a user interface. Graphical programming is used to simplify configuration of such systems. Employment of a graphical programming language is the most important factor in enabling the implementation of data acquisition, analysis, display and visualization systems at low cost. Other important factors are the use of commercial software packages and off-the-shelf data acquisition hardware where possible. Understanding the experimenter's needs is also critical. An interactive approach to user interface construction and training of operators is also important. One application was created as a result of a competative effort between a graphical programming language team and a text-based C language programming team to verify the advantages of using a graphical programming language approach. With approximately eight weeks of funding over a period of three months, the text-based programming team accomplished about 10% of the basic requirements, while the Macintosh/LabVIEW team accomplished about 150%, having gone beyond the original requirements to simulate a telemetry stream and provide utility programs. This application verified that using graphical programming can significantly reduce software development time. As a result of this initial effort, additional follow-on work was awarded to the graphical programming team.

graphical user interface LabVIEW graphical program↗

SX Tank Farm Interim Surface Barrier Vadose Zone Monitoring

The Hanford Site, in southeastern Washington State, has 149 underground single-shell tanks to store hazardous radioactive waste. A number of these tanks and their associated infrastructure (e.g., pipelines, diversion boxes) have leaked. While some of the leaked waste has entered the groundwater, the majority still resides in the vadose zone. Corrective measures are being taken to mitigate the groundwater impacts from past leaks and spills from contaminants that still reside within the vadose zone. Washington River Protection Solutions, LLC, constructed two interim surface barriers (identified as south and north ISBs) in 2018 over the southern portion of the 241-SX Tank Farm to minimize the migration of the residual contaminants in the vadose zone. Two monitoring instrument nests were installed in 2018 and the data acquisition system was put into function in September 2019. This document summarizes the monitoring methods, the instrument calibration and installation, and the vadose zone monitoring plan for the interim barriers in the SX tank farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Controls Data Acquisition System

Measurement and Controls Data Acquisition System (MCDAS) is an application program that integrates the functions of two stand-alone programs: one for acquisition of data, the other for controls. MCDAS facilitates and improves testing of complex engineering systems by helping to perform calibration and setup of test systems and acquisition, dissemination, and processing of data. Features of MCDAS include an intuitive, user-friendly graphical user interface, a capability for acquiring data at rates greater than previously possible, cooperation between the data-acquisition software subsystem and alarm-checking and analytical components of the control software subsystem, and a capability for dissemination of data through fiber optics and virtual and wide-area networks, including networks that contain hand-held display units. The integration of the data acquisition and control software offers a safety advantage by making alarm information available to the control software in a more timely manner. By enabling the use of hand-held devices, MCDAS reduces the time spent by technicians asking for screen updates to determine effects of setup actions. Previously recorded data can be processed without interruption to current acquisition of data. Analysts can continue to view test parameters while test-data files are being generated.

Hall, Rick↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

User's guide to programming fault injection and data acquisition in the SIFT environment

Described are the features, command language, and functional design of the SIFT (Software Implemented Fault Tolerance) fault injection and data acquisition interface software. The document is also intended to assist and guide the SIFT user in defining, developing, and executing SIFT fault injection experiments and the subsequent collection and reduction of that fault injection data. It is also intended to be used in conjunction with the SIFT User's Guide (NASA Technical Memorandum 86289) for reference to SIFT system commands, procedures and functions, and overall guidance in SIFT system programming.

Elks, Carl R.↗

Assessment of Tumor Response to the Vascular Disrupting Agents 5,6-Dimethylxanthenone-4-Acetic Acid or Combretastatin-A4-Phosphate by Intrinsic Susceptibility Magnetic Resonance Imaging

Purpose: To investigate the use of the transverse magnetic resonance imaging (MRI) relaxation rate R{sub 2}* (s{sup -1}) as a biomarker of tumor vascular response to monitor vascular disrupting agent (VDA) therapy. Methods and Materials: Multigradient echo MRI was used to quantify R{sub 2}* in rat GH3 prolactinomas. R{sub 2}* is a sensitive index of deoxyhemoglobin in the blood and can therefore be used to give an index of tissue oxygenation. Tumor R{sub 2}* was measured before and up to 35 min after treatment, and 24 h after treatment with either 350 mg/kg 5,6-dimethylxanthenone-4-acetic acid (DMXAA) or 100 mg/kg combretastatin-A4-phosphate (CA4P). After acquisition of the MRI data, functional tumor blood vessels remaining after VDA treatment were quantified using fluorescence microscopy of the perfusion marker Hoechst 33342. Results: DMXAA induced a transient, significant (p < 0.05) increase in tumor R{sub 2}* 7 min after treatment, whereas CA4P induced no significant changes in tumor R{sub 2}* over the first 35 min. Twenty-four hours after treatment, some DMXAA-treated tumors demonstrated a decrease in R{sub 2}*, but overall, reduction in R{sub 2}* was not significant for this cohort. Tumors treated with CA4P showed a significant (p < 0.05) reduction in R{sub 2}* 24 h after treatment. The degree of Hoechst 33342 uptake was associated with the degree of R{sub 2}* reduction at 24 h for both agents. Conclusions: The reduction in tumor R{sub 2}* or deoxyhemoglobin levels 24 h after VDA treatment was a result of reduced blood volume caused by prolonged vascular collapse. Our results suggest that DMXAA was less effective than CA4P in this rat tumor model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MEASURING THE CLUMP MASS FUNCTION IN THE AGE OF SCUBA2, HERSCHEL, AND ALMA

We use simulated images of star-forming regions to explore the effects of various image acquisition techniques on the derived clump mass function. In particular, we focus on the effects of finite image angular resolution, the presence of noise, and spatial filtering. We find that, even when the image has been so heavily degraded with added noise and lowered angular resolution that the clumps it contains clearly no longer correspond to pre-stellar cores, still the clump mass function is typically consistent with the stellar initial mass function within their mutual uncertainties. We explain this result by suggesting that noise, source blending, and spatial filtering all randomly perturb the clump masses, biasing the mass function toward a lognormal form whose high-mass end mimics a Salpeter power law. We argue that this is a consequence of the central limit theorem and that it strongly limits our ability to accurately measure the true mass function of the clumps. We support this conclusion by showing that the characteristic mass scale of the clump mass function, represented by the 'break mass', scales as a simple function of the angular resolution of the image from which the clump mass function is derived. This strongly constrains our ability to use the clump mass function to derive a star formation efficiency. We discuss the potential and limitations of the current and next generation of instruments for measuring the clump mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

A Robotics Enabled Eddy Current Testing System for Autonomous Inspection of Heat Exchanger Tubes

The objective of the project is to develop a robotics enabled eddy current testing system (REECTS) in automatic probe deployment, inspection, and data acquisition and analysis. The main functions of the REECTS are to: 1) identify geometry and locations of heat exchange tubes with assistance of an imaging recognition system; 2) precisely control the position and motion speed of ECT probes by an adaptive control system; 3) facilitate data analysis and real-time decision making for autonomous inspection assisted by machine learning algorithms.

20 FOSSIL-FUELED POWER PLANTS↗

System measurements of a CO2 laser communications link

Measurements were made under simulated operating conditions to establish the capability of a CO2 laser transmitting heterodyne receiver link to acquire weak laser transmitter beams and maintain spatial tracking during communications. For the case of a synchronous satellite-to-earth station link, analysis and laboratory measurements indicate that the infrared heterodyne receiver subsystem is capable of performing the acquisition, acquisition confirm, and spatial tracking functions at IF signal-to-noise ratio of -17 dB. For the case of a low-altitude satellite-to-earth station link, the laser transmit signal is Doppler-shifted due to the difference in relative velocity of the two stations. The resultant Doppler frequency shift varies with time and must be spectrally acquired and tracked.

Peyton, B. J.↗

Effect of Vibration on Retention Characteristics of Screen Acquisition Systems

An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.

Tegart, J. R.↗

An Imaging Infrared (IIR) seeker using a microprogrammed processor

A recently developed Imaging Infrared Seeker uses a microprogrammed processor to perform gimbal servo control and system interface while performing the seeker functions of automatic target detection, acquisition, and tracking. The automatic detection mode requires up to 80% of the available capability of a high performance microprogrammed processor. Although system complexity was increased significantly, this approach can be cost effective when the basic computation capacity is already available.

Richmond, K. V.↗

The Spacelab Experiment Interface Device (SEID)

The Spacelab experiment interface device (SEID) is described which simulates the electrical, and logical connections of the Spacelab remote acquisition unit (RAU), the interface functions of the Spacelab experiment computer software, and the electrical aspects of the high rate multiplexer. Simulated RAU interfaces include PCM serial channels (up to four), user time clock (UTC), flexible inputs (up to 128) and discrete outputs (up to 64). Connectors are logically compatible with the rau. be instructed to execute sequences of input/output commands to the RAU, similar to those performed during flight. This approximation of the experiment computer software is adequate to detect interface problems and prevent these from occurring during Spacelab payload integration. The SEID hardware is a microprocessor based system, utilizing an 8085 microprocessor with 6K of PROM and 4K of static RAM. The basic unit is augmented with an LSI-11 microcomputer to provide disk storage and a more dynamic environment for generation of control data. A simulation of the general monitoring loop is provided to emulate Spacelab system timing.

Kallus, R.↗

Instrumentation, data acquisition and reduction for a large spaceborne helium dewar

The data acquisition system monitors five types of transducers: (1) platinum and germanium resistance thermometers; (2) superconducting liquid level indicators for both cryogen tanks; (3) pressure transducers for both tanks; (4) strain gauges at critical structural locations; and (5) flowmeters for monitoring cryogen tank boiloff which are linear voltage output transducers. All the transducers produce a voltage proportional to the parameter they measure; this is routed to a single six and one-half digit voltmeter by way of an 80-channel multiplexer. The data acquisition program has six main functions: (1) definition and modification of the channels to be stimulated; (2) sensor stimulation and measurement; (3) raw data storage; (4) raw data conversion; (5) real-time formatting and output of raw or converted data; and (6) editing. The heart of the program is a driver section that represents approximately 20 percent of the code. The driver mode sequences and controls the six main functions.

Brooks, W. F.↗