Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Assessment of Spectroscopic, Real-time Ion Thruster Grid Erosion-rate Measurements

The success of the ion thruster on the Deep Space One mission has opened the gate to the use of primary ion propulsion. Many of the projected planetary missions require throughput and specific impulse beyond those qualified to date. Spectroscopic, real-time ion thruster grid erosion-rate measurements are currently in development at the NASA Glenn Research Center. A preliminary investigation of the emission spectra from an NSTAR derivative thruster with titanium grid was conducted. Some titanium lines were observed in the discharge chamber; however, the signals were too weak to estimate the erosion of the screen grid. Nevertheless, this technique appears to be the only non-intrusive real-time means to evaluate screen grid erosion, and improvement of the collection optics is proposed. Direct examination of the erosion species using laser-induced fluorescence (LIF) was determined to be the best method for a real-time accelerator grid erosion diagnostic. An approach for a quantitative LIF diagnostic was presented.

Domonkos, Matthew T.↗

A Non-interceptive Method to Measure Longitudinal Twiss Parameters of a Beam in a Hadron Linear Accelerator using Beam Position Monitors

A new method of measuring of the RMS longitudinal Twiss parameters of a beam in linear accelerators is presented. It is based on using signals from beam position monitors (BPM) sensitive to the second order moment of the longitudinal charge distribution in the bunch. The applicability of the method is demonstrated on the superconducting section of the Oak Ridge Spallation Neutron Source (SNS) linear accelerator. The results are compared to a direct measurement of the bunch longitudinal profiles using an interceptive bunch shape monitor (BSM) in the linac warm section of the same accelerator. Limitations of the method are discussed. The method is fast and simple, and can be used to obtain the initial parameters for the longitudinal matching in linear accelerators where interceptive diagnostics are not desirable.

Aleksandrov, Alexander V↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

In general, the inherent statistical variances in the laser-driven plasma accelerators (LPAs) and self-amplified spontaneous emission (SASE) free electron lasers (FELs) motivate the use of single-shot diagnostics. In addition, the microbunching phenomenon in each is also variable, so coherent optical transition radiation (COTR) techniques also warrant single-shot evaluations. In both cases, the enhancements of the signals enable optical beam splitters to be used to direct light to the different measuring devices for electron beam size, divergence, spectral content, and/or bunch length as appropriate. COTR Interferometry (COTRI) modelling results for the pre-buncher case at 266 nm and for the LPA case at 633 nm are presented. In addition, examples of few-micron beam size and sub-mrad beam divergence measurements from a single shot of an LPA are reported.

43 PARTICLE ACCELERATORS↗

Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth-telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented.

Rosell, F. E., Jr.↗

Advanced X-Band Test Accelerator for High Brightness Electron and Gamma Ray Beams

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

43 PARTICLE ACCELERATORS↗

ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

42 ENGINEERING↗

Kr II laser-induced fluorescence for measuring plasma acceleration

We present the application of laser-induced fluorescence of singly ionized krypton as a diagnostic technique for quantifying the electrostatic acceleration within the discharge of a laboratory cross-field plasma accelerator also known as a Hall effect thruster, which has heritage as spacecraft propulsion. The 728.98 nm Kr II transition from the metastable 5d{sup 4}D{sub 7/2} to the 5p{sup 4}P{sub 5/2}{sup Ring-Operator} state was used for the measurement of laser-induced fluorescence within the plasma discharge. From these measurements, it is possible to measure velocity as krypton ions are accelerated from near rest to approximately 21 km/s (190 eV). Ion temperature and the ion velocity distributions may also be extracted from the fluorescence data since available hyperfine splitting data allow for the Kr II 5d{sup 4}D{sub 7/2}-5p{sup 4}P{sub 5/2}{sup Ring-Operator} transition lineshape to be modeled. From the analysis, the fluorescence lineshape appears to be a reasonable estimate for the relatively broad ion velocity distributions. However, due to an apparent overlap of the ion creation and acceleration regions within the discharge, the distributed velocity distributions increase ion temperature determination uncertainty significantly. Using the most probable ion velocity as a representative, or characteristic, measure of the ion acceleration, overall propellant energy deposition, and effective electric fields may be calculated. With this diagnostic technique, it is possible to nonintrusively characterize the ion acceleration both within the discharge and in the plume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical, x-ray and microwave diagnostics

Laser-driven ion acceleration is a new approach for the particles acceleration, which allows obtaining ion beams with unique properties, such as short burst duration, large particle number, small size source size, low transverse emittance. Currently, two main acceleration mechanisms have been identified and investigated: target normal sheath acceleration (TNSA) and radiation pressure acceleration (RPA). Electrons dynamics and energies are strongly coupled to these acceleration mechanisms and they can be investigated with optical and X-ray techniques. The main aim of these studies are the identification of few physical observables that can be directly correlated to the proton emission obtained (in terms of reproducibility and intensity) in operations with different target material and structure and laser-target interaction parameters.

43 PARTICLE ACCELERATORS↗

The DARHTAcquisition, Archival, Analysis, And Instrument Control System (DAAAC), And Network Infrastructure

The Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) at Los Alamos National Laboratory is the world's most advanced weapons test facility. DARHT contains two linear accelerators for producing flash radiographs of hydrodynamic experiments. High-speed electronics and optical instrumentation are used for triggering the accelerators and collecting accelerator data. Efficient and effective diagnostics provide basic information needed to routinely tune the accelerators for peak radiographic performance, and to successfully monitor the accelerators performance. DARHT's server and network infrastructure is a key element in providing shot related data storage and retrieval for successfully executing radiographic experiments. This paper will outline the elaborate Data Acquisition, Archival, Analysis, and Instrument Control System (DAAAC), as well as the server and network infrastructure for both accelerators.

43 PARTICLE ACCELERATORS↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Resolution study of higher-order-mode-based beam position diagnostics using custom-built electronics in strongly coupled 3.9-GHz multi-cavity accelerating module

Beam-excited higher order modes (HOMs) can provide remote diagnostics information of the beam position and cavity misalignment. In this paper we report on recent studies on the resolution with specially selected series of modes with custom-built electronics. This constitutes the first report of measurements of these cavities in which we obtained a resolution of 20 micron in beam offset. Details of the setup of the electronics and HOM measurements are provided.

43 PARTICLE ACCELERATORS↗

Thomson Parabola Spectrometer: a powerful tool to get on-line plasma information

In this contribution we report the results of an experimental measurement performed with a TPS developed at INFN-LNS within the ELIMED project, by means of a powerful and self-consistent technique as a diagnostic tool for the ionic acceleration study in laser-generated-plasmas. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Acceleration in Solar Flares

Solar flares are among the most energetic and interesting phenomena in the Solar system, releasing up to 1032 ergs of energy on timescales of several tens of seconds to several tens of minutes. Much of this energy is in the form of suprathermal electrons and ions, which remain trapped at the Sun and produce a wide variety of radiations, as well as escape into interplanetary space, where they can be directly observed. The radiation from trapped particles consists in general of (1) continuum emission; (2) narrow gamma-ray nuclear deexcitation lines; and (3) high-energy neutrons observed in space or by ground-based neutron monitors. The particles that escape into space consist of both electrons and ions, which often have compositions quite different than that of the ambient solar atmosphere. Flares thus present many diagnostics of the particle acceleration mechanism(s), the identification of which is the ultimate goal of flare research. Moreover, flares in fact offer the only opportunity in astrophysics to study the simultaneous energization of both electrons and ions. Hopefully, an understanding of flares with their wealth of diagnostic data will lead to a better understanding of particle acceleration at other sites in the Universe. It is now generally accepted that flares are roughly divided into two classes: impulsive and gradual. Gradual events are large, occur high in the corona, have long-duration soft and hard X-rays and gamma rays, are electron poor, are associated with Type II radio emission and coronal mass ejections (CMEs), and produce energetic ions with coronal abundance ratios. Impulsive events are more compact, occur lower in the corona, produce short-duration radiation, and exhibit dramatic abundance enhancements in the energetic ions. Their He-3/He-4 ratio is - 1, which is a huge increase over the coronal value of about 5 x 10(exp -4), and they also posses smaller but still significant enhancements of Ne, Mg, Si, and Fe relative to He-4, C, N, and O. Specifically, above about 1 MeV nucleon(exp -1), the ratio of Fe to O is about 8 times larger than in the corona or in gradual flares, while the ratio of Ne, Mg, and Si to O is about 3 times higher; He-4, C, N, and 0 are not enchanced with respect to each other. In addition to these elemental enhancements, Ne and Mg have isotopic enhancements as well. The general scenario that has emerged from these (and other) observations is that energetic particles in gradual events are accelerated by a CME-driven shock, while those particles in impulsive events are accelerated by another mechanism(s).

Miller, James A.↗