Aerosol Measurement from Plasma Arc Torch Cuts on Various Metal for D and D Workers' Internal Dose Calculation - 20253
When dismantling a nuclear power plant, structures must be cut to reduce size. The cutting of radioactive material produces radioactive aerosols, which pose a health risk including radiation risk to site workers and the general public. However, due to a lack of research on the physical and chemical characteristics of aerosols produced in these processes, the calculation of internal dose in the event of an expected or unexpected accident is inaccurate. For the measurement of aerosols generated from cutting for internal dose calculations, we measured the number concentration distribution and nuclide distribution of aerosols from plasma arc cutting in a laboratory experimental setup, considering isokinetic sampling and automatic cutting. The results may suggest internal dose assessment without characteristics of radioactive aerosol has uncertainty and the possibility of being undervalued. (authors)