Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

MIDAS, prototype Multivariate Interactive Digital Analysis System, phase 1. Volume 3: Wiring diagrams

The Midas System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughput. The hardware and software generated in Phase I of the overall program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating at 2 x 100,000 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. The MIDAS construction and wiring diagrams are given.

Kriegler, F. J.↗

Damping phenomena in a wire rope vibration isolation system

A study is presented of the dynamic characteristics of a wire rope vibration isolation system constructed with helical isolators, with emphasis placed on the analytical modeling of damping mechanisms in the system. An experimental investigation is described in which the static stiffness curve, hysteresis curves, phase plane trajectories, and frequency response curves are obtained. A semiempirical model having nonlinear stiffness, nth-power velocity damping, and variable Coulomb friction damping is developed, and the results are compared to experimental data. Several observations and conclusions are made about the dynamic phenomena in a typical wire rope vibration isolation system based on the experimental and semiempirical results.

Tinker, M. L.↗

Selective polarization of nuclear spins in a wire-like quantum Hall system

Nuclear spins are polarized selectively in a mesoscopic wire-like quantum Hall system by using the fractional quantum Hall system at Landau level filling factor nu = 2/3. The nuclear spin polarized region is limited by setting the filling factor in the wire to 2/3, while leaving the filling factor in the bulk away from 2/3. The longitudinal relaxation rate of selectively polarized nuclear spins probes electron spin properties in the wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data processing for water monitoring system

Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

Monford, L.↗

Flight Evaluation of the Army/NASA Variable Stability Fly-by-Wire Rotorcraft Aircrew Systems Concept Airborne Laboratory (RASCAL) JUH-60A

NASA Ames Research Center and the U.S. Army Aeroflight dynamics Directorate (AFDD) have performed initial flight evaluations of the Research Flight Control System (RFCS) integrated into the Army/NASA Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-GOA. The highly modified JUH-GOA Black Hawk helicopter is a full authority, high bandwidth, variable stability, in-flight simulator designed to support development of advanced flight control, sensor, and integrated display and control technologies in a fail safe environment. Preparation for flight test required an extensive hazard analysis and ground testing to ensure proper system operation. A hardware in the loop development facility was utilized to evaluate control law stability following software changes, assess servo hardover upset conditions during manual and monitor disengagements and provide pilot familiarization of test techniques and software changes prior to flight. First engagement of the RFCS was conducted on 31 Aug 2001. RFCS transfer system operation, envelope expansion and a limited rate monitor evaluation have been completed with low bandwidth and model following control laws. The presentation will discuss the following - System overview including aircraft modifications and integrated development facilities used with the RASCAL facility. - Preliminary hazard identification and mitigation prior to flight test. - Ground testing used to qualify the RFCS transfer system and verify fault monitor operation. - Flight test results of low-bandwidth and model following control law evaluations including maneuver agility, control limitations, fault monitor reliability, and recovery from manual and monitor disengagement. - Lessons learned including test techniques using a passive three-axis sidearm controller, the value of the development facility in reducing risk and crew coordination issues related to the operation of a full authority, variable stability platform. - Future research and modifications planned for the RASCAL aircraft.

Dave Arterburn↗

Flywheel system using wire-wound rotor

A flywheel is described having a rotor constructed of wire wound onto a central form. The wire is prestressed, thus mitigating stresses that occur during operation. In another aspect, the flywheel incorporates a low-loss motor using electrically non-conducting permanent magnets.

25 ENERGY STORAGE↗

Phase-Sensing Guidance for Wire-Following Vehicles

Guidance system for wire-following vehicles tested successfully at speeds exceeding 50 mi/h (80 km/h) on difficult 1 mile (1.6km) course. Unlike previous sensors that compare amplitudes of signals picked up from guide wire, new system compares signal phases. Array of coils is mounted in line along front bumper of vehicle and monitors electromagnetic signal radiating from wire. Guide wire on ground beneath vehicle carrier 6- to 7-kHz alternating current.

Hansen, G. R.↗

Durability Evaluation of a Thin Film Sensor System With Enhanced Lead Wire Attachments on SiC/SiC Ceramic Matrix Composites

An advanced thin film sensor system instrumented on silicon carbide (SiC) fiber reinforced SiC matrix ceramic matrix composites (SiC/SiC CMCs), was evaluated in a Mach 0.3 burner rig in order to determine its durability to monitor material/component surface temperature in harsh environments. The sensor system included thermocouples in a thin film form (5 microns thick), fine lead wires (75 microns diameter), and the bonds between these wires and the thin films. Other critical components of the overall system were the heavy, swaged lead wire cable (500 microns diameter) that contained the fine lead wires and was connected to the temperature readout, and ceramic attachments which were bonded onto the CMCs for the purpose of securing the lead wire cables, The newly developed ceramic attachment features a combination of hoops made of monolithic SiC or SiC/SiC CMC (which are joined to the test article) and high temperature ceramic cement. Two instrumented CMC panels were tested in a burner rig for a total of 40 cycles to 1150 C (2100 F). A cycle consisted of rapid heating to 1150 C (2100 F), a 5 minute hold at 1150 C (2100 F), and then cooling down to room temperature in 2 minutes. The thin film sensor systems provided repeatable temperature measurements for a maximum of 25 thermal cycles. Two of the monolithic SiC hoops debonded during the sensor fabrication process and two of the SiC/SiC CMC hoops failed during testing. The hoops filled with ceramic cement, however, showed no sign of detachment after 40 thermal cycle test. The primary failure mechanism of this sensor system was the loss of the fine lead wire-to-thin film connection, which either due to detachment of the fine lead wires from the thin film thermocouples or breakage of the fine wire.

Lei, Jih-Fen↗

Interface for the rapid analysis of liquid samples by accelerator mass spectrometry

An interface for the analysis of liquid sample having carbon content by an accelerator mass spectrometer including a wire, defects on the wire, a system for moving the wire, a droplet maker for producing droplets of the liquid sample and placing the droplets of the liquid sample on the wire in the defects, a system that converts the carbon content of the droplets of the liquid sample to carbon dioxide gas in a helium stream, and a gas-accepting ion source connected to the accelerator mass spectrometer that receives the carbon dioxide gas of the sample in a helium stream and introduces the carbon dioxide gas of the sample into the accelerator mass spectrometer.

47 OTHER INSTRUMENTATION↗

System and method for evaluating a wire conductor

A method of evaluating an electrically conductive wire segment having an insulated intermediate portion and non-insulated ends includes passing the insulated portion of the wire segment through an electrically conductive brush. According to the method, an electrical potential is established on the brush by a power source. The method also includes determining a value of electrical current that is conducted through the wire segment by the brush when the potential is established on the brush. The method additionally includes comparing the value of electrical current conducted through the wire segment with a predetermined current value to thereby evaluate the wire segment. A system for evaluating an electrically conductive wire segment is also disclosed.

42 ENGINEERING↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

Direct sequence spread spectrum CDMA in shared spectrum applications

Personal Communication Network (PCN) is an entirely wireless communication system with the capability of assessing the wired telephone system to reach anyone processing only a wired telephone. It is expected to compete with the existing mobile cellular system which connects directly to the wired telephone system. While many PCN systems employ TDMA technology, the PCN system described here uses Broadband CDMA (BCDMA(sup SM)) which is capable of sharing the spectrum with other users and which is extremely resistant to fading caused by multipath.

Schilling, Donald L.↗