Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WATER PERMEATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Development of a tritium recovery system from CANDU tritium removal facility

The main purpose of the Tritium Recovery System (TRS) is to reduce to a maximum possible extent the release of tritium from the facility following a tritium release in confinement boundaries and also to have provisions to recover both elemental and vapors tritium from the purging gases during maintenance and components replacement from various systems processing tritium. This work/paper proposes a configuration of Tritium Recovery System wherein elemental tritium and water vapors are recovered in a separated, parallel manner. The proposed TRS configuration is a combination of permeators, a platinum microreactor (MR) and a trickle bed reactor (TBR) and consists of two branches: one branch for elemental tritium recovery from tritiated deuterium gas and the second one for tritium recovery from streams containing a significant amount of water vapours but a low amount, below 5%, of tritiated gas. The two branches shall work in a complementary manner in such a way that the bleed stream from the permeators shall be further processed in the MR and TBR in view of achieving the required decontamination level. A preliminary evaluation of the proposed TRS in comparison with state of the art tritium recovery system from tritium processing facilities is also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selective permeation up a chemical potential gradient to enable an unusual solvent purification modality

The need for energy-efficient recovery of organic solutes from aqueous streams is becoming more urgent as chemical manufacturing transitions toward nonconventional and bio-based feedstocks and processes. In addition to this, many aqueous waste streams contain recalcitrant organic contaminants, such as pharmaceuticals, industrial solvents, and personal care products, that must be removed prior to reuse. We observe that rigid carbon membrane materials can remove and concentrate organic contaminants via an unusual liquid-phase membrane permeation modality. Surprisingly, detailed thermodynamic calculations on the chemical potential of the organic contaminant reveal that the organic species has a higher chemical potential on the permeate side of the membrane than on the feed side of the membrane. This unusual observation challenges conventional membrane transport theory that posits that all permeating species move from high chemical potential states to lower chemical potential states. Based on experimental measurements, we hypothesize that the organic is concentrated in the membrane relative to water via favorable binding interactions between the organic and the carbon membrane. The concentrated organic is then swept through the membrane via the bulk flow of water in a modality known as “sorp-vection.” We highlight via simplified nonequilibrium thermodynamic models that this “uphill” chemical potential permeation of the organic does not result in second-law violations and can be deduced via measurements of the organic and water sorption and diffusion rates into the carbon membrane. Moreover, this work identifies the need to consider such nonidealities when incorporating unique, rigid materials for the separations of aqueous waste streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tritium Pressure Enhancement on the TPBAR Cladding by Physical Processes at the Getter

Tritium for the U.S. nuclear weapon stockpile is produced in tritium producing burnable absorber rods (TPBARs) inserted into Tennessee Valley Authoritys (TVA) light-water nuclear reactors. The rods are stainless steel tubes with a permeation barrier coating and internal components that generate and contain the tritium. The TPBAR incorporates a Ni-plated Zircoloy getter tube to capture tritium and prevent it from reaching the rod cladding and permeating into the environment. Under the conventional view of getter behavior, the tritium pressure outside the getter tube is expected to be limited to the equilibrium vapor pressure of Zr hydride at the temperature of the rod as long as the total hydrogen concentration remains below the capacity of the hydride. Since the tritium pressure is higher within the rod core, this behavior relies on the thin getters ability to hold off a differential tritium pressure. The effective tritium pressure on the cladding can also be enhanced by isotope exchange. Hydrogen ingress through the cladding from the reactor coolant creates a hydrogen pressure on the outer surface of the getter that can exchange with tritium, allowing the tritium partial pressure to increase toward this hydrogen gettering pressure. The goal of this work was to use laboratory-scale experiments to examine these mechanisms and create a model of getter behavior that describes tritium transport within the TPBAR. A third mechanism wherein the concentration at the outer surface of the getter is increased by the temperature gradient within the getter tube wall (the Soret effect) is not experimentally tested but is captured in the model. While not conclusively demonstrated by the experiments due to low pressure, high temperature, and small gap volume conditions, the model shows that when combined, the three mechanisms can explain both the magnitude and time dependence of the tritium release observed for reactor fuel assemblies with TPBARs. The model also shows how various modifications of the TPBAR design can reduce this tritium release into the environment.

07 ISOTOPE AND RADIATION SOURCES↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Electric Power Research Institute (EPRI) [Abstract]

Carbon dioxide (CO 2 ) capture from flue gas generated by fossil fuel-fired power plants has been proposed as an efficient approach to limit CO 2 emissions to the atmosphere. Due to the high cyclic CO 2 sorption capacity, well-tuned adsorption chemistry and non-volatility, solid sorbents are widely studied for CO 2 capture processes such as pressure swing adsorption (PSA) and temperature swing adsorption (TSA). Realistic applications of traditional solid sorbent systems face many challenges since moisture and heat management are problematic and solid-solid heat exchange is inefficient. Recently, a novel solid sorbent system, the sorbent polymer composite (SPC), has been developed to overcome those challenges in an energy-saving CO 2 capture process using TSA membrane contactors. A SPC material is comprised of a powdered solid sorbent embedded into a hydrophobic and porous polymer matrix. It allows gases to permeate through and achieve full contact with the sorbents while rejecting water moisture in the CO 2 capture process. In this collaborative research, NETL will conduct performance testing of a novel SPC material and EPRI will conduct a cost analysis based on that performance data.

20 FOSSIL-FUELED POWER PLANTS↗

Machine learning models of intermittent operation of RO wellhead water treatment for salinity reduction and nitrate removal

Machine learning models were developed for intermittent multi-mode operation of a wellhead reverse osmosis water purification and desalination system to predict salt passage, nitrate passage, and permeate flux. The models, based on long short-term memory (LSTM) recurrent neural network (RNN) architecture, included an attention mechanism to increase model performance in proximity of the regulatory limit for nitrate. Training and testing of the models for the Startup, Production, Shutdown and Flushing operational modes were based on operational data (consisting of 22 process variables per data sample) acquired every 2–5 s over a six-month period. The significant sets of model input attributes for the different operational modes were assessed via Spearman ranking correlation, Self-Organizing Map (SOM) analysis and feed forward feature selection (FFFS). Although the variability of nitrate passage, salt passage and permeate flux was significant over the four operational modes, prediction performance for the three outcomes were with R2 and Average Absolute Relative Error (AARE) of 0.78–0.95 and 2.96–6.16 %, respectively. Model updates post membrane elements replacement demonstrated similar levels of prediction accuracy. The study results suggest that there is merit in exploring the utility of multi-mode models for sensor fault detection, data imputation, and for potential use in model-predictive control.

Intermittent RO operation↗

Mechanism of unassisted ion transport across membrane bilayers

To establish how charged species move from water to the nonpolar membrane interior and to determine the energetic and structural effects accompanying this process, we performed molecular dynamics simulations of the transport of Na+ and Cl- across a lipid bilayer located between two water lamellae. The total length of molecular dynamics trajectories generated for each ion was 10 ns. Our simulations demonstrate that permeation of ions into the membrane is accompanied by the formation of deep, asymmetric thinning defects in the bilayer, whereby polar lipid head groups and water penetrate the nonpolar membrane interior. Once the ion crosses the midplane of the bilayer the deformation "switches sides"; the initial defect slowly relaxes, and a defect forms in the outgoing side of the bilayer. As a result, the ion remains well solvated during the process; the total number of oxygen atoms from water and lipid head groups in the first solvation shell remains constant. A similar membrane deformation is formed when the ion is instantaneously inserted into the interior of the bilayer. The formation of defects considerably lowers the free energy barrier to transfer of the ion across the bilayer and, consequently, increases the permeabilities of the membrane to ions, compared to the rigid, planar structure, by approximately 14 orders of magnitude. Our results have implications for drug delivery using liposomes and peptide insertion into membranes.

NASA Discipline Exobiology↗

Solvent-Induced Swelling Behaviors of Microphase-Separated Polystyrene- block -Poly(ethylene oxide) Thin Films Investigated Using In Situ Spectroscopic Ellipsometry and Single-Molecule Fluorescence Microscopy

Block copolymers have attracted considerable interest in the fields of nanoscience and nanotechnology, because these polymers afford well-defined nanostructures via self-assembly. An in-depth understanding of solvent effects on the physicochemical properties of these microdomains is crucial for their preparation and utilization. Herein, we employed in situ spectroscopic ellipsometry and single-molecule fluorescence techniques to gain detailed insights into microdomain properties in polystyrene-block-poly(ethylene oxide) (PS-b-PEO) films exposed to ethanol- and water-saturated N 2 . We observed a quick increase and a subsequent gradual decrease in the ellipsometric thickness of PS-b-PEO films upon exposure to ethanol-saturated N 2 . This observation was unexpected because ethanol-saturated N 2 induced negligible thickness change for PS and PEO homopolymer films. The similarity in maximum thickness gain observed under ethanol- and water-saturated N 2 implied the swelling of PEO microdomains. Ethanol vapor permeation through the PEO microdomains was supported by the red-shift of the ensemble and single-molecule fluorescence emission of Nile red in PS-b-PEO films. Single-molecule tracking data showed the initial enhancement and subsequent reduction of the diffusion of hydrophilic sulforhodamine B molecules in PS-b-PEO films upon exposure to ethanol-saturated N 2 , consistent with the spectroscopic ellipsometry results. Furthermore, the higher ethanol susceptibility of the PEO microdomains was attributable to their amorphous nature, as shown by FTIR data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular dynamics simulation of water in and around carbon nanotubes: A coarse-grained description

In the present study, we intend to investigate behaviour of water in and around hydrophobic open ended carbon nanotubes (CNTs) using a coarse-grained, core-softened model potential for water. The model potential considered here for water has recently been shown to successfully reproduce dynamic, thermodynamic and structural anomalies of water. The epitome of the study is to understand the incarceration of this coarse-grained water in a single-file carbon nanotube. In order to examine the effect of fluid-water van der Waals interaction on the structure of fluid in and around the nanotube, we have simulated three different CNT-water systems with varying degree of solute-water dispersion interaction. The analyses of the radial one-particle density profiles reveal varying degree of permeation and wetting of the CNT interior depending on the degree of fluid-solute attractive van der Waals interaction. A peak in the radial density profile slightly off the nanotube axis signifies a zigzag chain of water molecule around the CNT axis. The average numbers of water molecules inside the CNT have been shown to increase with the increase in fluid-water attractive dispersion interaction.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordinated Cation Transport in Ti 3 C 2 T x MXene Membranes

Membrane nanofiltration is an attractive strategy for the selective recovery of high-demand metals from wastewater and brine. Effective sieving of ions in aqueous environments will require precise control over membranes’ nanochannel size and chemistry. Ti 3 C 2 T x MXene is an environmentally stable 2D material that can be processed into laminar membranes containing nanoscale interlayer spaces. The MXene interlayer environment depends on the ion species and amount of water intercalated between MXene sheets, and it is the major factor governing permeation and selectivity through MXene membranes. Coordinated ion–ion and ion-interlayer dynamics in the presence of complex mixtures can impact ion permeability and selectivity. Herein, we observe strong competitive effects between different cations (Li + , Na + , and Ca 2+ ) in binary mixtures, resulting in reduced selectivity when compared with single-salt permeability ratios. X-ray diffraction, molecular dynamics, and density functional theory simulations support the conclusion that cations with stronger attraction to MXene flakes can preferentially occupy the MXene nanochannels and hinder other ions via charge or size exclusion. In conclusion, elucidation of ion transport behavior in MXene under complex conditions will allow for more rational design of efficient ion-sieving membranes.

2D Materials↗

Development of a preprototype hyperfiltration wash water recovery subsystem

The use of hyperfiltration as a mode of reclamation of waste water on board an extended mission spacecraft was investigated. Two basic approaches are considered with respect to hyperfiltration of wash water recovery. The initial approach involves the use of a hollow fiber permeator and a tubular module, operating at ambient temperature. In this system, relatively large doses of biocides are used to control microbial activity. Since biocides require a long contact time, and many have adverse dematological effects as well as many interact with membrane material, a second approach is considered which involves operating at pasturization temperature.

Source record↗

Chemical Compatibility of Conventional Geo-synthetic Clay Liners to Aggressive Low-Level Radioactive Waste Leachate - 17296

representative of leachates in low-level radioactive waste (LLW) disposal facilities affected the hydraulic conductivity of a conventional sodium-bentonite (Na-B) geo-synthetic clay liner (GCL) used in composite liner systems. One leachate was highly alkaline (H-pH) and the other had a low abundance of monovalent cations relative to divalent cations (L-RMD). Tests were also conducted with a typical radioactive synthetic leachate (RSL) and with deionized (DI) water as control. Na-B from the GCL had a swell index of 24 mL/2 g in RSL, 22 mL/2 g in H-pH leachate, and 16 mL/2 g in L-RMD leachate, whereas the swell index was 36 mL/2 g in DI water. Hydraulic conductivity tests were conducted in flexible-wall permeameters using the falling headwater with an effective confining stress at 20 kPa. Hydraulic conductivity of Na-B GCL was low when permeated with RSL (1.8 x 10-10 m/s) and H-pH leachate (2.4 x 10{sup -10} m/s), but higher than the hydraulic conductivity to DI water (2.5 x10{sup -11} m/s). The GCL was two orders of magnitude more permeable when permeated with L-RMD leachate (7.9 x 10{sup -8} m/s). The higher hydraulic conductivity of the GCL to the leachates is attributed to reduced swelling of the Na-B in leachates with higher ionic strength solution (H-pH, RSL) or a predominance of divalent cations (L-RMD). Increasing the effective confining stress from 20 to 450 kPa reduced the hydraulic conductivity approximately two orders of magnitude for the L-RMD and H-pH leachates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of ion specific media to treat Sr-contaminated water at Fukushima Daiichi Nuclear Power Plant - 15486

Since April of 2011, Kurion, Inc. contracted with the Tokyo Electric Power Company (TEPCO) to remediate cooling water using Ion Specific Media targeting cesium (Cs). The effluent of the Cs-sorption systems routed into a reverse osmosis (RO) system. While the RO permeate was recirculated into the cooling loop, the RO reject was captured in carbon-steel tanks. However, the cesium-extracted tank water at Fukushima Daiichi also has a high strontium (Sr) activity (∼4 x 10{sup 5} Bq/mL) and needs to be reduced to lower the onsite and boundary doses. To treat this highly contaminated water, Kurion developed the Kurion Mobile Processing System (KMPS). The KMPS uses a powder batch-contact addition step in concert with a series of ion exchange vessels to decontaminate the high Sr-activity water. Kurion tested and developed several ion specific media to treat the water. Several inorganic media were evaluated in the down-select for the system. Equilibrium batch tests, shortened contact time batch tests and column tests were performed to assess the media depending on water conditions. Two media were selected for KMPS: FAS-P (a powdered zeolite) to reduce Ca{sup 2+} and Sr{sup 2+} concentrations and TS-G (a synthetic titanosilicate) to polish the Sr{sup 2+} downstream. The results of these laboratory tests and their performance in the field will be discussed. The operation of the system has led to the continued reduction of dose at the Fukushima Daiichi nuclear power plant. This system and these media can be applied to other difficult wastewater solutions involving high levels of contaminants and salinity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ammonia Permeation Through Inorganic Membranes

Moisture probes are used in the tritium facility to measure the moisture content of the gas stream. When tritium reacts with nitrogen to form ammonia, the ammonia gas damages the sensitive moisture probe. The gas stream tested during this experiment for moisture probe protection is composed of nitrogen and argon gas in conjunction with ammonia and water vapor. The gas stream is filtered through an inorganic membrane due to the high reactivity of tritium and a residual gas analyzer (RGA) is used to measure the ammonia and water vapor in the gas stream, as well as the permeability of nitrogen and argon through the inorganic membranes. The membranes tested were boron nitride and silver. The permeability was compared for each membrane at different pressures and flow rates. Fourier-transformed infrared spectroscopy (FT-IR) was used to compare the membranes before and after ammonia permeation. Ammonia gas is a byproduct formed from tritium gas reacting with nitrogen in the gas stream, similar to the Haber Process which occurs when hydrogen reacts with nitrogen [2]. The corrosive nature of ammonia damages metals and sensitive instruments such as moisture probes. Moisture probes are essential in various gas and liquid processes for measuring the moisture content of a gas. Membrane research has found that graphene oxide membranes successfully uptake ammonia from the gas stream at a humidity of approximately 30% at which point the pores pin closed, preventing gas permeation. Further research is being conducted to find an inorganic membrane that will prevent ammonia permeation thus circumventing damage to the sensitive moisture probe. The permeation measurements for argon and nitrogen gas and water and ammonia vapor were measured at various pressures of 800, 1000, 1200, 1500, 1800, and 2000 torr. The permeability average (PA) was calculated for each filter using a Barrer calculation. The average permeations for each filter were then compared. The gas composition was measured using the RGA Nitrogen was permeated through the membranes after ammonia permeation and a FT-IR spectrum was obtained. Boron Nitride: As the nitrogen pressure increased, the permeability of the membrane decreased from 800-1200 torr and remained relatively unchanged from 1200-2000 torr. The membrane exhibited a slight decrease in argon permeability from 800-1200 torr and a slight increase from 1500-2000 torr. The boron nitride membrane when permeated with ammonia and nitrogen prevented less ammonia permeation compared to the blank filter. The boron nitride filter demonstrated a decrease in permeability after ammonia permeation. Silver Membrane: When permeated with nitrogen alone, the membrane permeability decreased from 800 torr to 1200 torr. The permeability of the membrane showed little difference as pressure increased from 1200 torr. When permeated with argon, the same phenomenon occurred but on a much smaller scale. When compared to the blank and the boron nitride membranes the silver membrane exhibited significantly lower permeability. This may be in part due to the coating on the silver membrane and differences in pore size of the membranes. During permeation with ammonium hydroxide vapor and nitrogen, the partial pressure of the ammonia increased as compared to the blank membrane. The permeability before and after permeation with ammonia and nitrogen were compared. Permeability values suggested that after being permeated with the ammonia that the permeability for lower pressures increased slightly. There was no significant change in the FT-IR spectrums before and after permeation. Future work: Continue testing various inorganic membranes for ammonia permeation. Further research chemical separation of ammonia from the gas stream, which may prove difficult due to the high reactivity of tritium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane reactor for water detritiation: a parametric study on operating parameters

This paper presents the results of a parametric study done on a single stage finger-type packed-bed membrane reactor (PBMR) used for heavy water vapor de-deuteration. Parametric studies have been done on 3 operating parameters which are: the membrane temperature, the total feed flow rate and the feed composition through D{sub 2}O content variations. Thanks to mass spectrometer analysis of streams leaving the PBMR, speciation of deuterated species was achieved. Measurement of the amounts of each molecular component allowed the calculation of reaction quotient at the packed-bed outlet. While temperature variation mainly influences permeation efficiency, feed flow rate perturbation reveals dependence of conversion and permeation properties to contact time between catalyst and reacting mixture. The study shows that isotopic exchange reactions occurring on the catalyst particles surface are not thermodynamically balanced. Moreover, the variation of the heavy water content in the feed exhibits competition between permeation and conversion kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water as a gas separation membrane

Efficient gas separation membranes are essential for carbon capture, biogas upgrading, and hydrogen purification. Inspired by how plants absorb CO 2 through water, we present a membrane platform that uses liquid water as the selective layer. Hydrophilic sub-100-nm pores stabilize water through strong capillary forces, enabling operation at feed pressures above 72 bar under dry and humid conditions. Selectivity is governed by gas solubility in water, while permeance is tuned by adjusting the water layer thickness. Reducing this thickness below 200 nm yields CO 2 permeances up to 11,600 gas permeation units with CO 2 :N 2 , CO 2 :CH 4 , and CO 2 :H 2 selectivities of 40, 26, and 31, respectively, surpassing the performance of state-of-the-art membranes. Operation is sustained for over a week without water loss, and performance scales using commercially available porous polymer supports under mixed-gas crossflow conditions. Water’s dissolution-based transport avoids saturation and reaction-rate limits, enabling a robust, high-performance, and environmentally benign gas separation platform.

08 HYDROGEN↗

Hydration Mimicry by Membrane Ion Channels

Ions transiting biomembranes might pass readily from water through ion-specific membrane proteins if these protein channels provide environments similar to the aqueous solution hydration environment. In fact, bulk aqueous solution is an important reference condition for the ion permeation process. Assessment of this hydration mimicry concept depends on understanding the hydration structure and free energies of metal ions in water in order to provide a comparison for the membrane channel environment. To refine these considerations, we review local hydration structures of ions in bulk water and the molecular quasi-chemical theory that provides hydration free energies. In doing so, we note some current views of ion binding to membrane channels and suggest new physical chemical calculations and experiments that might further clarify the hydration mimicry concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗