Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hilo Bay Water Resources: Monitoring Water Quality in Hilo Bay, Hawaii to Support Future Community Planning

Designated as an impaired body of water by both state and federal water quality standards, Hilo Bay, Hawaiʻi is highly susceptible to brown water, a condition where the water becomes murky and is associated with excess levels of bacteria, contaminants, and nutrients. A breakwater in Hilo Bay, which was established to protect Hilo town from tsunamis, interferes with water circulation and prolongs the presence of brown water in the bay. The State of Hawaiʻi issues brown water advisories (BWAs) following flash flood warnings, sewage spills, and other events to indicate a public health concern for those who use Hilo Bay for recreation, cultural purposes, and fishing. Due to the elevated public health risk and ecosystem disturbance that brown water poses to Hilo Bay, we partnered with the Hawaiʻi County Office of Sustainability, Climate, Equity, and Resilience (OSCER) to examine the feasibility of using Earth observations (EO) to monitor water quality in the Hilo Bay region. We leveraged data from Sentinel-2 Multispectral Instrument (MSI), Landsat 8 Operational Land Imager (OLI), Landsat 9 OLI-2, and Aqua and Terra Moderate Resolution Imagine Spectroradiometer (MODIS) instruments to identify and assess spatial and temporal patterns of two main water quality parameters, turbidity and chlorophyll-a, during BWAs. We used the Optical Reef and Coastal Area Assessment (ORCAA) tool in Google Earth Engine to process EO data and generate water quality maps and time series. Our study found that increased turbidity levels can be identified by EO data during BWAs. In addition, our map products indicated the presence of several turbidity plumes along the coast, with the highest concentration of turbidity found within Hilo Bay. While chlorophyll-a levels were relatively flat within our study region during BWAs, we found that regional chlorophyll-a patterns could be derived from MODIS chlorophyll-a data in NASA Worldview. Our study’s multi-sensor approach provided valuable insights for how water quality in the Hilo Bay region can be monitored in the future.

remote sensing↗

Air-water and steam-water onset of flooding data at variable pressure in a large diameter tube

An experimental investigation to acquire flooding data for steam-water and air-water fluid pairs in a large-diameter vertical tube at above-atmospheric pressures is being conducted. The experimental program presented herein is the first to use a single test section with controlled boundary conditions for these pairs in a large-diameter vertical tube, enabling consistent comparisons of flooding characteristics. Many data exist for air-water flooding in annular flow within a large-diameter vertical tube and at various pressures. Steam-water flows are of interest for reactor applications but insufficient data are available to enable reliable analysis. Evaluation of the effect of the fluid pair is performed to understand the applicability of the air-water data to steam-water applications. The pressure range for the tests reported herein is 0.1-0.4 MPa (3-45 psig) for the air-water experiments and 0.1-0.2 MPa (3-15 psig) for the steam-water experiments. The steam-water tests were conducted with minimal subcooling to reduce the effect of phase change and permit a more level comparison with the air-water data. All data were taken at the onset of flooding, that is, conditions when flow reversal of the liquid phase first occurs. The data at higher pressures suggest that the momentum transfer necessary for the onset of flooding is achievable with lower superficial gas velocities as the gas density increases. Flooding characteristics are presented in terms of the Kutateladze parameter. If condensation is accounted for, the saturated steam-water data at 0.1 and 0.2 MPa (3 and 15 psig) closely trend with the air-water flooding data. (authors)

42 ENGINEERING↗

Origin of Unusual Acidity and Li+ Diffusivity in a Series of Water-in-Salt Electrolytes.

Superconcentrated aqueous electrolytes ("water-in-salt" electrolytes, or WiSEs) enable various aqueous battery chemistries beyond the voltage limits imposed by the Pourbaix diagram of water. However, their detailed structural and transport properties remain unexplored and could be better understood through added studies. Here, we report on our observations of strong acidity (pH 2.4) induced by lithium bis(trifluoromethane sulfonyl)imide (LiTFSI) at superconcentration (at 20 mol/kg). Multiple nuclear magnetic resonance (NMR) and pulsed-field gradient (PFG) diffusion NMR experiments, density functional theory (DFT) calculations, and molecular dynamics (MD) simulations reveal that such acidity originates from the formation of nanometric ion-rich structures. The experimental and simulation results indicate the separation of water-rich and ion-rich domains at salt concentrations >= 5 m and the acidity arising therefrom is due to deprotonation of water molecules in the ion-rich domains. As such, the ion-rich domain is composed of hydrophobic -CF3 (of TFSI-) and hydrophilic hydroxyl (OH-) groups. At 20 m concentration, the tortuosity and radius of water diffusion channels are estimated to be similar to 10 and similar to 1 nm, respectively, which are close to values obtained from hydrated Nafion membranes that also have hydrophobic polytetrafluoroethylene (PTFE) backbones and hydrophilic channels consisting of SO3- ion cluster networks providing for the transport of ions and water. Thus, we have discovered the structural similarity between WiSE and hydrated Nafion membranes on the nanometer scale.

Han, Kee Sung↗

The role of proton coupled electron transfer in water oxidation

Water oxidation is a key half reaction in energy conversion schemes based on solar fuels and targets such as light driven water splitting or carbon dioxide reduction into CO, other oxygenates, or hydrocarbons. Carrying out these reactions at rates that exceed the rate of solar insolation for the extended periods of time required for useful applications presents a major challenge. Water oxidation is the key “other” half reaction in these schemes and it is dominated by PCET given its multi-electron, multi-proton character, 2H2O → O2 + 4e- + 4H+. Identification of PCET was an offshoot of experiments designed to investigate energy conversion by electron transfer quenching of molecular excited states. The concepts “redox potential leveling” and concerted electron–proton transfer came from measurements on stepwise oxidation of cis-RuII(bpy)2(py)(OH2)2+ to RuIV(bpy)2(py)(O)2+. The Ru “blue dimer”, cis,cis-(bpy)2(H2O)RuORu(OH2)(bpy)24+, was the first designed catalyst for water oxidation. It undergoes oxidative activation by PCET to give the transient (bpy)2(O)RuVORuV(O)(bpy)24+, O-atom attack on water to give a peroxidic intermediate, and further oxidation and O2 release. More recently, a class of single site water oxidation catalysts has been identified, e.g., Ru(tpy)(bpm)(OH2)2+ (tpy is 2,2':6',2''-terpyridine; bpm is 2,2'-bipyrimidine). They undergo stepwise PCET oxidation to RuIV=O2+ or RuV(O)3+ followed by O-atom transfer with formation of peroxidic intermediates which undergo further oxidation and O2 release. PCET plays a key role in the three zones of water oxidation reactivity: oxidative activation, O•••O bond formation, oxidation and O2 release from peroxidic intermediates. Similar schemes have been identified for electrocatalytic water oxidation on oxide electrode surfaces based on phosphonated derivatives such as [Ru(Mebimpy)(4,4'-(PO3H2CH2)2bpy)(OH2)]2+. A PCET barrier to RuIII–OH2+ → RuIV=O2+ oxidation arises from the large difference in pKa values between RuIII–OH2+ and RuIV(OH)3+. On oxide surfaces this oxidation occurs by multiple pathways. Kinetic, mechanistic, and DFT results on single site catalysts reveal a new pathway for the O•••O bond forming step (Atom-Proton Transfer, APT), significant rate enhancements by added proton acceptor bases, and accelerated water oxidation in propylene carbonate as solvent with water added as a stoichiometric reagent. Lessons learned about water oxidation and the role of PCET and concerted pathways appear to have direct relevance for water oxidation in Photosystem II (PSII) with PSII a spectacular example of PCET in action. This includes a key role for Multiple Site-Electron Proton Transfer in oxidative activation of the Oxygen Evolving Complex (OEC) in the S0 → S1 transition in the Kok cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Communication: Hydrogen bonding interactions in water-alcohol mixtures from X-ray absorption spectroscopy

While methanol and ethanol are macroscopically miscible with water, their mixtures exhibit negative excess entropies of mixing. Despite considerable effort in both experiment and theory, there remains significant disagreement regarding the origin of this effect. Different models for the liquid mixture structure have been proposed to address this behavior, including the enhancement of the water hydrogen bonding network around the alcohol hydrophobic groups and microscopic immiscibility or clustering. We have investigated mixtures of methanol, ethanol, and isopropanol with water by liquid microjet X-ray absorption spectroscopy on the oxygen K-edge, an atom-specific probe providing details of both inter- and intra-molecular structure. The measured spectra evidence a significant enhancement of hydrogen bonding originating from the methanol and ethanol hydroxyl groups upon the addition of water. These additional hydrogen bonding interactions would strengthen the liquid-liquid interactions, resulting in additional ordering in the liquid structures and leading to a reduction in entropy and a negative enthalpy of mixing, consistent with existing thermodynamic data. In contrast, the spectra of the isopropanol-water mixtures exhibit an increase in the number of broken alcohol hydrogen bonds for mixtures containing up to 0.5 water mole fraction, an observation consistent with existing enthalpy of mixing data, suggesting that the measured negative excess entropy is a result of clustering or micro-immiscibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Na + -gated water-conducting nanochannels for boosting CO 2 conversion to liquid fuels

Robust, gas-impeding water-conduction nanochannels that can sieve water from small gas molecules such as hydrogen (H 2 ), particularly at high temperature and pressure, are desirable for boosting many important reactions severely restricted by water (the major by-product) both thermodynamically and kinetically. Identifying and constructing such nanochannels into large-area separation membranes without introducing extra defects is challenging. We found that sodium ion (Na + )–gated water-conduction nanochannels could be created by assembling NaA zeolite crystals into a continuous, defect-free separation membrane through a rationally designed method. Highly efficient in situ water removal through water-conduction nanochannels led to a substantial increase in carbon dioxide (CO 2 ) conversion and methanol yield in CO 2 hydrogenation for methanol production.

Science & Technology - Other Topics↗

Reversible structural transformations in supercooled liquid water from 135 to 245 K

Water has many anomalous properties compared to “simple” liquids, and these anomalies are typically enhanced in supercooled water.1-3 While numerous models have been proposed, including the liquid-liquid critical point,4,5 the singularity-free scenario,6 and the stability limit conjecture,1 a molecular-level understanding remains elusive. The main difficulty in determining which, if any, of these models is correct is the limited amount of data in the relevant temperature and pressure ranges. For water at ambient pressures, which is the focus of this work, data is largely missing from 160 – 232 K (“No Man’s Land”) due to rapid crystallization.2,3 Whether rapid crystallization is just an experimental obstacle, or a fundamental problem signaling the inability of water to thermally equilibrate prior to crystallization is also a major unanswered question.5,7 Here, we investigate the structural transformations of transiently-heated, supercooled water with nanosecond time resolution using infrared vibrational spectroscopy. The experiments demonstrate three key results. First, water’s structure relaxes from its initial configuration to a “steady-state” configuration prior to the onset of crystallization over a wide temperature range. Second, water’s steady-state structure can be reproduced by a linear combination of two, temperature-independent structures that correspond to a “high-temperature liquid” and a “low-temperature liquid.” Third, the observed structural changes are reversible over the full temperature range. Taken together, these results show that supercooled water can equilibrate prior to crystallization for temperatures from the homogeneous nucleation temperature, TH ~232 K,3 down to the glass transition temperature (Tg ~ 136 K). Second, the results provide support for the hypothesis that supercooled water can be described as a mixture of two, structurally-distinct, interconvertible liquids from 135 K to 245 K.5,8-18

Kringle, Loni M.↗

Lateral Water Structure Connects Metal Oxide Nanoparticle Faces

When a metal oxide surface is immersed in aqueous solution, it has the ability to bind, orient, and order interfacial water, affecting both chemical and physical interactions with the surface. Structured interfacial water thus possesses time-averaged, spatially varying polarization charge and potential that are comparable to those arising due to ion accumulation. It is well established that interfacial water structure propagates from the surface into bulk solution. Here, we show that interfacial water structure also propagates laterally, with important consequences. The constant pH molecular dynamics was used to impose a pH difference between opposite faces of a model goethite (a-FeOOH) nanoparticle and quantify water polarization charge on intervening faces. We find that the structure of water on one face is strongly affected by the structure on nearby surfaces, revealing the importance of long-range lateral hydrogen bonding networks with implications for particle aggregation, oriented attachment, and processes such as dissolution and growth.

Zarzycki, Piotr P.↗

Domestic wash-water reclamation using an aerospace-developed water recovery subsystem

A prototype aerospace distillation water recovery subsystem was tested to determine its capability to recover potable water from domestic wash water. A total of 0.0994 cu m (26.25 gallons) of domestic wash water was processed over a 7-day period at an average process rate of 0.0146 cu m per day (3.85 gallons per day). The subsystem produced water that met all United States Public Health Standards for drinking water with the exception of two standards which could not be analyzed at the required sensitivity levels. Average energy consumption for this evaluation to maintain both the recovery process and microbial control in the recovered water was approximately 3366 kilowatt-hours per cubic meter (12.74 kilowatt-hours per gallon) of water recovered. This condition represents a worst case energy consumption since no attempt was made to recover heat energy in the subsystem. An ultraviolet radiation cell installed in the effluent line of the subsystem was effective in controlling coliform micro-organisms within acceptable levels for drinking water. The subsystem recovered virtually 100 percent of the available water in the waste-water process. In addition, the subsystem removed 99.6 percent and 98.3 percent of the surfactants and phosphate, respectively, from the wash water.

Hall, J. B., Jr.↗

Production of long-term global water vapor and liquid water data set using ultra-fast methods to assimilate multi-satellite and radiosonde observations

During the next decade, many programs and experiments under the Global Energy and Water Cycle Experiment (GEWEX) will utilize present day and future data sets to improve our understanding of the role of moisture in climate, and its interaction with other variables such as clouds and radiation. An important element of GEWEX will be the GEWEX Water Vapor Project (GVaP), which will eventually initiate a routine, real-time assimilation of the highest quality, global water vapor data sets including information gained from future data collection systems, both ground and space based. The comprehensive global water vapor data set being produced by METSAT Inc. uses a combination of ground-based radiosonde data, and infrared and microwave satellite retrievals. This data is needed to provide the desired foundation from which future GEWEX-related research, such as GVaP, can build. The first year of this project was designed to use a combination of the best available atmospheric moisture data including: radiosonde (balloon/acft/rocket), HIRS/MSU (TOVS) retrievals, and SSM/I retrievals, to produce a one-year, global, high resolution data set of integrated column water vapor (precipitable water) with a horizontal resolution of 1 degree, and a temporal resolution of one day. The time period of this pilot product was to be det3ermined by the availability of all the input data sets. January 1988 through December 1988 were selected. In addition, a sample of vertically integrated liquid water content (LWC) was to be produced with the same temporal and spatial parameters. This sample was to be produced over ocean areas only. Three main steps are followed to produce a merged water vapor and liquid water product. Input data from Radiosondes, TOVS, and SSMI/I is quality checked in steps one and two. Processing is done in step two to generate individual total column water vapor and liquid water data sets. The third step, and final processing task, involves merging the individual output products to produce the integrated water vapor product. A final quality control is applied to the merged data sets.

Vonderhaar, T. H.↗

Understanding the Water Cycle Above the North Polar Cap on Mars Using MRO CRISM Retrievals of Water Vapor

The north polar cap (NPC) on Mars is the major reservoir of atmospheric water (H2O) currently on Mars. The retrieval and monitoring of atmospheric water vapor abundance are crucial for tracking the cycle of water above the NPC. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) aboard the Mars Reconnaissance Orbiter (MRO) has provided a wealth of data that extend over 5 + Martian years, covering the time period between 2006 and 2016. CRISM is ideally suited for spring and summer observations of the north polar region (latitudes poleward of 60 °N). The retrievals of water vapor column abundances over this extended period of time were performed over both ice-free and water ice covered surfaces, extending the coverage of the water vapor maps to include the permanent cap, where a maximum value of 90 precipitable micrometers (pr–µm) is retrieved, as compared to 60 pr–µm over ice-free regions in the North Polar Region. Away from summertime maximum, modest interannual variability in the water vapor abundance is observed. Zonal averages over all the observed Martian years combined show a developing water front that shifts northward towards summer, before dissipating over the permanent cap during mid-summer. A prominent feature at latitudes around 75 °N shows large abundances of water vapor, indicating a water vapor annulus encircling the retreating edge of the seasonal polar cap during late spring. Meridional transport of water modeled here show that the annulus may be a result of the convergence of water vapor from both south and north along the retreating edge of the NPC.

Khayat, Alain S. J.↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

A novel approach for produced water treatment: Supercritical water oxidation and desalination

Produced water generated from oil and gas operations contains significant quantities of environmentally hazardous hydrocarbons, organic chemicals, and inorganic salts. Environmental regulations with impaired water disposal mandates produced water treatment and desalination. Industry standard desalination technologies are energy-intensive and mandate extensive produced water pre-treatment including removal of hydrocarbons constituents for efficient operations. Herein this study investigates a novel process intensification approach integrating supercritical water oxidation (SCWO) unit operation with a supercritical water desalination (SCWD) process for energy efficient produced water treatment and desalination. The coupled SCWD-SCWO process is found to be very energy-efficient and cost effective than existing industry standard desalination technologies. For energy efficient operation, the heat generated from the SCWO of hydrocarbons present in the produced water is used for power generation using a high efficiency and low-cost re-heat Rankine cycle process. The cost of treating produced water with proposed SCWO-SCWD process is independent of the salt concentration. The proposed process has the potential to offer step-change improvements over conventional processes in both the efficiency and cost of produced water treatment: for example, a cost and energy saving of 70% and 100% is calculated for the treatment of produced water containing 250 g/l salt and 10.6 g/l hydrocarbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Urban Water Resilience: Coproducing Knowledge through Civic–Academic Global Partnerships on Water and Climate

As extreme weather events become more pronounced, the vulnerabilities associated with the urban water supply and wastewater systems in megacities are intensified in multiple interconnected dimensions. These multifaceted water challenges can benefit from enhanced cross-sectoral collaboration and sharing of critical knowledge, which are essential for sustainable and adaptive water governance frameworks. In this context, the Megacity Alliance for Water and Climate (MAWAC)–Europe and North America Region (ENAR) Working Group convened a workshop in March 2023, followed by a subsequent workshop in London, United Kingdom, from 11 to 13 September 2024. These workshops aimed to investigate and devise solutions for the cascading hazards with water systems. The solutions examined various aspects focused on climate adaptation and mitigation, stormwater management, and the governance of water and wastewater systems. Additionally, discussions highlighted the importance of community engagement, economic considerations, equity, and effective communication in addressing these pressing challenges. Over the course of 3 days, experts from academia, government agencies, and industry engaged in meaningful discussions on digital modeling for integrated water management, climate-informed urban planning, and public–private–academic partnerships (Fig. 1). Case studies from cities such as New York, Los Angeles, London, Paris, and Chicago highlighted innovative governance strategies for managing water and wastewater systems, promoting water reuse, planning infrastructure, and fostering stakeholder-driven and stakeholder-informed adaptation. The workshop participants emphasized the need for data-driven decision-making, scalable governance models, and knowledge-sharing networks to enhance urban water governance for sustainability and resilience. This workshop report presents the key takeaways from the 3-day convening, providing a roadmap for integrating scientific research, policy frameworks, and emerging technologies to address water challenges faced by megacities.

Hydrologic models↗

Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges.

15 GEOTHERMAL ENERGY↗

Produced Water and Waste Heat-aided Blowdown Water Treatment: Using Chemical and Energy Synergisms for Value Creation

The project objective was to develop a cooling blowdown water (BDW) treatment process utilizing produced water (PW) and low-grade heat to maximize water reuse and saleable by-product generation while reducing chemical and energy footprints of the treatment. The proposed treatment process consists of mixing, softening, organics and suspended solids removal, reverse osmosis (RO), thermal desalination, and brine electrolysis. BDW samples collected from a local coal-fired power plant and PW samples from two shale gas production wells were used in this study. Each treatment unit was first designed and tested to quantify its treatment efficiency, and its chemical and energy requirements. In addition, a process model was developed and model simulations were conducted based on the experimental results and literature data to optimize the treatment process. A techno-economic analysis was conducted to quantify chemical and energy savings as well as production of 10-lb brine as a saleable product. With the field-collected BDW and PW samples, mixing experiments determined a volumetric mixing ratio 10:1 (BDW:PW) resulted in the best performance of multivalent ions removal and largest chemical savings for softening. Softening of the BDW/PW mixtures using alkaline chemicals (Na 2 CO 3 and NaOH) achieved 95%-100% removal of scaling-forming cations (Ca, Mg, Fe, Ba, Sr) and 60% of silicon, and 10% of total organic carbon (TOC). The mixing and softening treatments yielded an effluent with total dissolved solids (TDS) concentration of 23 g/L. Activated carbon (AC) filtration removed TOC to a low level (< 3 mg/L) and further removed remaining scale-forming divalent metals and silica from the softened water. The AC filtration resulted in a slight reduction of TDS from 23 g/L to 20 g/L, leaving behind only mostly monovalent ions (i.e., sodium and chloride) in the filtered water. These pretreatments yielded a feed water that met the criteria of the downstream reverse osmosis (RO) to prevent membrane fouling. A cross-flow RO system was used to further concentrate the TDS of the AC effluent. Various factors including TDS, pH, and applied pressure were examined and optimal conditions were determined for the co-treatment process. An integrated process consisting of mixing, softening, AC filtration and RO was used to treat a continuous flow (0.25 – 1.2 L/min, or 0.07 – 0.32 gpm) and successfully generated RO permeate as product water (TDS < 0.5 g/L) for reuse in cooling operation, and a concentrate (TDS ~ 45 g/L) to be further treated in a thermal desalination unit. These flow rates meet the FOA’s criterion of 0.01 – 1 gpm. Overall, the co-treatment of BDW/PW allowed shorter ramp-up time compared to treatment of BDW alone. It resulted in 40% and 55% savings of Na 2 CO 3(s) and NaOH, respectively, compared to treating the BDW and PW individually for the same level of softening. The co-treatment also resulted in a 29% energy saving compared to treatment of BDW only for the level of TDS concentration. A thermal desalination system was designed using CFD simulations and manufactured in the WVU Innovation Hub for further treatment of the RO concentrate to generate 10-lb brine. The system has a design flow rate of 2 gpm and has been successfully tested. A bench-scale brine electrolysis system was developed for on-site generation of chlorine/hypochlorite (Cl 2 /OCl - ) and caustic soda (NaOH) as useful chemicals for the co-treatment process. Using salt solutions (0.5 M and 1 M), the system achieved faradaic efficiencies of 93%-97% and 70%-77% for caustic soda and chlorine/hypochlorite generation, respectively. An economic analysis showed that the electricity costs for on-site generation of these chemicals were significantly lower than the chemical prices offered by suppliers. An industrial-scale process model consisting of mixing, softening, AC filtration, RO, thermal desalination, and brine electrolysis was developed using the Aspen Plus V9 in conjunction with Aspen Custom Modeler V9. The model serves as a solvable Aspen Plus model and as basis to form the costing infrastructure. In addition, techno-economic analysis considering capital, operating, and transportation costs was conducted. An optimization solution showed that produced water for mixing is still advantageous in low quantities. The optimum solution approaches a leveled cost of water (LCW) of 2 $/m 3 which becomes cost competitive with nominal water treatment prices.

20 FOSSIL-FUELED POWER PLANTS↗

In situ monitoring of H and O stable isotopes in soil water reveals ecohydrologic dynamics in managed soil systems [Urban ecohydrologic dynamics revealed by in situ monitoring of H and O stable isotopes in soil water]

The water cycle in urban and hydrologically managed settings is subject to perturbations that are dynamic on small spatial and temporal scales; the effects of which may be especially profound in soils. We deploy a membrane inlet-based laser spectroscopy system in conjunction with soil moisture and temperature sensors to monitor soil water dynamics and H and O stable isotope ratios (δ 2 H and δ 18 O values) in a seasonally irrigated urban-landscaped garden soil over the course of 9 months between the cessation of irrigation in the autumn and the onset of irrigation through the summer. Here, we find that soil water δ 2 H and δ 18 O values predominately reflect seasonal precipitation and irrigation inputs. A comparison of total soil water by cryogenic extraction and mobile soil water measured by in situ water vapor probes reveals that initial infiltration events after long periods of soil drying (the autumn season in this case) emplace water into the soil matrix that is not easily replaced by, or mixed with, successive pulses of infiltrating soil water. Tree stem xylem water H and O stable isotope composition did not match that of available water sources. Our findings suggest that partitioning of soil water into mobile and immobile “pools” and resulting ecohydrologic separation may occur in engineered and hydrologically managed soils and not be limited to natural settings. Furthermore, the laser spectroscopy method detailed here has potential to yield insights in a variety of critical zone and vadose zone studies, potential that is heightened by the simplicity and portability of the system.

07 ISOTOPE AND RADIATION SOURCES↗