Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WASHINGTON DC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Requirements Definition for ORNL Trusted Corridors Project

The ORNL Trusted Corridors Project has several other names: SensorNet Transportation Pilot; Identification and Monitoring of Radiation (in commerce) Shipments (IMR(ic)S); and Southeastern Transportation Corridor Pilot (SETCP). The project involves acquisition and analysis of transportation data at two mobile and three fixed inspection stations in five states (Kentucky, Mississippi, South Carolina, Tennessee, and Washington DC). Collaborators include the State Police organizations that are responsible for highway safety, law enforcement, and incident response. The three states with fixed weigh-station deployments (KY, SC, TN) are interested in coordination of this effort for highway safety, law enforcement, and sorting/targeting/interdiction of potentially non-compliant vehicles/persons/cargo. The Domestic Nuclear Detection Office (DNDO) in the U.S. Department of Homeland Security (DHS) is interested in these deployments, as a Pilot test (SETCP) to identify Improvised Nuclear Devices (INDs) in highway transport. However, the level of DNDO integration among these state deployments is presently uncertain. Moreover, DHS issues are considered secondary by the states, which perceive this work as an opportunity to leverage these (new) dual-use technologies for state needs. In addition, present experience shows that radiation detectors alone cannot detect DHS-identified IND threats. Continued SETCP success depends on the level of integration of current state/local police operations with the new DHS task of detecting IND threats, in addition to emergency preparedness and homeland security. This document describes the enabling components for continued SETCP development and success, including: sensors and their use at existing deployments (Section 1); personnel training (Section 2); concept of operations (Section 3); knowledge discovery from the copious data (Section 4); smart data collection, integration and database development, advanced algorithms for multiple sensors, and network communications (Section 5); and harmonization of local, state, and Federal procedures and protocols (Section 6).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creating New Incentives for Risk Identification and Insurance Process for the Electric Utility Industry (initial award through Award Modification 2); Energy & Risk Transfer Assessment (Award Modifications 3 - 6)

This is the final report for the DOE-NETL grant entitled 'Creating New Incentives for Risk Identification & Insurance Processes for the Electric Utility Industry' and later, 'Energy & Risk Transfer Assessment'. It reflects work done on projects from 15 August 2004 to 29 February 2008. Projects were on a variety of topics, including commercial insurance for electrical utilities, the Electrical Reliability Organization, cost recovery by Gulf State electrical utilities after major hurricanes, and review of state energy emergency plans. This Final Technical Report documents and summarizes all work performed during the award period, which in this case is from 15 August 2004 (date of notification of original award) through 29 February 2008. This report presents this information in a comprehensive, integrated fashion that clearly shows a logical and synergistic research trajectory, and is augmented with findings and conclusions drawn from the research as a whole. Four major research projects were undertaken and completed during the 42 month period of activities conducted and funded by the award; these are: (1) Creating New Incentives for Risk Identification and Insurance Process for the Electric Utility Industry (also referred to as the 'commercial insurance' research). Three major deliverables were produced: a pre-conference white paper, a two-day facilitated stakeholders workshop conducted at George Mason University, and a post-workshop report with findings and recommendations. All deliverables from this work are published on the CIP website at http://cipp.gmu.edu/projects/DoE-NETL-2005.php. (2) The New Electric Reliability Organization (ERO): an examination of critical issues associated with governance, standards development and implementation, and jurisdiction (also referred to as the 'ERO study'). Four major deliverables were produced: a series of preliminary memoranda for the staff of the Office of Electricity Delivery and Energy Reliability ('OE'), an ERO interview protocol and stakeholder/experts interviews, a formal research paper, and a data quality and availability study of North American Electric Reliability Corporation/ERO's disturbances and outages working group ('DAWG') databases. (3) Critical Electric Power Infrastructure Recovery and Reconstruction: Issues & New Policy Initiatives in Four Gulf Coast States After 2005's Catastrophic Hurricanes (also referred to as the 'Gulf Coast cost recovery study'). Four deliverables were produced: the original research paper providing preliminary findings and recommendations (29 September 2006), a formal presentation of that report to officials, staff and invited guests at OE's Washington, DC headquarters, a series of update memoranda and quarterly activity updates (1 November 2006 through Q3-2007), and a final cumulative update of the original research report (February 2008). Documentation and information on these research activities can be found on the CIP website at http://cipp.gmu.edu/projects/DoE-NETL-2006.php. (4) Evaluation of State Energy Emergency Response Plans (also referred to as the 'SEERP project'). Two major deliverables were produced: an evaluation of 47 SEERPs with findings, statistical analyses, geospatial renderings (mappings of the States whose plans were evaluated with statistical analysis underpinnings) and recommendations (17 September 2007), and a major revision to the original deliverable to include one additional plan (Missouri), with fully updated findings, statistical analyses, geospatial renderings, and recommendations (Revision 1, 29 February 2008).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic impacts of a hypothetical H1N1 pandemic : a cross-sectional analysis.

A NISAC study on the economic effects of a hypothetical H1N1 pandemic was done in order to assess the differential impacts at the state and industry levels given changes in absenteeism, mortality, and consumer spending rates. Part of the analysis was to determine if there were any direct relationships between pandemic impacts and gross domestic product (GDP) losses. Multiple regression analysis was used because it shows very clearly which predictors are significant in their impact on GDP. GDP impact data taken from the REMI PI+ (Regional Economic Models, Inc., Policy Insight +) model was used to serve as the response variable. NISAC economists selected the average absenteeism rate, mortality rate, and consumer spending categories as the predictor variables. Two outliers were found in the data: Nevada and Washington, DC. The analysis was done twice, with the outliers removed for the second analysis. The second set of regressions yielded a cleaner model, but for the purposes of this study, the analysts deemed it not as useful because particular interest was placed on determining the differential impacts to states. Hospitals and accommodation were found to be the most important predictors of percentage change in GDP among the consumer spending variables.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding the Charging Flexibility of Shared Automated Electric Vehicle Fleets

The combined anticipated trends of vehicle sharing (ride-hailing), automated control, and powertrain electrification are poised to disrupt the current paradigm of predominately owner-driven gasoline vehicles with low levels of utilization. Shared, automated, electric vehicle (SAEV) fleets offer the potential for lower cost and emissions and have garnered significant interest among the research community. While promising, unmanaged operation of these fleets may lead to unintended negative consequences. One potentially unintended consequence is a high quantity of SAEVs charging during peak demand hours on the electric grid, potentially increasing the required generation capacity. This research explores the flexibility associated with charging loads demanded by SAEV fleets in response to servicing personal mobility travel demands. Travel demand is synthesized in four major United States metropolitan areas: Detroit, MI; Austin, TX; Washington, DC; and Miami, FL. In each of these four cities, SAEV simulations are performed using local projected electricity prices from the Regional Energy Deployment System (ReEDS) for a handful of supply side scenarios. A coordinated charging model is introduced that seeks to reduce fleet charging costs in response to time-varying electricity prices and increasing shares of personal trip demand served (between 1% and 25% of all metro trips served by the SAEV fleet). Simulation results are presented across various scenarios assuming fleetwide coordination to minimize charging energy costs while constrained by offering adequate mobility service to fleet customers. The results indicate that the SAEV charging load is highly flexible; energy costs were shown to reduce between 13% and 46% across a wide range of simulated scenarios. In addition, these savings were realized without detrimentally impacting the fleet’s ability to service trips.

autonomous vehicle↗

Underestimation of column NO 2 amounts from the OMI satellite compared to diurnally varying ground-based retrievals from multiple PANDORA spectrometer instruments

Retrievals of total column NO 2 (TCNO 2 ) are compared for 14 sites from the Ozone Measuring Instrument (OMI using OMNO2-NASA v3.1) on the AURA satellite and from multiple ground-based PANDORA spectrometer instruments making direct-sun measurements. While OMI accurately provides the daily global distribution of retrieved TCNO 2 , OMI almost always underestimates the local amount of TCNO 2 by 50 % to 100 % in polluted areas, while occasionally the daily OMI value exceeds that measured by PANDORA at very clean sites. Compared to local ground-based or aircraft measurements, OMI cannot resolve spatially variable TCNO 2 pollution within a city or urban areas, which makes it less suitable for air quality assessments related to human health. In addition to systematic underestimates in polluted areas, OMI's selected 13:30 Equator crossing timepolar orbit causes it to miss the frequently much higher values of TCNO 2 that occur before or after the OMI overpass time. Six discussed Northern Hemisphere PANDORA sites have multi-year data records (Busan,Seoul, Washington DC, Waterflow, New Mexico, Boulder, Colorado, and Mauna Loa),and one site in the Southern Hemisphere (Buenos Aires, Argentina). The first four of these sites and Buenos Aires frequently have high TCNO 2 (TCNO 2 > 0.5 DU). Eight additional sites have shorter-term data records in the US and South Korea. One of these is a 1-year data record from a highly polluted site at City College in New York City with pollution levels comparable to Seoul, South Korea. OMI-estimated air mass factor, surface reflectivity, and the OMI 24 km × 13 km FOV (field of view)are three factors that can cause OMI to underestimate TCNO 2 . Because of the local inhomogeneity of NO x emissions, the large OMI FOV is the most likely factor for consistent underestimates when comparing OMI TCNO 2 to retrievals from the small PANDORA effective FOV (measured in m 2 ) calculated from the solar diameter of 0.5°.

47 OTHER INSTRUMENTATION↗

LANDSAT-4 thematic mapper Modulation Transfer Function (MTF) evaluation

A power spectrum (PS) analysis technique was used to compare thematic mapper (TM) A and P-tape data for a Washington, DC scene in two orthogonal directions, along scan and along track. The resulting effective modulation transfer functions (MTF) between the A and P data are repeatable from area to area and consistent with theoretical expectations. The average x-direction (along scan) MTF calculated with the PS technique is compared to the MTF of the cubic convolution resampling function used to create P data from A data. The two curves are nearly identical, indicating that the major factor affecting the image quality of P data relative to A data is the cubic convolution resampling.

Schowengerdt, R.↗

Stratospheric water vapor variability for Washington, DC/Boulder, CO - 1964-82

Measurements for Washington, DC and Boulder, CO are combined to provide a time series of midlatitude stratospheric water vapor data for the period 1964-82. The mean concentration for the data period is shown to be nearly constant with altitude for the low stratospheric layer between 16-22 km with a mass mixing ratio for the layer of 2.5-2.6 ppmm. Above 22 km the mixing ratio increases slightly with altitude. Evident in the 60 mb level time series is an annual cycle, a quasi-biennial cycle and a long-term nonlinear trend. The quasi-biennial cycle in water vapor at midlatitudes is consistent with variations in tropical stratosphere zonal winds and temperature and total ozone and suggests a modulation of the Hadley cell circulation. The long-term trend shows mixing ratio increasing during the 1960s and decreasing in the 1970s after 1972.

Mastenbrook, H. J.↗

Light extinction by aerosols during summer air pollution

In order to utilize satellite measurements of optical thickness over land for estimating aerosol properties during air pollution episodes, the optical thickness was measured from the surface and investigated. Aerosol optical thicknesses have been derived from solar transmission measurements in eight spectral bands within the band lambda 440-870 nm during the summers of 1980 and 1981 near Washington, DC. The optical thicknesses for the eight bands are strongly correlated. It was found that first eigenvalue of the covariance matrix of all observations accounts for 99 percent of the trace of the matrix. Since the measured aerosol optical thickness was closely proportional to the wavelength raised to a power, the aerosol size distribution derived from it is proportional to the diameter (d) raised to a power for the range of diameters between 0.1 to 1.0 micron. This power is insensitive to the total optical thickness. Changes in the aerosol optical thickness depend on several aerosol parameters, but it is difficult to identify the dominant one. The effects of relative humidity and accumulation mode concentration on the optical thickness are analyzed theoretically, and compared with the measurements.

Kaufman, Y. J.↗

Comparative accuracies of AVHRR and MSS data used for Level I land cover classifications

The capabilities of the Advanced Very High Resolution Radiometer (AVHRR) for land cover mapping were investigated by comparing the accuracy of land cover information for the Washington, DC area derived from NOAA-7 AVHRR data with that from Landsat Multispectral Scanner (MSS) data. Unsupervised Level I land cover classifications were performed for MSS and AVHRR data sets collected on July 11, 1981. A detailed accuracy assessment was conducted based on ground truth delineated on six USGS 7.5 minute series topographic maps. Preliminary results produced overall land cover classification accuracies of 75.6 percent and 76.1 percent for AVHRR and MSS, respectively. While the accuracies for predominant categories such as agriculture, forest, and urban were similar for both sensors, discrimination of the less commonly occurring categories such as barren, wetland, and water was improved with the MSS data set. The AVHRR, however, performed as well as or better than the MSS in classifying large homogeneous areas. The application of AVHRR data with its lower processing cost and more frequent worldwide coverage appears promising for global land cover mapping.

Gervin, J. C.↗

An analysis of Landsat-4 Thematic Mapper geometric properties

Landsat-4 Thematic Mapper data of Washington, DC, Harrisburg, PA, and Salton Sea, CA were analyzed to determine geometric integrity and conformity of the data to known earth surface geometry. Several tests were performed. Intraband correlation and interband registration were investigated. No problems were observed in the intraband analysis, and aside from indications of slight misregistration between bands of the primary versus bands of the secondary focal planes, interband registration was well within the specified tolerances. A substantial number of ground control points were found and used to check the images' conformity to the Space Oblique Mercator (SOM) projection of their respective areas. The means of the residual offsets, which included nonprocessing related measurement errors, were close to the one pixel level in the two scenes examined. The Harrisburg scene residual mean was 28.38 m (0.95 pixels) with a standard deviation of 19.82 m (0.66 pixels), while the mean and standard deviation for the Salton Sea scene were 40.46 (1.35 pixels) and 30.57 m (1.02 pixels), respectively. Overall, the data were judged to be a high geometric quality with errors close to those targeted by the TM sensor design specifications.

Walker, R. E.↗

A statistical evaluation of the advantages of Landsat Thematic Mapper data in comparison to Multispectral Scanner data

On July 16, 1982, the second decade of land remote sensing from space was inaugurated with the successful launch of Landsat-4. This satellite carries the Multispectral Scanner (MSS) and a new sensor, the Thematic Mapper (TM). The TM represents the result of an effort in which all of the major improvements in remote-sensing capability were simultaneously integrated into one system. An experiment was developed and conducted to quantify the effect of each TM sensor parameter on classification accuracy. This paper discusses the experimental design and summarizes the results obtained using TM data acquired over the Washington, DC area on November 2, 1982. Attention is given to a study site/data description, the experimental design, photointerpretation and digitization, spectral simulation, radiometric simulation, and spatial simulation.

Williams, D. L.↗

Intraband Radiometric Performance of the LANDSAT 4 Thematic Mapper

Those radiometric characteristics of the LANDSAT 4 thematic mapper (TM) that could be established without absolute calibration of spectral data were examined. Radiometrically raw (B type) data of three daytime and two nighttime scenes were used, including TM scenes from Washington, DC; northeast Arkansas; Cape Cod, MA; Roanoke, VA; Richmond, VA; and Silver Bell, AZ. The effective resolution in radiance is degraded by a factor of about 2 by the irregular width of the digital levels. Underpopulated levels are consistent over all bands and detectors, and are spaced an average of 4 digital numbers (DN) apart. In band 6, level 127 is avoided by a factor 30. Several detectors exhibit a change of gain with a period of several scans; the largest effect is about 4%. At high contrast boundaries, some of the detectors in band 5 commonly overshoot by several DN and require about 30 samples to recover. The high frequency noise level of each detector was characterized by the standard deviation of the first derivative in the sample direction across a flat field. A coherent-sinusoidal-noise pattern is evident in detector 1 of band 3. The correlation between the six reflective bands was determined and used to select three groups of bands whose aggregate first principal components contain the greatest total information. A composite of the first components of bands 1, 2, 3, bands 5 and 7, and band 4, together containing 89% of the information in the reflectance bands, has reduced the effect of noise.

Kieffer, H. H.↗

Relative Accuracy Assessment of LANDSAT-4 MSS and TM Data for Level 1 Land Cover Inventory

Digital data for the Washington, DC scene simultaneously acquired by the LANDSAT-4 Multispectral Scanner (MSS) and the LANDSAT-4 thematic mapper (TM) was compared. Classification success for the TM and MSS data sets was determined by a per pixel comparison with digitized ground verification data (GVD). These GVD were comprised of Level 7 land cover (developed, agriculture, forest, water, wetlands, and barren) for four USGS 7.5 minute topographic quadrangle maps. The relative improvement in classification success for TM was between 11% and 14%, or about a factor of 1.3, for these data. This represents a meaningful improvement in accuracy for Level 7 land cover categorization for TM relative to MSS, particularly when errors of omission and commission were considered.

Middleton, E. M.↗

Impact of thematic mapper sensor characteristics on classification accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, DC, each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30 m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

Comparison of level I land cover classification accuracy for MSS and AVHRR data

The capabilities of the Advanced Very-High-Resolution Radiometer (AVHRR) for land-cover mapping were investigated by comparing the accuracy of land-cover information for the Washington, DC area derived from NOAA-7 AVHRR data with that from Landsat Multispectral Scanner Subsystem (MSS) data. Unsupervised level I land-cover classifications were performed for MSS and AVHRR data sets collected on July 11, 1981. A detailed accuracy assessment was conducted based on ground data delineated on 12 U.S. Geological Survey 7-5 min series topographic maps. These results produced overall land-cover classification accuracies of 71.9 and 76.8 per cent for AVHRR and MSS, respectively. While the accuracies for predominant categories were similar for both sensors, land-cover discrimination for less commonly occurring and/or spatially heterogeneous categories was improved with the MSS data set. The AVHRR, however, performed as well as or better than the MSS in classifying large homogeneous areas. The application of AVHRR data with its lower processing cost and more frequent worldwide coverage appears promising for regional land-cover mapping.

Gervin, J. C.↗

A new format proposal

The American Congress on Surveying and Mapping (ACSM) National Committee on Digital Cartographic Data Standards has been chartered by the National Bureau of Standards to recommend a format for the interchange of digital cartographic data. The committee presented the format concept at the spring 1985 ACSM meeting in Washington, DC. It is the intent that this concept be reviewed by the concerned public, who are asked to provide reactions to the committee.

Billingsley, F. C.↗

The geometric properties of Landsat-5 Thematic Mapper data and their conformity to Landsat-4 data and to earth's surface geometry

The geometry of two TIPS processed Landsat-5 Thematic Mapper scenes was analyzed and compared with that of SCROUNGE processed Landsat-4 data. Swath-to-swath and band-to-band registration of Washington, DC, and northeastern Iowa scenes was found to be similar to or better than that of Landsat-4 data. Results indicate a high degree of geometric conformity between the images produced by the different systems. The geometric conformity of the TIPS processed images to the Space Oblique Mercator projection, however, proved to be less accurate than the targeted processing error of 15 meters.

Walker, R. E.↗