Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WASHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Study on Electrostatic Separation of Quinoline Insolubles from Coal Tar Pitch

The feasibility of electrical separation in the removal of quinoline insoluble (QI) particles from coal tar pitch (CTP) was experimentally investigated. QI particle involvement prohibits the effective fabrication of high-quality value-added products, such as carbon fibers, from CTP. A substantial and sustainable CTP market exists around the world; therefore, a strong incentive exists to develop a viable technical approach to effectively and economically remove QI particles from CTP. The electrical separation method shows promise to achieve this technical goal (Cao et al., 2012). Even with the given setup (wire- cylinder adapted), critical issues remain to be addressed for this method to be applicable to the CTP: (1) identifying the wash oil used in the original QI separation, (2) understanding the mechanism of QI separation, (3) characterizing the deposit, and (4) identifying the QI. This study integrated a set of experimental and analysis techniques into the electrical separation tests to address the aforementioned issues. Key findings are as follows: 1. Electric current responses: • The electric current level of the CTP–wash oil solution reported by Cao et al. (2012) can be attained by using a mixture of 25% quinoline and 75% toluene for the CTPs examined in this study under the same electrical load condition. • The electric current tends to decrease during the test period because of the decreasing number of charged particles. • The reversed field corresponded to the configuration of electrostatic precipitation for positive corona discharge. The high electric field can result in dielectric breakdown and lead to an abrupt current surge. 2 Deposit response and solvent candidates: • Deposit of particles in CTP mixture can be effectively implemented in a wire-cylinder configuration as proposed and examined in this study. • Deposit depends on the solvents. Among the solvents tested, two- and three-part solvents that included quinoline and ethanol (i.e., 25% quinoline and 75% toluene; 50% quinoline and 50% toluene; and 33% wash oil, 33% BTX, and 34% ethanol) produced the highest deposit weight. • The deposit process examined in this study is derived from the charged particles. An appreciable relation exists between deposit weight and electric charge. 3. QI removal efficiency (RE): • The RE of the electrostatic separation can reach as high as 76.2% for Carbores, and 61.6% for Koppers. • The RE can be further enhanced if the field level increases from 0.16 kV/mm that was used in the current study to 0.23 kV/mm, according to the relation established between the RE and the electric field. 4. Testing of the modeling system: • The motion of particles is originally driven by the charge-based electric force in the cases tested. The solid particle separation mechanism is similar to that of QI deposition in CTP. • The mechanical movement of solid particles can be strongly affected by the gravitational and viscous forces in the electric field. 5. EDS analysis and chemical compositions: • The main chemical composition of deposit QI matches that of as-prepared CTP QI. The deposit QI is derived from the same group of the CTP QI. • In addition to carbon, the QI contains oxygen, sodium, aluminum, silicon, iron, and sulfur. The work for the near future is also discussed.

01 COAL, LIGNITE, AND PEAT↗

Phosphate and Fluoride Processing Options for Hanford Sludge

The Direct Feed High-Level Waste (DFHLW) strategy represents an alternative flowsheet to bypass the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration and should be considered in the new DFHLW flowsheet to maximize waste feed loading, minimize high-level waste (HLW) volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. The effectiveness and efficiency of sludge washing can have a substantial impact on DST space and mission duration. Two target species that benefit significantly from washing are phosphate and fluoride. Commonly present in many high-level wastes at Hanford, phosphate and fluoride are found predominately in the form of salt precipitates and can have adverse and detrimental effects on glass waste loading. Additionally, fluoride produces melter off-gas that creates corrosion risks in the off-gas system piping. Determining the solubilities of fluoride and phosphate salts, as well as the dissolution kinetics under potential HLW processing conditions will help to mitigate future operational risks and mature flowsheet technical bases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 26

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 26 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 26 prior to transfer from Tank 26 to Tank 51 that confirms the transfer is "Low Rem" and ensures the sludge concurs with the estimated transfer mass for the SB11 recipe. Two Tank 26 samples were delivered to SRNL and composited into a single sample in September 2023. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, supernate corrosion control tests, and x-ray diffraction for burkeite, gibbsite, and boehmite. The slurry was also evaluated for sulfate washing behavior in order to provide knowledge on insoluble sulfate dissolution during Tank 51 sludge washing similar to a previous washing study performed in 2019. The Tank 26 sample results are consistent with and representative of PUREX sludge and the prior usage of Tank 26 as a feed tank for the 1F and 2F Evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 26 (Rev.1)

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 26 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 26 prior to transfer from Tank 26 to Tank 51 that confirms the transfer is "Low Rem" and ensures the sludge concurs with the estimated transfer mass for the SB11 recipe. Two Tank 26 samples were delivered to SRNL and composited into a single sample in September 2023. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, supernate corrosion control tests, and x-ray diffraction for burkeite, gibbsite, and boehmite. The slurry was also evaluated for sulfate washing behavior in order to provide knowledge on insoluble sulfate dissolution during Tank 51 sludge washing similar to a previous washing study performed in 2019. The Tank 26 sample results are consistent with and representative of PUREX sludge and the prior usage of Tank 26 as a feed tank for the 1F and 2F Evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fractionation of Filamentous Algae from Mixed Biofilms

Filamentous algae, which grow in long, hair-like filaments within biofilms, play a crucial role in wastewater treatment due to their ability to produce significant biomass and their resistance to predation compared to traditional microalgal treatments. These algae can effectively uptake and utilize pollutants, particularly excessive nitrogen (ammonia, nitrate, nitrite) and phosphorus (phosphate), making filamentous algae valuable for wastewater treatment, as well as bioethanol and biodiesel production due to high lipid productions. However, each algal species possesses different capacities, necessitating a thorough genetic identification and understanding of each community. A major challenge in accurately assessing these communities is the lack of coverage in large sequencing databases which can lead to misrepresentation of the true composition and abundance of organisms and overall sequencing bias. To address this, I evaluated chemical and physical techniques for separating filamentous algae from mixed biofilms to achieve clean genetic sequencing results. I employed pH washing (0.001M HCl, 0.001M HCl, DiH2O, 0.0001M HCl, 0.001M HCl) for chemical treatment, followed by physical separation through centrifugation (5000rpm, 6500rpm) or filtration (2mm, 250um, 75um). The most successful method was deionized water washing, which yielded clear differences across stacked filters; the 2mm filtrate showed high levels of filamentous algae, with microalgae eluting in the 75um filtrate or remaining within agglutinations of algae larger filters. Base washing eluted the highest concentrations of microalgae, with larger filter sizes retaining more filamentous algae, indicating the breakdown of extracellular polymeric substances (EPS). Our downstream plans include sending the high-throughput next-generation sequencing to confirm the purity and ratios of filamentous and non-filamentous algae, as well as bacteria present, thereby validating the success of our treatments. Potential applications include creating community-based fractions for analysis, refining current sequencing data with clearer isolations, and generating designer biofilms to enhance our understanding of community interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HLW Processing for Complementary Disposition Strategy: Development and Testing of Glass and Feed Formulations

The objective of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends for vitrification of selected HLW streams, which have undergone various degrees of washing but no other pretreatment, while maintaining high WLs, high processing rates, and acceptable glass properties. The glass formulations were actively designed and based on previous formulation experience and testing at VSL. The WTP baseline HLW property-composition models were used to select glass formulations for testing and to predict various glass properties. Crucible-scale fabrication of the HLW glasses that were formulated was performed and the product glasses were characterized with respect to select properties. A total of 10 HLW glasses were developed and tested for five fully washed waste batches and one singly washed waste batch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LITERATURE REVIEWS TO SUPPORT ION EXCHANGE TECHNOLOGY SELECTION FOR MODULAR SALT PROCESSING

This report summarizes the results of literature reviews conducted to support the selection of a cesium removal technology for application in a small column ion exchange (SCIX) unit supported within a high level waste tank. SCIX is being considered as a technology for the treatment of radioactive salt solutions in order to accelerate closure of waste tanks at the Savannah River Site (SRS) as part of the Modular Salt Processing (MSP) technology development program. Two ion exchange materials, spherical Resorcinol-Formaldehyde (RF) and engineered Crystalline Silicotitanate (CST), are being considered for use within the SCIX unit. Both ion exchange materials have been studied extensively and are known to have high affinities for cesium ions in caustic tank waste supernates. RF is an elutable organic resin and CST is a non-elutable inorganic material. Waste treatment processes developed for the two technologies will differ with regard to solutions processed, secondary waste streams generated, optimum column size, and waste throughput. Pertinent references, anticipated processing sequences for utilization in waste treatment, gaps in the available data, and technical comparisons will be provided for the two ion exchange materials to assist in technology selection for SCIX. The engineered, granular form of CST (UOP IE-911) was the baseline ion exchange material used for the initial development and design of the SRS SCIX process (McCabe, 2005). To date, in-tank SCIX has not been implemented for treatment of radioactive waste solutions at SRS. Since initial development and consideration of SCIX for SRS waste treatment an alternative technology has been developed as part of the River Protection Project Waste Treatment Plant (RPP-WTP) Research and Technology program (Thorson, 2006). Spherical RF resin is the baseline media for cesium removal in the RPP-WTP, which was designed for the treatment of radioactive waste supernates and is currently under construction in Hanford, WA. Application of RF for cesium removal in the Hanford WTP does not involve in-riser columns but does utilize the resin in large scale column configurations in a waste treatment facility. The basic conceptual design for SCIX involves the dissolution of saltcake in SRS Tanks 1-3 to give approximately 6 M sodium solutions and the treatment of these solutions for cesium removal using one or two columns supported within a high level waste tank. Prior to ion exchange treatment, the solutions will be filtered for removal of entrained solids. In addition to Tanks 1-3, solutions in two other tanks (37 and 41) will require treatment for cesium removal in the SCIX unit. The previous SCIX design (McCabe, 2005) utilized CST for cesium removal with downflow supernate processing and included a CST grinder following cesium loading. Grinding of CST was necessary to make the cesium-loaded material suitable for vitrification in the SRS Defense Waste Processing Facility (DWPF). Because RF resin is elutable (and reusable) and processing requires conversion between sodium and hydrogen forms using caustic and acidic solutions more liquid processing steps are involved. The WTP baseline process involves a series of caustic and acidic solutions (downflow processing) with water washes between pH transitions across neutral. In addition, due to resin swelling during conversion from hydrogen to sodium form an upflow caustic regeneration step is required. Presumably, one of these basic processes (or some variation) will be utilized for MSP for the appropriate ion exchange technology selected. CST processing involves two primary waste products: loaded CST and decontaminated salt solution (DSS). RF processing involves three primary waste products: spent RF resin, DSS, and acidic cesium eluate, although the resin is reusable and typically does not require replacement until completion of multiple treatment cycles. CST processing requires grinding of the ion exchange media, handling of solids with high cesium loading, and handling of liquid wash and conditioning solutions. RF processing requires handling and evaporation of cesium eluates, disposal of spent organic resin, and handling of the various liquid wash and regenerate solutions used. In both cases, the DSS will be immobilized in a low activity waste form. It appears that both technologies are mature, well studied, and generally suitable for this application. Technology selection will likely be based on downstream impacts or preferences between the various processing options for the two materials rather than on some unacceptable performance property identified for one material. As a result, the following detailed technical review and summary of the two technologies should be useful to assist in technology selection for SCIX.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TEA of a Unique Two-Pathways Process for Post-Combustion CO 2 Capture

A unique two-Pathways process using aqueous sodium glycinate for CO 2 capture from a split flue gas stream emitted from 600 MWe post-combustion coal power plant was developed in Aspen Plus v.10. The split gas flow rate used was 44.75 ton/h and contained 0.0023 mol% SO 2 and 13.33 mol% CO 2 . The process includes a washing unit, a CO 2 absorption unit, a reverse osmosis unit, and a solvent regeneration unit or an ultrafiltration unit. The washing unit uses deionized water to completely remove SO 2 and the CO 2 absorption unit uses SGS to capture at least 90 mol% of the CO 2 in the split flue gas stream. Upon CO 2 and SGS reactions, the resulting liquid products exhibit phase-separation into CO 2 -lean phase and CO 2 -rich phase, allow two distinct pathways. Pathway (i) is to regenerate mostly the CO 2 -rich phase, collect the released CO 2 , and compress it for sequestration purposes. Pathway (ii) is to send the liquid stream from the CO 2 absorption unit to the ultrafiltration unit to separate the solid nanomaterials. The hydraulics and mass transfer characteristics in the washing and CO 2 absorption units were obtained; and techno-economic analysis (TEA) for Pathways (i) and (ii), including Capital Expenditure (CAPEX), Operating Expenditure (OPEX), and Levelized Cost of CO 2 Captured (LCOC), were calculated and compared. The simulation results revealed that the CAPEX, OPEX, and LCOC for Pathway (i) were ($\$12,039,251$), (261 dollar/h), and (54.01 dollar/ton-CO 2 captured), respectively, and those for Pathway (ii) were ($\$5,908,000$), (237.2 dollar/h), and (39.90 dollar/ton-CO 2 captured), respectively. Moreover, in Pathway (ii), 8.19 ton/h of CO 2 were captured to produce 15.62 ton/h NaHCO 3 nanomaterials, which were sold to offset the overall process cost. The LCOC values indicate that Pathway (ii) is more cost-effective than Pathway (i) because LCOC values for Pathway (ii) are much lower than those for Pathway (i).COC values for Pathway (ii) are much lower than those for Pathway (i).

20 FOSSIL-FUELED POWER PLANTS↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Methods for multi-material stereolithography

Methods and systems of stereolithography for building cost-efficient and time-saving multi-material, multi-functional and multi-colored prototypes, models and devices configured for intermediate washing and curing/drying is disclosed including: laser(s), liquid and/or platform level sensing system(s), controllable optical system(s), moveable platform(s), elevator platform(s), recoating system(s) and at least one polymer retaining receptacle. Multiple polymer retaining receptacles may be arranged in a moveable apparatus, wherein each receptacle is adapted to actively/passively maintain a uniform, desired level of polymer by including a recoating device and a material fill/remove system. The platform is movably accessible to the polymer retaining receptacle(s), elevator mechanism(s) and washing and curing/drying area(s) which may be housed in a shielded enclosure(s). The elevator mechanism is configured to vertically traverse and rotate the platform, thus providing angled building, washing and curing/drying capabilities. A horizontal traversing mechanism may be included to facilitate manufacturing between components of SL cabinet(s) and/or alternative manufacturing technologies.

36 MATERIALS SCIENCE↗

ASSESMENT OF IMPURITIES IN NP METAL USING DOUBLE-FOCUSING SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards [1]. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing [2], with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture [2]. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of na

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vanadium metal-organic framework for selective adsorption

A permanently porous vanadium(II)-containing metal-organic framework (MOF) with vanadium(II) centers and methods for synthesis of such MOF frameworks are provided. Methods for using such compounds to selectively react with N2 over CH4 are provided. In the synthetic methods, a vanadium source, such as VY2(tmeda)2, where Y is a halogen and tmeda is N,N,N′,N′-tetramethylethane-1,2-diamine and a H2(ligand) are reacted in the presence of acid in a solvent at between 110° C. and 130° C. to form an intermediate product. The intermediate product is collected and washed with a washing agent, such as DMF and acetonitrile, and the vanadium(II) based MOF is activated by heating the washed intermediate product to at least 160° C. under dynamic vacuum.

Long, Jeffrey R.↗

Evaluation of Background Concentrations of Contaminants in an Unusual Desert Arroyo Near a Uranium Mill Tailings Disposal Cell - 12260

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) manages 27 sites that have groundwater containing uranium concentrations above background levels. The distal portions of the plumes merge into background groundwater that can have 50 μg/L or more uranium. Distinguishing background from site-related uranium is often problematic, but it is critical to determining if remediation is warranted, establishing appropriate remediation goals, and evaluating disposal cell performance. In particular, groundwater at disposal cells located on the upper Cretaceous Mancos Shale may have relatively high background concentrations of uranium. Elevated concentrations of nitrate, selenium, and sulfate accompany the uranium. LM used geologic analogs and uranium isotopic signatures to distinguish background groundwater from groundwater contaminated by a former uranium processing site. The same suite of contaminants is present in groundwater near former uranium processing sites and in groundwater seeps emanating from the Mancos Shale over a broad area. The concentrations of these contaminants in Many Devils Wash, located near LM's Shiprock disposal cell, are similar to those in samples collected from many Mancos seeps, including two analog sites that are 8 to 11 km from the disposal cell. Samples collected from Many Devils Wash and the analog sites have high AR values (about 2.0)-in contrast, groundwater samples collected near the tailings disposal cell have AR values near 1.0. These chemical signatures raise questions about the origin of the contamination seeping into Many Devils Wash. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Rangeland Evapotranspiration on Groundwater Recharge, Discharge, and Flow at the Tuba City, Arizona, Disposal Site - 17159

The US Department of Energy Office of Legacy Management is modeling groundwater flow and contaminant transport at a former uranium mill site near Tuba City, Arizona. A goal is to project groundwater travel times and flow volumes between the former mill site and Moenkopi Wash, a down-gradient stream. Aquifer recharge and discharge are sensitive model parameters; however, assigning representative rates is inexact and involves approximations. We applied a remote sensing algorithm to determine spatially variable evapotranspiration (ET), precipitation recharge, and groundwater discharge rates for use in a large scale groundwater flow model for the site. ET is the combination of evaporation and plant transpiration from soil and groundwater. We estimated landscape-scale ET over a 13-year period (2000 to 2012) for distinct plant communities within a 3531-hectare groundwater model domain (GMD), and then evaluated effects of ET on groundwater recharge and discharge within the GMD. Our empirical algorithm was derived from ground ET measurements, multispectral satellite imagery, and temperature data. Groundwater recharge or discharge rates were calculated for each plant community (or ET Zone) as the difference between precipitation (PPT) and ET rates. Recharge occurred in plant communities where PPT exceeded ET; discharge occurred where ET exceeded PPT. Estimates of groundwater recharge rates for upland plant communities that survive on meteoric water ranged from 0 to 88 mm yr{sup -1}. Estimates of groundwater discharge for phreatophyte plant communities ranged from 23 mm yr{sup -1} to 150 mm yr{sup -1}. Phreatophytes are plants that survive by extracting groundwater. Zero recharge occurred in plant communities where ET rates equaled annual average precipitation. An increase in groundwater recharge (PPT > ET) was associated with past land disturbances and heavy livestock grazing in upland areas. Groundwater discharge (ET > PPT) was highest in riparian phreatophyte communities, but lower than optimal in upland phreatophyte communities impacted by heavy grazing. Protecting phreatophyte communities from grazing at Tuba City could potentially increase ET from 153 mm yr{sup -1} to at least 500 mm yr{sup -1}. The validity of using the ET algorithm to estimate recharge and discharge was evaluated by comparing the net volumetric outflow rate for the model domain with base flow measurements collected from Moenkopi Wash. Modeled outflow approximated measured flow gains in the Wash, increasing our confidence in the ET algorithm and in the model. Results suggest that rangeland management practices that reduce groundwater recharge rates and increase groundwater discharge rates should be evaluated as part of an overall groundwater remediation strategy. (authors)

54 ENVIRONMENTAL SCIENCES↗

Groundwater Remediation in a Flood plain Aquifer at Shiprock, New Mexico - 16097

The Shiprock, New Mexico, Disposal Site is the location of a former uranium and vanadium ore-processing mill that operated from 1954 to 1968. During milling years, tailings leachate and other mill-related liquids migrated into underlying sediments, resulting in the contamination of groundwater beneath the river terrace containing the mill and a nearby flood plain alluvial aquifer adjacent to the San Juan River. The US DOE Office of Legacy Management manages the site and is implementing the current groundwater remedy for the flood plain area, consisting of natural flushing supplemented by extraction of alluvial groundwater to accelerate reduction in contaminant concentrations. The alluvial aquifer contains elevated concentrations of sulfate, uranium, and nitrate derived largely from the historical eastward migration of groundwater through terrace alluvium and underlying bedrock to the flood plain. The bedrock formation beneath the entire Shiprock site is Mancos shale, which forms an escarpment that separates the terrace from the flood plain. Contamination in the flood plain alluvial aquifer is influenced by a dynamic flow system that changes seasonally and from year to year. Simulations with a flood plain flow model based on monitored groundwater levels and coincident river-surface elevations show that background groundwater flow, unaffected by remediation pumping, is characterized by distinct hydraulic conditions for three separate periods each year. During months of low river flow in winter and early spring, river losses to the aquifer create a large hypo-rheic zone in the south half of the flood plain. Simultaneously, recharge of continually flowing surface water emptying onto the north half of the flood plain from Bob Lee Wash creates divergent, radial flow from the wash outlet and diverts northwestward-migrating contaminant plumes to the northeast where they discharge to the river. Subsequent bank storage processes in May and June from high snow melt runoff change background flow directions, increasing the spread of contamination in the alluvium. From mid-summer through fall, river flows are typically similar in value to those observed prior to the onset of snow melt, but groundwater elevations in the aquifer are noticeably lower than water levels observed in winter and early spring and may induce river losses to the aquifer. Several different contaminant sources have impacted the alluvial aquifer. Much of the contamination originated as tailings leachate and raffinate wastewater that infiltrated the terrace subsurface and eventually reached the flood plain at the escarpment. Additional sources of contamination in the aquifer included discharge of mill effluent to Bob Lee Wash and a pond at the base of the escarpment, and aqueous mobilization of solid-phase contamination in the form of windblown deposits and contaminants adsorbed to alluvial sediments. The degree to which remnant, secondary-source processes, such as leaching of solid-phase deposits and discharge of terrace groundwater across the escarpment, contribute to existing contaminant plumes is uncertain. The flood plain remediation system consists of two groundwater extraction wells, pumping from two horizontal wells placed in trenches near the base of the escarpment, a sump collecting discharges from seeps in the escarpment wall, and discharge of collected water to an evaporation pond on the terrace. Flow-model simulations indicate that most contaminated areas are captured by remediation pumping, resulting in several zones of freshwater between the river and the escarpment. Despite the highly transient nature of groundwater flow beneath the flood plain and the varied contaminant sources, initiation of remediation pumping in 2003 and coordinated operation of the system's various components have successfully removed large amounts of contaminant mass and helped prevent discharge of contaminated groundwater to the river. The percentage reductions of dissolved sulfate, uranium, and nitrate mass in the aquifer estimated for the first 9 years of remediation range from 40% to 72%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of Wide Area Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles - 16508

Researchers at the U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the 'Wide-Area Urban Radiological Contaminant, Mitigation, and Clean-Up Technology Demonstration' in Columbus, Ohio on June 22-25, 2015. EPA's National Homeland Security Research Center (NHSRC) demonstrated five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) on an urban building. Decontamination technologies were applied to remove the contaminants from the building's surfaces by physical, chemical, or other methods, which in practice could reduce radiation exposure level. In addition, NHSRC teamed with the Department of Homeland Security (DHS) to demonstrate several radiological contaminant mitigation technologies including building and vehicle wash technologies, as well as several approaches to contain wash water and radioactive particles. 'Radiological contaminant mitigation' technologies are measures taken to reduce adverse impacts of radiological contamination on people and the environment, and facilitate such purposes as restoration of first responder services and critical infrastructure. Radiological contaminant mitigation technologies are designed for containing and removing radiological contamination on the surface in the first hours or days following a radiological event (early phase response). Such technologies include 'radiological particle containment', which is design to prevent the spread of particles which might result from vehicle or foot traffic. Radiological particle containment technologies are applicable for early phase response to contain the radionuclides and to reduce radiation dose to responders and the public. Mitigation also includes 'gross decontamination' technologies, which perform a type of decontamination that is conducted with the goal of reducing contamination levels. This reduction may not meet final cleanup levels, but may be useful to mitigate some public hazard or contain contamination. The purpose of the demonstrations was to educate potential end-users and stakeholders of this technology about a 'Toolbox of Options' for radiological decontamination, as well as radiological contaminant mitigation. Both demonstrations were conducted using a 75-year old brick building and the surrounding area (including parking lots) in Columbus, OH. No radioactive contaminants were applied during either demonstration, as the objective was to duplicate and implement realistic operational conditions for these technologies. Surrogate contaminants such as particle tracers were used in several demonstrations. The decontamination technologies were used in a scaled-up setting with application to the building. Contaminant mitigation technologies were demonstrated on the building as well as on vehicles. Example technology application techniques/accessories included an articulating boom lift, repelling boatswain chair, stand-alone surface material structures, high-volume foam applicators, fire truck foam applicator, a vehicle wash tent for vehicles, particle tracers to simulate radiological contaminants, and high- and low-technology liquid containment approaches. Results and stakeholder observations from the demonstration are now publically in a report entitled 'Technical Report for the Demonstration of Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles' available at http://www.epa.gov/hsresearch Example information that was obtained included decontamination rate, contaminant mitigation and containment capacity, user friendliness of each technology, the required utilities (electric, water, etc.) for each technology, skill of worker required, and the cost. The condition (color, texture, integrity, etc.) of each building material present on the structure along with all structural components such as gutters, windows, doors, etc. were carefully examined and documented. All demonstrations were open to individuals, organizations, and local, state, federal, tribal, and international governments who may be involved with implementing or planning radiological incident response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗