Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Vessel Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The heart works against gravity

The circulatory systems of vertebrate animals are closed, and blood leaves and returns to the heart at the same level. It is often concluded, therefore, that the heart works only against the viscous resistance of the system, not against gravity, even in vascular loops above the heart in which the siphon principle operates. However, we argue that the siphon principle does not assist blood flow in superior vascular loops if any of the descending vasculature is collapsible. If central arterial blood pressure is insufficient to support a blood column between the heart and the head, blood flow ceases because of vascular collapse. Furthermore, the siphon principle does not assist the heart even when a continuous stream of blood is flowing in a superior loop. The potential energy gained by blood as it is pumped to the head is lost to friction in partially collapsed descending vessels and thus is not regained. Application of the Poiseuille equation to flow in collapsible vessels is limited; resistance depends on flow rate in partially collapsed vessels with no transmural pressure difference, but flow rate is independent of resistance. Thus the pressure developed by the heart to establish a given flow rate is independent of the resistance occurring in the partially collapsed vessels. The pressure depends only on the height of the blood column and the resistance in the noncollapsed parts of the system. Simple laboratory models, involving water flow in collapsible tubing, dispel the idea that the siphon principle facilitates blood flow and suggest that previously published results may have been affected by experimental artifact.

Review, Tutorial↗

Joule-Heated Molten Regolith Electrolysis Reactor Concepts for Oxygen and Metals Production on the Moon and Mars

The maturation of Molten Regolith Electrolysis (MRE) as a viable technology for oxygen and metals production on explored planets relies on the realization of the self-heating mode for the reactor. Joule heat generated during regolith electrolysis creates thermal energy that should be able to maintain the molten phase (similar to electrolytic Hall-Heroult process for aluminum production). Self-heating via Joule heating offers many advantages: (1) The regolith itself is the crucible material, it protects the vessel walls (2) Simplifies the engineering of the reactor (3) Reduces power consumption (no external heating) (4) Extends the longevity of the reactor. Predictive modeling is a tool chosen to perform dimensional analysis of a self-heating reactor: (1) Multiphysics modeling (COMSOL) was selected for Joule heat generation and heat transfer (2) Objective is to identify critical dimensions for first reactor prototype.

Sibille, Laurent↗

Compatibility Assessment Tool

In support of ground system development for the Space Launch System (SLS), engineers are tasked with building immense engineering models of extreme complexity. The various systems require rigorous analysis of pneumatics, hydraulic, cryogenic, and hypergolic systems. There are certain standards that each of these systems must meet, in the form of pressure vessel system (PVS) certification reports. These reports can be hundreds of pages long, and require many hours to compile. Traditionally, each component is analyzed individually, often utilizing hand calculations in the design process. The objective of this opportunity is to perform these analyses in an integrated fashion with the parametric CADCAE environment. This allows for systems to be analyzed on an assembly level in a semi-automated fashion, which greatly improves accuracy and efficiency. To accomplish this, component specific parameters were stored in the Windchill database to individual Creo Parametric models based on spec control drawings. These parameters were then accessed by using the Prime Analysis within Creo Parametric. MathCAD Prime spreadsheets were created that automatically extracted these parameters, performed calculations, and generated reports. The reports described component compatibility based on local conditions such as pressure, temperature, density, and flow rates. The reports also determined component pairing compatibility, such as properly sizing relief valves with regulators. The reports stored the input conditions that were used to determine compatibility to increase traceability of component selection. The desired workflow for using this tool would begin with a Creo Schematics diagram of a PVS system. This schematic would store local conditions and locations of components. The schematic would then populate an assembly within Creo Parametric, using Windchill database parts. These parts would have their attributes already assigned, and the MathCAD spreadsheets could begin running through database parts to determine which components would be suited for specific locations within the assembly. This eliminates a significant amount of time from the design process, and makes initial analysis assessments more accurate. Each component that would be checked for a location within the assembly would generate a report, showing whether the component was compatible. These reports could be used to generate the PVS report without the need to perform the same analysis multiple times. This process also has the potential to be expanded upon to further automate PVS reports. The integration of software codes or macros could be used to automatically check through hundreds of parts for each location on the schematic. If the software could recognize which type of component would be necessary for each location, it is possible that simply starting the macro could completely choose all the components needed for the schematic, and in turn the system. This would save many hours of work initially selecting components, which could end up saving money. Overall, this process helps to automate initial component selections for PVS systems to fit local design specifications. These selections will automatically generate reports showing how the design criteria are met by the specific component that was chosen. These reports will contribute to easier compilation of the PVS certification reports, which currently take a great amount of time and effort to produce.

Egbert, James Allen↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

Coupled Reactor Multiphysics and Mass Scalability Assessment for Crewed Megawatt-Class NEP System Architectures

Nuclear Electric Propulsion (NEP) is an in-space propulsion technology capable of enabling opposition and conjunction class crewed Mars missions. NEP subsystems include the reactor for heat generation, a power conversion system (PCS), power management and distribution, electric propulsion system, and heat rejection system. Specific mass, or α (kg/kWe), is a key performance parameter (KPP) of the propulsion system which is directly scalable with the performance and mass predictions for each individual component. To inform technology maturation planning activities, full system and component level parametric modeling is ongoing to explore the design trade space and illustrate the effect of subsystem design choices on the system KPPs. In this study, scaling of high-assay, low-enriched uranium reactor designs is assessed through coupled reactor physics and thermal hydraulics analyses. Scaling analyses evaluate the impact of system performance parameters (power level, interface temperatures) on mass for direct gas cooled, pumped liquid metal, and passively-cooled heat pipe reactor concepts. Each concept requires specific geometries, fluids, and power conversion interface conditions (temperature, pressure, flow rate) to meet desired performance and mass. The reactor assembly includes the active core (fuel, moderator, cladding, working fluid), axial and radial neutron reflectors, control drums, structural support / pressure vessel, and external radiation shielding. Each of these components are parametrically sized based on performance parameters for a megawatt-class power cycle. Results of this scaling analysis increase NEP propulsion system modeling fidelity and ultimately aim to support concept down-selection along with related technology development planning. The reactor and shield α are a function of several PCS and heat rejection system design choices, and reactor scaling with these parameters must be considered to enable an informed decision on an optimal reactor geometry and working fluid combination.

Nuclear Electric Propulsion↗

Coupled Reactor Multiphysics and Mass Scalability Assessment for Crewed Megawatt-Class NEP System Architectures

Nuclear Electric Propulsion (NEP) is an in-space propulsion technology capable of enabling opposition and conjunction class crewed Mars missions. NEP subsystems include the reactor for heat generation, a power conversion system (PCS), power management and distribution (PMAD), electric propulsion subsystem (EPS), and a primary heat rejection system. Specific mass, or αe (kg / kWe), is a key performance parameter (KPP) of the propulsion system which is directly scalable with the performance and mass estimates for individual components. To inform technology maturation planning, full system and component level parametric modeling is ongoing to explore the design trade space and illustrate the effect of subsystem design choices on the system KPPs. In this study, scaling of high-assay, low-enriched uranium (HALEU) reactor designs is assessed through coupled reactor physics and thermal hydraulics analyses. Scaling analyses evaluate the impact of system performance parameters (power level, interface temperatures) on mass for direct gas cooled, pumped liquid metal, and passively cooled heat pipe reactor concepts. Each concept requires specific geometries and working fluids to reach the performance goals of PCS interface conditions (temperature, pressure, flow rate) and system mass. The reactor assembly includes the active core (fuel, moderator, cladding, working fluid), axial and radial neutron reflectors, control drums, structural support / pressure vessel, and external radiation shielding. Each of these components are parametrically sized based on performance parameters for a megawatt-class power cycle. Results of this scaling analysis increase NEP propulsion system modeling fidelity and ultimately aim to support technology down-selection along with related technology development planning. The reactor and shield αe are a function of several PCS design choices, and reactor scaling with these parameters must be considered to enable an informed decision on reactor geometry and working fluid combination.

Nuclear Electric Propulsion↗

Status of SPV/CPV Testing

This presentation reviews the status test of Single Pressure Vessel (SPV)/Common Pressure Vessel (CPV) being conducted by the Navy. Slides review the design and tests by NASA, and the Airforce of CPV's. There are 5 different CPV models of CPV's which have been tested or are currently being tested for NASA and the Air Force. The batteries, tests, and results are presented. Graphs show the life cycle voltage, the pressure trend, the discharge/charge profile and the pressure profile for the batteries tested. Descriptions of those CPV batteries are given for those batteries which have been received but have not been tested. The development of the SPV is briefly described, followed by design specification for two packs from NASA and the Air Force. The acceptance test criteria are reviewed, followed by a review of the life cycle test conditions. The trend plots of voltage vs. cycle is given for the two packs. The end of charge, and the end of discharge voltages plots are shown. Plots showing the pressure and recharge vs. cycle are shown. Plots also show the voltage profiles. These plots are shown for both batteries using the SPV design submitted by NASA and the Air Force.

Brown, Harry↗

Acoustic isolation vessel for measurement of the background noise in microphones

An acoustic isolation vessel has been developed to measure the background noise in microphones. The test microphone is installed in an inner vessel, which is suspended within an outer vessel, and the intervening air space is evacuated to a high vacuum. An analytical expression for the transmission coefficient is derived, based on a five-media model, and compared to experiment. At an isolation vacuum of 5 x 10 exp -6 Torr the experimental transmission coefficient was found to be lower than -155 dB at frequencies ranging from 40 to 1200 Hz. Measurements of the A-weighted noise levels of commercial condenser microphones of four different sizes show good agreement with published values.

Ngo, Kim C. T.↗

Modeling of Biological Fluid Systems

This study presents a detailed methodology for modeling and validating three- dimensional fluid flow in realistic reconstructed vasculature geometry. Optical scanned data from a sectioned stenotic lumen having -65% area constriction within an arterial vessel of 9 mm diameter is processed and converted into a finite-element mesh. Mass and momentum transfer equations within the reconstructed stenotic vessel with a-flow rate of 200 ml/rnin is solved using the Galarkin Finite Element formulation. The calculated velocities at several axial locations along the length of the vessel are compared with the Particle Image Velocimetry (PIV) measurements. The computation results are in agreement with the initial steady state PIV measurements. In addition, initial results from pulsatile flow computations at different time points of a pulse cycle will be presented.

Banerjee, Rupak↗

Thermal Performance Expectations of the Advanced Stirling Convertor Over a Range of Operating Scenarios

Objectives of this work are: (1) Assist the Science Mission Directorate in developing technologies for space missions. (2) Explore the capability of computational modeling to assist in the development of the Advanced Stirling Convertor. (3) Baseline computational simulation with available experimental data of the ASC. (4) Calculate peak external pressure vessel wall temperatures and compare them with anticipated values. (5) Calculated peak magnet temperature inside the ASC over a range of operational scenarios.

Reid, Terry V.↗

Probabilistic Risk Assessment of Aging Layered Pressure Vessels

The National Aeronautics and Space Administration (NASA) operates approximately 300 aging layered pressure vessels that were designed and manufactured prior to ASME Boiler and Pressure Vessel (B&PV) code requirements. In order to make decisions regarding the continued fitness-for-service of these non-code carbon steel vessels, it is necessary to perform a relative risk of failure assessment for each vessel. However, risk assessment of these vessels is confounded by uncertainties and variabilities related to the use of proprietary materials in fabrication, missing construction records, geometric discontinuities, weld residual stresses, and complex service stress gradients in and around the welds. Therefore, a probabilistic framework that can capture these uncertainties and variabilities has been developed to assess the fracture risk of flaws in regions of interest, such as longitudinal and circumferential welds, using the NESSUS® probabilistic modeling software and NASGRO® fracture mechanics software. In this study, the probabilistic framework was used to predict variability in the stress intensity factor associated with different reference flaws located in the head-to-shell circumferential welds of a 4-layer and 14-layer pressure vessel. The probabilistic studies predict variability in flaw behavior and the important uncertain parameters for each reference flaw location.

Riha, D. S.↗

Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV using Temperature and Pressure Acceleration

Composite Overwrapped Pressure Vessel (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Sometimes lifetime testing is performed on an actual COPV in service in an effort to validate the reliability model that is the basis for certifying the continued flight worthiness of its sisters. Currently, testing of such a Kevlar49(registered TradeMark)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the data base and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one nine , that is, reducing the probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several would be necessary.

Phoenix, S. Leigh↗

Potential Applications of Modularity to Enable a Deep Space Habitation Capability for Future Human Exploration Beyond Low-Earth Orbit

Evaluating preliminary concepts of a Deep Space Habitat (DSH) enabling long duration crewed exploration of asteroids, the Moon, and Mars is a technically challenging problem. Sufficient habitat volumes and equipment, necessary to ensure crew health and functionality, increase propellant requirements and decrease launch flexibility to deliver multiple elements on a single launch vehicle; both of which increase overall mission cost. Applying modularity in the design of the habitat structures and subsystems can alleviate these difficulties by spreading the build-up of the overall habitation capability across several smaller parts. This allows for a more flexible habitation approach that accommodates various crew mission durations and levels of functionality. This paper provides a technical analysis of how various modular habitation approaches can impact the parametric design of a DSH with potential benefits in mass, packaging volume, and architectural flexibility. This includes a description of the desired long duration habitation capability, the definition of a baseline model for comparison, a small trade study to investigate alternatives, and commentary on potentially advantageous configurations to enable different levels of habitability. The approaches investigated include modular pressure vessel strategies, modular subsystems, and modular manufacturing approaches to habitat structure. The paper also comments upon the possibility of an integrated habitation strategy using modular components to create all short and long duration habitation elements required in the current exploration architectures.

Simon, Matthew A.↗

Concept for an On-orbit Capture and Orientation Module for Potential Mars Sample Return

An orbiting sample Capture and Orient Module (COM) architecture for a Capture, Contain, and Return System (CCRS) payload concept for an Earth Return Orbiter (ERO) was developed to enable on-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel for potential Mars Sample Return (MSR). The module is composed of a capture mechanism for containing the Orbiting Sample (OS), a capture cone to capture and contain the OS, an orientation mechanism to orient the OS, an External Transfer Mechanism (ETM) to cage the OS during capture and assemble it into the containment vessel, a capture trigger to trigger capture mechanism and ETM closure during OS capture, and a sensing system to inspect the OS and confirm capture and orientation. Statistical modeling and simulations of the OS during capture were performed to analyze the time to contact and perturbations to the spacecraft at first contact. A half-scale functional prototype of the module was developed to demonstrate end-to-end operation.

Younse, Paulo↗

The Relationship Between Constraint and Ductile Fracture Initiation as Defined by Micromechanical Analyses

The use of small laboratory specimens to predict the integrity of large, complex structures relies on the validity of single parameter fracture mechanics. Unfortunately, the constraint loss associated with large scale yielding, whether in a laboratory specimen because of its small size or in a structure because it contains shallow flaws loaded in tension, can cause the breakdown of classical fracture mechanics and the loss of transferability of critical, global fracture parameters. Although the issue of constraint loss can be eliminated by testing actual structural configurations, such an approach can be prohibitively costly. Hence, a methodology that can correct global fracture parameters for constraint effects is desirable. This research uses micromechanical analyses to define the relationship between global, ductile fracture initiation parameters and constraint in two specimen geometries (SECT and SECB with varying a/w ratios) and one structural geometry (circumferentially cracked pipe). Two local fracture criteria corresponding to ductile fracture micromechanisms are evaluated: a constraint-modified, critical strain criterion for void coalescence proposed by Hancock and Cowling and a critical void ratio criterion for void growth based on the Rice and Tracey model. Crack initiation is assumed to occur when the critical value in each case is reached over some critical length. The primary material of interest is A516-70, a high-hardening pressure vessel steel sensitive to constraint; however, a low-hardening structural steel that is less sensitive to constraint is also being studied. Critical values of local fracture parameters are obtained by numerical analysis and experimental testing of circumferentially notched tensile specimens of varying constraint (e.g., notch radius). These parameters are then used in conjunction with large strain, large deformation, two- and three-dimensional finite element analyses of the geometries listed above to predict crack initiation loads and to calculate the associated (critical) global fracture parameters. The loads are verified experimentally, and microscopy is used to measure pre-crack length, crack tip opening displacement (CTOD), and the amount of stable crack growth. Results for A516-70 steel indicate that the constraint-modified, critical strain criterion with a critical length approximately equal to the grain size (0.0025 inch) provides accurate predictions of crack initiation. The critical void growth criterion is shown to considerably underpredict crack initiation loads with the same critical length. The relationship between the critical value of the J-integral for ductile crack initiation and crack depth for SECT and SECB specimens has been determined using the constraint-modified, critical strain criterion, demonstrating that this micromechanical model can be used to correct in-plane constraint effects due to crack depth and bending vs. tension loading. Finally, the relationship developed for the SECT specimens is used to predict the behavior of circumferentially cracked pipe specimens.

Panontin, Tina L.↗

Solar Particle Event Exposures and Local Tissue Environments in Free Space and on Martian Surface

Solar particle events (SPEs) are a concern to space missions outside Earth s geomagnetic field. The September 29, 1989 SPE is the largest ground-level event since February 23, 1956. It is an iron-rich event for which the spectra are well measured. Because ten times this event matches the ground level data of the February 1956 SPE, it is suggested that an event with ten-times the scaled spectra of the September 29, 1989 SPE be used as a worst case SPE for spacecraft design. For the worst case SPE, the input spectra were reconstructed using Nymmik's (1995) model for protons, the O and Fe ion spectra of Tylka et al. (1997) to evaluate the iron enhancement ratio, and the Solar Energetic Particle Baseline (SEPB) composition of McGuire et al. (1986) for the heavy ions. The necessary transport properties of the shielding materials and the astronaut s body tissues are evaluated using the HZETRN code. Three shield configurations (assumed to be aluminum) are considered: space suit taken as 0.3 g/sq cm, helmet/pressure vessel as 1 g/sq cm, and equipment room of 5 g/sq cm. A shelter is taken as 10 g/sq cm on the Martian surface. The effect of shielding due to the Martian atmosphere is included. The astronaut geometry is taken from the computerized anatomical man (CAM) model.

Kim, M. Y.↗

Alterations in Skeletal Muscle Microcirculation of Head-Down Tilted Rats

In this study we assessed the function of microscopic blood vessels in skeletal muscle (cremaster muscle) for alterations which may contribute to the observed elevation of blood pressure associated with head-down tilted whole body suspension (HDT/WBS), a model of weightlessness. Arteriolar baseline diameters, vasoconstrictor responses to norepinephrine (NE) and vasodilation to nitroprusside (NP) were assessed in control rats, rats suspended for 7 or 14 day HDT/WBS rats, and rats allowed to recover for 1 day after 7 days HDT/WBS. Neither baseline diameters nor ability to dilate were influenced by HDT/WBS. Maximum vasoconstriction to norepinephrine was significantly greater in arterioles of hypertensive 14 day HDT/WBS rats. This first study of the intact microvasculature in skeletal muscle indicates that an elevated contractility of arterioles to norepinephrine in suspended rats, and suggests an elevated peripheral resistance in striated muscle may contribute to the increase in blood pressures among animals subjected to HDT/WBS.

Musacchia, X. J.↗