At least 199 records · Page 11

Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy

Dated at approximately 3.9 billion years of age, carbonate disks, found within fractures of the host rock of Martian meteorite ALH84001, have been interpreted as secondary minerals that formed at low temperature in an aqueous medium. Heterogeneously distributed within these disks are magnetite nanocrystals that are of Martian origin. Approximately one quarter of these magnetites have morphological and chemical similarities to magnetite particles produced by magnetotactic bacteria strain MV-1, which are ubiquitous in aquatic habitats on Earth. Moreover, these types of magnetite particles are not known or expected to be produced by abiotic means either through geological processes or synthetically in the laboratory. The remaining three quarters of the ALH84001 magnetites are likely products of multiple processes including, but not limited to, precipitation from a hydrothermal fluid, thermal decomposition of the carbonate matrix in which they are embedded, and extracellular formation by dissimilatory Fe-reducing bacteria. We have proposed that the origins of magnetites in ALH84001 can be best explained as the products of multiple processes, one of which is biological. Recently the three-dimensional (3-D) external morphology of the purported biogenic fraction of the ALH84001 magnetites has been the subject of considerable debate. We report here the 3-D geometry of biogenic magnetite crystals extracted from MV-1 and of those extracted from ALH84001 carbonate disks using a combination of high resolution classical and tomographic transmission electron microscopy (TEM). We focus on answering the following questions: (1) which technique provides adequate information to deduce the 3-D external crystal morphology?; and, (2) what is the precise 3-D geometry of the ALH84001 and MV-1 magnetites?

Thomas-Keprta, Kathie L.↗

Novel Focused Ion Beam Liftouts for Spatial Characterization of Spherical Biominerals With Transmission Electron Microscopy

Abstract Focused ion beam (FIB) is frequently used to prepare electron- and X-ray-beam-transparent thin sections of samples, called lamellae. Typically, lamellae are prepared from only a subregion of a sample. In this paper, we present a novel approach for FIB lamella preparation of microscopic samples, wherein the entire cross-section of the whole sample can be investigated. The approach was demonstrated using spherical, porous, and often hollow microprecipitates of biologically precipitated calcium carbonate. The microprecipitate morphology made these biogenic samples more fragile and challenging than materials commonly investigated using FIB lamellae. Our method enables the appropriate orientation of the lamellae required for further electron/X-ray analyses after attachment to the transmission electron microscopy (TEM) grid post and facilitates more secure adhesion onto the grid post. We present evidence of autofluorescence in bacterially precipitated vaterite using this lamella preparation method coupled with TEM selected area diffraction. This innovative approach allows studying biomineralization at the micro to nano scales, which can provide novel insights into bacterial responses to microenvironmental conditions.

47 OTHER INSTRUMENTATION↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

An In Situ transmission electron microscopy study on the synergistic effects of Au-ion irradiation and high temperature on nuclear graphite microstructure

Abstract The combined effects of high-temperature and heavy-ion irradiation on Mrozowski cracks (MC) and nuclear graphite crystallographic dimensions have been studied using in situ heating and in situ ion-irradiation in the transmission electron microscope (TEM). Electron transparent lamella of nuclear graphite, IG-110, was irradiated using a 2.8 MeV Au beam at an ion flux of 3.991 ×10 10 ion cm −2 s −1 for 70 min at 800 °C. Upon high-temperature irradiation, Mrozowski crack closure was studied quantitatively. The analysis showed linear, positive expansion of nuclear graphite which is significantly different from the dimensional changes previously reported for low-dose neutron irradiation of nuclear graphite in which the material undergoes negative to positive expansion via a turnaround radiation dose. The trend of the thermal expansion coefficient (CTE) of pristine IG-110 in this study is consistent with previous reports in the 100 °C–800 °C temperature region in which the dimensional change ranges from negative to positive values.

36 MATERIALS SCIENCE↗

Surprisingly high irradiation-induced defect mobility in Fe 3 O 4 as revealed through in situ transmission electron microscopy

Radiation-induced defects are expected to change the corrosion kinetics when a material is exposed to a corrosive environment. Characterization of the defects forming under irradiation and their ability to move/diffuse is therefore key to understanding how they impact the corrosion kinetics and possibly mechanisms. For that matter, Fe/Fe 3 O 4 interfaces were irradiated using 1 MeV Kr 2+ at temperatures of 273 K (25 °C), 573 K (300 °C) and 773 K (500 °C) to a maximum dose of 10 dpa (as measured in the Fe matrix) in situ in a transmission electron microscope. The evolution of the microstructure was followed as a function of the dose and temperature. The formation of defects was followed in the metal and the oxide as well as at the metal/oxide interface and characterized in terms of size and density. Additionally, the dynamic observation of the spatial distribution of the defects allowed for a qualitative assessment of the mobility of defects in the oxide as a function of temperature, revealing evidence for enhanced mobility even more so than in the Fe matrix. Mechanisms of induced defect mobility in the spinel are discussed to account for the observations.

36 MATERIALS SCIENCE↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Physics Discovery in Nanoplasmonic Systems via Autonomous Experiments in Scanning Transmission Electron Microscopy

Abstract Physics‐driven discovery in an autonomous experiment has emerged as a dream application of machine learning in physical sciences. Here, this work develops and experimentally implements a deep kernel learning (DKL) workflow combining the correlative prediction of the target functional response and its uncertainty from the structure, and physics‐based selection of acquisition function, which autonomously guides the navigation of the image space. Compared to classical Bayesian optimization (BO) methods, this approach allows to capture the complex spatial features present in the images of realistic materials, and dynamically learn structure–property relationships. In combination with the flexible scalarizer function that allows to ascribe the degree of physical interest to predicted spectra, this enables physical discovery in automated experiment. Here, this approach is illustrated for nanoplasmonic studies of nanoparticles and experimentally implemented in a truly autonomous fashion for bulk‐ and edge plasmon discovery in MnPS 3 , a lesser‐known beam‐sensitive layered 2D material. This approach is universal, can be directly used as‐is with any specimen, and is expected to be applicable to any probe‐based microscopic techniques including other STEM modalities, scanning probe microscopies, chemical, and optical imaging.

42 ENGINEERING↗

Reshaping of Truncated Pd Nanocubes: Energetic and Kinetic Analysis Integrating Transmission Electron Microscopy with Atomistic-Level and Coarse-Grained Modeling

Stability against reshaping of metallic fcc nanocrystals synthesized with tailored far-from-equilibrium shapes is key to maintaining optimal properties for applications such as catalysis. Yet Arrhenius analysis of experimental reshaping kinetics, and appropriate theory and simulation, is lacking. As such, we use TEM to monitor the reshaping of Pd nanocubes of ~25 nm side length between 410 °C (over ~4.5 h) and 440 °C (over ~0.25 h), extracting a high effective energy barrier of E eff ≈ 4.6 eV. We also provide an analytic determination of the energy variation along the optimal pathway for reshaping that involves transfer of atoms across the nanocube surface from edges or corners to form new layers on side {100} facets. The effective barrier from this analysis is shown to increase strongly with the degree of truncation of edges and corners in the synthesized nanocube. Theory matches experiment for the appropriate degree of truncation. In addition, we perform simulations of a stochastic atomistic-level model incorporating a realistic description of diffusive hopping for undercoordinated surface atoms, thereby providing a visualization of the initial reshaping process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An in situ ambient and cryogenic transmission electron microscopy study of the effects of temperature on dislocation behavior in CrCoNi-based high-entropy alloys with low stacking-fault energy

Temperature is known to affect deformation mechanisms in metallic alloys. As temperature decreases, the stacking-fault energy in many face-centered cubic (fcc) alloys decreases, resulting in a change of deformation mode from dislocation slip to deformation twinning. Such an impact of temperature can be more complex in compositionally heterogeneous microstructures that exhibit, for example, local concentration fluctuation such as that in multi-principal element alloys. In this work, we compare the dislocation behavior and mechanical properties of a fcc Cr 20 Mn 10 Fe 30 Co 30 Ni 10 high-entropy alloy at ambient and liquid-nitrogen temperatures. We find that a network of stacking faults is formed by uniformly extended dislocations at ambient temperatures with low stacking-fault energy, whereas at lower temperatures, uneven dissociation of dislocations becomes significant, which results in severe dislocation pile-ups together with their pronounced entanglement. Our findings indicate that as the stacking-fault energy decreases with decreasing temperature, the heterogeneity of the distribution of elements becomes more dominant in tuning the local variation of lattice resistance. As a result, the change in dislocation behavior at low temperatures strongly affects microstructural evolution and consequently leads to significantly more pronounced work hardening.

36 MATERIALS SCIENCE↗

3D Nanotomography of calcium silicate hydrates by transmission electron microscopy

Calcium silicate hydrate (C-S-H), is the principal hydration product of Portland cement that mainly contributes to the physical and mechanical properties of concrete. This paper aims to investigate the three-dimensional structure of C-S-H with Ca/Si ratios of 1.0 and 1.6 at the nanoscale using electron tomography. The 3D reconstructions and selected region of interest analysis confirm that the morphology of both C-S-H materials are foil-like structures. Additionally, the difference between the two materials is the density of elongated structures. C-S-H with Ca/Si ratio 1.6 is clearly composed of denser particles compared to the other C-S-H material due to overlapping of the foil-like structure. Pore analysis shows that C-S-H 1.0 and C-S-H 1.6 have porosities 69.2% and 49.8% respectively. Pore size distribution also reveals that C-S-H 1.0 has pore size range between 0-250 nm and C-S-H 1.6 between 0-100 nm. The pore network's size of C-S-H 1.0 is significantly larger than 1.6. This study illustrates the capability of using electron tomography to determine the 3D nanoscale structure of cementitious products and to distinguish between C-S-H 1.0 and 1.6.

42 ENGINEERING↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Leveraging generative adversarial networks to create realistic scanning transmission electron microscopy images

Abstract The rise of automation and machine learning (ML) in electron microscopy has the potential to revolutionize materials research through autonomous data collection and processing. A significant challenge lies in developing ML models that rapidly generalize to large data sets under varying experimental conditions. We address this by employing a cycle generative adversarial network (CycleGAN) with a reciprocal space discriminator, which augments simulated data with realistic spatial frequency information. This allows the CycleGAN to generate images nearly indistinguishable from real data and provide labels for ML applications. We showcase our approach by training a fully convolutional network (FCN) to identify single atom defects in a 4.5 million atom data set, collected using automated acquisition in an aberration-corrected scanning transmission electron microscope (STEM). Our method produces adaptable FCNs that can adjust to dynamically changing experimental variables with minimal intervention, marking a crucial step towards fully autonomous harnessing of microscopy big data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗