Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient heat flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Transient heat transfer of superfluid He 4 in nonhomogeneous geometries: Second sound, rarefaction, and thermal layer

Transient heat transfer in superfluid 4 He (He II) is a complex process that involves the interplay of the unique counterflow heat-transfer mode, the emission of second-sound waves, and the creation of quantized vortices. Many past researches focused on homogeneous heat transfer of He II in a uniform channel driven by a planar heater. Here, we report our systematic study of He II transient heat transfer in nonhomogeneous geometries that are pertinent to emergent applications. By solving the He II two-fluid equations of motion coupled with Vinen's equation for vortex-line density, we examine and compare the characteristics of transient heat transfer from planar, cylindrical, and spherical heaters in He II. Our results show that as the heater turns on, an outgoing second-sound pulse emerges, within which the vortex-line density grows rapidly. These vortices attenuate the second sound and result in a heated He II layer in front of the heater, i.e., the thermal layer. In the planar case where the vortices are created throughout the space, the second-sound pulse is continuously attenuated, leading to a thick thermal layer that diffusely spreads following the heat pulse. On the contrary, in the cylindrical and the spherical heater cases, vortices are created mainly in a thin thermal layer near the heater surface. As the heat pulse ends, a rarefaction tail develops following the second-sound pulse, in which the temperature drops. This rarefaction tail can promptly suppress the thermal layer and take away the deposited thermal energy. The effects of the heater size, heat flux, pulse duration, and temperature on the thermal-layer dynamics are discussed. We also show how the peak heat flux for the onset of boiling in He II can be studied in our model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entry environmental simulation testing of REI-Mullite TPS

Glassy fibrous mullite coatings exhibit noncatalytic surface characteristics which limit surface temperature rise under certain convective heat flux conditions. Thermal conductivity design curves provide good agreement with test results. The inclusion of shine-in effects results in improved accuracy of transient temperature gradient predictions for the materials.

Florence, D. E.↗

Minnowbrook IV: 2003 Workshop on Transition and Unsteady Aspects of Turbomachinery Flows

This Minnowbrook IV 2003 workshop on Transition and Unsteady Aspects of Turbomachinery Flows includes the following topics: 1) Current Issues in Unsteady Turbomachinery Flows; 2) Global Instability and Control of Low-Pressure Turbine Flows; 3) Influence of End Wall Leakage on Secondary Flow Development in Axial Turbines; 4) Active and Passive Flow Control on Low Pressure Turbine Airfoils; 5) Experimental and Numerical Investigation of Transitional Flows as Affected by Passing Wakes; 6) Effects of Freestream Turbulence on Turbine Blade Heat Transfer; 7) Bypass Transition Via Continuous Modes and Unsteady Effects on Film Cooling; 8) High Frequency Surface Heat Flux Imaging of Bypass Transition; 9) Skin Friction and Heat Flux Oscillations in Upstream Moving Wave Packets; 10) Transition Mechanisms and Use of Surface Roughness to Enhance the Benefits of Wake Passing in LP Turbines; 11) Transient Growth Approach to Roughness-Induced Transition; 12) Roughness- and Freestream-Turbulence-Induced Transient Growth as a Bypass Transition Mechanism; 13) Receptivity Calculations as a Means to Predicting Transition; 14) On Streamwise Vortices in a Curved Wall Jet and Their Effect on the Mean Flow; 15) Plasma Actuators for Separation Control of Low Pressure Turbine Blades; 16) Boundary-Layer Separation Control Under Low-Pressure-Turbine Conditions Using Glow-Discharge Plasma Actuators; 17) Control of Separation for Low Pressure Turbine Blades: Numerical Simulation; 18) Effects of Elevated Free-Stream Turbulence on Active Control of a Separation Bubble; 19) Wakes, Calming and Transition Under Strong Adverse Pressure Gradients; 20) Transitional Bubble in Periodic Flow Phase Shift; 21) Modelling Spots: The Calmed Region, Pressure Gradient Effects and Background; 22) Modeling of Unsteady Transitional Flow on Axial Compressor Blades; 23) Challenges in Predicting Component Efficiencies in Turbomachines With Low Reynolds Number Blading; 24) Observations on the Causal Relationship Between Blade Count and Developing Rotating Stall in a Four Stage Axial Compressor; 25) Experimental and Numerical Study of Non-Linear Interactions in Transonic Nozzle Flow; 26) Clocking Effects on a Modern Stage and One-Half Transonic Turbine; 27) DNS and LES of Transition on Turbine Blades; 28) The Use of Cellular Automata in Modeling the Transition; 29) Predicting Unsteady Buffet Onset Using RANS Solutions; 30) Transition Modelling With the SST Turbulence Model and an Intermittency Transport; and 31) Equation Workshop Summary Transcript

LaGraff, John E.↗

Atomistic simulations of the thermal conductivity of liquids

We present a method based on sinusoidal approach to equilibrium molecular dynamics (SAEMD) to compute the thermal conductivity of liquids Similar to nonequilibrium molecular dynamics, and unlike equilibrium simulations based on the Green-Kubo formalism, the method only requires the calculation of forces and total energies. The evaluation of heat fluxes and energy densities is not necessary, thus offering the promise of efficiently implementing first principles simulations based on density functional theory or deep molecular dynamics. Our approach is a generalization of SAEMD for solids, where the thermal conductivity is computed in the steady state, instead of a transient regime, thus properly taking into account diffusive terms in the heat equation. We present results for liquid water at ambient conditions and under pressure and discuss simulation requirements to obtain converged values of the thermal conductivity as a function of size and simulation time.

36 MATERIALS SCIENCE↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

On the role of the seasonal cycle

The definition of the seasonal cycle as the projection of an atmospheric time series onto a suitably defined subset of orthogonal basis functions guarantees that any atmospheric covariance may be expressed as the sum of a seasonal cycle part and a transient part (where transient refers to departures from the seasonal cycle rather than the time mean). Results are presented for the seasonal cycle contribution to the zonally averaged fluxes of momentum and heat, and for the zonally averaged height variance, in data for: the winter season, the winter season with the Fourier basis set appropriate for the seven-year time series, and the seven-year mean. The Fourier basis set calculation indicates that the interannual variability of the momentum flux is dominated by the interactions between the seasonal cycle and the meteorologically low frequency flow.

Straus, D. M.↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Non-linear MHD modelling of edge localized modes suppression by resonant magnetic perturbations in ITER

Edge localized modes (ELMs) suppression by resonant magnetic perturbations (RMPs) was studied with the non-linear magneto-hydro-dynamic (MHD) code JOREK for the ITER H-mode scenarios at 15 MA, 12.5 MA, 10 MA/5.3 T. In this study, the main aim was to demonstrate that ELMs can be suppressed by RMPs while the divertor 3D footprints of heat and particle fluxes remain within divertor material limits. The unstable peeling–ballooning modes responsible for ELMs without RMPs were modelled first for each scenario using numerically accessible parameters for ITER. Then the stabilization of ELMs by RMPs was modelled with the same parameters. RMP spectra, optimized by the linear MHD MARS-F code, with main toroidal harmonics N = 2, N = 3, N = 4 have been used as boundary conditions of the computational domain of JOREK, including realistic RMP coils, main plasma, scrape off layer (SOL) divertor and realistic first wall. The model includes all relevant plasma flows: toroidal rotation, two fluid diamagnetic effects and neoclassical poloidal friction. With RMPs, the main toroidal harmonic and the non-linearly coupled harmonics remain dominant at the plasma edge, producing saturated modes and a continuous MHD turbulent transport thereby avoiding ELM crashes in all scenarios considered here. The threshold for ELM suppression was found at a maximum RMP coils current of 45 kAt–60 kAt compared to the coils maximum capability of 90 kAt. In the high beta poloidal steady-state 10 MA/5.3 T scenario, a rotating QH-mode without ELMs was observed even without RMPs. In this scenario with RMPs N = 3, N = 4 at 20 kAt maximum current in RMP coils, similar QH-mode behaviour was observed however with dominant edge harmonic corresponding to the main toroidal number of RMPs. The present MHD modelling was limited in time by few tens of ms after RMPs were switched on until the magnetic energy of the modes saturates. As a consequence the thermal energy was still evolving on this time scale, far from the ITER confinement time scale and hence only the form of 3D footprints on the divertor targets can be indicated within this set-up. Also note, that the divertor physics was missing in this model, so realistic values of fluxes are out of reach in this modelling. However the stationary 3D divertor and particle fluxes could be simply extrapolated from these results to the stationary situation considering that a large power fraction should be radiated in the core and SOL and only about 50 MW power is going to the divertor, which is an arbitrary, but reasonable number used here. The 3D footprints with RMPs show the characteristic splitting with the main RMP toroidal symmetry. The maximum radial extension of the footprints typically was ~20 cm in inner divertor and ~40 cm in outer divertor with stationary heat fluxes decreasing further out from the initial strike point from ~5 MW m ₋2 to ~1 MW m ₋2 assuming a total power in the divertor and walls is 50 MW. The heat fluxes remain within the divertor target and baffle areas, however with rather small margin in the outer divertor which could be an issue for the first wall especially in transient regimes when part of the plasma thermal energy is released due to switching on the RMP coils. This fact should be considered when RMPs are applied with a more favorable application before or soon after the L–H transition, although optimization is required to avoid increasing the L–H power threshold with RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TAP 2: A finite element program for thermal analysis of convectively cooled structures

A finite element computer program (TAP 2) for steady-state and transient thermal analyses of convectively cooled structures is presented. The program has a finite element library of six elements: two conduction/convection elements to model heat transfer in a solid, two convection elements to model heat transfer in a fluid, and two integrated conduction/convection elements to represent combined heat transfer in tubular and plate/fin fluid passages. Nonlinear thermal analysis due to temperature-dependent thermal parameters is performed using the Newton-Raphson iteration method. Transient analyses are performed using an implicit Crank-Nicolson time integration scheme with consistent or lumped capacitance matrices as an option. Program output includes nodal temperatures and element heat fluxes. Pressure drops in fluid passages may be computed as an option. User instructions and sample problems are presented in appendixes.

Thornton, E. A.↗

Combined roles of buoyancy and orientation in nucleate pool boiling

The paper presents results obtained during pool boiling from flat surfaces over body force levels of a/g = -1 to 0 to 20 for LN2 and R-113 under steady and transient conditions. Pyrex and metal surfaces are used. Particular attention is given to the case where the effective gravity is perpendicular to the heating surface. At the lower levels of heat flux with nucleate boiling, the heater surface superheat first increases and then decreases as the body force increases above a/g = 1. This is due to the greater contribution of nonboiling convection.

Merte, H., Jr.↗

An investigation of the magnetic field of Transient Disturbances (TD) at the Earth's orbit, and a determination of solar sources of TD from their characteristics at R = 1 AU

We have investigated and intercompared the typical features of the magnetic field of two types of solar wind transient disturbances with shock waves: the shock wave is accompanied by a magnetic cloud (MC), and the shock wave is followed by a region with bidirectional solar wind electron heat flux (BEHF), with no MC present. In this case, a separate study was made of the field features in two typical TD structures: in the region of impact-compressed solar wind between the shock wave and MC or BEHF, as well as in MC and BEHF. The study has provided new results on the influence of the ambient SW upon the TD magnetic field and the relationship between fields in various TD structures. A new test for the existence of interplanetary magnetic field draping around MC and BEHF is proposed and verified. It is concluded that the magnetic field configuration around MC is more adequately consistent with the concept of magnetic line draping than is the case around BEHF Two methods are proposed to infer the location of solar sources of TD from their characteristics at R = 1 AU.

Fainshtein, V. .G.↗

Detailed Physical Modeling Reveals the Magnetar Nature of a Transient Anomalous X-ray Pulsar

Anomalous X-ray Pulsars (AXPs) belong to a class of neutron stars believed to harbor the strongest magnetic fields in the universe, as indicated by their energetic bursts and their rapid spindowns. However, a direct measurement of their surface field strengths has not been made to date. It is also not known whether AXP outbursts result from changes in the neutron star magnetic field or crust properties. Here we report the first, spectroscopic measurement of the surface magnetic field strength of an AXP, XTE J1810-197, and solidify its magnetar nature. The field strength obtained from detailed spectral analysis and modeling is remarkably close to the value inferred from the rate of spindown of this source and remains nearly constant during numerous observations spanning over two orders of magnitude in source flux. The surface temperature, on the other hand, declines steadily and dramatically following the 2003 outburst of this source. Our findings demonstrate that heating occurs in the upper neutron star crust during an outburst and sheds light on the transient behaviour of AXPs.

Guever, T.↗

The Magnetar Nature and the Outburst Mechanism of a Transient Anomalous X-ray Pulsar

Anomalous X-ray Pulsars (AXPs) belong to a class of neutron stars believed to harbor the strongest magnetic fields in the universe, as indicated by their energetic bursts and their rapid spindowns. However, a direct measurement of their surface field strengths has not been made to date. It is also not known whether AXP outbursts result from changes in the neutron star magnetic field or crust properties. Here we report the first, spectroscopic measurement of the surface magnetic field strength of an AXP, XTE J1810-197, and solidify its magnetar nature. The field strength obtained from detailed spectral analysis and modeling is remarkably close to the value inferred from the rate of spindown of this source and remains nearly constant during numerous observations spanning over two orders of magnitude in source flux. The surface temperature, on the other hand, declines steadily and dramatically following the 2003 outburst of this source. Our findings demonstrate that heating occurs in the upper neutron star crust during an outburst and sheds light on the transient behaviour of AXPs.

Guver, Tolga↗

Space-time dependent thermal conductivity in nonlocal thermal transport

Nonlocal thermal transport is generally described by the Peierls-Boltzmann transport equation (PBE). However, solving the PBE for a general space-time dependent problem remains a challenging task due to the high dimensionality of the integro-differential equation. In this work, we present a direct solution to the space-time dependent PBE with a linearized collision matrix using an eigendecomposition method. We show that there exists a generalized Fourier-type relation that links heat flux to the local temperature, and this constitutive relation defines a thermal conductivity that depends on both time and space. Combining this approach with ab initio calculations of phonon properties, we demonstrate that the space-time dependent thermal conductivity gives rise to an oscillatory response in temperature in a transient grating geometry in high thermal conductivity materials. The present solution method allows us to extend the reach of our computational capability for heat conduction to space-time dependent nondiffusive transport regimes. Here, this capability will not only enable a more accurate interpretation of thermal measurements that observe nonlocal thermal transport, but also enhance our physical understanding of nonlocal thermal transport in high thermal conductivity materials that are promising candidates for nanoscale thermal management applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An evaluation of analog and numerical techniques for unsteady heat transfer measurement with thin-film gauges in transient facilities

The importance of frequency response considerations in the use of thin-film gages for unsteady heat transfer measurements in transient facilities is considered, and methods for evaluating it are proposed. A departure frequency response function is introduced and illustrated by an existing analog circuit. A Fresnel integral temperature which possesses the essential features of the film temperature in transient facilities is introduced and is used to evaluate two numerical algorithms. Finally, criteria are proposed for the use of finite-difference algorithms for the calculation of the unsteady heat flux from a sampled temperature signal.

George, William K.↗

Assessment of CTF for Steady-state and Transient Post-CHF Conditions in Support of Time-at-Temperature Modeling Applications

The US nuclear industry is exploring options to improve operational economics and uprate the current fleet of light-water reactors by investigating transitioning to cladding performance–based safety criteria as opposed to the current limit, which requires complete avoidance of critical heat flux (CHF)/dryout. Past experience has shown that not all events leading to a dryout are severe enough to cause fuel performance degradation. Allowing temporary dryout of the fuel—that is, using a time-at-temperature (TaT) strategy—could allow for economic improvements via large power uprates and enhanced operational flexibility for current plants without compromising fuel integrity. To support this effort, the US Department of Energy is executing a comprehensive program that includes generating cladding material data under TaT conditions, developing new mechanistic models, and demonstrating modeling and simulation capabilities for transients of interest. This paper presents work performed to assess the CTF thermal-hydraulics subchannel code. CTF is a package used in the VERA core simulator, which will ultimately be used for TaT analysis. CTF will provide the thermal-hydraulic boundary conditions that will be needed for fuel performance analysis in the BISON code. Quantifying both the accuracy and uncertainty of post-CHF models will therefore be necessary. This paper outlines the strategy for the assessment of TaT and presents the results of using the steady-state and transient dryout experiments of the Boiling Fine-mesh Bundle Tests for CTF validation. The results show that the current model tends to overpredict steady-state critical power. This behavior translates to the transient tests, in which CTF is unable to capture transient dryout behavior. Some discussion of sensitivity analysis work being performed is provided to indicate which models must be further analyzed to properly model transient dryout and its uncertainty.

Salko Jr, Robert [ORNL] (ORCID:0000000253566679)↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Dynamics of the Molten Contact Line

The purpose of this program is to develop a basic understanding of how a molten material front spreads over a solid that is below its melting point, arrests, and freezes. Our hope is that the work will contribute toward a scientific knowledge base for certain new applications involving molten droplet deposition, including the "printing" of arbitrary three-dimensional objects by precise deposition of individual molten microdrops that solidify after impact. Little information is available at this time on the capillarity-driven motion and arrest of molten contact line regions. Schiaffino and Sonin investigated the arrest of the contact line of a molten microcrystalline wax spreading over a subcooled solid "target" of the same material. They found that contact line arrest takes place at an apparent liquid contact angle that depends primarily on the Stefan number S=c(T(sub f) -T(sub t)/L based on the temperature difference between the fusion point and the target temperature, and proposed that contact line arrest occurs when the liquid's dynamic contact angle approaches the angle of attack of the solidification front just behind the contact line. They also showed, however, that the conventional continuum equations and boundary conditions have no meaningful solution for this angle. The solidification front angle is determined by the heat flux just behind the contact line, and the heat flux is singular at that point. By comparing experiments with numerical computations, Schiaffino and Sonin estimated that the conventional solidification model must break down within a distance of order 0.1 - 1 microns of the contact line. The physical mechanism for this breakdown is as yet undetermined, and no first-principles theory exists for the contact angle at arrest. Schiaffino and Sonin also presented a framework for understanding how to moderate Weber number molten droplet deposition in terms of similarity laws and experimentation. The study is based on experiments with three molten materials- molten wax on solid wax, water on ice, and mercury on frozen mercury- which between them span a considerable range of the deposition/solidification similarity parameters. Correlations are obtained for the spreading velocity, spreading time scales, the spreading factor (i.e. ratio of deposited drop's final footprint radius and the drop's initial radius), post-spreading liquid oscillation amplitudes and time scales, and bulk solidification time scales. Duthaler carried out an experimental and theoretical investigation of the relationship between the liquid's apparent contact angle and the Capillary number Ca=mu U/sigma based on contact line speed, for molten materials spreading over subcooled solids. This relationship is required for modeling of melt spreading. We have adapted Voinov's methodology to the molten contact line and formulated a theoretical model for the Ca vs. contact angle relationship, based Schiaffino and Sonin#s (1997a,b) wedge-like solidification front model. With the solidification front angle taken from Schiaffino and Sonin, the model is in good agreement with the experimental results for Ca vs. contact angle. Duthaler also extended the experimental investigation of droplet deposition and contact line freezing to more materials, including solder on glass, solder on solder, water on ice, and molten microcrystalline wax on wax. The latter also included tests on inclined targets. Deposition tests have also been done with molten octacosane (C28H58) on various targets. An important objective of our program has been the development of micron-scale sensors for measuring the transient temperature at a point on the substrate surface as a molten contact line moves over it. The expectation is that this temperature history will yield a better understanding of the thermal process in the contact line region. The sensors are of the thermistor type, either 2.5 microns or 1.5 microns square, microfabricated with silicon-based technology on either pure silicon or amorphous silicon dioxide chips. Each chip has 32 sensors distributed on its surface in arrays. The time response is better than 10 ms. At the time of writing, sensor calibration is in progress. Results on thermal transients during contact line passage will be discussed at the conference. While we expect that the data will provide information on the near-contact-line heat transfer process, we also foresee possible problems. First, the spatial resolution of the sensors may be insufficient to resolve the near-contact-line region. Second, the sensors protrude about 0.5 microns above the substrate surface, and may affect the contact line motion. Third, a sensor's temperature history depends on both the heat flux distribution into it from the fusion front and the thermal properties of the substrate below it and the solidified melt between it and the fusion front. The heat flux distribution in the contact line region must therefore be unfolded from computations of the overall system's transient thermal response.

Sonin, Ain A.↗