Impact of nuclear data covariance libraries on uncertainty quantification of sodium cooled fast reactor simulation

Uncertainty quantification in core modelling to assess reactor performance is a regular practice to identify design safety limits. Best-estimate plus uncertainty (BEPU) methods are commonly used to propagate uncertainties to core responses from input parameters, characterized by variance-covariance libraries. This study evaluates the impact of different covariance libraries on the uncertainty associated with core safety parameters and their propagation through reactor transient modelling for a metallic core (ABR-1000). The COMAC-1.0, COMMARA-2.0, and COMMARA-2.1 covariance libraries are used to propagate nuclear data uncertainties to neutron feedback coefficients using the Generalized Perturbation Theory, then through transient safety analyses to establish the confidence interval for safety performance of the reactor using stochastic sampling. The considered transients include Unprotected Transient Over Power and Unprotected Loss Of Flow. Most influential nuclide and reaction pairs in different variance-covariance libraries are identified and their impact on the uncertainty of safety parameters are evaluated. Significant differences were observed between uncertainties from COMAC compared to COMMARA libraries. Uncertainties from COMMARA libraries were consistently larger than COMAC for all cases. For structure, coolant density feedback coefficients and control rod worth, total nuclear data uncertainties were approximately 50% larger for COMMARA than COMAC. Differences were also observed in identification of top contributors of uncertainty in terms of reaction-cross sections. For instance, largest contribution to total uncertainty of radial expansion coefficient from COMMARA-2.0 and 2.1 originates from Na{sup 23} P1 Elastic cross section (0.81%) but from Pu{sup 239} Fission (0.53%) with COM C-1.0. Such differences are evaluated in this research for all quantities of interest. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Analysis and Design of an Advanced Space Suit

The thermal dynamics and design of an Advanced Space Suit are considered. A transient model of the Advanced Space Suit has been developed and implemented using MATLAB/Simulink to help with sizing, with design evaluation, and with the development of an automatic thermal comfort control strategy. The model is described and the thermal characteristics of the Advanced Space suit are investigated including various parametric design studies. The steady state performance envelope for the Advanced Space Suit is defined in terms of the thermal environment and human metabolic rate and the transient response of the human-suit-MPLSS system is analyzed.

Lin, Chin H.↗

An Evaluated, Transient Experiment based on Simultaneous, 3-D Neutron-Flux and Temperature Measurements

There is substantial interest in the validation of transient models for reactor physics, particularly in support of next-generation, high-fidelity tools like those developed by the U.S. DOE and other institutions. However, much existing data is limited largely to sparse or integral measurements in very large, complicated reactor systems. Moreover, meaningful transients are almost always driven by the complex coupling between neutronics and thermal-hydraulics. To address this data gap, a series of steady-state and transient experiments was conducted at the University of Wisconsin Nuclear Reactor that used several probes containing micro-pocket fission detectors (MPFDs) to measure neutron fluxes or resistance temperature detectors (RTDs) to measure coolant temperatures. Here, an overview of the experimental campaign is provided, as is a preliminary look of selected measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Systematic Modeling Uncertainties on Kilonova Property Estimation

The precise atomic structure and therefore the wavelength-dependent opacities of lanthanides are highly uncertain. This uncertainty introduces systematic errors in modeling transients like kilonovae and estimating key properties such as mass, characteristic velocity, and heavy metal content. Here, we quantify how atomic data from across the literature as well as choices of thermalization efficiency of r-process radioactive decay heating impact the light curve and spectra of kilonovae. Specifically, we analyze the spectra of a grid of models produced by the radiative transfer code Sedona that span the expected range of kilonova properties to identify regions with the highest systematic uncertainty. Our findings indicate that differences in atomic data have a substantial impact on estimates of lanthanide mass fraction, spanning approximately 1 order of magnitude for lanthanide-rich ejecta, and demonstrate the difficulty in precisely measuring the lanthanide fraction in lanthanide-poor ejecta. Mass estimates vary typically by 25%–40% for differing atomic data. Similarly, the choice of thermalization efficiency can affect mass estimates by 20%–50%. Observational properties such as color and decay rate are highly model dependent. Velocity estimation, when fitting solely based on the light curve, can have a typical error of ∼100%. Atomic data of light r-process elements can strongly affect blue emission. Even for well-observed events like GW170817, the total lanthanide production estimated using different atomic data sets can vary by a factor of ∼6.

Gravitational wave sources↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Math Problems for a Clean Energy Future

Cutting edge computational mathematics are ubiquitous in renewable energy research. Problems in resilient and reliable electric grid operations, infrastructure planning, wind farm yaw control, and more demand sophisticated and scalable computational tools that enable the transition of renewable energy technologies from proof of concept to deployment into our energy system. The mission of the Computational Science Center at NREL is to lead the lab's efforts to solve energy challenges using high-performance computing (HPC), computational science, applied mathematics, scientific data management, visualization, and informatics. In this poster, we provide a short overview of three areas of computational mathematics research at NREL: wind power scenario generation for stochastic grid operations and infrastructure planning, improved rational function approximations for electromagnetic transients codes, and wind farm yaw control using a combination of the Alternating Direction Method of Multipliers (ADMM) and reinforcement learning (RL). Increasing penetrations of renewable energy into power grids motivate the investigation of new approaches to characterizing uncertainty for five-minute economic dispatch problems. Similarly, as the penetration of distributed energy resources on power grids increases, it becomes important to revisit our methods of modelling transient phenomena, i.e. electromagnetic transients programs. Finally, the combination of ADMM and RL for wind farm yaw control presented here can potentially increase the efficiency of the deployed distributed controllers by orders of magnitude.

ADMM↗

Model for the 5 March 1979 gamma-ray transient

A model is proposed for the March 5, 1979 gamma-ray transient. A small lump of strange matter, previously ejected from a supernova explosion, struck a slowly rotating strange star. This resulted in a high-intensity flash of radiation from a hot spot produced by the impact. The high-intensity radiation blew open a crater in the crust; the energy released as this crater refilled was responsible for the longer-duration, lower-intensity phase. The 8-s modulation is due to the rotation of the star. A plausible scenario for the production of this event is discussed.

Alcock, Charles↗

Modeling of the transient ignition of a nonmetal/oxygen system by heterogeneous reaction - Effects of oxygen pressure

A theoretical model of the transient ignition of a nonmetallic polymer in a pure oxygen environment was developed and used to assess the safety of an oxygen system under elevated pressure. Results demonstrated that, for a general oxygen system, the ignition temperautre is sensitive to the external heating rate as well as such system parameters as the minimum ignition heat flux and the corresponding minimum ignition temperature. As the oxygen pressure increases, the minimum ignition temperature decreases, until, at a sufficiently high oxygen pressure, spontaneous ignition occurs. Numerical results generated by the model were correlated with the reported ignition data for polyethylene, Teflon, and nylon.

Yuen, Walter W.↗

CO 2 zonal injection rate allocation and plume extent evaluation through wellbore temperature analysis

Temperature analysis during a pause in injection operations, known as warmback analysis, has been used in the petroleum industry for evaluating the injection conformance and estimating the location of the flooded front in applications, such as waterflooding oil reservoirs. Here in this work, methods are introduced to extend the application of temperature warmback analysis to estimate the zonal CO 2 injection rate and zonal CO 2 plume extent during geologic CO 2 storage in a saline aquifer. First, novel analytical solutions are developed to model transient temperature in the aquifer during the injection and subsequent shut-in periods considering two-phase flow (gaseous CO 2 and aqueous brine) conditions in the aquifer. The solution involves a discretization of the aquifer into regions; the energy and mass conservation equations for the regions are solved simultaneously considering appropriate boundary conditions at the interfaces. Two solutions techniques are presented: multi-region and three-region solutions. Inverse models are developed accordingly to evaluate the injection profile and estimate the extent of the plume front in the reservoir during the injection period. The multi-region solution results in an inversion approach that requires regression analysis. However, the three-region formulation results in a simple graphical technique for inverse modeling. The analytical solutions are validated against a thermally coupled reservoir simulation tool using different synthetic cases for CO 2 injection in deep saline aquifers. The results of the developed solutions provide a good match with numerical results during forward and inverse modeling.

54 ENVIRONMENTAL SCIENCES↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

System-Level Design of a Shape Memory Alloy Actuator for Active Clearance Control in the High-Pressure Turbine

This paper describes results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 inches. Design results show that an actuator comprised of 10 wires 2 inches in length is adequate for control at critical engine operating points and still exhibits acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

DeCastro, Jonathan A.↗

Progress on Shape Memory Alloy Actuator Development for Active Clearance Control

Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

DeCastro, Jonathan↗

Updates and Correlation of EMU System-Level Model (SINDA EMU)

During United States Extravehicular Activity 80 (US EVA 80), water was observed in the helmet of an Extravehicular Mobility Unit (EMU) during cabin repressurization. One of the primary methods of determining the likely cause of this failure was through a comparison of EVA 80 to other historical EVAs using an analytical approach. The Systems Improved Numerical Differential Analysis EMU model (SINDA EMU) is a system-level model of the EMU that was used in this investigation. SINDA EMU was initially developed and correlated to test data in the 1980s. Since its conception, SINDA EMU has been continually adjusted based on new test data and changes to the EMU design. To support the water in the helmet investigation, SINDA EMU needed to be further updated and recorrelated to ensure accurate results. These changes included changing the primary carbon dioxide (CO2) removal technology, implementing logic to allow for re-evaporation of sweat runoff from the liquid cooling and ventilation garment (LCVG), and improving the transient modeling capabilities. To validate the implementation of these adjustments, SINDA EMU was correlated to test data from the 1990s and human-in-the-loop (HITL) testing from 2014. These updates and correlation efforts proved that SINDA EMU is an effective tool for investigating the EVA 80 water in the helmet failure event.

Noah Lial Andersen↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

An Evaluation of Co-Simulation for Modeling Coupled Natural Gas and Electricity Networks

Reliance on natural gas for power generation has increased the coupling between gas and power networks. While this coupling can bring operational and economic benefits, it can also yield challenges, as the constraints in one system can impact the other. Co-simulation can capture the constraints and interactions between these systems, but so far, there has been limited comparison of co-simulation results to those of an integrated model. In this work, we develop a new co-simulation framework using the HELICS platform and the SAInt tool for modeling transient gas and AC optimal power flow. We evaluate this co-simulation framework against a fully integrated version of the SAInt power and gas simulators, thus providing a benchmarking of the co-simulation approach. We compare results across the two approaches for two test networks and a network representing the Belgian power and gas networks, testing both normal operating conditions and cases with compressor disruptions. In each of the cases tested, we find nearly identical results from the two approaches across various metrics of interest, such as nodal pressure, gas flow rates, and active power generation. This alignment suggests that co-simulation can yield comparable results to fully integrated models for modeling coupled gas and electricity networks.

03 NATURAL GAS↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.