High sensitivity imaging Thomson scattering for low temperature plasma

A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a ''Generation III'' image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n{sub e}) and 6% in the electron temperature (T{sub e}) at n{sub e}=4x10{sup 19} m{sup -3}. This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9x10{sup 17} m{sup -3} in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n{sub e} and T{sub e} measurement is 7x10{sup 20}/n{sub e} J, which means that single shot measurements are possible for n{sub e}>2x10{sup 21} m{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Ion Collective Thomson Scattering Diagnostic for ITER - Progress of Design

In the era of high power and burning plasma fusion experiments with significant populations of fast particles, the diagnosis of fast ion dynamics becomes an important topic. In ITER, populations of fast ions due to ICRH and NBI, as well as fusion born alphas will carry a significant fraction of the free energy of the plasma. This may affect instabilities and transport in the plasma. A key candidate for diagnosing confined fast ions in ITER is the technique of collective Thomson scattering (CTS). A fast ion CTS system with a probing frequency of 60 GHz has been proposed for ITER. Based on diagnostic experience from particularly TEXTOR and ASDEX Upgrade, work is now progressing towards a final design of a fast ion CTS diagnostic for ITER. The biggest challenge of the diagnostic design is the HFS receiver located in the restricted space behind the blanket modules. Calculations and a series of mock-up measurements have brought the design towards a four mirror quasi-optical solution. The development as well as the present design will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Fast, Near-Infrared Photodetectors for the ITER Core LIDAR Thomson Scattering

A key component for the ITER core LIDAR Thomson Scattering (TS) diagnostic would be a detector with good sensitivity in the 850-1060 nm near infrared (NIR) spectral region. Covering this spectral region becomes necessary if a Nd:YAG laser system operating at {lambda} = 1.06 {mu}m is used as the laser source, which is a very attractive choice in terms of available energy, repetition rate, reliability and cost. In this paper we review the state of the art of two types of detectors available for the above spectral range: the transferred electron (TE) InGaAs/InP hybrid photodiode and the In{sub x}Ga{sub 1-x}As microchannel plate (MCP) image intensifier and we describe the advancements necessary for a possible application in the ITER LIDAR TS. In addition we describe the preliminary characterization of new GaAsP fast MCP photomultipliers (PMTs) suitable for the detection of the visible part of the LIDAR TS spectrum in JET and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dust Measurement With Thomson Scattering In FTU

The size distribution of dust particles present in FTU after disruptions has been evaluated in the range 0.05 {mu}m-0.1 {mu}m using the Thomson scattering system. Rayleigh approximation has been used to estimate the dust size. The distribution, although the radii considered do not differ more than an order of magnitude, behave like a power law. The laser energy density far exceed that necessary to vaporize, at least partially, the particles. This can affect the previous estimate of the particle sizes, and suggests that the effective radii might be larger than the estimated values. A preliminary analysis on the broad band signal is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson Scattering and Burning Plasmas

In low temperature plasmas, tokamaks and other experimental fusion devices, the electron temperature and densities in the plasma can be measured with high accuracy by detecting the effect of Thomson scattering of light from a high-intensity laser fired through the device. It has been established as a robust technique to measure these parameters and in particular it can be used to provide detailed profiles right through the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Study of the Observation Optics for the Thomson Scattering Planned at Wendelstein 7-X

The main aim of the Thomson scattering system is the measurement of electron temperature and density profiles with high time and spatial resolution. To cover the whole laser beam line (1.6 m) through the plasma cross section, two ports are provided for the observation optics, which image the scattering volumes (each with 28 mm length and 9 mm diameter) onto fiber bundles. The observation optics are important components of the diagnostic set-up, because their imaging properties determine the spectral and spatial resolution of the whole system. Therefore the design of the optics must be optimized according to the geometrical constrains of the observation ports in terms of position and dimensions. To optimize this optical engineering, the commercial ZEMAX program is used. The composition of the optical system is elaborated to minimize losses of collected light with wavelength from 700 nm up to 1064 nm. Environmental criteria (e.g. neutrons, ECR plasma heating and temperature) will be considered choosing optical materials. First results of calculations will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Calibration of a Polychromator for the Thomson Scattering at Wendelstein 7-X

On Wendelstein 7-X, electron density and electron temperature profiles are planned to be measured by Thomson scattering. The specific system employs fiber bundles for the scattered light which is detected by means of a five-channel polychromator system. The detection system is assembled and its components are characterized. A calibration technique employing a super-continuum light source is assessed by comparison with a calibration technique using an optical parametric oscillator laser system. The characterization is preparing further diagnostic optimization studies employing a virtual instrument.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electron temperature and density in an argon microdischarge by laser Thomson scattering

Laser Thomson scattering in a novel, backscattered configuration was employed to measure the electron temperature (T{sub e}) and electron density (n{sub e}) in argon dc microdischarges, with an interelectrode gap of 600 {mu}m. Measurements were performed at the center of the gap that corresponds to the positive column. For 50 mA microdischarge current and over the pressure range of 300-700 Torr, the plasma parameters were found to be T{sub e}=0.9{+-}0.3 eV and n{sub e}=(6{+-}3)x10{sup 13} cm{sup -3}, in reasonable agreement with the predictions of a mathematical model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Thomson scattering system on the lithium tokamak experiment

The lithium tokamak experiment (LTX) is a spherical tokamak with R{sub 0}=0.4 m, a=0.26 m, B{sub TF}{approx}3.4 kG, I{sub P}{approx}400 kA, and pulse length {approx}0.25 s. The goal of LTX is to investigate tokamak plasmas that are almost entirely surrounded by a lithium-coated plasma-facing shell conformal to the last closed magnetic flux surface. Based on previous experimental results and simulation, it is expected that the low-recycling liquid lithium surfaces will result in higher temperatures at the plasma edge, flatter overall temperature profiles, centrally peaked density profiles, and an increased confinement time. To test these predictions, the electron temperature and density profiles in LTX will be measured by a multipoint Thomson scattering system. Initially, TS measurements will be made at up to 12 simultaneous points between the plasma center and plasma edge. Later, high resolution edge measurements will be deployed to study the lithium edge physics in greater detail. Technical challenges to implementing the TS system included limited 'line-of-sight' access to the plasma due to the plasma-facing shell and problems associated with the presence of liquid lithium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multipoint Thomson scattering diagnostic for the Madison Symmetric Torus reversed-field pinch

The multipoint Thomson scattering diagnostic on the Madison Symmetric Torus (MST) is now fully operational with 21 spatial points, which cover the entire minor radius. Four full electron temperature profiles can be obtained during each MST discharge, with a variable delay between each profile. This system overcomes challenges that arise from the unique machine design, location, and plasma characteristics of MST. The machine design limits the maximum porthole diameter to 11.4 cm, requiring a compact, re-entrant, seven element lens for scattered light collection. Limited space near MST necessitates a long beam path for the two Nd:YAG lasers requiring a remote beam line adjustment system to suppress drift in the beam position due to thermal expansion of the building. Due to the remote location of the laser head, substantial design effort was put into the creation of a set of safety interlocks for the laser system. The dynamic nature of MST plasmas and the wide range of operating space require a versatile scattered light detection system consisting of filter polychromators with temperature controlled avalanche photodiode detectors. We also implement an insertable integrating sphere, which travels along the laser beam path through the vacuum vessel, for the alignment of both the fiber optics and the lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of first mirror heating for the collective Thomson scattering diagnostic in ITER

Collective Thomson scattering (CTS) has the capabilities to measure phase space densities of fast ion populations in ITER resolved in configuration space, in velocity space, and in time. In the CTS system proposed for ITER, probing radiation at 60 GHz generated by two 1 MW gyrotrons is scattered in the plasma and collected by arrays of receivers. The transmission lines from the gyrotrons to the plasma and from the plasma to the receivers contain several quasioptical mirrors among other components. These are designed to produce astigmatic beam patterns in the plasma where the beam shapes will have a direct impact on the signal strength of the diagnostic, the spatial resolution, and the robustness of probe and receiver beam overlap against density excursions. The first mirror has a line of sight to the plasma and is thus exposed to severe neutron streaming. The present neutronics and thermomechanical modeling of a first mirror on the high field side indicates that the mirror curvature may warp due to heating. This may alter the beam quality, and therefore, thermal effects have to be accounted for during the design of the mirror. The modeling further demonstrates that thin mirrors are superior to thick mirrors from a thermomechanical point of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing a Thomson scattering diagnostic for fast dynamics and high background

The Madison Symmetric Torus (MST) presents challenging conditions for Thomson scattering (TS) measurements. The MST plasmas are reversed-field pinches (RFPs) with electron density n{sub e}<3x10{sup 13} cm{sup -3}, typically 1x10{sup 13} cm{sup -3}. The TS system was designed to measure from 10 eV to 2 keV; however, six polychromators were upgraded from four to eight spectral channels to resolve to 10 keV. There is no diverter or vertical field, so wall interaction results in high background light both from ion and neutral bremsstrahlungs and from line radiation. Also during standard plasmas, the RFP exhibits regular reconnection sawteeth events during which the plasma current, density, and temperature profiles are flattened. These events are of interest both due to the reconnection physics and to their contribution to the MST equilibrium and confinement. These events occur over 100 {mu}S and exhibit large changes in background light and fast changes in temperature. During improved confinement plasmas, there are no sawteeth; the background is low but the temperature can be over an order of magnitude higher. Data analysis of the system has been developed to accommodate both the large dynamic range of the temperature, the fast dynamics, and the fast changing, high amplitude background. Special attention has been paid to the sources of error, in particular, the contribution of the background. A response-function method reduces the measured uncertainty by a factor of 2. Numerical techniques have been developed which are extremely robust. Two methods are used, a conventional {chi}{sup 2} minimization using a Levenberg-Marquardt algorithm coupled with Monte Carlo modeling for the error bar and a Bayesian statistics method. The Bayesian method computes the probability distribution for the measured photons and electron temperature and this information can be used to ensemble data and will allow future integrated data analysis efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a Thomson scattering diagnostic for fluctuation measurements

Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), using an avalanche photodiode (APD) as a reference detector and optical parametric oscillator (OPO). Discussed are a novel in situ spatial calibration with the use of the ISIS, the use of an APD as a reference detector to streamline the APD calibration process, a standard dc spectral calibration, and in situ pulsed spectral calibration made possible with a combination of an OPO as a light source, the ISIS, and an APD used as a reference detector. In addition a relative quantum efficiency curve for the APDs is obtained to aid in uncertainty analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A pulse-burst laser system for a high-repetition-rate Thomson scattering diagnostic

A ''pulse-burst'' laser system is being constructed for addition to the Thomson scattering diagnostic on the Madison Symmetric Torus (MST) reversed-field pinch. This laser is designed to produce a burst of up to 200 approximately 1 J Q-switched pulses at repetition frequencies 5-250 kHz. This laser system will operate at 1064 nm and is a master oscillator, power amplifier. The master oscillator is a compact diode-pumped Nd:YVO{sub 4} laser, intermediate amplifier stages are flashlamp-pumped Nd:YAG, and final stages will be flashlamp-pumped Nd:glass (silicate). Variable pulse width drive (0.3-20 ms) of the flashlamps is accomplished by insulated-gate bipolar transistor switching of large electrolytic capacitor banks. The burst train of laser pulses will enable the study of electron temperature (T{sub e}) and electron density (n{sub e}) dynamics in a single MST shot, and with ensembling, will enable correlation of T{sub e} and n{sub e} fluctuations with other fluctuating quantities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subterahertz gyrotron developments for collective Thomson scattering in LHD

Collective Thomson scattering (CTS) is expected to provide the spatially resolved velocity distribution functions of not only thermal and tail ions but also alpha particles resulting from fusion reactions. CTS using gyrotrons with frequency higher than the conventional ones used for plasma heating would have advantages to alleviate refraction, cutoff effects, and background electron cyclotron emission noise. Therefore, a high-power pulse gyrotron operating at approximately 400 GHz is being developed for CTS in Large Helical Device (LHD). A single-mode oscillation with a frequency greater than 400 GHz, applying the second-harmonic resonance, was successfully demonstrated in the first stage. At the same time, concrete feasibility study based on ray tracing, scattering spectra, and electron cyclotron emission calculations has been conducted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of the JET edge LIDAR Thomson scattering diagnostic with ultrafast detectors

The edge light detection and ranging (LIDAR) Thomson scattering diagnostic at the Joint European Torus fusion experiment uses a 3 J ruby laser to measure the electron density and temperature profile at the plasma edge. The original system used a 1 GHz digitizer and detectors with response times of {approx_equal}650 ps and effective quantum efficiencies <7%. This system has recently been enhanced with the installation of a new 8 GHz digitizer and four new ultrafast GaAsP microchannel plate photomultiplier tube detectors with response times of <300 ps and effective quantum efficiencies in the range of {approx}13%-20% (averaged over {lambda}=500-700 nm). This upgrade has enabled the spatial resolution to be reduced to {approx}6.3 cm along the laser line of sight for a laser pulse of 300 ps full width at half maximum, which is close to the requirements for the ITER core LIDAR. Performance analysis shows that the new system will have an effective spatial resolution of up to 1 cm in the magnetic midplane via magnetic flux surface mapping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new Nd:YAG Thomson scattering system for MAST

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with {approx_equal}10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 deg. to 120 deg. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.