Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High Efficiency Megawatt Motor Stator Thermal Performance

Enabling single aisle electric aircraft propulsion requires power dense, megawatt scale, high efficiency electric machines. To that end NASA has been developing the High Efficiency Megawatt Motor (HEMM) 1.46 MW (16kW/kg), 98% efficient electric machine. The success of this effort is highly dependent on the stator’s thermal (cooling) design. The design to date has been based upon computation fluid dynamic and finite element analysis models that have been validated with testing of stator sub sections that replicate expected thermal conditions. However, the test to validate the model can only be so accurate without fully representing the full geometry and components of the stator. A full HEMM stator has been fabricated, potted, and installed in a housing complete with vacuum tube. This apparatus was used to validate the full thermal environment of HEMM and act as a final validation of the stator design before fully fabricating the machine. This paper discusses the modeling and test results from this penultimate HEMM stator build.

electric machine↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

Thermal performance of FRSI/graphite epoxy materials for the Orbiter TPS application

Radiant tests have been conducted to evaluate the performance of the Flexible Reusable Surface Insulation (FRSI) when bonded to Graphite/Epoxy (G/E) honeycomb sandwich structures. The results from this study indicate reasonable agreement with the baseline FRSI properties that existed prior to this test program. An updated Thermal Math Model (TMM) prediction technique was developed, with the use of the well-defined boundary conditions, which appears to be valid in analyzing the complex heat transfer associated with the honeycomb structure. The updated TM analysis of flight data resulted in good agreement of predicted temperatures with flight data for bondline responses of Orbiter FRSI/GE TPS applications.

Norman, I.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the thermal performance of heat pipe radiators

A comprehensive mathematical model and computational methodology are presented to obtain numerical solutions for the transient behavior of a heat pipe radiator in a space environment. The modeling is focused on a typical radiator panel having a long heat pipe at the center and two extended surfaces attached to opposing sides of the heat pipe shell in the condenser section. In the set of governing equations developed for the model, each region of the heat pipe - shell, liquid, and vapor - is thermally lumped to the extent possible, while the fin is lumped only in the direction normal to its surface. Convection is considered to be the only significant heat transfer mode in the vapor, and the evaporation and condensation velocity at the liquid-vapor interface is calculated from kinetic theory. A finite-difference numerical technique is used to predict the transient behavior of the entire radiator in response to changing loads.

Boo, J. H.↗

Sequential Dual Alignments Introduce Synergistic Effect on Hexagonal Boron Nitride Platelets for Superior Thermal Performance

Planarly aligning 2D platelets is challenging due to their additional orientational freedom compared to 1D materials. Here, this study reports a sequential dual-alignment approach, employing an extrusion-printing-induced shear force and rotating-magnetic-field-induced force couple for platelet planarly alignment in a yield-stress support bath. It is hypothesized that the partial alignment induced by a directional shear force facilitates subsequent axial rotation of the platelets for planar alignment under an external force couple, resulting in a synergistic alignment effect. This sequential dual-alignment approach achieves better planar alignment of 2D modified hexagonal boron nitride (mhBN). Specifically, the thermal conductivity of the 40 wt% mhBN/epoxy composite is significantly higher (692%) than that of unaligned composites, surpassing the cumulative effect of individual methods (only 133%) with a 5 times more synergistic effect. For 30, 40, and 50 wt% mhBN composites, the thermal conductivity values (5.9, 9.5, and 13.8 W m –1 K –1 ) show considerable improvement compared to the previously reported highest values (5.3, 6.6, and 8.6 W m –1 K –1 ). Additionally, a 3D mhBN/epoxy heat sink is printed and evaluated to demonstrate the feasibility of device fabrication. The approach enables the planar alignment of electrically or thermally conducting 2D fillers during 3D fabrication.

36 MATERIALS SCIENCE↗

Thermal Performance of an Aluminum/Ammonia Heat Pipe Under Reflux Mode

During instrument-level or spacecraft-level ground testing, heat pipes may be placed in reflux mode, with condenser above evaporator. A liquid pool will form at the bottom of the heat pipe. If heat is applied to a site below the surface of the liquid pool in a vertical heat pipe, the heat pipe can work properly under reflux mode. A superheat is required for startup. If heat is applied to a site above the liquid pool, the heat pipe is not expected to work unless additional heat is applied to the liquid pool to provide the needed flow circulation. There are many reason to minimize the additional heater power. An experimental investigation was conducted to study the heat pipe behavior under this configuration.

Thermal control systems↗

The importance of maldistribution matching for thermal performance of compact heat exchangers

Compact heat exchangers have gained increased attention in recent years, particularly in demanding applications where high temperatures, high pressures, and/or high power densities are required. For decades, the heat exchanger (HX) community believes that flow maldistribution is a key factor for HX effectiveness, that is, reducing the degree of flow maldistribution (MALD) can help increase the HX effectiveness. Therefore, significant efforts have been devoted in the past to optimizing the header geometry to minimize flow maldistribution. This work was initially motivated by this, and the original goal was to figure out a HX header design with the lowest maldistribution. However, by systematically constructing a comprehensive maldistribution matrix, the analysis revealed that the HX effectiveness is not actually determined by the MALD, but instead dominated by the degree of maldistribution mismatch (MISM). This conclusion was also theoretically generalized, which indicated that matching of the local heat capacity rate is key for achieving maximum performance. The MISM provides a local means of tracking this information, while the MALD only provides a global approximation of the maldistribution itself. With this new perspective, flow maldistribution needs not necessarily be avoided, but instead matched between two fluid streams, to improve the HX performance. We demonstrated that by carefully designing the header geometry to match the velocity profiles of the two fluids in a 2 MW PCHE with molten salt and supercritical carbon dioxide (sCO2) as the heat transfer fluids, the HX could achieve a higher effectiveness even when the maldistribution increased. Finally, a technoeconomic study using a CSP system as an example revealed that the use of this new HX design paradigm could result in CSP capital cost savings as large as 16.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance of an absorption-assisted two-stage ejector air-to-water heat pump

In this work, a gas-fired air-to-water ejector heat pump (EHP) for domestic hot water production is proposed and analyzed thermodynamically. The COP of the EHP is improved by using binary fluids (HFE7500 and water), and the high backpressure in the primary ejector (first-stage) is actively controlled by either a second-stage ejector and/or a LiBr-H 2 O absorption subsystem. A thermodynamic model is established for analysis and performance evaluation. A case study shows the backpressure of the first-stage ejector is reduced by 53.5%, and the backpressure control using the second-stage ejector increases the system COP by 21.0% compared with that using LiBr-H 2 O absorption. Parametric studies are conducted to investigate the roles of the first-stage ejector, the second-stage ejector, and the LiBr-H 2 O absorption subsystem. The first-stage ejector plays a dominant role in the EHP system performance. The EHP’s heating COP can reach 2.0 with an entrainment ratio of 0.12 in the first-stage ejector. EHP performance can be improved with a high entrainment ratio and a low-temperature primary working fluid in the first-stage and second-stage ejectors, a low condensation temperature in the first-stage ejector, and a high generating temperature and a low concentration of the LiBr-H 2 O solution.

30 DIRECT ENERGY CONVERSION↗